Cambridge Phase 1-LR 940601 (2)["-G-~EOTECHNICAL E GEE Consultants, Inc. 2540 Gienda Lane · Suite 108 · Dallas, Texas 75229 · (214) 620-9791 · Fax (214) 620-9794 MOISTURE DENSITY RELATIONSItlP REPORT Test Reisort Date: June 1, 1994 Project No: B-94-0178 cu~nt: Beamer Development Sample gate: May 25, 1994 l'roj~t: Estates of Cambridge Manor, Phase I Iaentification: Moisture Density Relationship T~ Proceaur~: ASTM D698 Test R,sults: Method ......................................... A Optimum Moisture Content ............................. 14.2 percent Maximum Density .................................. 101.1 pounds per cubic foot Rammer Type ..................................... Manual Matm~al Description ................................. Dark Gary Clayey Sand Material Origin .................................... On-site Subgrade (Lake) Moisture Preparation Procedure ........................ ... Air Dry Liquid Limit ...................................... 29 Plastic Limit ...................................... 13 Plasticity Index .................................... 16 Percent Passing a No. 200 U.S. Sieve ...................... 34 Technician: K. Mc./L.G. cc: Mr. Bill Anderson - Dowdy, Anderson and Associate~, Inc. Ourlclt~rsand t~ar~ fo~lhec_._e_hj_.~euocoflh~cl~uttowlimnlh~y ar~. Tlteuseoi'ournma~mnstrecciveourpriorwrilten~gp;ovaL Out lellemandrc~