Loading...
Duke Lesley- 2RC-140526 Redi-Mix Concrete, L.P. April 9, 2014 a US Concrete Company The Technical Service Department To: KCK Utility Construction Inc 331 North Main St. Euless, TX 76039 Project: 737-14 Coppell Conference Center - Coppell Office: (817) 835-4100 Fax: (817) 835-4074 Submittal Provisions RE: RedimixQC@us-concrete.com www.us-concrete.com Enclosed you will find the necessary submittal documents for the referenced project above for your review. Redi-Mix’s strength guarantee per ASTM C94 will not be effective unless the field sampling has been done per ASTM C172 and ASTM C31 and the laboratory testing fully complies with ASTM C39 and ASTM C1077. Redi-Mix will also 55F and 95F guarantee the strength performance of the mix designs submitted for a concrete temperature between °° This provided the design plastic properties are not exceeded and the concrete is placed within 90 minutes of batch time. concrete temperature range shall not supersede any more restrictive temperature specification. All concrete should be placed and cured with the appropriate ACI guidelines and recommendations for hot and cold weather Redi-Mix cannot be responsible for non-conformance of strength if cylinders are not cured per ACI concreting. 301, section 1.6.3.2.d. Hot weather concreting practices will require the purchaser to order ice and/or chilled water to The purchaser shall be responsible for precautions taken against meet concrete temperature specifications. excessive wind, heat and low humidity per ACI 305 guidelines. The purchaser shall assume responsibility for any concrete defects related to the finishing process (cracking, scaling, dusting, delamination, discoloration, etc.), which is beyond Redi-Mix’s control. This includes proper preparation, compaction and wetting of subgrade as well as proper spacing and depth of joints and rebar. During periods of cold weather, all concrete surfaces should be protected from freezing for at least the first 24 hours after placement to allow the concrete to attain a Should the purchaser elect not to order temperature control measures, the compressive strength of 500 psi. purchaser shall then assume all liability for costs associated with rejected concrete due to non-compliant concrete temperature. According to ACI 304.2R Section 4.2.1 “Placing Concrete by Pumping Methods”, the inside diameter of the hose should be a minimum of 3 times the maximum angular aggregate size of the concrete. (ASTM C33 allows #57LS to have up to 5% retained on the 1” sieve). It is recommended to minimize or eliminate the free fall of concrete to avoid With regard to loss of air content. Depending on boom configurations, alterations to the mix design may be required. pumped concrete, the various boom configurations, length of hose, line reductions and free fall distance are beyond Redi-Mix’s control and we therefore cannot be responsible for loss of air content or any costs associated with either rejected fresh concrete or the removal and replacement of hardened concrete due to non-compliant air content resulting from this or from placing concrete outside of the slump range specified on the mix design. We thank you for allowing us to submit these documents for your review. Please copy Redi-Mix with the approved submittal. The approved submittal allows Redi-Mix to review any notes, comments or exceptions made by the engineer . Failure to notify us prior to first placement shall constitute acceptance of the or owner relating to the specification submitted mix designs and submittal provisions. Please order by mix number when scheduling concrete delivery. We request that Redi-Mix be added to the list of names receiving copies of testing laboratory information for this project. ASTM C94 entitles a manufacturer to receive copies of all test reports when strength of concrete is used as a basis for acceptance. This information is another tool for Redi-Mix to review and monitor the quality and performance of the concrete product delivered. The information within this submittal is confidential and the exclusive property of Redi-Mix. It shall not be disseminated to third parties without written permission from Redi-Mix Concrete. Please contact Technical Services with any questions at (817) 835-4186.Respectfully, Carol Dunn Technical Services Supervisor Date:4/9/2014 Mix Number:10L11504 Redi-Mix Concrete, L.P. Strength:4200 psi @ 28 days A US-Concrete Company Description: 6.0 SK AIR NR 331 N.Main St Euless, TX 76039 Plant No.:259 Technical Service: (817)-835-4187 Customer: KCK Utility Construction Inc Dispatch: (817) 835-4020 Project:737-14 Coppell Conference Center - Coppell Fax: (817) 835-4074 E-mail: Usage: Drainage Structures redimixqc@us-concrete.com www.us-concrete.com Saturated Surface Dry Weights Per Cubic Yard MaterialSourceQuantityVol ASTM C150 Type l/ll CementCemex, Balcones.1564 lb2.87 100.00 ASTM C33 No. 57 LS31825 Martin Marietta, Chicolb11.21 ASTM C33 Fine AggregateRedi-Mix Concrete31282lb7.84 ASTM C494 A & D NRWRBASF Pozzolith322/ Set R 3002-4oz/cw ASTM C260 Air EntrainmentBASF MasterAir AE90oz/cy1-41.08 ASTM C94 Water30gal4.00 Total Volume: 27.00 Specified SlumpSpecified Air Percent: 4+/- 1"4.5+/- 1.5% Wet Unit Weight:145.2lb/ft^3Design w/c ratio:0.44 The use of an EF Technology mix design will reduce the amount of entering the atmosphere, thereby reducing potential global warmi "Your Project, Our World" Notes:Please make sure that redimixqc@us-concrete.com is on the list t Admixtures may be adjusted, depending on ambient conditions, at This mix has been designed to meet the requirements of this project based on the information sent to Redi-mix Concrete. It is the responsibility of the purchaser to determine whether this mix design meets project specifications and is appropriate for the anticipated environment conditions. The specified strength guarantee per ASTM C94 will not be effective unless field sampling has been done per ASTM C172 and ASTM C31 and the laboratory fully complies with ASTM C39 and ASTM C1077. In the event of limited material avaliability, substitution of a similar performing material may be required. All substituted materials will meet the appropriate ASTM requirements. In order to maintain the required mix volume, weights of individual materials may be varied to accommodate different material specific gravities. Material certifications for substituted materials are avaliable upon request. All Redi-Mix Concrete mix designs are proprietary and confidential. The information contained in this submittal is only intended for parties associated with this project to validate the mix design materials, properties and its performance. Use of this submittal for other purposes without permission or consent from Redi-Mix Concrete is strictly prohibited. THE NEW RESOURCE FOR THE CONSTRUCTION INDUSTRY 2580 Wald Road CEMENT New Braunfels, TX 78132 MILL Telephone (210) 250-4100 FAX (210) 250-4044 TEST Customer Service REPORT TXDOT MPL # 99332 Telephone (800) 492-9004 Material # 1442809 FAX (210) 250-4153 Date of Report: 12/01/2013 Cement Identified as:Balcones Type I, Type II Low Alkali Plant:Beginning Production Date: CEMEX Cement of Texas, LPNovember 1, 2013 Location:Ending Production Date: New Braunfels, TXNovember 30, 2013 CHEMICAL REQUIREMENTSSpec. LimitTYPE ITYPE IITEST Low AlkaliLow AlkaliRESULTS (ASTM C-114)(ASTM C-150) 20.5 Silicon Dioxide (SiO2), %------ Min 4.6 Aluminum Oxide (Al2O3), %---6.0 Max 3.4 Ferric Oxide (Fe2O3), %---6.0 Max 64.8 Calcium Oxide (CaO), %------ --- 1.2 Magnesium Oxide (MgO), %6.06.0 Max 2.8 Sulfur Trioxide (SO3), % *3.03.0 Max 2.3 Loss on Ignition (LOI), %3.03.0 Max 0.22 Insoluble Residue (IR), %0.750.75 Max 1.6 Free Lime, %------ --- 0.55 Alkalies (Na2O equivalent), %0.600.60 Max 0.55+/-0.02 ------ Na2O Equ. @ 95% Confidence Level--- 1.27 CO2 in Cement, %------ --- 2.15 Limestone in Cement, %5.05.0 Max 93 CaCO3 in Limestone, %7070 Min Inorganic Processing Addition, % **5.05.01.99 Max PONTENTIAL PHASE COMPOSITION *** 57 Tricalcium Silicate (C3S), %------ Max 6 Tricalcium Aluminate (C3A), %---8 Max Heat Index, C3S + (4.75 C3A)10010087 Max PHYSICAL REQUIREMENTS 398 Blaine Fineness, m2/kg280280 Min (ASTM C-204) Time of Setting (Vicat) (ASTM C-191) 111 Initial Set, mins4545 Min 200 Final Set, mins375375 Max Time of Setting (Gillmore) (ASTM C-266) 152 Initial Set, mins6060 Min 226 Final Set, mins600600 Max 8.6 Air Content, %1212 Max (ASTM C-185) 0.02 Autoclave Expansion, %0.800.80 Max (ASTM C-151) Compressive Strength (ASTM C-109) 2380 1-Day, psi------ --- 3930 3-Day, psi17401450 Min 4840 7-Day, psi27602470 Min 6140 (Previous) 28-Day, psi------ --- 82 Test result is provided for information only Heat of Hydration (7-Day), cal/g (ASTM C-186) * The performance of CEMEX Type I LA, Type II LA has proven to be improved with sulfur trioxide levels in excess of the 3.0% limit for Type II. Note D in ASTM C-150 allows for additional sulfate, provided expansion as measured by ASTM C-1038 does not exceed 0.020%. ** This cement contains processing additions which meet the requirements of ASTM C-465. Compliance documents are available upon request. Additional data for the Inorganic Processing Addition is located on page 2 of this certification. *** Potential Phase Composition adjusted per A1.6. CEMEX hereby certifies that this cement meets or exceeds the chemical and physical specifications of: [ X ] ASTM C-150 for Type I Low Alkali [ X ] ASTM C-150 for Type II Low Alkali By: Quality Control Manager CEMEX - Balcones Cement Plant 2580 Wald Road CEMENT New Braunfels, TX 78132 MILL Telephone (210) 250-4100 FAX (210) 250-4044 TEST Customer Service REPORT Telephone (800) 492-9004 FAX (210) 250-4153 Cement Identified as:Balcones Type I, Type II Low Alkali Date of Report: 12/01/2013 Plant:Beginning Production Date: CEMEX Cement of Texas, LPNovember 1, 2013 Location:Ending Production Date: New Braunfels, TXNovember 30, 2013 ADDITIONAL DATA Inorganic Processing Addition TypeLime Kiln Dust (LKD) Silicon Dioxide (SiO2), %15.4 Aluminum Oxide (Al2O3), %1.8 Ferric Oxide (Fe2O3), %-0.8 Calcium Oxide (CaO), %89.8 Sulfur Trioxide (SO3), %7.6 Base Cement Phase Composition C3S, %59 C2S, %16 C3A, %7 C4AF, %11 CEMEX hereby certifies that the above described data represents the materials used in the cement manufactured during the production period indicated. By: Quality Control Manager CEMEX - Balcones Cement Plant REDI-MIX TECHNICAL SERVICES LABORATORY SIEVE ANALYSIS RESULTS Plant:REDI-MIX CONCRETE, Plant 259 Product:Fine Aggregate, ASTM C33 Section 5 Date Sampled:8/12/13 Date Tested:11/4/13 Tested by:WCH ASTM Percentage SPEC'S %Ret%Pass Sievemm- 1 1/238.10100 0- 125.40100 0 3/4"19.00100 0100 1/2"12.70100 0100 3/8"9.51100 0100 #44.7696 495-100 #82.3884 1680-100 #161.1967 3350-85 #300.6044 5625-60 #500.3020 8005-30 #1000.155 950-10 Pan1 99- #200 (Decant)0.072 -0-3 FM2.8 2.3 - 3.1 ABS%1.0 S.G.2.61 Technical Resource Supervisor