Loading...
2013_0126_RPZ (3)City of Coppell The following form must be completed for each assembly tested. A signed and dated original must be submitted to the public water supplier for record keeping purposes: BACKFLOW PREVENTION ASSEMBLY TEST AND MAINTENANCE REPORT dame of PWS: PWS I.D. #: 500 Southwestern * P. O. Box 94786 * Coppell, Texas 75019 972 - 304 -3509 * Recorder: 972- 304 -3518 * Fax: 972 - 304 -3514 Name of Business Med Tech (Kelly) 469.688.4489 RoS3 ❑ Residential x Commercial Address of Assembly: 143 S. Denton Tap Rd., Ste. 180 ["Domestic ❑ Irrigation ❑ Fireline The backflow prevention assembly detailed below has been tested and maintained as required by TCEQ (Formerly TNRCC) regulations and is certified to be operating within acceptable parameters. TYPE OF ASSEMBLY It Reduced Pressure Principle ❑ Reduced Pressure Principle- Detector • Double Check Valve ❑ Double Check- Detector • Pressure Vacuum Breaker ❑ Spill Resistant Pressure Vacuum Breaker Manufacturer: W 14+j Size: Model Number: 013 1 u Serial Number: Located At: L -A Pk o J A\ Is the assembly installed in accordance with manufacturer recommendations and /or local codes? Y Remarks: The above is certified to be true at the time of testing. Tester signature: dl„NI ,lam Test gauge used: Make /Model Apollo 40- 200 -TK5U SN 01111194 Cali Oration Date:_6/26/12 Firm Name: 01 Accuracy Backflow Certified Tester (print): Terry Sitgreaves Firm Address: 9990 Barton Cr., Frisco, TX 75035 Cert. Tester No. BP0014573 Exp. Date Firm Phone #: 972.699.7156 Test Date ri - Z G -13 *TEST RECORDS MUST BE KEPT FOR AT LEAST THREE YEARS * *USE ONLY MANUFACTURER'S REPLACEMENT PARTS Reduced Pressure Principle ssembly Pressure Vacuum Breaker Double Check Valve Assembly Air Inlet Check Valve 1 s' check 2" check Relief Valve Open d at _psid Held at psid Initial Test Held at psid Held at JXpsid Opened ate psid Did not open ❑ Leaked ❑ Closed Tight Closed Tight Iff Did not open ❑ Leaked ❑ Leaked ❑ Repairs and Materials Used Test after Held at psid Held at psid Opened at _psid Opened at _psid Held at psid Repair Closed Tight ❑ Remarks: The above is certified to be true at the time of testing. Tester signature: dl„NI ,lam Test gauge used: Make /Model Apollo 40- 200 -TK5U SN 01111194 Cali Oration Date:_6/26/12 Firm Name: 01 Accuracy Backflow Certified Tester (print): Terry Sitgreaves Firm Address: 9990 Barton Cr., Frisco, TX 75035 Cert. Tester No. BP0014573 Exp. Date Firm Phone #: 972.699.7156 Test Date ri - Z G -13 *TEST RECORDS MUST BE KEPT FOR AT LEAST THREE YEARS * *USE ONLY MANUFACTURER'S REPLACEMENT PARTS