Loading...
Coppell_E-Care-LR140826 ECS Texas, LLP 3033 Kellway Drive, Suite 110 CONCRETE, GROUT, AND MORTAR TESTS Carrollton, TX 75006 LETTER OF TRANSMITTAL (972) 392-3222 [Phone] (214)483-9684 [Fax] Texas Registered Engineering Firm # F-8461 08/26/2014 DATE: TO:Interra Partners, LLC Lincoln Centre, Building 3 Coppell E-Care RE: 5430 LBJ Freeway, Suite 960 PERMIT #: Dallas, TX 75240 ATTN:Mr. WilliamR. Hurd JOB NO.:005924A1 LOCATION: 330 S Denton Tap Road, Coppell, TX Dallas County Weare enclosing: XAttachedXFor Your Use XMaterials Engineering Division Concrete Reports:As Requested X 19, 20 NOTE: LOW TEST RESULTS REPORTS 19, 20 CityOf Coppell - Rick O'dell CC: Hill & Wilkinson Construction Group, Ltd - Matthew Vea Hill & Wilkinson Inc. - Jason Avant Jennifer Shields, P.G.Victor Faltas AUG 26 2014 By: Project GeologistProject Engineer This report (and any included attachments) shall not be reproduced, except in full, without the prior written approval of ECS. Concrete Cylinders Strength Report ECS Texas, LLP 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 Project :Set Designation:A 5924-A1 (972) 392-3222 [Phone] Cast Date: (214)483-9684 [Fax] 06/30/2014 Design Strength: 4000 psi Project:Coppell E-Care Report No.: 19 Location:330 S Denton Tap Road, Coppell, TX Interra Partners, LLC - WilliamR. Hurd Owner:Client: Interra Partners, LLC - WilliamR. Hurd Arch.: Gen. Contr.:Hill & Wilkinson Inc. - Jason Struc. Eng.:Conc. Contr.: Placement Location:Pavements Concrete Supplier:Burnco ConcreteTruck No:899Ticket No:50102958 Mix Designation:40U100AGMix Strength:4000 psiBatch Time: 09:20AM Added Water: 10 Gals.Time Added:10:15AM TimothyTarbutton6.50 in. FIELD TEST DATA:Tested by:Time Sampled:10:20AMSlump: Air Content: Temperature - Air:85º FConcrete:90º F 2.90 % (P) AverageAvg. Measured Type SampleTestTestBreakingCompr.BrkReview MeasuredCross-Sectional Cure NoDateAgeTypby Load,lbs Str.,psi Diameter in.Area in.-sq 10260707/07/20147Lab4.0012.563619228802VF 10260807/28/201428Lab4.0012.564428835203VF 10260907/28/201428Lab3.9912.504329634602VF 10261007/28/201428Lab4.0012.564460835503VF 10261108/25/201456Lab3.9812.444595236903VF Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or bonded caps iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. FIELD CURING CONDITIONS: InsulatedCooledIce Curing Box X No Curing BoxHeatedCapsOther X Remarks: Final Review By: NOTE: LOW TEST RESULTS VF Print Date:08/26/2014 BR01 Concrete Cylinders Strength Report ECS Texas, LLP 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 Project :Set Designation:B 5924-A1 (972) 392-3222 [Phone] Cast Date: (214)483-9684 [Fax] 06/30/2014 Design Strength: 4000 psi Project:Coppell E-Care Report No.: 20 Location:330 S Denton Tap Road, Coppell, TX Interra Partners, LLC - WilliamR. Hurd Owner:Client: Interra Partners, LLC - WilliamR. Hurd Arch.: Gen. Contr.:Hill & Wilkinson Inc. - Jason Struc. Eng.:Conc. Contr.: Placement Location:Parking Lot Pavements Concrete Supplier:Burnco ConcreteTruck No:900Ticket No:30102982 Mix Designation:40U100AGMix Strength:4000 psiBatch Time: 11:53AM Added Water: 10 Gals.Time Added:12:45PM TimothyTarbutton6.75 in. FIELD TEST DATA:Tested by:Time Sampled:12:55PMSlump: Air Content: Temperature - Air:93º FConcrete:94º F 2.80 % (P) AverageAvg. Measured Type SampleTestTestBreakingCompr.BrkReview MeasuredCross-Sectional Cure NoDateAgeTypby Load,lbs Str.,psi Diameter in.Area in.-sq 10261207/07/20147Lab4.0012.563408027101VF 10261307/28/201428Lab4.0012.563833630502VF 10261407/28/201428Lab4.0012.563852830703VF 10261507/28/201428Lab4.0012.563340826603VF 10261608/25/201456Lab3.9912.504252834003VF Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or bonded caps iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. FIELD CURING CONDITIONS: InsulatedCooledIce Curing Box X No Curing BoxHeatedCapsOther X Remarks: Final Review By: NOTE: LOW TEST RESULTS VF Print Date:08/26/2014 BR01