Hollywood-RS 940225 ELEVATION CERTIFICATE
Expires May $ I, 1993
FEDERAL EMERGENCY MANAGEMENT AGENCY
NATIONAL FLOOD INSURANCE PROGRAM
ATTENTION: Use of this certificate does not provide a waiver of the flood insurance purchase requirement. This form is used only to
provide elevation information necessary to ensure compliance with applicable community floodplain management ordinances, to
determine the proper insurance premium rate. and/or to support a request for a Letter of Map Amendment or Revision (LOMA or LOMR).
Instructions for completing this form can be found on the following pa! es.
SECTION A PROPERTY INFORMATION FOR INSURANCE COMPANY USE
POLICY NUMBER
BUILDING OWNER'S NAME
£FNTENNIAL HOMES. INC,..
STREET ADDRESS (IncluOing Apt.. Unit. Suite anO/or BIOg. Number) OR P.O. ROUTE AND BOX NUMBER
204 Hollywood Drive
COMPANY NAIC NUMBER
OTHER DESCRIPTION ILot snd Block Numbers, etc.)
[,ot 24. Block D, Lakewood Estates
CITY STATE
Cit, y of Coppel 1 Tex~
SECTION B FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
ZIP CODE
75019
Provide the following from the proper FIRM (See Instructions):
1, COMMUNITY NUMBER
480170
2. PANEL NUMBER
0010
3. SUFFIX
D
4, DATE OF FIRM INDEX
10/16/91
5. FIRM ZONE I 6. BASE FLOOD ELEVATION
I
(in AD Zones, use del3t~)
7. Indicate the elevation datum system used on the FIRM for Base Flood Elevations (BFE): ~ NGVD '29 ' Other (describe on back)
8. For Zones A or V, where no BFE is provided on the FIRM, and the community has established a BFE for this building site, indicate
the community's BFE: ~ 449.0.~ feet NGVD (or other FIRM datum-see Section B, Item 7).
SECTION C BUILDING ELEVATION INFORMATION
1. Using the Elevation Certificate Instructions, indicate the diagram number from the diagrams found on Pages 5 and 6 that best
describes the subject building's reference level
2(a). FIRM Zones Al-A30, AE, AH, and A (with BFE). The top of the reference level floor from the selected diagram is at an elevation
of i ' 450,4~ feet NGVD (or other FIRM datum-see Section B, Item 7).
(bi. FIRM Zones V1-V30, VE, and V (with BFE). The bottom of the lowest horizontal structural member of the reference level from
the selected diagram, is at an elevation of' ~ : :: ~ feet NGVD (or other FIRM datum-see Section B, Item 7).
(c). FlrlM Zone A (without SFE). The floor used as the reference level from the selected diagram is i : ! feet above ~_. or
below L__J (check one) the highest grade adjacent to the building.
(d). FIRM Zone AD. The floor used as the reference level from the selected diagram is __.__ feet above -' or below _ (check
one) the highest grade adjacent to the building. If no flood depth number is available, is the building's lowest floor (reference
level) elevated in accordance with the community's floodplain management ordinance? _ Yes _ No .._: Unknown
3. Indicate the elevation datum system used in determining the above reference level elevations: ;X__ NGVD '29 ~ Other (describe
under Comments on Page 2). (NOTE: If the elevation datum used in measuring the elevations is different than that used on
the FIRM [see Section B, Item 7], then convert the elevations to the datum system used on the FIRM and show the conversion
equation under Comments on Page 2.) . _
4. Elevation reference mark used appears on FIRM: ~ ' Yes :~X No (See Instructions on Page 4) '-'-
5. The reference level elevation is based on: .Z_ actual construction __ construction drawings
(NOTE: Use of construction drawings is only va/id if the building does not yet have the reference/eve/floor in p/ace, in which
case this certificate will only be valid for the building during the course of construction. A post-construction Elevation Certificate
will be required once construction is complete.)
6. The elevation of the lowest grade immediately adjacent to the building is: . 449, .Z__ feet NGVD (or other FIRM datum-see
Section B, Item 7).
SECTION D COMMUNITY INFORMATION
1. If the community official responsible for verifying building elevations specifies that the reference level indicated in Section C, Item 1
is not the "lowest floor" as defined in the community's floodplain management ordinance, the elevation of the building's "lowest
floor" as defined by the ordinance is: .~ feet NGVD (or other FIRM datum-see Section B, Item 7).
2. Date of the start of construction or substantial improvement 3/1/94
FEMA Form 81-31~ MAY 90 REPLA(:ES ALL PREVIOUS EDITIONS SEE REVERSE SIDE FOR CONTINUATION
SECTION E CERTIFICATION ·
This certification is to be signed by a land surveyor, engineer, or architect who is authorized by state or local law to certify elevation
information when the elevation information for Zones Al-A30, AE. AH, A (with BFE),V1-V30,VE, and V (with BFE) is required.
Community officials who are authorized by local law or ordinance to provide floodplain management information, may also sign the
certification. In the case of Zones Ab and A (without a FEMA or community issued BFE), a building official, a proDerty owner, or an
owner's representative may also sign the certification.
Reference level diagrams 6, 7 and 8 - Distinguishing Features-If the certifier is unable to certify to breakaway/non-breakaway wall,
enclosure size, location of servicing ecluipment, area use, wall openings, or unfinished area Feature(s), then list the Feature(s) not
included in the certification under Comments below. The diagram number, Section C, Item 1, must still be entered.
I certify that the information in Sections B and C on this certificate represents my best efforts to interpret the data available.
I understand that any false statement may be punishable by fine or impriSonment under 18 U.S. Code, Section 1001.
CERTIFIER'S NAME
Dan B. Ramsey
LICENSE NUMBER (or Affix Seal)
R.P.L.S. No. 4172
TITLE COMPANY NAME
Surveyin§ Manaqer Jones & Bo.yd, Inc.
ADDRESS CITY STATE
17300 Da~l~3as Parkway, Suite 3010 Dallas Texas 75248
SIGNATURE /.,. / ,,~ ~ /DATE/ . PHONE
~_~/ 214-248-7676
Copies should be made of this Cert~cate for: 1) community official, 2) insurance agent/company, and 3) building owner.
ZIP
COMMENTS:
ON
SLAB
A V
ZONES ZONES
wll~
BASEMENT
A
ON PILES.
PIERS. OR COLUMNS
A V
ZONES ZONES
The aiagrams above illustrate the Doints at wt~ich the elevations should be measured in A Zones and V Zones.
Elevations for all A Zones should be measured at the tod of the reference level floor.
Elevations for all V Zones sl~ould be measured at the bottom of the lowest horizontal structural member.
Page 2
SENT BY:Jones'& Boy~, Inc, ; 2-22-94 ;10:3?AM ~ 3922@99- 214 490 ?623;# 2
Drive Area: 1356 Sq. Ft.
Walk Area: 266 Sq. Ft.
Lot Area: 16254 Sq.Ft.
Type 'A' Drainage
Trendmaker Homes
5?20 {J~J Freeway, Sw{te 610
I;)OIIos. 'Texas 75240
(214) 458-9909
LAKEWOOD ESTATES
addre.s
HOLLYWOOD
COPPELL, TX.
· '"" FOUNDATION FORM SURVEY
TO ALL PARTIES INTI[EES~ IN PREMISES SURVEYED:
This is to certify that I have, this date, made a careful and accurate on the ground survey of the property located
at _~_~_~__//o//'.//~/o~¢/ ~E/J~_ ....... in the C/'~u ~f" Co~?~// .,Texas, described as
BEING Lot 24_ Block /~), of _ Lq.~e_amo~ ~'$/.~_~ __,an edditlan to
the /~.//y ~__~__~'~o_~/L Texas according to the _L~__ thereof recorded in .~_~,L~e ~$0/~. /:~e
of the ~_ R~ords of ~z~ C~ty, Texas.
:This property does not lie within the boundaries of the lO0-yeor flood plain according to the flood boundary and
floodway Mop No. ~_L_ZO ~_/__.~_Q__ effective Z:~C/o~er /~_/..~/'
The plat hereo~ ia a true, co~rect and accurate repre~entatio~ of
the prol~y aa determined by thla =ur,~y, the ti~e~ and dlme~eio~a
of m31d property being a~ indicated by the I;~3t; the Mze. Iocatloe.
t)~e of buldinge end Improvements are ~hown, improvements
being wtthl~ the boundortee of the property, ~et beck from the ·
property Ilnee the dl~tancee indicated, and there are no ~,,
encrochm/er~, ar protrusions, except ae noted.
Regietered Professional Lonprveyor No. 4172
JONES & BOYD, INC.
CONSULllNG ENGINEERS
17300 Dallas Parkway, Suite 5010
Dallas, Texas 75248
214-248- 7676
SCALE: DATE DRAWN Pl~J[CT
5' Tepee Uf/'fify
//
//
RE~4S~O~S