Park West Crossing-LR140512CR0006, 10-16-13, Rev.7 Page 1 of 1 LABORATORY COMPACTION CHARACTERISTICS OF SOIL REPORT Report Number:94141126.0001 Service Date: 05/12/14 8901 Carpenter Frwy., Suite 100 Report Date:05/15/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number 94141126 Material Information Sample Information Source of Material:Native Sample Date:05/12/14 Proposed Use:Common fill Sampled By:Paul Butler Sample Location:-1' @ Building pad Sample Description:Dark brown clay with trace sand Laboratory Test Data Result Specifications Test Procedure:ASTM D698 Liquid Limit:75 Test Method:Method A Plastic Limit:27 Sample Preparation:Wet Plasticity Index:48 Rammer Type:Mechanical In-Place Moisture (%): Maximum Dry Unit Weight (pcf):95.3 Passing #200 (%):85.0 Optimum Water Content (%):24.2 USCS:CH Comments: Services:Moisture-Density Relations Terracon Rep.: Paul Butler Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By:_______________________________ James D. Baze Project Manager Test Methods:ASTM D698, ASTM D1140, ASTM D4318 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Zero Air Voids Curve for Assumed Specific Gravity 2.70 323130292827262524232221201918 89 90 91 92 93 94 95 96 97 Water Content (%) D r y U n i t W e i g h t ( p c f ) CR0006, 10-16-13, Rev.7 Page 1 of 1 LABORATORY COMPACTION CHARACTERISTICS OF SOIL REPORT Report Number:94141126.0002 Service Date: 05/12/14 8901 Carpenter Frwy., Suite 100 Report Date:05/15/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number 94141126 Material Information Sample Information Source of Material:Native Sample Date:05/12/14 Proposed Use:Common fill Sampled By:Paul Butler Sample Location:-7' @ Building pad Sample Description:Brown, tan and gray clay with trace sand Laboratory Test Data Result Specifications Test Procedure:ASTM D698 Liquid Limit:74 Test Method:Method A Plastic Limit:24 Sample Preparation:Wet Plasticity Index:50 Rammer Type:Mechanical In-Place Moisture (%): Maximum Dry Unit Weight (pcf):96.2 Passing #200 (%):85.7 Optimum Water Content (%):23.0 USCS:CH Comments: Services:Moisture-Density Relations Terracon Rep.: Paul Butler Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By:_______________________________ James D. Baze Project Manager Test Methods:ASTM D698, ASTM D1140, ASTM D4318 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Zero Air Voids Curve for Assumed Specific Gravity 2.70 3130292827262524232221201918 89 90 91 92 93 94 95 96 97 98 Water Content (%) D r y U n i t W e i g h t ( p c f ) SUBGRADE VERIFICATION OBSERVATION REPORT Report Number:94141126.0003 Service Date:05/14/14 8901 Carpenter Frwy., Suite 100 Report Date:05/20/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Travel to the project site to perform testing/observation services as requested. Terracon Rep.: Armando Rendon Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 dgr On this date, Terracon's representative arrived at the above referenced job site as scheduled to verify excavation of bldg. pad D. The following was observed and/or tested. Terracon’s representative observed that the south end of the pad was excavated down to 11 foot and all the upper clays were removed. The rest of the pad was not complete at the time of this observation. FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0004 05/15/14 05/22/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4195.324.294141126.0001 Dark brown clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad D 1 15' N & 180' W of SE corner of pad 10' BFG 1 6 118.0 28.9 32.4 89.1 93 2 15' N & 180' W of SE corner of pad 9' BFG 1 6 119.3 29.0 32.1 90.3 95 3 15' N & 180' W of SE corner of pad 8' BFG 1 6 119.1 29.1 32.3 90.0 94 4 15' N & 180' W of SE corner of pad 7' BFG 1 6 118.3 28.7 32.0 89.6 94 5 15' N & 180' W of SE corner of pad 6' BFG 1 6 119.0 29.2 32.5 89.8 94 6 15' N & 20' W of SE corner of pad 10' BFG 1 6 118.3 28.8 32.2 89.5 94 7 15' N & 20' W of SE corner of pad 9' BFG 1 6 118.8 28.9 32.1 89.9 94 8 15' N & 20' W of SE corner of pad 8' BFG 1 6 118.5 29.0 32.4 89.5 94 9 15' N & 20' W of SE corner of pad 7' BFG 1 6 118.7 29.0 32.3 89.7 94 10 15' N & 20' W of SE corner of pad 6' BFG 1 6 119.5 29.4 32.6 90.1 95 11 15' N & 20' W of SE corner of pad 5' BFG 1 6 119.1 28.3 31.2 90.8 95 12 15' N & 20' W of SE corner of pad 4' BFG 1 6 118.7 28.1 31.0 90.6 95 13 15' N & 20' W of SE corner of pad 3' BFG 1 6 118.9 28.0 30.8 90.9 95 14 15' N & 20' W of SE corner of pad 2' BFG 1 6 118.9 28.2 31.1 90.7 95 15 20' N & 170' W of SE corner of pad 5' BFG 1 6 118.5 28.0 30.9 90.5 95 16 20' N & 170' W of SE corner of pad 4' BFG 1 6 119.2 28.4 31.3 90.8 95 17 20' N & 170' W of SE corner of pad 3' BFG 1 6 118.8 28.2 31.1 90.6 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0004 05/15/14 05/22/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 18 20' N & 170' W of SE corner of pad 2' BFG 1 6 118.8 28.4 31.4 90.4 95 19 15' N & 20' W of SE cornber of pad 1' BFG 1 6 119.4 28.5 31.3 90.9 95 20 20' N & 170' W of SE corner of pad 1' BFG 1 6 118.8 28.2 31.1 90.6 95 21 40' N & 20' W of SE corner of pad 10' BFG 1 6 119.3 29.0 32.1 90.3 95 22 40' N & 20' W of SE corner of pad 9' BFG 1 6 118.6 28.6 31.8 90.0 94 23 40' N & 20' W of SE corner of pad 8' BFG 1 6 119.0 28.6 31.6 90.4 95 24 40' N & 20' W of SE corner of pad 7' BFG 1 6 119.0 28.8 31.9 90.2 95 25 40' N & 180' W of SE corner of pad 10' BFG 1 6 120.0 29.3 32.3 90.7 95 26 40' N & 180' W of SE corner of pad 9' BFG 1 6 119.3 28.9 32.0 90.4 95 27 40' N & 180' W of SE corner of pad 8' BFG 1 6 119.4 28.8 31.8 90.6 95 28 40' N & 180' W of SE corner of pad 7' BFG 1 6 119.6 29.1 32.2 90.5 95 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 2 SUB GRADE VERIFICATION OBSERVATION REPORT Report Number:94141126.0005 Service Date:05/15/14 8901 Carpenter Frwy., Suite 100 Report Date:05/22/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Travel to the project site to perform testing/observation services as requested. Terracon Rep.: Armando Rendon Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 dgr On this date, Terracon's representative arrived at the above referenced job site as scheduled for sub grade verification observation. The following was observed and/or tested. Terracon’s representative arrived on site to verify the excavation of Bldg. C. The south end of the pad was excavated down to 11 foot and all the upper clays were removed. The rest of the pad was not complete at the time of this observation. FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0006 05/16/14 05/22/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4195.324.294141126.0001 Dark brown clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad D 29 40' N & 20' W of SE corner of pad 6' BFG 1 6 119.4 28.7 31.6 90.7 95 30 40' N & 20' W of SE corner of pad 5' BFG 1 6 118.9 28.4 31.4 90.5 95 31 45' N & 80' W of SE corner of pad 6' BFG 1 6 118.7 28.3 31.3 90.4 95 32 45' N & 80' W of SE corner of pad 5' BFG 1 6 119.1 28.5 31.5 90.6 95 33 50' N & 90' W of SE corner of pad 10' BFG 1 6 118.3 28.1 31.2 90.2 95 34 50' N & 90' W of SE corner of pad 9' BFG 1 6 118.4 28.4 31.5 90.0 94 35 50' N & 90' W of SE corner of pad 8' BFG 1 6 118.8 28.4 31.4 90.4 95 36 50' N & 90' W of SE corner of pad 7' BFG 1 6 119.2 28.6 31.6 90.6 95 37 50' N & 90' W of SE corner of pad 6' BFG 1 6 119.2 28.4 31.3 90.8 95 38 50' N & 90' W of SE corner of pad 5' BFG 1 6 118.8 28.6 31.7 90.2 95 39 40' N & 20' W of SE corner of pad 4' BFG 1 6 118.9 28.6 31.7 90.3 95 40 40' N & 20' W of SE corner of pad 3' BFG 1 6 119.1 28.5 31.5 90.6 95 41 40' N & 20' W of SE corner of pad 2' BFG 1 6 118.7 28.3 31.3 90.4 95 42 40' N & 20' W of SE corner of pad 1' BFG 1 6 119.4 28.7 31.6 90.7 95 43 45' N & 90' W of SE corner of pad 4' BFG 1 6 119.4 28.9 31.9 90.5 95 44 45' N & 90' W of SE corner of pad 3' BFG 1 6 119.5 28.7 31.6 90.8 95 45 45' N & 90' W of SE corner of pad 2' BFG 1 6 119.3 28.8 31.8 90.5 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0006 05/16/14 05/22/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 46 45' N & 90' W of SE corner of pad 1' BFG 1 6 118.6 28.4 31.5 90.2 95 47 50' N & 190' W of SE corner of pad 4' BFG 1 6 118.4 28.5 31.7 89.9 94 48 50' N & 190' W of SE corner of pad 3' BFG 1 6 118.4 28.4 31.5 90.0 94 49 50' N & 190' W of SE corner of pad 2' BFG 1 6 118.8 28.4 31.4 90.4 95 50 50' N & 190' W of SE corner of pad 1' BFG 1 6 118.7 28.5 31.6 90.2 95 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0007 05/17/14 05/23/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4195.324.294141126.0001 Dark brown clay with trace sand ASTM D698 92-98>/= +4296.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. D, Moisture Conditioning 51 80' N & 20' W of SE corner of pad 10' BFG 1 6 119.0 27.9 30.6 91.1 96 52 80' N & 20' W of SE corner of pad 9' BFG 1 6 119.3 27.7 30.2 91.6 96 53 80' N & 20' W of SE corner of pad 8' BFG 1 6 119.1 27.8 30.5 91.3 96 54 80' N & 20' W of SE corner of pad 7' BFG 1 6 119.9 28.2 30.7 91.7 96 55 80' N & 20' W of SE corner of pad 6' BFG 1 6 119.3 27.8 30.4 91.5 96 56 80' N & 20' W of SE corner of pad 5' BFG 1 6 118.8 27.6 30.3 91.2 96 57 80' N & 100' W of SE corner of pad 10' BFG 1 6 119.0 28.1 30.9 90.9 95 58 80' N & 100' W of SE corner of pad 9' BFG 1 6 119.7 28.5 31.2 91.2 96 59 80' N & 100' W of SE corner of pad 8' BFG 1 6 118.5 27.8 30.7 90.7 95 60 80' N & 100' W of SE corner of pad 7' BFG 1 6 118.8 27.8 30.5 91.0 95 61 80' N & 100' W of SE corner of pad 6' BFG 1 6 118.8 28.0 30.8 90.8 95 62 80' N & 100' W of SE corner of pad 5' BFG 1 6 119.0 27.9 30.6 91.1 96 Bldg. Pad 63 80' N & 180' W of SE corner of pad 10' BFG 1 6 117.7 27.4 30.3 90.3 95 64 80' N & 180' W of SE corner of pad 9' BFG 1 6 118.3 27.7 30.6 90.6 95 65 80' N & 180' W of SE corner of pad 8' BFG 1 6 118.7 27.9 30.7 90.8 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 3 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0007 05/17/14 05/23/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 66 80' N & 180' W of SE corner of pad 7' BFG 1 6 118.1 27.6 30.5 90.5 95 67 80' N & 180' W of SE corner of pad 6' BFG 1 6 117.6 27.4 30.4 90.2 95 68 80' N & 180' W of SE corner of pad 5' BFG 1 6 118.3 27.9 30.9 90.4 95 69 80' N & 20' W of SE corner of pad 4' BFG 2 6 117.5 26.8 29.6 90.7 94 70 80' N & 20' W of SE corner of pad 3' BFG 2 6 118.1 27.2 29.9 90.9 94 71 80' N & 20' W of SE corner of pad 2' BFG 2 6 118.4 27.1 29.7 91.3 95 72 80' N & 20' W of SE corner of pad 1' BFG 2 6 118.0 26.9 29.5 91.1 95 73 80' N & 100' W of SE corner of pad 4' BFG 2 6 117.9 27.1 29.8 90.8 94 74 80' N & 100' W of SE corner of pad 3' BFG 2 6 118.4 27.4 30.1 91.0 95 75 80' N & 100' W of SE corner of pad 2' BFG 2 6 118.3 27.1 29.7 91.2 95 76 80' N & 100' W of SE corner of pad 1' BFG 2 6 118.2 27.3 30.0 90.9 94 77 80' N & 180' W of SE bldg. corner 4' BFG 2 6 118.4 27.0 29.5 91.4 95 78 80' N & 180' W of SE bldg. corner 3' BFG 2 6 118.2 27.1 29.8 91.1 95 79 80' N & 180' W of SE bldg. corner 2' BFG 2 6 118.3 27.0 29.6 91.3 95 80 80' N & 180' W of SE bldg. corner 1' BFG 2 6 117.9 27.1 29.9 90.8 94 81 10' N & 20' W of SE corner of pad 10' BFG 2 6 118.2 27.4 30.2 90.8 94 82 10' N & 20' W of SE corner of pad 9' BFG 2 6 117.7 27.2 30.0 90.5 94 83 10' N & 20' W of SE corner of pad 8' BFG 2 6 117.7 27.4 30.3 90.3 94 84 10' N & 20' W of SE corner of pad 7' BFG 2 6 117.9 27.3 30.1 90.6 94 85 10' N & 100' W of SE corner of pad 10' BFG 2 6 118.1 27.2 29.9 90.9 94 86 10' N & 100' W of SE corner of pad 9' BFG 2 6 118.1 27.4 30.2 90.7 94 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 3 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0007 05/17/14 05/23/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 87 10' N & 100' W of SE corner of pad 8' BFG 2 6 117.9 27.5 30.4 90.4 94 88 10' N & 100' W of SE corner of pad 7' BFG 2 6 117.8 27.2 30.0 90.6 94 89 10' N & 160' W of SE corner of pad 10' BFG 2 6 117.9 27.1 29.8 90.8 94 90 10' N & 160' W of SE corner of pad 9' BFG 2 6 117.8 27.3 30.2 90.5 94 91 10' N & 160' W of SE corner of pad 8' BFG 2 6 117.9 27.5 30.4 90.4 94 92 10' N & 160' W of SE corner of pad 7' BFG 2 6 118.0 27.3 30.1 90.7 94 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 3 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0008 05/19/14 05/27/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +3196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad 93 100' N & 20' W of SE corner of pad 10' BFG 1 6 117.6 26.5 29.1 91.1 95 94 100' N & 20' W of SE corner of pad 9' BFG 1 6 117.6 26.2 28.7 91.4 95 95 100' N & 20' W of SE corner of pad 8' BFG 1 6 117.3 26.3 28.9 91.0 95 96 100' N & 20' W of SE corner of pad 7' BFG 1 6 117.8 26.5 29.0 91.3 95 97 100' N & 100' W of SE corner of pad 10' BFG 1 6 117.7 26.6 29.2 91.1 95 98 100' N & 100' W of SE corner of pad 9' BFG 1 6 117.6 26.4 28.9 91.2 95 99 100' N & 100' W of SE corner of pad 8' BFG 1 6 118.1 26.6 29.1 91.5 95 100 100' N & 100' W of SE corner of pad 7' BFG 1 6 117.3 26.3 28.9 91.0 95 101 100' N & 180' W of SE corner of pad 10' BFG 1 6 117.7 26.3 28.8 91.4 95 102 100' N & 180' W of SE corner of pad 9' BFG 1 6 117.6 26.4 29.0 91.2 95 103 100' N & 180' W of SE corner of pad 8' BFG 1 6 117.7 26.6 29.2 91.1 95 104 100' N & 180' W of SE corner of pad 7' BFG 1 6 117.2 26.3 28.9 90.9 94 Bldg. C 105 10' N & 20' W of SE corner of pad 6' BFG 1 6 117.9 26.4 28.9 91.5 95 106 10' N & 20' W of SE corner of pad 5' BFG 1 6 117.9 26.8 29.4 91.1 95 107 10' N & 20' W of SE corner of pad 4' BFG 1 6 117.9 26.6 29.1 91.3 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0008 05/19/14 05/27/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 108 10' N & 20' W of SE corner of pad 3' BFG 1 6 118.4 26.8 29.3 91.6 95 109 10' N & 100' W of SE corner of pad 6' BFG 1 6 117.9 26.5 29.0 91.4 95 110 10' N & 100' W of SE corner of pad 5' BFG 1 6 118.4 26.8 29.3 91.6 95 111 10' N & 100' W of SE corner of pad 4' BFG 1 6 118.0 26.6 29.1 91.4 95 112 10' N & 100' W of SE corner of pad 3' BFG 1 6 118.0 26.8 29.4 91.2 95 113 10' N & 160' W of SE corner of pad 6' BFG 1 6 118.2 26.7 29.2 91.5 95 114 10' N & 160' W of SE corner of pad 5' BFG 1 6 117.6 26.3 28.8 91.3 95 115 10' N & 160' W of SE corner of pad 4' BFG 1 6 117.5 26.4 29.0 91.1 95 116 10' N & 160' W of SE corner of pad 3' BFG 1 6 118.2 26.8 29.3 91.4 95 Bldg. Pad D 117 100' N & 20' W of SE corner of pad 6' BFG 1 6 119.6 27.9 30.4 91.7 95 118 100' N & 20' W of SE corner of pad 5' BFG 1 6 119.7 27.8 30.2 91.9 96 119 100' N & 20' W of SE corner of pad 4' BFG 1 6 119.5 27.9 30.5 91.6 95 120 100' N & 100' W of SE corner of pad 6' BFG 1 6 119.5 27.7 30.2 91.8 95 121 100' N & 100' W of SE corner of pad 5' BFG 1 6 119.0 27.5 30.0 91.5 95 122 100' N & 100' W of SE corner of pad 4' BFG 1 6 119.4 27.8 30.3 91.6 95 123 100' N & 190' W of SE corner of pad 6' BFG 1 6 119.5 27.7 30.2 91.8 95 124 100' N & 190' W of SE corner of pad 5' BFG 1 6 119.6 28.0 30.6 91.6 95 125 100' N & 190' W of SE corner of pad 4' BFG 1 6 119.2 27.8 30.4 91.4 95 Bldg. C 126 10' N & 20' W of SE corner of pad 2' BFG 1 6 118.9 27.4 29.9 91.5 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0008 05/19/14 05/27/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 127 10' N & 20' W of SE corner of pad 1' BFG 1 6 118.9 27.6 30.2 91.3 95 128 10' N & 100' W of SE corner of pad 2' BFG 1 6 118.7 27.6 30.3 91.1 95 129 10' N & 100' W of SE corner of pad 1' BFG 1 6 118.8 27.4 30.0 91.4 95 130 10' N & 160' W of SE corner of pad 2' BFG 1 6 118.7 27.5 30.2 91.2 95 131 10' N & 160' W of SE corner of pad 1' BFG 1 6 119.5 27.9 30.5 91.6 95 132 50' N & 15' W of SE corner of pad 10' BFG 1 6 119.6 28.1 30.7 91.5 95 133 50' N & 15' W of SE corner of pad 9' BFG 1 6 119.8 27.9 30.4 91.9 96 134 50' N & 15' W of SE corner of pad 8' BFG 1 6 119.8 28.1 30.6 91.7 95 135 50' N & 100' W of SE corner of pad 10' BFG 1 6 119.4 27.9 30.5 91.5 95 136 50' N & 100' W of SE corner of pad 9' BFG 1 6 119.3 28.1 30.8 91.2 95 137 50' N & 100' W of SE corner of pad 8' BFG 1 6 119.5 28.0 30.6 91.5 95 138 50' N & 160' W of SE corner of pad 10' BFG 1 6 119.6 27.9 30.4 91.7 95 139 50' N & 160' W of SE corner of pad 9' BFG 1 6 118.8 27.6 30.2 91.2 95 140 50' N & 160' W of SE corner of pad 8' BFG 1 6 119.3 27.9 30.5 91.4 95 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0008 05/19/14 05/27/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 4 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0009 05/20/14 05/28/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Building Pad D 141 100' N & 20' W of the SE corner of pad 3' BFG 1 6 118.5 27.1 29.6 91.4 95 142 100' N & 20' W of the SE corner of pad 2' BFG 1 6 118.5 27.3 29.9 91.2 95 143 100' N & 20' W of the SE corner of pad 1' BFG 1 6 118.8 27.2 29.7 91.6 95 144 100' N & 100' W of the SE corner of pad 3' BFG 1 6 118.5 27.0 29.5 91.5 95 145 100' N & 100' W of the SE corner of pad 2' BFG 1 6 119.2 27.5 30.0 91.7 95 146 100' N & 100' W of the SE corner of pad 1' BFG 1 6 118.5 27.2 29.8 91.3 95 147 100' N & 190' W of the SE corner of pad 3' BFG 1 6 118.7 27.2 29.7 91.5 95 148 100' N & 190' W of the SE corner of pad 2' BFG 1 6 118.2 27.0 29.6 91.2 95 149 100' N & 190' W of the SE corner of pad 1' BFG 1 6 118.9 27.3 29.8 91.6 95 Building C 150 50' N & 15' W of the SE corner of pad 7' BFG 1 6 118.3 26.5 28.9 91.8 95 151 50' N & 15' W of the SE corner of pad 6' BFG 1 6 118.9 26.9 29.2 92.0 96 152 50' N & 15' W of the SE corner of pad 5' BFG 1 6 118.1 27.4 30.2 90.7 94 153 50' N & 15' W of the SE corner of pad 4' BFG 1 6 118.0 27.1 29.8 90.9 94 154 50' N & 15' W of the SE corner of pad 3' BFG 1 6 118.4 27.3 30.0 91.1 95 155 50' N & 90' W of the SE corner of pad 7' BFG 1 6 117.9 27.1 29.9 90.8 94 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 3 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0009 05/20/14 05/28/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 156 50' N & 90' W of the SE corner of pad 6' BFG 1 6 118.7 27.5 30.2 91.2 95 157 50' N & 90' W of the SE corner of pad 5' BFG 1 6 118.7 27.7 30.4 91.0 95 158 50' N & 90' W of the SE corner of pad 4' BFG 1 6 118.0 27.3 30.1 90.7 94 159 50' N & 90' W of the SE corner of pad 3' BFG 1 6 118.4 27.5 30.3 90.9 94 160 50' N & 160' W of the SE corner of pad 7' BFG 1 6 118.4 27.2 29.8 91.2 95 161 50' N & 160' W of the SE corner of pad 6' BFG 1 6 118.1 27.3 30.1 90.8 94 162 50' N & 160' W of the SE corner of pad 5' BFG 1 6 118.1 27.5 30.4 90.6 94 163 50' N & 160' W of the SE corner of pad 4' BFG 1 6 118.3 27.4 30.1 90.9 94 164 50' N & 160' W of the SE corner of pad 3' BFG 1 6 118.2 27.5 30.3 90.7 94 Building D 165 120' N & 20' W of the SE corner of pad 10' BFG 1 6 119.0 27.4 29.9 91.6 95 166 120' N & 20' W of the SE corner of pad 9' BFG 1 6 118.9 27.6 30.2 91.3 95 167 120' N & 20' W of the SE corner of pad 8' BFG 1 6 119.0 27.5 30.0 91.5 95 168 120' N & 20' W of the SE corner of pad 7' BFG 1 6 118.9 27.7 30.4 91.2 95 169 120' N & 100' W of the SE corner of pad 10' BFG 1 6 118.4 27.3 30.0 91.1 95 170 120' N & 100' W of the SE corner of pad 9' BFG 1 6 118.3 27.5 30.3 90.8 94 171 120' N & 100' W of the SE corner of pad 8' BFG 1 6 119.0 27.8 30.5 91.2 95 172 120' N & 100' W of the SE corner of pad 7' BFG 1 6 119.2 27.8 30.4 91.4 95 173 120' N & 180' W of the SE corner of pad 10' BFG 1 6 119.3 28.1 30.8 91.2 95 174 120' N & 180' W of the SE corner of pad 9' BFG 1 6 119.2 27.9 30.6 91.3 95 175 120' N & 180' W of the SE corner of pad 8' BFG 1 6 118.7 27.7 30.4 91.0 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 3 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0009 05/20/14 05/28/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 176 120' N & 180' W of the SE corner of pad 7' BFG 1 6 118.6 27.7 30.5 90.9 94 Building Pad C 177 50' N & 20' W of the SE corner of pad 2' BFG 1 6 118.3 27.2 29.9 91.1 95 178 50' N & 20' W of the SE corner of pad 1' BFG 1 6 119.0 27.6 30.2 91.4 95 179 50' N & 90' W of the SE corner of pad 2' BFG 1 6 119.6 27.9 30.4 91.7 95 180 50' N & 90' W of the SE corner of pad 1' BFG 1 6 119.0 27.5 30.1 91.5 95 181 50' N & 160' W of the SE corner of pad 2' BFG 1 6 119.0 27.7 30.3 91.3 95 182 50' N & 160' W of the SE corner of pad 1' BFG 1 6 119.1 27.5 30.0 91.6 95 Comments: Datum:BFG = below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 3 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0010 05/21/14 05/29/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad D 183 120' N & 20' W of Se corner of pad 6' BFG 1 6 120.1 28.2 30.7 91.9 96 184 120' N & 20' W of Se corner of pad 5' BFG 1 6 119.7 28.0 30.5 91.7 95 185 120' N & 20' W of Se corner of pad 4' BFG 1 6 119.3 27.8 30.4 91.5 95 186 120' N & 20' W of Se corner of pad 3' BFG 1 6 119.9 28.1 30.6 91.8 95 187 120' N & 100' W of SE corner of pad 6' BFG 1 6 119.0 27.4 29.9 91.6 95 188 120' N & 100' W of SE corner of pad 5' BFG 1 6 119.1 27.7 30.3 91.4 95 189 120' N & 100' W of SE corner of pad 4' BFG 1 6 118.8 27.5 30.1 91.3 95 190 120' N & 100' W of SE corner of pad 3' BFG 1 6 119.3 27.8 30.4 91.5 95 191 120' N & 180' W of SE corner of pad 6' BFG 1 6 119.2 27.5 30.0 91.7 95 192 120' N & 180' W of SE corner of pad 5' BFG 1 6 118.8 27.3 29.8 91.5 95 193 120' N & 180' W of SE corner of pad 4' BFG 1 6 119.3 27.7 30.2 91.6 95 194 120' N & 180' W of SE corner of pad 3' BFG 1 6 118.9 27.5 30.1 91.4 95 195 80' N & 20' W of SE corner of pad 10' BFG 1 6 118.6 27.2 29.8 91.4 95 196 80' N & 20' W of SE corner of pad 9' BFG 1 6 118.5 27.5 30.2 91.0 95 197 80' N & 20' W of SE corner of pad 8' BFG 1 6 118.7 27.4 30.0 91.3 95 198 80' N & 20' W of SE corner of pad 7' BFG 1 6 118.7 27.6 30.3 91.1 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0010 05/21/14 05/29/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 199 80' N & 90' W of SE corner of pad 10' BFG 1 6 118.5 27.3 29.9 91.2 95 200 80' N & 90' W of SE corner of pad 9' BFG 1 6 118.5 27.6 30.4 90.9 94 201 80' N & 90' W of SE corner of pad 8' BFG 1 6 118.5 27.4 30.1 91.1 95 202 80' N & 90' W of SE corner of pad 7' BFG 1 6 119.0 27.7 30.3 91.3 95 203 80' N & 160' W of SE corner of pad 10' BFG 1 6 118.8 27.2 29.7 91.6 95 204 80' N & 160' W of SE corner of pad 9' BFG 1 6 118.5 27.3 29.9 91.2 95 205 80' N & 160' W of SE corner of pad 8' BFG 1 6 119.0 27.6 30.2 91.4 95 206 80' N & 160' W of SE corner of pad 7' BFG 1 6 118.8 27.7 30.4 91.1 95 Bldg. Pad C 207 80' N & 20' W of SE corner of pad 6' BFG 1 6 119.7 28.4 31.1 91.3 95 208 80' N & 20' W of SE corner of pad 5' BFG 1 6 119.9 28.3 30.9 91.6 95 209 80' N & 20' W of SE corner of pad 4' BFG 1 6 119.7 28.5 31.2 91.2 95 210 80' N & 20' W of SE corner of pad 3' BFG 1 6 119.5 28.1 30.7 91.4 95 211 80' N & 90' W of SE corner of pad 6' BFG 1 6 119.9 28.4 31.0 91.5 95 212 80' N & 90' W of SE corner of pad 5' BFG 1 6 119.9 28.2 30.8 91.7 95 213 80' N & 90' W of SE corner of pad 4' BFG 1 6 119.8 28.5 31.2 91.3 95 214 80' N & 90' W of SE corner of pad 3' BFG 1 6 119.7 28.6 31.4 91.1 95 215 80' N & 160' W of SE corner of pad 6' BFG 1 6 119.9 28.5 31.2 91.4 95 216 80' N & 160' W of SE corner of pad 5' BFG 1 6 119.9 28.7 31.5 91.2 95 217 80' N & 160' W of SE corner of pad 4' BFG 1 6 119.5 28.5 31.3 91.0 95 218 80' N & 160' W of SE corner of pad 3' BFG 1 6 120.2 28.9 31.6 91.3 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0010 05/21/14 05/29/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad D 219 120' N & 20' W of SE corner of pad 2' BFG 1 6 119.3 28.1 30.8 91.2 95 220 120' N & 20' W of SE corner of pad 1' BFG 1 6 119.5 28.0 30.6 91.5 95 221 120' N & 100' W of SE corner pad 2' BFG 1 6 119.5 28.2 30.9 91.3 95 222 120' N & 100' W of SE corner pad 1' BFG 1 6 119.1 28.0 30.7 91.1 95 223 120' N & 190' W of SE corner of pad 2' BFG 1 6 119.7 28.3 31.0 91.4 95 224 120' N & 190' W of SE corner of pad 1' BFG 1 6 119.1 28.1 30.9 91.0 95 Bldg. Pad C 225 80' N & 20' W of SE corner of pad 2' BFG 1 6 119.7 28.5 31.2 91.2 95 226 80' N & 20' W of SE corner of pad 1' BFG 1 6 119.1 28.2 31.0 90.9 94 227 80' N & 90' W of SE corner of pad 2' BFG 1 6 119.1 28.0 30.7 91.1 95 228 80' N & 90' W of SE corner of pad 1' BFG 1 6 119.5 28.2 30.9 91.3 95 229 80' N & 160' W of SE corner of pad 2' BFG 1 6 118.8 27.8 30.6 91.0 95 230 80' N & 160' W of SE corner of pad 1' BFG 1 6 119.6 28.2 30.8 91.4 95 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0010 05/21/14 05/29/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 4 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0011 05/22/14 05/30/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad C 231 100' N & 20' W of SE corner of pad 10' BFG 1 6 119.4 28.1 30.8 91.3 95 232 100' N & 20' W of SE corner of pad 9' BFG 1 6 119.5 28.0 30.6 91.5 95 233 100' N & 20' W of SE corner of pad 8' BFG 1 6 119.6 27.9 30.4 91.7 95 234 100' N & 20' W of SE corner of pad 7' BFG 1 6 119.5 28.1 30.7 91.4 95 235 100' N & 20' W of SE corner of pad 6' BFG 1 6 119.8 28.0 30.5 91.8 95 236 100' N & 20' W of SE corner of pad 5' BFG 1 6 119.6 28.0 30.6 91.6 95 237 100' N & 90' W of SE corner of pad 10' BFG 1 6 119.6 28.1 30.7 91.5 95 238 100' N & 90' W of SE corner of pad 9' BFG 1 6 119.6 27.9 30.4 91.7 95 239 100' N & 90' W of SE corner of pad 8' BFG 1 6 119.5 27.9 30.5 91.6 95 240 100' N & 90' W of SE corner of pad 7' BFG 1 6 119.6 28.2 30.8 91.4 95 241 100' N & 90' W of SE corner of pad 6' BFG 1 6 119.7 28.1 30.7 91.6 95 242 100' N & 90' W of SE corner of pad 5' BFG 1 6 119.7 27.9 30.4 91.8 95 243 100' N & 160' W of SE corner of pad 10' BFG 1 6 119.3 28.1 30.8 91.2 95 244 100' N & 160' W of SE corner of pad 9' BFG 1 6 118.8 27.8 30.6 91.0 95 245 100' N & 160' W of SE corner of pad 8' BFG 1 6 119.1 27.7 30.3 91.4 95 246 100' N & 160' W of SE corner of pad 7' BFG 1 6 119.3 28.0 30.7 91.3 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0011 05/22/14 05/30/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 247 100' N & 160' W of SE corner of pad 6' BFG 1 6 119.3 27.8 30.4 91.5 95 248 100' N & 160' W of SE corner of pad 5' BFG 1 6 118.9 27.8 30.5 91.1 95 Bldg. Pad D 249 150' N & 20' W of SE corner of pad 10' BFG 1 6 118.0 27.1 29.8 90.9 94 250 150' N & 20' W of SE corner of pad 9' BFG 1 6 118.1 27.4 30.2 90.7 94 251 150' N & 20' W of SE corner of pad 8' BFG 1 6 118.4 27.3 30.0 91.1 95 252 150' N & 20' W of SE corner of pad 7' BFG 1 6 119.6 27.8 30.3 91.8 95 253 150' N & 20' W of SE corner of pad 6' BFG 1 6 118.4 27.4 30.1 91.0 95 254 150' N & 100' W of SE corner of pad 10' BFG 1 6 118.7 27.7 30.4 91.0 95 255 150' N & 100' W of SE corner of pad 9' BFG 1 6 118.9 27.5 30.1 91.4 95 256 150' N & 100' W of SE corner of pad 8' BFG 1 6 118.8 27.6 30.3 91.2 95 257 150' N & 100' W of SE corner of pad 7' BFG 1 6 118.2 27.3 30.0 90.9 94 258 150' N & 100' W of SE corner of pad 6' BFG 1 6 118.9 27.8 30.5 91.1 95 259 150' N & 190' W of SE corner of pad 10' BFG 1 6 118.9 27.7 30.4 91.2 95 260 150' N & 190' W of SE corner of pad 9' BFG 1 6 119.0 27.6 30.2 91.4 95 261 150' N & 190' W of SE corner of pad 8' BFG 1 6 118.8 27.8 30.5 91.0 95 262 150' N & 190' W of SE corner of pad 7' BFG 1 6 118.8 27.6 30.3 91.2 95 263 150' N & 190' W of SE corner of pad 6' BFG 1 6 118.8 27.8 30.6 91.0 95 Bldg. Pad C 264 100' N & 20' W of SE corner of pad 4' BFG 1 6 117.9 27.0 29.7 90.9 94 265 100' N & 20' W of SE corner of pad 3' BFG 1 6 117.7 27.1 29.9 90.6 94 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0011 05/22/14 05/30/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 266 100' N & 20' W of SE corner of pad 2' BFG 1 6 118.3 27.5 30.3 90.8 94 267 100' N & 20' W of SE corner of pad 1' BFG 1 6 118.4 27.3 30.0 91.1 95 268 100' N & 80' W of SE corner of pad 4' BFG 1 6 118.9 27.7 30.4 91.2 95 269 100' N & 80' W of SE corner of pad 3' BFG 1 6 118.0 27.2 30.0 90.8 94 270 100' N & 80' W of SE corner of pad 2' BFG 1 6 118.5 27.5 30.2 91.0 95 271 100' N & 80' W of SE corner of pad 1' BFG 1 6 118.6 27.3 29.9 91.3 95 272 100' N & 150' W of SE corner of pad 4' BFG 1 6 118.4 27.6 30.4 90.8 94 273 100' N & 150' W of SE corner of pad 3' BFG 1 6 118.5 27.4 30.1 91.1 95 274 100' N & 150' W of SE corner of pad 2' BFG 1 6 118.4 27.5 30.3 90.9 94 275 100' N & 150' W of SE corner of pad 1' BFG 1 6 119.0 27.7 30.3 91.3 95 Bldg. Pad D 276 150' N & 20' W of SE corner of pad 5' BFG 1 6 119.7 27.9 30.4 91.8 95 277 150' N & 20' W of SE corner of pad 4' BFG 1 6 119.3 27.6 30.1 91.7 95 278 150' N & 20' W of SE corner of pad 3' BFG 1 6 119.1 27.6 30.2 91.5 95 279 150' N & 20' W of SE corner of pad 2' BFG 1 6 119.7 28.0 30.5 91.7 95 280 150' N & 20' W of SE corner of pad 1' BFG 1 6 119.1 27.5 30.0 91.6 95 281 150' N & 100' W of SE corner of pad 5' BFG 1 6 117.9 27.0 29.7 90.9 94 282 150' N & 100' W of SE corner of pad 4' BFG 1 6 118.7 27.3 29.9 91.4 95 283 150' N & 100' W of SE corner of pad 3' BFG 1 6 119.4 27.7 30.2 91.7 95 284 150' N & 100' W of SE corner of pad 2' BFG 1 6 118.8 27.4 30.0 91.4 95 285 150' N & 100' W of SE corner of pad 1' BFG 1 6 119.2 27.7 30.3 91.5 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0011 05/22/14 05/30/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 286 150' N & 180' W of SE corner of pad 5' BFG 1 6 118.7 27.5 30.1 91.2 95 287 150' N & 180' W of SE corner of pad 4' BFG 1 6 118.8 27.7 30.4 91.1 95 288 150' N & 180' W of SE corner of pad 3' BFG 1 6 119.1 27.8 30.5 91.3 95 289 150' N & 180' W of SE corner of pad 2' BFG 1 6 118.6 27.6 30.3 91.0 95 290 150' N & 180' W of SE corner of pad 1' BFG 1 6 119.2 27.8 30.4 91.4 95 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 4 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0012 05/23/14 05/30/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Building Pad C 291 120' N & 20' W of the SE corner of pad 10' BFG 1 6 119.5 27.7 30.2 91.8 95 292 120' N & 20' W of the SE corner of pad 9' BFG 1 6 119.0 27.5 30.0 91.5 95 293 120' N & 20' W of the SE corner of pad 8' BFG 1 6 119.5 27.8 30.3 91.7 95 294 120' N & 20' W of the SE corner of pad 7' BFG 1 6 119.0 27.4 29.9 91.6 95 295 120' N & 80' W of the SE corner of pad 10' BFG 1 6 119.6 27.9 30.4 91.7 95 296 120' N & 80' W of the SE corner of pad 9' BFG 1 6 119.0 27.6 30.2 91.4 95 297 120' N & 80' W of the SE corner of pad 8' BFG 1 6 119.5 27.9 30.5 91.6 95 298 120' N & 80' W of the SE corner of pad 7' BFG 1 6 119.0 27.5 30.1 91.5 95 299 120' N & 150' W of the SE corner of pad 10' BFG 1 6 119.6 28.0 30.6 91.6 95 300 120' N & 150' W of the SE corner of pad 9' BFG 1 6 119.1 27.8 30.4 91.3 95 301 120' N & 150' W of the SE corner of pad 8' BFG 1 6 119.2 27.7 30.3 91.5 95 302 120' N & 150' W of the SE corner of pad 7' BFG 1 6 119.8 28.0 30.5 91.8 95 Building Pad D 303 180' N & 20' W of the SE corner of pad 10' BFG 1 6 118.5 28.3 31.4 90.2 94 304 180' N & 20' W of the SE corner of pad 9' BFG 1 6 118.6 28.1 31.1 90.5 94 305 180' N & 20' W of the SE corner of pad 8' BFG 1 6 118.8 28.5 31.6 90.3 94 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0012 05/23/14 05/30/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 306 180' N & 20' W of the SE corner of pad 7' BFG 1 6 118.5 28.4 31.5 90.1 94 307 180' N & 100' W of the SE corner of pad 10' BFG 1 6 119.1 28.7 31.7 90.4 94 308 180' N & 100' W of the SE corner of pad 9' BFG 1 6 118.5 28.3 31.4 90.2 94 309 180' N & 100' W of the SE corner of pad 8' BFG 1 6 119.2 28.6 31.6 90.6 94 310 180' N & 100' W of the SE corner of pad 7' BFG 1 6 119.0 28.7 31.8 90.3 94 311 180' N 7 180' W of the SE corner of pad 10' BFG 1 6 119.5 28.8 31.7 90.7 94 312 180' N 7 180' W of the SE corner of pad 9' BFG 1 6 119.0 28.5 31.5 90.5 94 313 180' N 7 180' W of the SE corner of pad 8' BFG 1 6 119.2 28.8 31.9 90.4 94 314 180' N 7 180' W of the SE corner of pad 7' BFG 1 6 118.8 28.6 31.7 90.2 94 Comments: Datum:BFG = below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0013 05/24/14 06/02/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad C 315 720' N & 20' W of SE corner of pad 6' BFG 1 6 119.7 28.0 30.5 91.7 95 316 720' N & 20' W of SE corner of pad 5' BFG 1 6 119.1 27.6 30.2 91.5 95 317 720' N & 20' W of SE corner of pad 4' BFG 1 6 118.8 27.4 30.0 91.4 95 318 720' N & 20' W of SE corner of pad 3' BFG 1 6 119.4 27.8 30.4 91.6 95 319 720' N & 20' W of SE corner of pad 2' BFG 1 6 118.8 27.5 30.1 91.3 95 320 720' N & 20' W of SE corner of pad 1' BFG 1 6 119.2 27.7 30.3 91.5 95 321 120' N & 80' W of SE corner of pad 6' BFG 1 6 118.6 27.4 30.0 91.2 95 322 120' N & 80' W of SE corner of pad 5' BFG 1 6 119.1 27.7 30.3 91.4 95 323 120' N & 80' W of SE corner of pad 4' BFG 1 6 118.9 27.7 30.4 91.2 95 324 120' N & 80' W of SE corner of pad 3' BFG 1 6 119.1 27.6 30.2 91.5 95 325 120' N & 80' W of SE corner of pad 2' BFG 1 6 119.7 28.0 30.5 91.7 95 326 120' N & 80' W of SE corner of pad 1' BFG 1 6 119.5 28.1 30.7 91.4 95 327 120' N & 150' W of SE corner of pad 6' BFG 1 6 119.0 27.9 30.6 91.1 95 328 120' N & 150' W of SE corner of pad 5' BFG 1 6 119.0 27.6 30.2 91.4 95 329 120' N & 150' W of SE corner of pad 4' BFG 1 6 119.7 27.9 30.4 91.8 95 330 120' N & 150' W of SE corner of pad 3' BFG 1 6 119.5 27.9 30.5 91.6 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0013 05/24/14 06/02/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 331 120' N & 150' W of SE corner of pad 2' BFG 1 6 118.8 27.5 30.1 91.3 95 332 120' N & 150' W of SE corner of pad 1' BFG 1 6 119.2 27.7 30.3 91.5 95 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0014 05/27/14 06/03/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad C 333 150' N & 20' W of SE corner of pad 10' BFG 1 6 119.6 28.7 31.6 90.9 94 334 150' N & 20' W of SE corner of pad 9' BFG 1 6 119.3 28.8 31.8 90.5 94 335 150' N & 20' W of SE corner of pad 8' BFG 1 6 118.9 28.5 31.5 90.4 94 336 150' N & 20' W of SE corner of pad 7' BFG 1 6 119.5 28.8 31.7 90.7 94 337 150' N & 80' W of SE corner of pad 10' BFG 1 6 119.7 29.1 32.1 90.6 94 338 150' N & 80' W of SE corner of pad 9' BFG 1 6 119.7 28.9 31.8 90.8 94 339 150' N & 80' W of SE corner of pad 8' BFG 1 6 119.1 28.6 31.6 90.5 94 340 150' N & 80' W of SE corner of pad 7' BFG 1 6 119.2 28.9 32.0 90.3 94 341 150' N & 150' W of SE corner of pad 10' BFG 1 6 119.4 28.8 31.8 90.6 94 342 150' N & 150' W of SE corner of pad 9' BFG 1 6 119.5 28.6 31.5 90.9 94 343 150' N & 150' W of SE corner of pad 8' BFG 1 6 119.6 28.9 31.9 90.7 94 344 150' N & 150' W of SE corner of pad 7' BFG 1 6 119.5 29.1 32.2 90.4 94 345 150' N & 20' W of SE corner of pad 6' BFG 1 6 119.6 27.9 30.4 91.7 95 346 150' N & 20' W of SE corner of pad 5' BFG 1 6 119.2 28.0 30.7 91.2 95 347 150' N & 20' W of SE corner of pad 4' BFG 1 6 119.4 27.9 30.5 91.5 95 348 150' N & 20' W of SE corner of pad 3' BFG 1 6 118.7 27.6 30.3 91.1 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0014 05/27/14 06/03/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 349 150' N & 80' W of SE corner of pad 6' BFG 1 6 119.4 28.0 30.6 91.4 95 350 150' N & 80' W of SE corner of pad 5' BFG 1 6 119.5 27.9 30.5 91.6 95 351 150' N & 80' W of SE corner of pad 4' BFG 1 6 119.0 27.7 30.3 91.3 95 352 150' N & 80' W of SE corner of pad 3' BFG 1 6 119.9 28.1 30.6 91.8 95 353 150' N & 150' W of SE corner 6' BFG 1 6 119.1 28.1 30.9 91.0 95 354 150' N & 150' W of SE corner 5' BFG 1 6 119.5 28.1 30.7 91.4 95 355 150' N & 150' W of SE corner 4' BFG 1 6 119.0 27.8 30.5 91.2 95 356 150' N & 150' W of SE corner 3' BFG 1 6 119.7 28.2 30.8 91.5 95 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0015 05/28/14 06/03/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 92-98>/= +4295.324.294141126.0001 Dark brown clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad C 357 150' N & 20' W of SE corner of pad 2' BFG 1 6 119.2 28.5 31.4 90.7 94 358 150' N & 20' W of SE corner of pad 1' BFG 1 6 118.5 28.1 31.1 90.4 94 359 150' N & 80' W of SE corner of pad 2' BFG 1 6 118.8 28.3 31.3 90.5 94 360 150' N & 80' W of SE corner of pad 1' BFG 1 6 118.7 28.4 31.5 90.3 94 361 150' N & 150' W of SE corner of pad 2' BFG 1 6 118.2 28.1 31.2 90.1 94 362 150' N & 150' W of SE corner of pad 1' BFG 1 6 119.0 28.6 31.6 90.4 94 363 180' N & 20' W of SE corner of pad 10' BFG 1 6 119.3 28.1 30.8 91.2 95 364 180' N & 20' W of SE corner of pad 9' BFG 1 6 119.5 28.0 30.6 91.5 95 365 180' N & 20' W of SE corner of pad 8' BFG 1 6 119.2 28.1 30.9 91.1 95 366 180' N & 20' W of SE corner of pad 7' BFG 1 6 118.8 27.8 30.6 91.0 95 367 180' N & 80' W of SE corner of pad 10' BFG 1 6 119.3 27.9 30.5 91.4 95 368 180' N & 80' W of SE corner of pad 9' BFG 1 6 119.2 28.0 30.7 91.2 95 369 180' N & 80' W of SE corner of pad 8' BFG 1 6 119.6 28.2 30.8 91.4 95 370 180' N & 80' W of SE corner of pad 7' BFG 1 6 118.8 27.8 30.6 91.0 95 371 180' N & 150' W of SE corner of pad 10' BFG 1 6 119.8 28.3 30.9 91.5 95 372 180' N & 80' W of SE corner of pad 9' BFG 1 6 119.2 28.0 30.7 91.2 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0015 05/28/14 06/03/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 373 180' N & 80' W of SE corner of pad 8' BFG 1 6 119.4 28.0 30.6 91.4 95 374 180' N & 150' W of SE corner of pad 7' BFG 1 6 119.2 28.1 30.8 91.1 95 Bldg. Pad D 375 180' N & 20' W of SE corner of pad 6' BFG 2 6 117.7 27.2 30.0 90.5 95 376 180' N & 20' W of SE corner of pad 5' BFG 2 6 118.4 27.6 30.4 90.8 95 377 180' N & 20' W of SE corner of pad 4' BFG 2 6 118.3 27.7 30.6 90.6 95 378 180' N & 20' W of SE corner of pad 3' BFG 2 6 118.4 27.5 30.3 90.9 95 379 180' N & 20' W of SE corner of pad 2' BFG 2 6 118.4 27.7 30.5 90.7 95 380 180' N & 20' W of SE corner of pad 1' BFG 2 6 118.0 27.4 30.2 90.6 95 381 180' N & 100' W of SE corner of pad 6' BFG 2 6 118.7 27.9 30.7 90.8 95 382 180' N & 100' W of SE corner of pad 5' BFG 2 6 118.0 27.6 30.5 90.4 95 383 180' N & 100' W of SE corner of pad 4' BFG 2 6 118.2 27.5 30.3 90.7 95 384 180' N & 100' W of SE corner of pad 3' BFG 2 6 118.2 27.7 30.6 90.5 95 385 180' N & 100' W of SE corner of pad 2' BFG 2 6 118.1 27.8 30.8 90.3 95 386 180' N & 100' W of SE corner of pad 1' BFG 2 6 118.2 27.6 30.5 90.6 95 387 180' N & 108' W of SE corner of pad 6' BFG 2 6 118.1 27.6 30.5 90.5 95 388 180' N & 108' W of SE corner of pad 5' BFG 2 6 118.1 27.4 30.2 90.7 95 389 180' N & 108' W of SE corner of pad 4' BFG 2 6 118.5 27.6 30.4 90.9 95 390 180' N & 108' W of SE corner of pad 3' BFG 2 6 117.9 27.3 30.1 90.6 95 391 180' N & 108' W of SE corner of pad 2' BFG 2 6 117.8 27.4 30.3 90.4 95 392 180' N & 108' W of SE corner of pad 1' BFG 2 6 118.5 27.8 30.6 90.7 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0015 05/28/14 06/03/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad C 393 180' N & 20' W of SE corner of pad 6' BFG 1 6 117.8 27.1 29.9 90.7 94 394 180' N & 20' W of SE corner of pad 5' BFG 1 6 117.9 27.0 29.7 90.9 94 395 180' N & 20' W of SE corner of pad 4' BFG 1 6 118.4 27.2 29.8 91.2 95 396 180' N & 20' W of SE corner of pad 3' BFG 1 6 117.9 26.9 29.6 91.0 95 397 180' N & 20' W of SE corner of pad 2' BFG 1 6 118.4 27.1 29.7 91.3 95 398 180' N & 20' W of SE corner of pad 1' BFG 1 6 118.2 27.4 30.2 90.8 94 399 180' N & 80' W of SE corner of pad 6' BFG 1 6 117.5 26.8 29.6 90.7 94 400 180' N & 80' W of SE corner of pad 5' BFG 1 6 117.5 26.6 29.3 90.9 94 401 180' N & 80' W of SE corner of pad 4' BFG 1 6 118.1 26.9 29.5 91.2 95 402 180' N & 80' W of SE corner of pad 3' BFG 1 6 117.8 26.8 29.4 91.0 95 403 180' N & 80' W of SE corner of pad 2' BFG 1 6 117.8 27.0 29.7 90.8 94 404 180' N & 80' W of SE corner of pad 1' BFG 1 6 117.1 26.5 29.3 90.6 94 405 180' N & 150' W of SE corner of pad 6' BFG 1 6 118.0 27.2 30.0 90.8 94 406 180' N & 150' W of SE corner of pad 5' BFG 1 6 117.6 27.0 29.8 90.6 94 407 180' N & 150' W of SE corner of pad 4' BFG 1 6 117.8 26.9 29.6 90.9 94 408 180' N & 150' W of SE corner of pad 3' BFG 1 6 118.3 27.2 29.9 91.1 95 409 180' N & 150' W of SE corner of pad 2' BFG 1 6 117.6 26.9 29.7 90.7 94 410 180' N & 150' W of SE corner of pad 1' BFG 1 6 118.0 27.1 29.8 90.9 94 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0015 05/28/14 06/03/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 4 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0016 05/29/14 06/05/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Building Pad C 411 200' N 720' W of the SE corner of pad 10' BFG 1 6 119.8 28.3 30.9 91.5 95 412 200' N 720' W of the SE corner of pad 9' BFG 1 6 118.8 27.8 30.6 91.0 95 413 200' N 720' W of the SE corner of pad 8' BFG 1 6 119.3 28.1 30.8 91.2 95 414 200' N 720' W of the SE corner of pad 7' BFG 1 6 119.1 28.0 30.7 91.1 95 415 200' N 720' W of the SE corner of pad 6' BFG 1 6 119.3 27.9 30.5 91.4 95 416 200' N & 80' W of the SE corner of pad 10' BFG 1 6 119.3 28.0 30.7 91.3 95 417 200' N & 80' W of the SE corner of pad 9' BFG 1 6 119.4 27.8 30.4 91.6 95 418 200' N & 80' W of the SE corner of pad 8' BFG 1 6 119.6 28.2 30.8 91.4 95 419 200' N & 80' W of the SE corner of pad 7' BFG 1 6 119.5 28.0 30.6 91.5 95 420 200' N & 80' W of the SE corner of pad 6' BFG 1 6 119.8 28.0 30.5 91.8 95 421 200' N & 150' W of the SE corner of pad 10' BFG 1 6 119.4 28.3 31.1 91.1 95 422 200' N & 150' W of the SE corner of pad 9' BFG 1 6 119.4 28.1 30.8 91.3 95 423 200' N & 150' W of the SE corner of pad 8' BFG 1 6 119.4 28.0 30.6 91.4 95 424 200' N & 150' W of the SE corner of pad 7' BFG 1 6 119.4 28.2 30.9 91.2 95 425 200' N & 150' W of the SE corner of pad 6' BFG 1 6 119.6 28.1 30.7 91.5 95 Building Pad D The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0016 05/29/14 06/05/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 426 200' N & 20' W of the SE corner of pad 10' BFG 1 6 117.8 27.0 29.7 90.8 94 427 200' N & 20' W of the SE corner of pad 9' BFG 1 6 118.5 27.3 29.9 91.2 95 428 200' N & 20' W of the SE corner of pad 8' BFG 1 6 117.8 26.8 29.5 91.0 95 429 200' N & 100' W of the SE corner of pad 10' BFG 1 6 117.7 27.0 29.8 90.7 94 430 200' N & 100' W of the SE corner of pad 9' BFG 1 6 117.8 26.9 29.6 90.9 94 431 200' N & 100' W of the SE corner of pad 8' BFG 1 6 118.4 27.3 30.0 91.1 95 432 200' N & 180' W of the SE corner of pad 10' BFG 1 6 117.9 27.1 29.9 90.8 94 433 200' N & 180' W of the SE corner of pad 9' BFG 1 6 118.0 27.4 30.2 90.6 94 434 200' N & 180' W of the SE corner of pad 8' BFG 1 6 118.0 27.1 29.8 90.9 94 Building Pad C 435 200' N & 20' W of the SE corner of pad 5' BFG 1 6 119.3 28.1 30.8 91.2 95 436 200' N & 20' W of the SE corner of pad 4' BFG 1 6 119.5 28.0 30.6 91.5 95 437 200' N & 20' W of the SE corner of pad 3' BFG 1 6 119.2 28.1 30.9 91.1 95 438 200' N & 20' W of the SE corner of pad 2' BFG 1 6 119.3 28.0 30.7 91.3 95 439 200' N & 20' W of the SE corner of pad 1' BFG 1 6 118.7 27.7 30.4 91.0 95 440 200' N & 80' W of the SE corner of pad 5' BFG 1 6 119.1 28.0 30.7 91.1 95 441 200' N & 80' W of the SE corner of pad 4' BFG 1 6 118.5 27.7 30.5 90.8 94 442 200' N & 80' W of the SE corner of pad 3' BFG 1 6 118.0 27.4 30.2 90.6 94 443 200' N & 80' W of the SE corner of pad 2' BFG 1 6 118.7 27.8 30.6 90.9 94 444 200' N & 80' W of the SE corner of pad 1' BFG 1 6 118.3 27.6 30.4 90.7 94 445 200' N & 150' W of the SE corner of pad 5' BFG 1 6 119.0 27.8 30.5 91.2 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0016 05/29/14 06/05/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 446 200' N & 150' W of the SE corner of pad 4' BFG 1 6 118.4 27.5 30.2 90.9 94 447 200' N & 150' W of the SE corner of pad 3' BFG 1 6 118.6 27.8 30.6 90.8 94 448 200' N & 150' W of the SE corner of pad 2' BFG 1 6 118.2 27.5 30.3 90.7 94 449 200' N & 150' W of the SE corner of pad 1' BFG 1 6 118.8 27.8 30.5 91.0 95 Building Pad D 450 200' N & 20' W of the SE corner of pad 7' BFG 1 6 119.0 27.4 29.9 91.6 95 451 200' N & 20' W of the SE corner of pad 6' BFG 1 6 119.1 27.3 29.7 91.8 95 452 200' N & 20' W of the SE corner of pad 5' BFG 1 6 119.0 27.5 30.1 91.5 95 453 200' N & 100' W of the SE corner of pad 7' BFG 1 6 118.6 27.2 29.8 91.4 95 454 200' N & 100' W of the SE corner of pad 6' BFG 1 6 119.2 27.5 30.0 91.7 95 455 200' N & 100' W of the SE corner of pad 5' BFG 1 6 118.4 27.1 29.7 91.3 95 456 200' N & 180' W of the SE corner of pad 7' BFG 1 6 118.6 27.0 29.5 91.6 95 457 200' N & 180' W of the SE corner of pad 6' BFG 1 6 118.5 27.2 29.8 91.3 95 458 200' N & 180' W of the SE corner of pad 5' BFG 1 6 118.4 26.9 29.4 91.5 95 Building Pad C 459 230' N & 20' W of the SE corner of pad 10' BFG 1 6 119.3 27.8 30.4 91.5 95 460 230' N & 20' W of the SE corner of pad 9' BFG 1 6 118.7 27.5 30.1 91.2 95 461 230' N & 20' W of the SE corner of pad 8' BFG 1 6 119.4 27.8 30.3 91.6 95 462 230' N & 20' W of the SE corner of pad 7' BFG 1 6 118.7 27.4 30.0 91.3 95 463 230' N & 80' W of the SE corner of pad 10' BFG 1 6 119.1 28.0 30.7 91.1 95 464 230' N & 80' W of the SE corner of pad 9' BFG 1 6 119.2 27.8 30.4 91.4 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0016 05/29/14 06/05/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 465 230' N & 80' W of the SE corner of pad 8' BFG 1 6 119.1 27.9 30.6 91.2 95 466 230' N & 80' W of the SE corner of pad 7' BFG 1 6 119.5 27.9 30.5 91.6 95 467 230' N & 150' W of the SE corner of pad 10' BFG 1 6 118.9 28.0 30.8 90.9 94 468 230' N & 150' W of the SE corner of pad 9' BFG 1 6 119.1 27.9 30.6 91.2 95 469 230' N & 150' W of the SE corner of pad 8' BFG 1 6 118.6 27.6 30.3 91.0 95 470 230' N & 150' W of the SE corner of pad 7' BFG 1 6 118.5 27.8 30.7 90.7 94 Comments: Datum:BFG = below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 4 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0017 05/30/14 06/06/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92 - 98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad C 471 230' N & 20' W of SE corner of pad 6' BFG 1 6 118.4 27.4 30.1 91.0 95 472 230' N & 20' W of SE corner of pad 5' BFG 1 6 118.6 27.2 29.8 91.4 95 473 230' N & 20' W of SE corner of pad 4' BFG 1 6 118.2 27.1 29.7 91.1 95 474 230' N & 20' W of SE corner of pad 3' BFG 1 6 118.9 27.4 29.9 91.5 95 475 230' N & 20' W of SE corner of pad 2' BFG 1 6 118.4 27.5 30.2 90.9 94 476 230' N & 20' W of SE corner of pad 1' BFG 1 6 118.7 27.4 30.0 91.3 95 477 230' N & 80' W of SE corner of pad 6' BFG 1 6 118.7 27.3 29.9 91.4 95 478 230' N & 80' W of SE corner of pad 5' BFG 1 6 118.7 27.5 30.2 91.2 95 479 230' N & 80' W of SE corner of pad 4' BFG 1 6 119.4 27.9 30.5 91.5 95 480 230' N & 80' W of SE corner of pad 3' BFG 1 6 118.8 27.5 30.1 91.3 95 481 230' N & 80' W of SE corner of pad 2' BFG 1 6 118.7 27.6 30.3 91.1 95 482 230' N & 80' W of SE corner of pad 1' BFG 1 6 119.3 27.7 30.2 91.6 95 483 230' N & 150' W of SE corner of pad 6' BFG 1 6 119.3 27.7 30.2 91.6 95 484 230' N & 150' W of SE corner of pad 5' BFG 1 6 119.2 27.9 30.6 91.3 95 485 230' N & 150' W of SE corner of pad 4' BFG 1 6 118.8 27.7 30.4 91.1 95 486 230' N & 150' W of SE corner of pad 3' BFG 1 6 119.4 27.9 30.5 91.5 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 3 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0017 05/30/14 06/06/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 487 230' N & 150' W of SE corner of pad 2' BFG 1 6 118.8 27.6 30.3 91.2 95 488 230' N & 150' W of SE corner of pad 1' BFG 1 6 118.7 27.7 30.4 91.0 95 Bldg. Pad D 489 200' N & 20' W of SE corner of pad 4' BFG 1 6 118.8 27.1 29.6 91.7 95 490 200' N & 20' W of SE corner of pad 3' BFG 1 6 118.7 27.3 29.9 91.4 95 491 200' N & 100' W of SE corner of pad 4' BFG 1 6 118.5 27.2 29.8 91.3 95 492 200' N & 100' W of SE corner of pad 3' BFG 1 6 118.5 27.0 29.5 91.5 95 493 200' N & 180' W of SE corner of pad 4' BFG 1 6 119.0 27.4 29.9 91.6 95 494 200' N & 180' W of SE corner of pad 3' BFG 1 6 118.4 27.2 29.8 91.2 95 495 200' N & 20' W of SE corner of pad 2' BFG 1 6 117.8 27.1 29.9 90.7 94 496 200' N & 20' W of SE corner of pad 1' BFG 1 6 117.9 27.0 29.7 90.9 94 497 200' N & 100' W of SE corner of pad 2' BFG 1 6 117.8 27.2 30.0 90.6 94 498 200' N & 100' W of SE corner of pad 1' BFG 1 6 118.6 27.5 30.2 91.1 95 499 200' N & 180' W of SE corner of pad 2' BFG 1 6 117.9 27.1 29.8 90.8 94 500 200' N & 180' W of SE corner of pad 1' BFG 1 6 117.9 27.3 30.1 90.6 94 Bldg. Pad C 501 260' N & 20' W of SE corner of pad 10' BFG 1 6 117.5 26.8 29.6 90.7 94 502 260' N & 20' W of SE corner of pad 9' BFG 1 6 118.1 27.2 29.9 90.9 94 503 260' N & 20' W of SE corner of pad 8' BFG 1 6 118.9 27.7 30.4 91.2 95 504 260' N & 20' W of SE corner of pad 7' BFG 1 6 118.1 27.3 30.1 90.8 94 505 260' N & 20' W of SE corner of pad 6' BFG 1 6 118.2 27.2 29.9 91.0 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 3 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0017 05/30/14 06/06/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 506 260' N & 80' W of SE corner of pad 10' BFG 1 6 118.8 27.7 30.4 91.1 95 507 260' N & 80' W of SE corner of pad 9' BFG 1 6 118.9 27.9 30.7 91.0 95 508 260' N & 80' W of SE corner of pad 8' BFG 1 6 118.6 27.5 30.2 91.1 95 509 260' N & 80' W of SE corner of pad 7' BFG 1 6 119.1 27.8 30.5 91.3 95 510 260' N & 80' W of SE corner of pad 6' BFG 1 6 118.8 27.8 30.6 91.0 95 511 260' N & 150' W of SE corner of pad 10' BFG 1 6 119.0 27.6 30.2 91.4 95 512 260' N & 150' W of SE corner of pad 9' BFG 1 6 119.0 27.3 29.8 91.7 95 513 260' N & 150' W of SE corner of pad 8' BFG 1 6 118.6 27.1 29.6 91.5 95 514 260' N & 150' W of SE corner of pad 7' BFG 1 6 118.6 27.3 29.9 91.3 95 515 260' N & 150' W of SE corner of pad 6' BFG 1 6 118.6 27.5 30.2 91.1 95 Comments: Datum:BFG = Below Final Grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 3 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0018 05/31/14 06/06/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92 - 98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad D 516 230' N & 20' W of SE corner of pad 10' BFG 1 6 119.0 28.0 30.8 91.0 95 517 230' N & 20' W of SE corner of pad 9' BFG 1 6 119.4 28.0 30.6 91.4 95 518 230' N & 20' W of SE corner of pad 8' BFG 1 6 118.7 27.5 30.2 91.2 95 519 230' N & 20' W of SE corner of pad 7' BFG 1 6 119.7 28.1 30.7 91.6 95 520 230' N & 20' W of SE corner of pad 6' BFG 1 6 119.1 27.8 30.5 91.3 95 521 230' N & 100' W of SE corner of pad 10' BFG 1 6 119.9 28.2 30.7 91.7 95 522 230' N & 100' W of SE corner of pad 9' BFG 1 6 119.3 27.9 30.5 91.4 95 523 230' N & 100' W of SE corner of pad 8' BFG 1 6 119.7 27.9 30.4 91.8 95 524 230' N & 100' W of SE corner of pad 7' BFG 1 6 119.5 28.0 30.6 91.5 95 525 230' N & 100' W of SE corner of pad 6' BFG 1 6 119.4 28.1 30.8 91.3 95 526 230' N & 180' W of SE corner of pad 10' BFG 1 6 119.2 28.3 31.1 90.9 94 527 230' N & 180' W of SE corner of pad 9' BFG 1 6 119.2 28.0 30.7 91.2 95 528 230' N & 180' W of SE corner of pad 8' BFG 1 6 118.9 27.8 30.5 91.1 95 529 230' N & 180' W of SE corner of pad 7' BFG 1 6 119.2 27.7 30.3 91.5 95 530 230' N & 180' W of SE corner of pad 6' BFG 1 6 119.2 27.9 30.6 91.3 95 Bldg. Pad C The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 3 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0018 05/31/14 06/06/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 531 260' N & 20' W of SE corner of pad 5' BFG 1 6 119.1 27.3 29.7 91.8 95 532 260' N & 20' W of SE corner of pad 4' BFG 1 6 118.6 27.3 29.9 91.3 95 533 260' N & 20' W of SE corner of pad 3' BFG 1 6 119.0 27.5 30.1 91.5 95 534 260' N & 20' W of SE corner of pad 2' BFG 1 6 118.1 27.0 29.6 91.1 95 535 260' N & 20' W of SE corner of pad 1' BFG 1 6 118.6 27.2 29.8 91.4 95 536 260' N & 80' W of SE corner of pad 5' BFG 1 6 118.3 27.2 29.9 91.1 95 537 260' N & 80' W of SE corner of pad 4' BFG 1 6 118.4 27.1 29.7 91.3 95 538 260' N & 80' W of SE corner of pad 3' BFG 1 6 118.6 27.1 29.6 91.5 95 539 260' N & 80' W of SE corner of pad 2' BFG 1 6 118.7 27.5 30.1 91.2 95 540 260' N & 80' W of SE corner of pad 1' BFG 1 6 118.3 27.1 29.7 91.2 95 Bldg. Pad D 541 260' N & 20' W of SE corner of pad 10' BFG 1 6 118.4 27.9 30.8 90.5 94 542 260' N & 20' W of SE corner of pad 9' BFG 1 6 118.4 27.6 30.4 90.8 94 543 260' N & 20' W of SE corner of pad 8' BFG 1 6 118.3 27.7 30.6 90.6 94 544 260' N & 20' W of SE corner of pad 7' BFG 1 6 118.4 27.5 30.3 90.9 94 545 260' N & 20' W of SE corner of pad 6' BFG 1 6 118.4 27.7 30.5 90.7 94 546 260' N & 100' W of SE corner of pad 10' BFG 1 6 118.2 27.8 30.7 90.4 94 547 260' N & 100' W of SE corner of pad 9' BFG 1 6 117.6 27.5 30.5 90.1 94 548 260' N & 100' W of SE corner of pad 8' BFG 1 6 118.1 27.5 30.4 90.6 94 549 260' N & 100' W of SE corner of pad 7' BFG 1 6 118.1 27.8 30.8 90.3 94 550 260' N & 100' W of SE corner of pad 6' BFG 1 6 118.2 27.7 30.6 90.5 94 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 3 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0018 05/31/14 06/06/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 551 260' N & 180' W of SE corner of pad 10' BFG 1 6 118.4 27.6 30.4 90.8 94 552 260' N & 180' W of SE corner of pad 9' BFG 1 6 118.9 27.9 30.7 91.0 95 553 260' N & 180' W of SE corner of pad 8' BFG 1 6 118.2 27.5 30.3 90.7 94 554 260' N & 180' W of SE corner of pad 7' BFG 1 6 118.6 27.7 30.5 90.9 94 555 260' N & 180' W of SE corner of pad 6' BFG 1 6 118.0 27.4 30.2 90.6 94 Comments: Datum:Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 3 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0019 06/02/14 06/09/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad D 556 260' N & 20' W of SE corner of pad 5' BFG 1 6 119.2 27.6 30.1 91.6 95 557 260' N & 20' W of SE corner of pad 4' BFG 1 6 119.2 27.8 30.4 91.4 95 558 260' N & 20' W of SE corner of pad 3' BFG 1 6 118.9 27.6 30.2 91.3 95 559 260' N & 20' W of SE corner of pad 2' BFG 1 6 119.4 27.9 30.5 91.5 95 560 260' N & 20' W of SE corner of pad 1' BFG 1 6 119.1 28.0 30.7 91.1 95 561 260' N & 100' W of SE corner of pad 5' BFG 1 6 119.3 27.5 30.0 91.8 95 562 260' N & 100' W of SE corner of pad 4' BFG 1 6 119.4 27.9 30.5 91.5 95 563 260' N & 100' W of SE corner of pad 3' BFG 1 6 119.4 28.0 30.6 91.4 95 564 260' N & 100' W of SE corner of pad 2' BFG 1 6 119.6 27.9 30.4 91.7 95 565 260' N & 100' W of SE corner of pad 1' BFG 1 6 118.9 27.6 30.2 91.3 95 566 260' N & 180' W of SE corner pad 5' BFG 1 6 119.3 27.4 29.8 91.9 96 567 260' N & 180' W of SE corner pad 4' BFG 1 6 119.1 27.5 30.0 91.6 95 568 260' N & 180' W of SE corner pad 3' BFG 1 6 119.1 27.3 29.7 91.8 95 569 260' N & 180' W of SE corner pad 2' BFG 1 6 118.7 27.5 30.1 91.2 95 570 260' N & 180' W of SE corner pad 1' BFG 1 6 119.1 27.6 30.2 91.5 95 Bldg. Pad C The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 3 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0019 06/02/14 06/09/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 571 290' N & 20' W of SE corner of pad 10' BFG 1 6 118.8 27.1 29.6 91.7 95 572 290' N & 20' W of SE corner of pad 9' BFG 1 6 119.4 27.5 29.9 91.9 96 573 290' N & 20' W of SE corner of pad 8' BFG 1 6 118.9 27.6 30.2 91.3 95 574 290' N & 80' W of SE corner of pad 10' BFG 1 6 118.9 27.4 29.9 91.5 95 575 290' N & 80' W of SE corner of pad 9' BFG 1 6 118.9 27.7 30.4 91.2 95 576 290' N & 80' W of SE corner of pad 8' BFG 1 6 118.5 27.4 30.1 91.1 95 577 290' N & 150' W of SE corner of pad 10' BFG 1 6 119.0 27.6 30.2 91.4 95 578 290' N & 150' W of SE corner of pad 9' BFG 1 6 119.6 28.0 30.6 91.6 95 579 290' N & 150' W of SE corner of pad 8' BFG 1 6 119.0 27.5 30.0 91.5 95 580 290' N & 20' W of SE corner of pad 7' BFG 1 6 118.7 27.8 30.6 90.9 94 581 290' N & 20' W of SE corner of pad 6' BFG 1 6 119.6 28.2 30.8 91.4 95 582 290' N & 20' W of SE corner of pad 5' BFG 1 6 118.9 27.8 30.5 91.1 95 583 290' N & 20' W of SE corner of pad 4' BFG 1 6 119.5 28.2 30.9 91.3 95 584 290' N & 20' W of SE corner of pad 3' BFG 1 6 118.8 27.8 30.6 91.0 95 585 290' N & 20' W of SE corner of pad 2' BFG 1 6 119.3 27.8 30.4 91.5 95 586 290' N & 20' W of SE corner of pad 1' BFG 1 6 119.0 27.8 30.5 91.2 95 587 290' N & 80' W of SE corner of pad 7' BFG 1 6 118.6 27.5 30.2 91.1 95 588 290' N & 80' W of SE corner of pad 6' BFG 1 6 118.5 27.7 30.5 90.8 94 589 290' N & 80' W of SE corner of pad 5' BFG 1 6 118.9 27.5 30.1 91.4 95 590 290' N & 80' W of SE corner of pad 4' BFG 1 6 119.1 27.9 30.6 91.2 95 591 290' N & 80' W of SE corner of pad 3' BFG 1 6 119.2 27.7 30.3 91.5 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 3 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0019 06/02/14 06/09/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 592 290' N & 80' W of SE corner of pad 2' BFG 1 6 119.1 27.6 30.2 91.5 95 593 290' N & 80' W of SE corner of pad 1' BFG 1 6 119.2 28.0 30.7 91.2 95 594 290' N & 150' W of SE corner of pad 7' BFG 1 6 118.8 27.8 30.5 91.0 95 595 290' N & 150' W of SE corner of pad 6' BFG 1 6 119.4 28.1 30.8 91.3 95 596 290' N & 150' W of SE corner of pad 5' BFG 1 6 119.8 28.1 30.6 91.7 95 597 290' N & 150' W of SE corner of pad 4' BFG 1 6 119.3 27.8 30.4 91.5 95 598 290' N & 150' W of SE corner of pad 3' BFG 1 6 118.4 27.3 30.0 91.1 95 599 290' N & 150' W of SE corner of pad 2' BFG 1 6 119.0 27.6 30.2 91.4 95 600 290' N & 150' W of SE corner of pad 1' BFG 1 6 119.1 27.9 30.6 91.2 95 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 3 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0020 06/03/14 06/09/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad C 601 320' N & 20' W of SE corner of pad 10' BFG 1 6 117.8 27.1 29.9 90.7 94 602 320' N & 20' W of SE corner of pad 9' BFG 1 6 117.9 27.0 29.7 90.9 94 603 320' N & 20' W of SE corner of pad 8' BFG 1 6 118.0 27.5 30.4 90.5 94 604 320' N & 20' W of SE corner of pad 7' BFG 1 6 117.4 27.2 30.2 90.2 94 605 320' N & 20' W of SE corner of pad 6' BFG 1 6 117.8 27.2 30.0 90.6 94 606 320' N & 80' W of SE corner of pad 10' BFG 1 6 118.3 27.4 30.1 90.9 94 607 320' N & 80' W of SE corner of pad 9' BFG 1 6 118.1 27.6 30.5 90.5 94 608 320' N & 80' W of SE corner of pad 8' BFG 1 6 117.5 27.3 30.3 90.2 94 609 320' N & 80' W of SE corner of pad 7' BFG 1 6 118.5 27.8 30.6 90.7 94 610 320' N & 80' W of SE corner of pad 6' BFG 1 6 117.7 27.3 30.2 90.4 94 611 320' N & 150' W of SE corner of pad 10' BFG 1 6 117.1 27.0 30.0 90.1 94 612 320' N & 150' W of SE corner of pad 9' BFG 1 6 117.8 27.4 30.3 90.4 94 613 320' N & 150' W of SE corner of pad 8' BFG 1 6 118.5 27.5 30.2 91.0 95 614 320' N & 150' W of SE corner of pad 7' BFG 1 6 118.0 27.2 30.0 90.8 94 615 320' N & 150' W of SE corner of pad 6' BFG 1 6 118.2 27.6 30.5 90.6 94 Bldg. Pad D The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0020 06/03/14 06/09/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 616 290' N & 20' W of SE corner of pad 10' BFG 1 6 119.1 27.9 30.6 91.2 95 617 290' N & 20' W of SE corner of pad 9' BFG 1 6 118.7 28.0 30.9 90.7 94 618 290' N & 20' W of SE corner of pad 8' BFG 1 6 118.6 27.7 30.5 90.9 94 619 290' N & 20' W of SE corner of pad 7' BFG 1 6 118.5 27.9 30.8 90.6 94 620 290' N & 20' W of SE corner of pad 6' BFG 1 6 118.0 27.5 30.4 90.5 94 621 290' N & 100' W of SE corner of pad 10' BFG 1 6 118.5 28.1 31.1 90.4 94 622 290' N & 100' W of SE corner of pad 9' BFG 1 6 118.5 27.8 30.7 90.7 94 623 290' N & 100' W of SE corner of pad 8' BFG 1 6 118.6 28.0 30.9 90.6 94 624 290' N & 100' W of SE corner of pad 7' BFG 1 6 118.5 27.7 30.5 90.8 94 625 290' N & 100' W of SE corner of pad 6' BFG 1 6 118.6 27.9 30.8 90.7 94 626 290' N & 180' W of SE corner of pad 10' BFG 1 6 118.7 28.2 31.2 90.5 94 627 290' N & 180' W of SE corner of pad 9' BFG 1 6 119.1 28.2 31.0 90.9 94 628 290' N & 180' W of SE corner of pad 8' BFG 1 6 118.6 27.9 30.8 90.7 94 629 290' N & 180' W of SE corner of pad 7' BFG 1 6 118.8 28.2 31.1 90.6 94 630 290' N & 180' W of SE corner of pad 6' BFG 1 6 118.9 28.1 30.9 90.8 94 Bldg. Pad C 631 320' N & 20' W of SE corner of pad 5' BFG 1 6 118.9 27.9 30.7 91.0 95 632 320' N & 20' W of SE corner of pad 4' BFG 1 6 118.9 28.2 31.1 90.7 94 633 320' N & 20' W of SE corner of pad 3' BFG 1 6 118.5 28.0 30.9 90.5 94 634 320' N & 20' W of SE corner of pad 2' BFG 1 6 118.7 27.8 30.6 90.9 94 635 320' N & 20' W of SE corner of pad 1' BFG 1 6 118.4 27.9 30.8 90.5 94 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0020 06/03/14 06/09/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 636 320' N & 80' W of SE corner of pad 5' BFG 1 6 119.1 27.9 30.6 91.2 95 637 320' N & 80' W of SE corner of pad 4' BFG 1 6 119.1 28.1 30.9 91.0 95 638 320' N & 80' W of SE corner of pad 3' BFG 1 6 118.7 27.9 30.7 90.8 94 639 320' N & 80' W of SE corner of pad 2' BFG 1 6 119.2 28.1 30.9 91.1 95 640 320' N & 80' W of SE corner of pad 1' BFG 1 6 118.7 27.8 30.6 90.9 94 641 320' N & 150' W of SE corner of pad 5' BFG 1 6 118.6 27.9 30.8 90.7 94 642 320' N & 150' W of SE corner of pad 4' BFG 1 6 118.9 27.8 30.5 91.1 95 643 320' N & 150' W of SE corner of pad 3' BFG 1 6 118.9 28.1 30.9 90.8 94 644 320' N & 150' W of SE corner of pad 2' BFG 1 6 118.9 27.9 30.7 91.0 95 645 320' N & 150' W of SE corner of pad 1' BFG 1 6 118.5 27.6 30.4 90.9 94 Bldg. Pad D 646 320' N & 20' W of SE corner of pad 10' BFG 1 6 119.3 28.0 30.7 91.3 95 647 320' N & 20' W of SE corner of pad 9' BFG 1 6 119.5 27.9 30.5 91.6 95 648 320' N & 20' W of SE corner of pad 8' BFG 1 6 119.8 28.4 31.1 91.4 95 649 320' N & 20' W of SE corner of pad 7' BFG 1 6 119.9 28.2 30.7 91.7 95 650 320' N & 20' W of SE corner of pad 6' BFG 1 6 119.5 28.2 30.9 91.3 95 651 320' N & 100' W of SE corner of pad 10' BFG 1 6 118.6 27.2 29.8 91.4 95 652 320' N & 100' W of SE corner of pad 9' BFG 1 6 118.4 27.4 30.1 91.0 95 653 320' N & 100' W of SE corner of pad 8' BFG 1 6 118.4 27.1 29.7 91.3 95 654 320' N & 100' W of SE corner of pad 7' BFG 1 6 119.0 27.5 30.0 91.5 95 655 320' N & 100' W of SE corner of pad 6' BFG 1 6 118.7 27.5 30.2 91.2 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0020 06/03/14 06/09/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 656 320' N & 180' W of SE corner of pad 10' BFG 1 6 118.6 27.1 29.6 91.5 95 657 320' N & 180' W of SE corner of pad 9' BFG 1 6 119.1 27.4 29.9 91.7 95 658 320' N & 180' W of SE corner of pad 8' BFG 1 6 118.5 27.1 29.7 91.4 95 659 320' N & 180' W of SE corner of pad 7' BFG 1 6 118.7 27.5 30.2 91.2 95 660 320' N & 180' W of SE corner of pad 6' BFG 1 6 118.8 27.4 30.0 91.4 95 Bldg. Pad C 661 350' N & 20' W of SE corner of pad 10' BFG 1 6 119.4 28.5 31.4 90.9 94 662 350' N & 20' W of SE corner of pad 9' BFG 1 6 119.4 28.8 31.8 90.6 94 663 350' N & 20' W of SE corner of pad 8' BFG 1 6 119.4 28.6 31.5 90.8 94 664 350' N & 20' W of SE corner of pad 7' BFG 1 6 120.0 28.9 31.7 91.1 95 665 350' N & 20' W of SE corner of pad 6' BFG 1 6 119.1 28.4 31.3 90.7 94 666 350' N & 80' W of SE corner of pad 10' BFG 1 6 118.2 28.0 31.0 90.2 94 667 350' N & 80' W of SE corner of pad 9' BFG 1 6 118.4 28.4 31.5 90.0 94 668 350' N & 80' W of SE corner of pad 8' BFG 1 6 119.1 28.7 31.7 90.4 94 669 350' N & 80' W of SE corner of pad 7' BFG 1 6 119.2 28.5 31.4 90.7 94 670 350' N & 80' W of SE corner of pad 6' BFG 1 6 119.0 28.7 31.8 90.3 94 671 350' N & 150' W of SE corner of pad 10' BFG 1 6 118.6 28.1 31.1 90.5 94 672 350' N & 150' W of SE corner of pad 9' BFG 1 6 119.4 28.5 31.4 90.9 94 673 350' N & 150' W of SE corner of pad 8' BFG 1 6 117.5 26.9 29.7 90.6 94 674 350' N & 150' W of SE corner of pad 7' BFG 1 6 118.5 27.3 29.9 91.2 95 675 350' N & 150' W of SE corner of pad 6' BFG 1 6 118.5 27.5 30.2 91.0 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 4 of 6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0020 06/03/14 06/09/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad D 676 320' N & 20' W of SE corner of pad 5' BFG 1 6 119.2 27.4 29.8 91.8 95 677 320' N & 20' W of SE corner of pad 4' BFG 1 6 119.3 27.7 30.2 91.6 95 678 320' N & 20' W of SE corner of pad 3' BFG 1 6 119.2 27.5 30.0 91.7 95 679 320' N & 20' W of SE corner of pad 2' BFG 1 6 119.3 27.8 30.4 91.5 95 680 320' N & 20' W of SE corner of pad 1' BFG 1 6 118.8 27.6 30.3 91.2 95 681 320' N & 100' W of SE corner of pad 5' BFG 1 6 118.6 27.9 30.8 90.7 94 682 320' N & 100' W of SE corner of pad 4' BFG 1 6 119.2 27.8 30.4 91.4 95 683 320' N & 100' W of SE corner of pad 3' BFG 1 6 118.6 27.6 30.3 91.0 95 684 320' N & 100' W of SE corner of pad 2' BFG 1 6 119.1 27.8 30.5 91.3 95 685 320' N & 100' W of SE corner of pad 1' BFG 1 6 119.3 27.7 30.2 91.6 95 686 320' N & 180' W of SE corner of pad 5' BFG 1 6 119.0 28.0 30.8 91.0 95 687 320' N & 180' W of SE corner of pad 4' BFG 1 6 118.6 27.8 30.6 90.8 94 688 320' N & 180' W of SE corner of pad 3' BFG 1 6 119.2 28.0 30.7 91.2 95 689 320' N & 180' W of SE corner of pad 2' BFG 1 6 119.6 28.2 30.9 91.4 95 690 320' N & 180' W of SE corner of pad 1' BFG 1 6 118.9 27.8 30.5 91.1 95 Comments: Datum:Serial No: Test and/or retest results on this report meet project requirements as noted above. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 5 of 6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0020 06/03/14 06/09/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 6 of 6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0021 06/04/14 06/11/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad C 691 350' N & 20' W of SE corner of pad 5' BFG 1 6 118.5 27.1 29.7 91.4 95 692 350' N & 20' W of SE corner of pad 4' BFG 1 6 118.5 27.3 29.9 91.2 95 693 350' N & 20' W of SE corner of pad 3' BFG 1 6 119.4 27.7 30.2 91.7 95 694 350' N & 20' W of SE corner of pad 2' BFG 1 6 119.0 27.5 30.0 91.5 95 695 350' N & 20' W of SE corner of pad 1' BFG 1 6 118.9 27.6 30.2 91.3 95 696 350' N & 80' W of SE corner of pad 5' BFG 1 6 118.7 27.5 30.1 91.2 95 697 350' N & 80' W of SE corner of pad 4' BFG 1 6 118.9 27.3 29.8 91.6 95 698 350' N & 80' W of SE corner of pad 3' BFG 1 6 119.2 27.8 30.4 91.4 95 699 350' N & 80' W of SE corner of pad 2' BFG 1 6 119.3 27.5 30.0 91.8 95 700 350' N & 80' W of SE corner of pad 1' BFG 1 6 119.3 27.7 30.2 91.6 95 701 350' N & 150' W of SE corner of pad 5' BFG 1 6 118.9 27.8 30.5 91.1 95 702 350' N & 150' W of SE corner of pad 4' BFG 1 6 119.2 27.7 30.3 91.5 95 703 350' N & 150' W of SE corner of pad 3' BFG 1 6 118.8 27.6 30.3 91.2 95 704 350' N & 150' W of SE corner of pad 2' BFG 1 6 118.4 27.4 30.1 91.0 95 705 350' N & 150' W of SE corner of pad 1' BFG 1 6 118.5 27.7 30.5 90.8 94 706 380' N & 20' W of SE corner of pad 10' BFG 1 6 118.8 27.2 29.7 91.6 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0021 06/04/14 06/11/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 707 380' N & 20' W of SE corner of pad 9' BFG 1 6 118.5 27.3 29.9 91.2 95 708 380' N & 20' W of SE corner of pad 8' BFG 1 6 119.3 27.8 30.4 91.5 95 709 380' N & 20' W of SE corner of pad 7' BFG 1 6 118.8 27.5 30.1 91.3 95 710 380' N & 20' W of SE corner of pad 6' BFG 1 6 118.6 27.6 30.3 91.0 95 711 380' N & 80' W of SE corner of pad 10' BFG 1 6 119.4 27.7 30.2 91.7 95 712 380' N & 80' W of SE corner of pad 9' BFG 1 6 119.4 28.0 30.6 91.4 95 713 380' N & 80' W of SE corner of pad 8' BFG 1 6 119.3 27.8 30.4 91.5 95 714 380' N & 80' W of SE corner of pad 7' BFG 1 6 119.0 27.7 30.3 91.3 95 715 380' N & 80' W of SE corner of pad 6' BFG 1 6 118.4 27.6 30.4 90.8 94 716 380' N & 150' W of SE corner of pad 10' BFG 1 6 118.5 27.8 30.6 90.7 94 717 380' N & 150' W of SE corner of pad 9' BFG 1 6 117.8 27.4 30.3 90.4 94 718 380' N & 150' W of SE corner of pad 8' BFG 1 6 117.7 27.5 30.5 90.2 94 719 380' N & 150' W of SE corner of pad 7' BFG 1 6 117.7 27.7 30.8 90.0 94 720 380' N & 150' W of SE corner of pad 6' BFG 1 6 117.5 27.4 30.4 90.1 94 721 380' N & 20' W of SE corner of pad 5' BFG 1 6 119.9 28.7 31.5 91.2 95 722 380' N & 20' W of SE corner of pad 4' BFG 1 6 119.2 28.2 31.0 91.0 95 723 380' N & 20' W of SE corner of pad 3' BFG 1 6 120.0 28.5 31.2 91.5 95 724 380' N & 20' W of SE corner of pad 2' BFG 1 6 119.7 28.6 31.4 91.1 95 725 380' N & 20' W of SE corner of pad 1' BFG 1 6 120.1 28.5 31.1 91.6 95 726 380' N & 80' W of SE corner of pad 5' BFG 1 6 119.6 28.2 30.9 91.4 95 727 380' N & 80' W of SE corner of pad 4' BFG 1 6 119.6 28.6 31.4 91.0 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0021 06/04/14 06/11/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 728 380' N & 80' W of SE corner of pad 3' BFG 1 6 119.6 28.3 31.0 91.3 95 729 380' N & 80' W of SE corner of pad 2' BFG 1 6 119.5 28.4 31.2 91.1 95 730 380' N & 80' W of SE corner of pad 1' BFG 1 6 120.4 28.9 31.6 91.5 95 731 380' N & 150' W of SE corner of pad 5' BFG 1 6 119.9 28.5 31.2 91.4 95 732 380' N & 150' W of SE corner of pad 4' BFG 1 6 119.7 28.7 31.5 91.0 95 733 380' N & 150' W of SE corner of pad 3' BFG 1 6 120.1 28.6 31.3 91.5 95 734 380' N & 150' W of SE corner of pad 2' BFG 1 6 119.5 28.3 31.0 91.2 95 735 380' N & 150' W of SE corner of pad 1' BFG 1 6 119.0 27.3 29.8 91.7 95 736 410' N & 20' W of SE corner of pad 10' BFG 1 6 119.8 28.6 31.4 91.2 95 737 410' N & 20' W of SE corner of pad 9' BFG 1 6 119.3 28.3 31.1 91.0 95 738 410' N & 20' W of SE corner of pad 8' BFG 1 6 120.4 28.9 31.6 91.5 95 739 410' N & 80' W of SE corner of pad 10' BFG 1 6 119.9 28.6 31.3 91.3 95 740 410' N & 80' W of SE corner of pad 9' BFG 1 6 119.3 28.2 31.0 91.1 95 741 410' N & 80' W of SE corner of pad 8' BFG 1 6 120.2 28.8 31.5 91.4 95 742 410' N & 150' W of SE corner of pad 10' BFG 1 6 120.3 28.6 31.2 91.7 95 743 410' N & 150' W of SE corner of pad 9' BFG 1 6 119.6 28.4 31.1 91.2 95 744 410' N & 150' W of SE corner of pad 8' BFG 1 6 120.1 28.6 31.3 91.5 95 745 360' N & 20' W of SE corner of pad 10' BFG 1 6 119.0 27.9 30.6 91.1 95 746 360' N & 20' W of SE corner of pad 9' BFG 1 6 118.9 28.1 30.9 90.8 94 747 360' N & 20' W of SE corner of pad 8' BFG 1 6 119.5 28.1 30.7 91.4 95 748 360' N & 20' W of SE corner of pad 7' BFG 1 6 119.0 27.8 30.5 91.2 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0021 06/04/14 06/11/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 749 360' N & 100' W of SE corner of pad 10' BFG 1 6 119.9 28.2 30.8 91.7 95 750 360' N & 100' W of SE corner of pad 9' BFG 1 6 119.0 27.8 30.5 91.2 95 751 360' N & 100' W of SE corner of pad 8' BFG 1 6 119.2 27.7 30.3 91.5 95 752 360' N & 100' W of SE corner of pad 7' BFG 1 6 119.0 27.9 30.6 91.1 95 753 360' N & 180' W of SE corner of pad 10' BFG 1 6 119.9 28.2 30.8 91.7 95 754 360' N & 180' W of SE corner of pad 9' BFG 1 6 119.1 27.9 30.6 91.2 95 755 360' N & 180' W of SE corner of pad 8' BFG 1 6 119.1 27.7 30.3 91.4 95 756 360' N & 180' W of SE corner of pad 7' BFG 1 6 119.8 28.0 30.5 91.8 95 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 4 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0022 06/05/14 06/12/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Building Pad C 817 410' N & 20' W of the SE corner of pad 7' BFG 1 6 119.1 27.9 30.6 91.2 95 818 410' N & 20' W of the SE corner of pad 6' BFG 1 6 118.6 27.6 30.3 91.0 95 819 410' N & 20' W of the SE corner of pad 5' BFG 1 6 119.4 27.8 30.4 91.6 95 820 410' N & 20' W of the SE corner of pad 4' BFG 1 6 119.0 27.6 30.2 91.4 95 821 410' N & 20' W of the SE corner of pad 5' BFG 1 6 118.8 27.5 30.1 91.3 95 822 410' N & 20' W of the SE corner of pad 2' BFG 1 6 119.4 27.9 30.5 91.5 95 823 410' N & 20' W of the SE corner of pad 1' BFG 1 6 119.1 27.5 30.0 91.6 95 824 410' N & 80' W of the SE corner of pad 7' BFG 1 6 119.1 27.4 29.9 91.7 95 825 410' N & 80' W of the SE corner of pad 6' BFG 1 6 119.0 27.6 30.2 91.4 95 826 410' N & 80' W of the SE corner of pad 5' BFG 1 6 118.6 27.4 30.0 91.2 95 827 410' N & 80' W of the SE corner of pad 4' BFG 1 6 118.9 27.3 29.8 91.6 95 828 410' N & 80' W of the SE corner of pad 3' BFG 1 6 119.0 27.7 30.3 91.3 95 829 410' N & 80' W of the SE corner of pad 2' BFG 1 6 119.5 28.1 30.7 91.4 95 830 410' N & 80' W of the SE corner of pad 1' BFG 1 6 118.8 27.8 30.5 91.0 95 831 410' N & 150' W of the SE corner of pad 7' BFG 1 6 119.4 27.8 30.4 91.6 95 832 410' N & 150' W of the SE corner of pad 6' BFG 1 6 119.5 28.1 30.7 91.4 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0022 06/05/14 06/12/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 833 410' N & 150' W of the SE corner of pad 5' BFG 1 6 118.8 27.6 30.3 91.2 95 834 410' N & 150' W of the SE corner of pad 4' BFG 1 6 119.4 27.9 30.5 91.5 95 835 410' N & 150' W of the SE corner of pad 3' BFG 1 6 118.9 27.6 30.2 91.3 95 836 410' N & 150' W of the SE corner of pad 2' BFG 1 6 119.6 28.0 30.6 91.6 95 837 410' N & 150' W of the SE corner of pad 1' BFG 1 6 118.8 27.6 30.3 91.2 95 838 440' N & 20' W of the SE corner of pad 10' BFG 1 6 118.8 27.3 29.8 91.5 95 839 440' N & 20' W of the SE corner of pad 9' BFG 1 6 119.0 27.2 29.6 91.8 95 840 440' N & 20' W of the SE corner of pad 8' BFG 1 6 118.4 27.3 30.0 91.1 95 841 440' N & 20' W of the SE corner of pad 7' BFG 1 6 119.4 27.8 30.4 91.6 95 842 440' N & 20' W of the SE corner of pad 6' BFG 1 6 119.3 27.5 30.0 91.8 95 843 440' N & 80' W of the SE corner of pad 10' BFG 1 6 118.9 27.4 29.9 91.5 95 844 440' N & 80' W of the SE corner of pad 9' BFG 1 6 118.9 27.6 30.2 91.3 95 845 440' N & 80' W of the SE corner of pad 8' BFG 1 6 119.2 27.6 30.1 91.6 95 846 440' N & 80' W of the SE corner of pad 7' BFG 1 6 119.1 27.7 30.3 91.4 95 847 440' N & 80' W of the SE corner of pad 6' BFG 1 6 119.0 27.8 30.5 91.2 95 848 440' N & 150' W of the SE corner of pad 10' BFG 1 6 119.3 27.7 30.2 91.6 95 849 440' N & 150' W of the SE corner of pad 9' BFG 1 6 119.4 28.0 30.6 91.4 95 850 440' N & 150' W of the SE corner of pad 8' BFG 1 6 118.7 27.6 30.3 91.1 95 851 440' N & 150' W of the SE corner of pad 7' BFG 1 6 119.4 27.9 30.5 91.5 95 852 440' N & 150' W of the SE corner of pad 6' BFG 1 6 118.8 27.5 30.1 91.3 95 853 440' N & 20' W of the SE corner of pad 5' BFG 1 6 118.9 27.4 29.9 91.5 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0022 06/05/14 06/12/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 854 440' N & 20' W of the SE corner of pad 4' BFG 1 6 118.7 27.5 30.2 91.2 95 855 440' N & 20' W of the SE corner of pad 3' BFG 1 6 119.6 27.9 30.4 91.7 95 856 440' N & 20' W of the SE corner of pad 2' BFG 1 6 118.9 27.5 30.1 91.4 95 857 440' N & 20' W of the SE corner of pad 1' BFG 1 6 119.4 27.8 30.3 91.6 95 858 440' N & 80' W of the SE corner of pad 5' BFG 1 6 119.6 28.2 30.8 91.4 95 859 440' N & 80' W of the SE corner of pad 4' BFG 1 6 119.8 28.1 30.6 91.7 95 860 440' N & 80' W of the SE corner of pad 3' BFG 1 6 119.4 28.2 30.9 91.2 95 861 440' N & 80' W of the SE corner of pad 2' BFG 1 6 119.6 28.1 30.7 91.5 95 862 440' N & 80' W of the SE corner of pad 1' BFG 1 6 119.1 27.8 30.5 91.3 95 863 440' N & 150' W of the SE corner of pad 5' BFG 1 6 119.0 28.0 30.8 91.0 95 864 440' N & 150' W of the SE corner of pad 4' BFG 1 6 119.4 28.0 30.6 91.4 95 865 440' N & 150' W of the SE corner of pad 3' BFG 1 6 119.8 28.1 30.6 91.7 95 866 440' N & 150' W of the SE corner of pad 2' BFG 1 6 119.6 28.2 30.9 91.4 95 867 440' N & 150' W of the SE corner of pad 1' BFG 1 6 119.8 28.0 30.5 91.8 95 Building Pad D 868 360' N & 20' W of the SE corner of pad 6' BFG 1 6 118.9 27.6 30.2 91.3 95 869 360' N & 20' W of the SE corner of pad 5' BFG 1 6 118.9 27.8 30.5 91.1 95 870 360' N & 20' W of the SE corner of pad 4' BFG 1 6 119.6 28.2 30.8 91.4 95 871 360' N & 20' W of the SE corner of pad 3' BFG 1 6 119.1 27.9 30.6 91.2 95 872 360' N & 20' W of the SE corner of pad 2' BFG 1 6 119.2 27.7 30.3 91.5 95 873 360' N & 20' W of the SE corner of pad 1' BFG 1 6 119.2 27.4 29.9 91.8 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0022 06/05/14 06/12/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 874 360' N & 100' W of the SE corner of pad 6' BFG 1 6 118.8 27.2 29.7 91.6 95 875 360' N & 100' W of the SE corner of pad 5' BFG 1 6 119.5 27.6 30.0 91.9 96 876 360' N & 100' W of the SE corner of pad 4' BFG 1 6 118.9 27.4 29.9 91.5 95 877 360' N & 100' W of the SE corner of pad 3' BFG 1 6 119.6 28.2 30.8 91.4 95 878 360' N & 100' W of the SE corner of pad 2' BFG 1 6 119.1 27.9 30.6 91.2 95 879 360' N & 100' W of the SE corner of pad 1' BFG 1 6 119.1 28.1 30.9 91.0 95 880 360' N & 180' W of the SE corner of pad 6' BFG 1 6 119.0 27.5 30.1 91.5 95 881 360' N & 180' W of the SE corner of pad 5' BFG 1 6 118.9 27.7 30.4 91.2 95 882 360' N & 180' W of the SE corner of pad 4' BFG 1 6 119.3 27.7 30.2 91.6 95 883 360' N & 180' W of the SE corner of pad 3' BFG 1 6 119.3 27.9 30.5 91.4 95 884 360' N & 180' W of the SE corner of pad 2' BFG 1 6 119.3 27.6 30.1 91.7 95 885 360' N & 180' W of the SE corner of pad 1' BFG 1 6 119.2 27.9 30.6 91.3 95 886 390' N & 20' W of the SE corner of pad 10' BFG 1 6 119.2 27.4 29.8 91.8 95 887 390' N & 20' W of the SE corner of pad 9' BFG 1 6 119.0 27.6 30.2 91.4 95 888 390' N & 20' W of the SE corner of pad 8' BFG 1 6 119.1 27.5 30.0 91.6 95 889 390' N & 20' W of the SE corner of pad 7' BFG 1 6 118.6 27.5 30.2 91.1 95 890 390' N & 20' W of the SE corner of pad 6' BFG 1 6 119.5 27.9 30.5 91.6 95 891 390' N & 100' W of the SE corner of pad 10' BFG 1 6 119.4 27.5 29.9 91.9 96 892 390' N & 100' W of the SE corner of pad 9' BFG 1 6 119.2 27.8 30.4 91.4 95 893 390' N & 100' W of the SE corner of pad 8' BFG 1 6 119.3 27.7 30.2 91.6 95 894 390' N & 100' W of the SE corner of pad 7' BFG 1 6 119.1 27.8 30.5 91.3 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 4 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0022 06/05/14 06/12/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 895 390' N & 100' W of the SE corner of pad 6' BFG 1 6 119.2 27.7 30.3 91.5 95 896 390' N & 180' W of the SE corner of pad 10' BFG 1 6 119.4 28.1 30.8 91.3 95 897 390' N & 180' W of the SE corner of pad 9' BFG 1 6 119.6 28.0 30.6 91.6 95 898 390' N & 180' W of the SE corner of pad 8' BFG 1 6 119.2 27.8 30.4 91.4 95 899 390' N & 180' W of the SE corner of pad 7' BFG 1 6 119.5 27.7 30.2 91.8 95 900 390' N & 180' W of the SE corner of pad 6' BFG 1 6 119.4 27.9 30.5 91.5 95 Comments: Datum:BFG = below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 5 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0023 06/06/14 06/12/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad C 757 470' N & 20' W of Se corner of pad 10' BFG 1 6 119.0 27.4 29.9 91.6 95 758 470' N & 20' W of Se corner of pad 9' BFG 1 6 118.7 27.7 30.4 91.0 95 759 470' N & 20' W of Se corner of pad 8' BFG 1 6 118.9 27.6 30.2 91.3 95 760 470' N & 20' W of Se corner of pad 7' BFG 1 6 118.8 27.3 29.8 91.5 95 761 470' N & 20' W of Se corner of pad 6' BFG 1 6 118.7 27.5 30.1 91.2 95 762 470' N & 80' W of SE corner of pad 10' BFG 1 6 118.9 27.6 30.2 91.3 95 763 470' N & 80' W of SE corner of pad 9' BFG 1 6 119.3 27.9 30.5 91.4 95 764 470' N & 80' W of SE corner of pad 8' BFG 1 6 118.8 27.6 30.3 91.2 95 765 470' N & 80' W of SE corner of pad 7' BFG 1 6 118.5 27.4 30.1 91.1 95 766 470' N & 80' W of SE corner of pad 6' BFG 1 6 119.5 28.1 30.7 91.4 95 767 470' N & 150' W of SE corner of pad 10' BFG 1 6 119.6 27.9 30.4 91.7 95 768 470' N & 150' W of SE corner of pad 9' BFG 1 6 119.1 27.6 30.2 91.5 95 769 470' N & 150' W of SE corner of pad 8' BFG 1 6 119.1 27.9 30.6 91.2 95 770 470' N & 150' W of SE corner of pad 7' BFG 1 6 119.4 27.8 30.3 91.6 95 771 470' N & 150' W of SE corner of pad 6' BFG 1 6 119.4 27.6 30.1 91.8 95 Bldg. Pad D The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0023 06/06/14 06/12/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 772 390' N & 20' W of SE corner of pad 5' BFG 1 6 119.0 27.8 30.5 91.2 95 773 390' N & 20' W of SE corner of pad 4' BFG 1 6 119.0 27.6 30.2 91.4 95 774 390' N & 20' W of SE corner of pad 3' BFG 1 6 119.0 27.9 30.6 91.1 95 775 390' N & 20' W of SE corner of pad 2' BFG 1 6 119.2 27.7 30.3 91.5 95 776 390' N & 20' W of SE corner of pad 1' BFG 1 6 118.8 27.5 30.1 91.3 95 777 390' N & 100' W of SE corner of pad 5' BFG 1 6 119.0 28.0 30.8 91.0 95 778 390' N & 100' W of SE corner of pad 4' BFG 1 6 119.2 27.8 30.4 91.4 95 779 390' N & 100' W of SE corner of pad 3' BFG 1 6 119.1 27.9 30.6 91.2 95 780 390' N & 100' W of SE corner of pad 2' BFG 1 6 119.5 27.8 30.3 91.7 95 781 390' N & 100' W of SE corner of pad 1' BFG 1 6 118.8 27.8 30.6 91.0 95 782 390' N & 180' W of SE corner of pad 5' BFG 1 6 119.3 27.8 30.4 91.5 95 783 390' N & 180' W of SE corner of pad 4' BFG 1 6 119.3 28.1 30.8 91.2 95 784 390' N & 180' W of SE corner of pad 3' BFG 1 6 119.7 28.0 30.5 91.7 95 785 390' N & 180' W of SE corner of pad 2' BFG 1 6 119.0 27.7 30.3 91.3 95 786 390' N & 180' W of SE corner of pad 1' BFG 1 6 119.6 28.0 30.6 91.6 95 787 470' N & 20' W of Se corner of pad 5' BFG 1 6 119.5 28.0 30.6 91.5 95 788 470' N & 20' W of Se corner of pad 4' BFG 1 6 118.6 27.5 30.2 91.1 95 789 470' N & 20' W of Se corner of pad 3' BFG 1 6 119.7 28.0 30.5 91.7 95 790 470' N & 20' W of Se corner of pad 2' BFG 1 6 119.1 27.7 30.3 91.4 95 791 470' N & 20' W of Se corner of pad 1' BFG 1 6 118.7 27.5 30.1 91.2 95 792 470' N & 80' W of SE corner of pad 5' BFG 1 6 119.6 27.9 30.4 91.7 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0023 06/06/14 06/12/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 793 470' N & 80' W of SE corner of pad 4' BFG 1 6 119.0 27.6 30.2 91.4 95 794 470' N & 80' W of SE corner of pad 3' BFG 1 6 118.8 27.8 30.6 91.0 95 795 470' N & 80' W of SE corner of pad 2' BFG 1 6 118.7 27.5 30.2 91.2 95 796 470' N & 80' W of SE corner of pad 1' BFG 1 6 119.5 27.9 30.5 91.6 95 797 470' N & 150' W of SE corner of pad 5' BFG 1 6 119.4 28.1 30.8 91.3 95 798 470' N & 150' W of SE corner of pad 4' BFG 1 6 119.5 27.9 30.5 91.6 95 799 470' N & 150' W of SE corner of pad 3' BFG 1 6 119.0 27.3 29.8 91.7 95 800 470' N & 150' W of SE corner of pad 2' BFG 1 6 119.1 27.6 30.2 91.5 95 801 470' N & 150' W of SE corner of pad 1' BFG 1 6 118.7 27.4 30.0 91.3 95 802 420' N & 20' W of SE corner of pad 10' BFG 1 6 118.9 27.7 30.4 91.2 95 803 420' N & 20' W of SE corner of pad 9' BFG 1 6 118.4 27.4 30.1 91.0 95 804 420' N & 20' W of SE corner of pad 8' BFG 1 6 119.1 27.7 30.3 91.4 95 805 420' N & 20' W of SE corner of pad 7' BFG 1 6 119.6 28.0 30.6 91.6 95 806 420' N & 20' W of SE corner of pad 6' BFG 1 6 119.1 27.8 30.4 91.3 95 807 420' N & 100' W of SE corner of pad 10' BFG 1 6 119.0 28.0 30.8 91.0 95 808 420' N & 100' W of SE corner of pad 9' BFG 1 6 119.2 27.9 30.6 91.3 95 809 420' N & 100' W of SE corner of pad 8' BFG 1 6 118.4 27.5 30.3 90.9 94 810 420' N & 100' W of SE corner of pad 7' BFG 1 6 119.3 27.9 30.5 91.4 95 811 420' N & 100' W of SE corner of pad 6' BFG 1 6 119.3 27.9 30.5 91.4 95 812 420' N & 180' W of SE corner of pad 10' BFG 1 6 119.2 27.4 29.9 91.8 95 813 420' N & 180' W of SE corner of pad 9' BFG 1 6 119.2 27.7 30.3 91.5 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0023 06/06/14 06/12/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 814 420' N & 180' W of SE corner of pad 8' BFG 1 6 118.8 27.5 30.1 91.3 95 815 420' N & 180' W of SE corner of pad 7' BFG 1 6 119.4 27.8 30.4 91.6 95 816 420' N & 180' W of SE corner of pad 6' BFG 1 6 118.7 27.5 30.2 91.2 95 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 4 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0024 06/07/14 06/16/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad D 901 420' N & 20' W of SE corner of pad 5' BFG 1 6 118.7 27.8 30.6 90.9 94 902 420' N & 20' W of SE corner of pad 4' BFG 1 6 117.2 27.1 30.1 90.1 94 903 420' N & 20' W of SE corner of pad 3' BFG 1 6 118.4 27.7 30.5 90.7 94 904 420' N & 20' W of SE corner of pad 2' BFG 1 6 118.4 27.6 30.4 90.8 94 905 420' N & 20' W of SE corner of pad 1' BFG 1 6 117.8 27.3 30.2 90.5 94 906 420' N & 100' W of SE corner of pad 5' BFG 1 6 118.6 27.9 30.8 90.7 94 907 420' N & 100' W of SE corner of pad 4' BFG 1 6 117.6 27.5 30.5 90.1 94 908 420' N & 100' W of SE corner of pad 3' BFG 1 6 118.0 27.4 30.2 90.6 94 909 420' N & 100' W of SE corner of pad 2' BFG 1 6 118.0 27.7 30.7 90.3 94 910 420' N & 100' W of SE corner of pad 1' BFG 1 6 117.4 27.4 30.4 90.0 94 911 420' N & 180' W of SE corner of pad 5' BFG 1 6 118.0 27.2 30.0 90.8 94 912 420' N & 180' W of SE corner of pad 4' BFG 1 6 117.9 27.4 30.3 90.5 94 913 420' N & 180' W of SE corner of pad 3' BFG 1 6 118.8 27.7 30.4 91.1 95 914 420' N & 180' W of SE corner of pad 2' BFG 1 6 118.2 27.4 30.2 90.8 94 915 420' N & 180' W of SE corner of pad 1' BFG 1 6 117.8 27.2 30.0 90.6 94 Bldg. Pad B The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0024 06/07/14 06/16/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 916 20' N & 20' W of SE corner of pad 10' BFG 1 6 118.4 27.7 30.5 90.7 94 917 20' N & 20' W of SE corner of pad 9' BFG 1 6 117.9 27.8 30.9 90.1 94 918 20' N & 20' W of SE corner of pad 8' BFG 1 6 118.2 27.8 30.7 90.4 94 919 20' N & 20' W of SE corner of pad 7' BFG 1 6 117.6 27.4 30.4 90.2 94 920 20' N & 80' W of SE corner of pad 10' BFG 1 6 117.7 27.7 30.8 90.0 94 921 20' N & 80' W of SE corner of pad 9' BFG 1 6 117.5 27.2 30.1 90.3 94 922 20' N & 80' W of SE corner of pad 8' BFG 1 6 118.1 27.5 30.3 90.6 94 923 20' N & 80' W of SE corner of pad 7' BFG 1 6 117.8 27.6 30.6 90.2 94 924 20' N & 130' W of SE corner of pad 10' BFG 1 6 117.8 27.3 30.2 90.5 94 925 20' N & 130' W of SE corner of pad 9' BFG 1 6 118.4 27.4 30.1 91.0 95 926 20' N & 130' W of SE corner of pad 8' BFG 1 6 118.4 27.6 30.4 90.8 94 927 20' N & 130' W of SE corner of pad 7' BFG 1 6 117.8 27.3 30.2 90.5 94 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 2 FIELD DENSITY TESTING REPORT Report Number:94141126.0025 Service Date:06/09/14 8901 Carpenter Frwy., Suite 100 Report Date:06/16/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Field density testing. Terracon Rep.: Armando Rendon Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 tp On this date, Terracon's representative arrived at the above referenced job site as scheduled for field density testing. After arriving at the job site, Terracon's representative was notified that the scheduled in-place density testing was cancelled by the contractor because the area was too wet for testing. FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0026 06/10/14 06/17/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad B 928 20' N & 20' W of SE corner of pad 6' BFG 1 6 118.4 28.3 31.4 90.1 94 929 20' N & 20' W of SE corner of pad 5' BFG 1 6 118.3 28.0 31.0 90.3 94 930 20' N & 20' W of SE corner of pad 4' BFG 1 6 119.0 28.3 31.2 90.7 94 931 20' N & 20' W of SE corner of pad 3' BFG 1 6 118.6 28.4 31.5 90.2 94 932 20' N & 20' W of SE corner of pad 2' BFG 1 6 118.6 28.1 31.1 90.5 94 933 20' N & 20' W of SE corner of pad 1' BFG 1 6 119.0 28.4 31.3 90.6 94 934 20' N & 80' W of SE corner of pad 6' BFG 1 6 118.7 28.2 31.2 90.5 94 935 20' N & 80' W of SE corner of pad 5' BFG 1 6 118.3 28.0 31.0 90.3 94 936 20' N & 80' W of SE corner of pad 4' BFG 1 6 119.0 28.4 31.3 90.6 94 937 20' N & 80' W of SE corner of pad 3' BFG 1 6 118.7 28.5 31.6 90.2 94 938 20' N & 80' W of SE corner of pad 2' BFG 1 6 118.8 28.4 31.4 90.4 94 939 20' N & 80' W of SE corner of pad 1' BFG 1 6 118.2 28.1 31.2 90.1 94 940 20' N & 130' W of SE corner of pad 6' BFG 1 6 119.0 28.3 31.2 90.7 94 941 20' N & 130' W of SE corner of pad 5' BFG 1 6 119.0 28.5 31.5 90.5 94 942 20' N & 130' W of SE corner of pad 4' BFG 1 6 118.6 28.3 31.3 90.3 94 943 20' N & 130' W of SE corner of pad 3' BFG 1 6 118.9 28.1 31.0 90.8 94 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0026 06/10/14 06/17/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 944 20' N & 130' W of SE corner of pad 2' BFG 1 6 118.8 28.4 31.4 90.4 94 945 20' N & 130' W of SE corner of pad 1' BFG 1 6 118.8 28.2 31.1 90.6 94 Bldg. Pad D 946 450' N & 20' W of SE corner of pad 10' BFG 1 6 118.7 28.4 31.4 90.3 94 947 450' N & 20' W of SE corner of pad 9' BFG 1 6 118.8 28.2 31.1 90.6 94 948 450' N & 20' W of SE corner of pad 8' BFG 1 6 118.6 28.4 31.5 90.2 94 949 450' N & 20' W of SE corner of pad 7' BFG 1 6 118.7 28.3 31.3 90.4 94 950 450' N & 20' W of SE corner of pad 6' BFG 1 6 119.1 28.6 31.6 90.5 94 951 450' N & 100' W of SE corner of pad 10' BFG 1 6 119.0 28.3 31.2 90.7 94 952 450' N & 100' W of SE corner of pad 9' BFG 1 6 120.1 28.5 31.1 91.6 95 953 450' N & 100' W of SE corner of pad 8' BFG 1 6 119.8 28.6 31.4 91.2 95 954 450' N & 100' W of SE corner of pad 7' BFG 1 6 119.8 28.8 31.6 91.0 95 955 450' N & 100' W of SE corner of pad 6' BFG 1 6 119.9 28.6 31.3 91.3 95 Bldg, Pad B 956 50' N & 20' W of SE corner of pad 10' BFG 1 6 120.6 28.9 31.5 91.7 95 957 50' N & 20' W of SE corner of pad 9' BFG 1 6 120.0 28.6 31.3 91.4 95 958 50' N & 20' W of SE corner of pad 8' BFG 1 6 119.6 28.4 31.1 91.2 95 959 50' N & 20' W of SE corner of pad 7' BFG 1 6 120.2 28.7 31.4 91.5 95 960 50' N & 20' W of SE corner of pad 6' BFG 1 6 119.6 28.5 31.3 91.1 95 961 50' N & 80' W of SE corner of pad 10' BFG 1 6 120.0 28.7 31.4 91.3 95 962 50' N & 80' W of SE corner of pad 9' BFG 1 6 119.3 28.3 31.1 91.0 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0026 06/10/14 06/17/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 963 50' N & 80' W of SE corner of pad 8' BFG 1 6 120.2 28.8 31.5 91.4 95 964 50' N & 80' W of SE corner of pad 7' BFG 1 6 120.0 28.5 31.2 91.5 95 965 50' N & 80' W of SE corner of pad 6' BFG 1 6 120.0 28.7 31.4 91.3 95 966 50' N & 130' W of SE corner of pad 10' BFG 1 6 119.8 28.8 31.7 91.0 95 967 50' N & 130' W of SE corner of pad 9' BFG 1 6 120.2 28.8 31.5 91.4 95 968 50' N & 130' W of SE corner of pad 8' BFG 1 6 119.7 28.5 31.3 91.2 95 969 50' N & 130' W of SE corner of pad 7' BFG 1 6 119.9 28.8 31.6 91.1 95 970 50' N & 130' W of SE corner of pad 6' BFG 1 6 119.8 28.5 31.2 91.3 95 Bldg. Pad D 971 480' N & 20' W of SE corner of pad 10' BFG 1 6 119.9 28.8 31.6 91.1 95 972 480' N & 20' W of SE corner of pad 9' BFG 1 6 120.0 28.7 31.4 91.3 95 973 480' N & 20' W of SE corner of pad 8' BFG 1 6 119.4 28.5 31.3 90.9 94 974 480' N & 20' W of SE corner of pad 7' BFG 1 6 119.7 28.7 31.5 91.0 95 975 480' N & 20' W of SE corner of pad 6' BFG 1 6 120.1 28.9 31.7 91.2 95 976 480' N & 100' W of SE corner of pad 10' BFG 1 6 120.3 28.6 31.2 91.7 95 977 480' N & 100' W of SE corner of pad 9' BFG 1 6 119.5 28.3 31.0 91.2 95 978 480' N & 100' W of SE corner of pad 8' BFG 1 6 120.1 28.6 31.3 91.5 95 979 480' N & 100' W of SE corner of pad 7' BFG 1 6 120.1 28.8 31.5 91.3 95 980 480' N & 100' W of SE corner of pad 6' BFG 1 6 120.4 28.8 31.4 91.6 95 981 480' N & 180' W of SE corner of pad 10' BFG 1 6 120.2 28.9 31.7 91.3 95 982 480' N & 180' W of SE corner of pad 9' BFG 1 6 120.4 28.8 31.4 91.6 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0026 06/10/14 06/17/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 983 480' N & 180' W of SE corner of pad 8' BFG 1 6 120.0 28.8 31.6 91.2 95 984 480' N & 180' W of SE corner of pad 7' BFG 1 6 120.0 28.6 31.3 91.4 95 985 480' N & 180' W of SE corner of pad 6' BFG 1 6 119.8 28.7 31.5 91.1 95 Bldg. Pad B 986 50' N & 20' W of SE corner of pad 5' BFG 1 6 120.2 28.3 30.8 91.9 96 987 50' N & 20' W of SE corner of pad 4' BFG 1 6 119.3 27.9 30.5 91.4 95 988 50' N & 20' W of SE corner of pad 3' BFG 1 6 119.9 28.2 30.7 91.7 95 989 50' N & 20' W of SE corner of pad 2' BFG 1 6 119.8 28.3 30.9 91.5 95 990 50' N & 20' W of SE corner of pad 1' BFG 1 6 119.6 28.0 30.6 91.6 95 991 50' N & 80' W of SE corner of pad 5' BFG 1 6 120.3 28.5 31.0 91.8 95 992 50' N & 80' W of SE corner of pad 4' BFG 1 6 119.7 28.1 30.7 91.6 95 993 50' N & 80' W of SE corner of pad 3' BFG 1 6 119.1 27.8 30.5 91.3 95 994 50' N & 80' W of SE corner of pad 2' BFG 1 6 119.7 28.2 30.8 91.5 95 995 50' N & 80' W of SE corner of pad 1' BFG 1 6 119.8 28.1 30.6 91.7 95 996 50' N & 130' W of SE corner of pad 5' BFG 1 6 118.8 27.7 30.4 91.1 95 997 50' N & 130' W of SE corner of pad 4' BFG 1 6 119.5 28.1 30.7 91.4 95 998 50' N & 130' W of SE corner of pad 3' BFG 1 6 119.2 28.1 30.8 91.1 95 999 50' N & 130' W of SE corner of pad 2' BFG 1 6 119.4 28.0 30.6 91.4 95 1000 50' N & 130' W of SE corner of pad 1' BFG 1 6 119.4 28.2 30.9 91.2 95 Bldg. Pad D 1001 480' N & 20' W of SE corner of pad 5' BFG 1 6 119.9 28.2 30.7 91.7 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 4 of 6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0026 06/10/14 06/17/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1002 480' N & 20' W of SE corner of pad 4' BFG 1 6 120.0 28.5 31.2 91.5 95 1003 480' N & 20' W of SE corner of pad 3' BFG 1 6 120.4 28.5 31.0 91.9 96 1004 480' N & 20' W of SE corner of pad 2' BFG 1 6 120.1 28.7 31.4 91.4 95 1005 480' N & 20' W of SE corner of pad 1' BFG 1 6 120.1 28.5 31.1 91.6 95 1006 480' N & 100' W of SE corner of pad 5' BFG 1 6 119.8 28.1 30.6 91.7 95 1007 480' N & 100' W of SE corner of pad 4' BFG 1 6 120.3 28.4 30.9 91.9 96 1008 480' N & 100' W of SE corner of pad 3' BFG 1 6 120.0 28.5 31.2 91.5 95 1009 480' N & 100' W of SE corner of pad 2' BFG 1 6 120.1 28.4 31.0 91.7 95 1010 480' N & 100' W of SE corner of pad 1' BFG 1 6 119.8 28.6 31.4 91.2 95 1011 480' N & 180' W of SE corner of pad 5' BFG 1 6 118.9 27.9 30.7 91.0 95 1012 480' N & 180' W of SE corner of pad 4' BFG 1 6 119.6 28.2 30.9 91.4 95 1013 480' N & 180' W of SE corner of pad 3' BFG 1 6 119.1 27.9 30.6 91.2 95 1014 480' N & 180' W of SE corner of pad 2' BFG 1 6 119.2 27.7 30.3 91.5 95 1015 480' N & 180' W of SE corner of pad 1' BFG 1 6 119.1 27.8 30.5 91.3 95 Bldg. Pad B 1016 80' N & 20' W of SE corner of pad 10' BFG 1 6 119.2 27.6 30.1 91.6 95 1017 80' N & 20' W of SE corner of pad 9' BFG 1 6 119.6 28.1 30.7 91.5 95 1018 80' N & 20' W of SE corner of pad 8' BFG 1 6 118.9 27.8 30.5 91.1 95 1019 80' N & 80' W of SE corner of pad 10' BFG 1 6 119.6 28.2 30.8 91.4 95 1020 80' N & 80' W of SE corner of pad 9' BFG 1 6 118.7 27.7 30.4 91.0 95 1021 80' N & 80' W of SE corner of pad 8' BFG 1 6 119.8 28.3 30.9 91.5 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 5 of 6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0026 06/10/14 06/17/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1022 80' N & 130' W of SE corner of pad 10' BFG 1 6 119.2 28.0 30.7 91.2 95 1023 80' N & 130' W of SE corner of pad 9' BFG 1 6 119.3 27.9 30.5 91.4 95 1024 80' N & 130' W of SE corner of pad 8' BFG 1 6 119.2 28.1 30.8 91.1 95 Bldg. Pad D 1025 510' N & 20' W of SE corner of pad 10' BFG 1 6 119.3 27.9 30.5 91.4 95 1026 510' N & 20' W of SE corner of pad 9' BFG 1 6 119.9 28.2 30.7 91.7 95 1027 510' N & 20' W of SE corner of pad 8' BFG 1 6 119.4 27.8 30.4 91.6 95 1028 510' N & 100' W of SE corner of pad 10' BFG 1 6 119.6 27.7 30.1 91.9 96 1029 510' N & 100' W of SE corner of pad 9' BFG 1 6 119.2 27.7 30.3 91.5 95 1030 510' N & 100' W of SE corner of pad 8' BFG 1 6 119.8 28.0 30.5 91.8 95 1031 510' N & 180' W of SE corner of pad 10' BFG 1 6 119.2 27.9 30.6 91.3 95 1032 510' N & 180' W of SE corner of pad 9' BFG 1 6 119.1 27.6 30.2 91.5 95 1033 510' N & 180' W of SE corner of pad 8' BFG 1 6 118.6 27.4 30.0 91.2 95 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 6 of 6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0027 06/11/14 06/17/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +2196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad D 1034 510' N & 20' W of SE corner of pad 7' BFG 1 6 119.3 28.1 30.8 91.2 95 1035 510' N & 20' W of SE corner of pad 6' BFG 1 6 118.8 27.8 30.6 91.0 95 1036 510' N & 20' W of SE corner of pad 5' BFG 1 6 119.6 28.2 30.9 91.4 95 1037 510' N & 20' W of SE corner of pad 4' BFG 1 6 118.9 27.8 30.5 91.1 95 1038 510' N & 20' W of SE corner of pad 3' BFG 1 6 119.3 28.0 30.7 91.3 95 1039 510' N & 20' W of SE corner of pad 2' BFG 1 6 119.3 27.8 30.4 91.5 95 1040 510' N & 20' W of SE corner of pad 1' BFG 1 6 119.1 27.9 30.6 91.2 95 1041 510' N & 100' W of SE corner of pad 7' BFG 1 6 119.6 28.1 30.7 91.5 95 1042 510' N & 100' W of SE corner of pad 6' BFG 1 6 119.7 27.9 30.4 91.8 95 1043 510' N & 100' W of SE corner of pad 5' BFG 1 6 119.0 27.6 30.2 91.4 95 1044 510' N & 100' W of SE corner of pad 4' BFG 1 6 119.7 28.0 30.5 91.7 95 1045 510' N & 100' W of SE corner of pad 3' BFG 1 6 119.2 27.7 30.3 91.5 95 1046 510' N & 100' W of SE corner of pad 2' BFG 1 6 119.8 28.4 31.1 91.4 95 1047 510' N & 100' W of SE corner of pad 1' BFG 1 6 119.5 28.3 31.0 91.2 95 1048 510' N & 180' W of SE corner of pad 7' BFG 1 6 118.9 27.9 30.7 91.0 95 1049 510' N & 180' W of SE corner of pad 6' BFG 1 6 119.8 28.3 30.9 91.5 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0027 06/11/14 06/17/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1050 510' N & 180' W of SE corner of pad 5' BFG 1 6 119.8 28.5 31.2 91.3 95 1051 510' N & 180' W of SE corner of pad 4' BFG 1 6 120.0 28.9 31.7 91.1 95 1052 510' N & 180' W of SE corner of pad 3' BFG 1 6 120.5 28.9 31.5 91.6 95 1053 510' N & 180' W of SE corner of pad 2' BFG 1 6 120.5 28.7 31.3 91.8 95 1054 510' N & 180' W of SE corner of pad 1' BFG 1 6 119.7 28.3 31.0 91.4 95 Bldg. Pad B 1055 80' N & 20' W of SE corner of pad 7' BFG 1 6 120.0 28.7 31.4 91.3 95 1056 80' N & 20' W of SE corner of pad 6' BFG 1 6 120.2 28.6 31.2 91.6 95 1057 80' N & 20' W of SE corner of pad 5' BFG 1 6 119.8 28.4 31.1 91.4 95 1058 80' N & 80' W of SE corner of pad 7' BFG 1 6 119.8 28.2 30.8 91.6 95 1059 80' N & 80' W of SE corner of pad 6' BFG 1 6 119.7 28.4 31.1 91.3 95 1060 80' N & 80' W of SE corner of pad 5' BFG 1 6 119.6 28.6 31.4 91.0 95 1061 80' N & 130' W of SE corner of pad 7' BFG 1 6 119.7 28.5 31.2 91.2 95 1062 80' N & 130' W of SE corner of pad 6' BFG 1 6 120.5 28.9 31.5 91.6 95 1063 80' N & 130' W of SE corner of pad 5' BFG 1 6 120.0 28.7 31.4 91.3 95 Bldg. Pad D 1064 540' N & 20' W of SE corner of pad 10' BFG 1 6 119.9 28.9 31.8 91.0 95 1065 540' N & 20' W of SE corner of pad 9' BFG 1 6 120.2 28.8 31.5 91.4 95 1066 540' N & 20' W of SE corner of pad 8' BFG 1 6 119.7 28.5 31.2 91.2 95 1067 540' N & 20' W of SE corner of pad 7' BFG 1 6 119.7 28.6 31.4 91.1 95 1068 540' N & 20' W of SE corner of pad 6' BFG 1 6 120.0 28.5 31.1 91.5 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0027 06/11/14 06/17/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1069 540' N & 100' W of SE corner of pad 10' BFG 1 6 119.9 28.8 31.6 91.1 95 1070 540' N & 100' W of SE corner of pad 9' BFG 1 6 119.6 28.6 31.4 91.0 95 1071 540' N & 100' W of SE corner of pad 8' BFG 1 6 119.6 28.8 31.7 90.8 94 1072 540' N & 100' W of SE corner of pad 7' BFG 1 6 119.9 28.7 31.5 91.2 95 1073 540' N & 100' W of SE corner of pad 6' BFG 1 6 120.0 28.6 31.3 91.4 95 1074 540' N & 180' W of SE corner of pad 10' BFG 1 6 120.6 28.9 31.5 91.7 95 1075 540' N & 180' W of SE corner of pad 9' BFG 1 6 120.0 28.6 31.3 91.4 95 1076 540' N & 180' W of SE corner of pad 8' BFG 1 6 119.4 28.3 31.1 91.1 95 1077 540' N & 180' W of SE corner of pad 7' BFG 1 6 120.5 28.9 31.6 91.6 95 1078 540' N & 180' W of SE corner of pad 6' BFG 1 6 120.0 28.5 31.2 91.5 95 1079 540' N & 20' W of SE corner of pad 5' BFG 1 6 119.4 28.2 30.9 91.2 95 1080 540' N & 20' W of SE corner of pad 4' BFG 1 6 118.7 27.8 30.6 90.9 94 1081 540' N & 20' W of SE corner of pad 3' BFG 1 6 119.0 27.7 30.3 91.3 95 1082 540' N & 20' W of SE corner of pad 2' BFG 1 6 118.8 27.8 30.5 91.0 95 1083 540' N & 20' W of SE corner of pad 1' BFG 1 6 119.2 27.8 30.4 91.4 95 1084 540' N & 100' W of SE corner of pad 5' BFG 1 6 119.2 28.3 31.1 90.9 94 1085 540' N & 100' W of SE corner of pad 4' BFG 1 6 119.6 28.2 30.8 91.4 95 1086 540' N & 100' W of SE corner of pad 3' BFG 1 6 118.9 27.8 30.5 91.1 95 1087 540' N & 100' W of SE corner of pad 2' BFG 1 6 119.6 28.1 30.7 91.5 95 1088 540' N & 100' W of SE corner of pad 1' BFG 1 6 119.2 27.9 30.6 91.3 95 1089 540' N & 180' W of SE corner of pad 5' BFG 1 6 119.5 28.1 30.7 91.4 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0027 06/11/14 06/17/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1090 540' N & 180' W of SE corner of pad 4' BFG 1 6 119.8 28.0 30.5 91.8 95 1091 540' N & 180' W of SE corner of pad 3' BFG 1 6 119.1 27.9 30.6 91.2 95 1092 540' N & 180' W of SE corner of pad 2' BFG 1 6 119.1 28.1 30.9 91.0 95 1093 540' N & 180' W of SE corner of pad 1' BFG 1 6 119.5 28.1 30.7 91.4 95 Bldg. Pad B 1094 80' N & 20' W of SE corner of pad 4' BFG 1 6 119.1 27.8 30.5 91.3 95 1095 80' N & 20' W of SE corner of pad 3' BFG 1 6 119.9 28.2 30.7 91.7 95 1096 80' N & 20' W of SE corner of pad 2' BFG 1 6 119.8 28.3 30.9 91.5 95 1097 80' N & 20' W of SE corner of pad 1' BFG 1 6 119.9 28.1 30.6 91.8 95 1098 80' N & 80' W of SE corner of pad 4' BFG 1 6 119.6 28.2 30.8 91.4 95 1099 80' N & 80' W of SE corner of pad 3' BFG 1 6 119.7 28.6 31.4 91.1 95 1100 80' N & 80' W of SE corner of pad 2' BFG 1 6 119.8 28.5 31.2 91.3 95 1101 80' N & 80' W of SE corner of pad 1' BFG 1 6 119.7 28.3 31.0 91.4 95 1102 80' N & 130' W of SE corner of pad 4' BFG 1 6 119.1 28.1 30.9 91.0 95 1103 80' N & 130' W of SE corner of pad 3' BFG 1 6 119.7 28.4 31.1 91.3 95 1104 80' N & 130' W of SE corner of pad 2' BFG 1 6 119.2 28.1 30.8 91.1 95 1105 80' N & 130' W of SE corner of pad 1' BFG 1 6 119.4 28.0 30.6 91.4 95 Bldg. Pad 1106 110' N & 20' W of SE corner of pad 10' BFG 1 6 119.8 28.3 30.9 91.5 95 1107 110' N & 20' W of SE corner of pad 9' BFG 1 6 118.9 27.9 30.7 91.0 95 1108 110' N & 20' W of SE corner of pad 8' BFG 1 6 119.0 27.8 30.5 91.2 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 4 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0027 06/11/14 06/17/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1109 110' N & 80' W of SE corner of pad 10' BFG 1 6 119.4 27.8 30.3 91.6 95 1110 110' N & 80' W of SE corner of pad 9' BFG 1 6 119.1 28.0 30.7 91.1 95 1111 110' N & 80' W of SE corner of pad 8' BFG 1 6 119.8 28.0 30.5 91.8 95 1112 110' N & 130' W of SE corner of pad 10' BFG 1 6 119.8 28.3 30.9 91.5 95 1113 110' N & 130' W of SE corner of pad 9' BFG 1 6 119.3 28.0 30.7 91.3 95 1114 110' N & 130' W of SE corner of pad 8' BFG 1 6 118.8 27.7 30.4 91.1 95 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 5 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0028 06/12/14 06/18/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad D 1115 570' N & 20' W of SE corner of pad 10' BFG 1 6 118.5 28.3 31.4 90.2 94 1116 570' N & 20' W of SE corner of pad 9' BFG 1 6 118.6 28.6 31.8 90.0 94 1117 570' N & 20' W of SE corner of pad 8' BFG 1 6 118.7 28.4 31.5 90.3 94 1118 570' N & 20' W of SE corner of pad 7' BFG 1 6 118.8 28.7 31.9 90.1 94 1119 570' N & 20' W of SE corner of pad 6' BFG 1 6 119.1 28.7 31.7 90.4 94 1120 570' N & 100' W of SE corner of pad 10' BFG 1 6 119.4 28.6 31.5 90.8 94 1121 570' N & 100' W of SE corner of pad 9' BFG 1 6 119.0 28.4 31.3 90.6 94 1122 570' N & 100' W of SE corner of pad 8' BFG 1 6 119.6 28.7 31.6 90.9 94 1123 570' N & 100' W of SE corner of pad 7' BFG 1 6 119.5 28.4 31.2 91.1 95 1124 570' N & 100' W of SE corner of pad 6' BFG 1 6 119.2 28.5 31.4 90.7 94 1125 570' N & 180' W of SE corner of pad 10' BFG 1 6 119.8 28.8 31.7 91.0 95 1126 570' N & 180' W of SE corner of pad 9' BFG 1 6 119.7 28.9 31.8 90.8 94 1127 570' N & 180' W of SE corner of pad 8' BFG 1 6 120.0 28.8 31.6 91.2 95 1128 570' N & 180' W of SE corner of pad 7' BFG 1 6 120.0 29.0 31.9 91.0 95 1129 570' N & 180' W of SE corner of pad 6' BFG 1 6 119.6 28.8 31.7 90.8 94 Bldg. Pad B The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0028 06/12/14 06/18/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1130 110' N & 20' W of SE corner of pad 7' BFG 1 6 120.2 28.8 31.5 91.4 95 1131 110' N & 20' W of SE corner of pad 6' BG 1 6 120.1 29.0 31.8 91.1 95 1132 110' N & 20' W of SE corner of pad 5' BFG 1 6 120.5 28.9 31.6 91.6 95 1133 110' N & 20' W of SE corner of pad 4' BFG 1 6 120.4 29.1 31.9 91.3 95 1134 110' N & 20' W of SE corner of pad 3' BFG 1 6 120.5 28.8 31.4 91.7 95 1135 110' N & 20' W of SE corner of pad 2' BFG 1 6 120.0 28.5 31.2 91.5 95 1136 110' N & 20' W of SE corner of pad 1' BFG 1 6 120.0 28.8 31.6 91.2 95 1137 110' N & 80' W of SE corner of pad 7' BFG 1 6 120.3 28.8 31.5 91.5 95 1138 110' N & 80' W of SE corner of pad 6' BFG 1 6 120.4 28.7 31.3 91.7 95 1139 110' N & 80' W of SE corner of pad 5' BFG 1 6 119.8 28.5 31.2 91.3 95 1140 110' N & 80' W of SE corner of pad 4' BFG 1 6 119.9 28.4 31.0 91.5 95 1141 110' N & 80' W of SE corner of pad 3' BFG 1 6 119.8 28.6 31.4 91.2 95 1142 110' N & 80' W of SE corner of pad 2' BFG 1 6 120.3 28.9 31.6 91.4 95 1143 110' N & 80' W of SE corner of pad 1' BFG 1 6 120.4 28.7 31.3 91.7 95 1144 110' N & 130' W of SE corner of pad 7' BFG 1 6 120.2 28.8 31.5 91.4 95 1145 110' N & 130' W of SE corner of pad 6' BFG 1 6 120.4 28.7 31.3 91.7 95 1146 110' N & 130' W of SE corner of pad 5' BFG 1 6 120.9 29.0 31.6 91.9 96 1147 110' N & 130' W of SE corner of pad 4' BFG 1 6 120.0 28.5 31.2 91.5 95 1148 110' N & 130' W of SE corner of pad 3' BFG 1 6 120.0 28.7 31.4 91.3 95 1149 110' N & 130' W of SE corner of pad 2' BFG 1 6 120.5 28.9 31.5 91.6 95 1150 110' N & 130' W of SE corner of pad 1' BFG 1 6 120.0 28.6 31.3 91.4 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0028 06/12/14 06/18/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad D 1151 570' N & 20' W of SE corner of pad 5' BFG 1 6 119.8 28.6 31.4 91.2 95 1152 570' N & 20' W of SE corner of pad 4' BFG 1 6 120.6 29.0 31.7 91.6 95 1153 570' N & 20' W of SE corner of pad 3' BFG 1 6 120.1 28.8 31.5 91.3 95 1154 570' N & 20' W of SE corner of pad 2' BFG 1 6 120.9 29.2 31.8 91.7 95 1155 570' N & 20' W of SE corner of pad 1' BFG 1 6 120.4 28.9 31.6 91.5 95 1156 570' N & 80' W of SE corner of pad 5' BFG 1 6 121.1 29.2 31.8 91.9 96 1157 570' N & 80' W of SE corner of pad 4' BFG 1 6 120.2 28.7 31.4 91.5 95 1158 570' N & 80' W of SE corner of pad 3' BFG 1 6 120.8 29.1 31.7 91.7 95 1159 570' N & 80' W of SE corner of pad 2' BFG 1 6 120.2 28.8 31.5 91.4 95 1160 570' N & 80' W of SE corner of pad 1' BFG 1 6 120.3 28.7 31.3 91.6 95 1161 570' N & 180' W of SE corner of pad 5' BFG 1 6 120.4 28.6 31.2 91.8 95 1162 570' N & 180' W of SE corner of pad 4' BFG 1 6 120.2 28.7 31.4 91.5 95 1163 570' N & 180' W of SE corner of pad 3' BFG 1 6 119.5 28.4 31.2 91.1 95 1164 570' N & 180' W of SE corner of pad 2' BFG 1 6 120.2 28.9 31.7 91.3 95 1165 570' N & 180' W of SE corner of pad 1' BFG 1 6 119.7 28.7 31.5 91.0 95 1166 600' N & 20' W of SE corner of pad 10' BFG 1 6 119.8 28.8 31.6 91.0 95 1167 600' N & 20' W of SE corner of pad 9' BFG 1 6 120.1 28.7 31.4 91.4 95 1168 600' N & 20' W of SE corner of pad 8' BFG 1 6 120.2 28.5 31.1 91.7 95 1169 600' N & 20' W of SE corner of pad 7' BFG 1 6 119.9 28.7 31.5 91.2 95 1170 600' N & 20' W of SE corner of pad 6' BFG 1 6 120.1 28.6 31.3 91.5 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0028 06/12/14 06/18/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1171 600' N & 100' W of SE corner of pad 10' BFG 1 6 120.2 28.5 31.1 91.7 95 1172 600' N & 100' W of SE corner of pad 9' BFG 1 6 119.8 28.6 31.4 91.2 95 1173 600' N & 100' W of SE corner of pad 8' BFG 1 6 120.5 29.0 31.7 91.5 95 1174 600' N & 100' W of SE corner of pad 7' BFG 1 6 120.0 28.7 31.4 91.3 95 1175 600' N & 100' W of SE corner of pad 6' BFG 1 6 119.5 28.4 31.2 91.1 95 1176 600' N & 180' W of SE corner of pad 10' BFG 1 6 120.5 28.9 31.5 91.6 95 1177 600' N & 180' W of SE corner of pad 9' BFG 1 6 119.4 28.4 31.2 91.0 95 1178 600' N & 180' W of SE corner of pad 8' BFG 1 6 120.2 28.8 31.5 91.4 95 1179 600' N & 180' W of SE corner of pad 7' BFG 1 6 120.5 28.7 31.3 91.8 95 1180 600' N & 180' W of SE corner of pad 6' BFG 1 6 120.4 28.9 31.6 91.5 95 1181 600' N & 20' W of SE corner of pad 5' BFG 1 6 119.8 28.8 31.7 91.0 95 1182 600' N & 20' W of SE corner of pad 4' BFG 1 6 120.2 28.8 31.5 91.4 95 1183 600' N & 20' W of SE corner of pad 3' BFG 1 6 119.7 28.5 31.3 91.2 95 1184 600' N & 20' W of SE corner of pad 2' BFG 1 6 120.6 29.1 31.8 91.5 95 1185 600' N & 20' W of SE corner of pad 1' BFG 1 6 120.0 28.7 31.4 91.3 95 1186 600' N & 100' W of SE corner of pad 5' BFG 1 6 120.4 28.7 31.3 91.7 95 1187 600' N & 100' W of SE corner of pad 4' BFG 1 6 120.4 28.5 31.0 91.9 96 1188 600' N & 100' W of SE corner of pad 3' BFG 1 6 120.4 28.8 31.4 91.6 95 1189 600' N & 100' W of SE corner of pad 2' BFG 1 6 120.4 28.6 31.2 91.8 95 1190 600' N & 100' W of SE corner of pad 1' BFG 1 6 120.7 28.9 31.5 91.8 95 1191 600' N & 180' W of SE corner of pad 5' BFG 1 6 120.2 28.6 31.2 91.6 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 4 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0028 06/12/14 06/18/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1192 600' N & 180' W of SE corner of pad 4' BFG 1 6 120.0 28.8 31.6 91.2 95 1193 600' N & 180' W of SE corner of pad 3' BFG 1 6 120.0 28.6 31.3 91.4 95 1194 600' N & 180' W of SE corner of pad 2' BFG 1 6 120.8 29.1 31.7 91.7 95 1195 600' N & 180' W of SE corner of pad 1' BFG 1 6 119.9 28.4 31.0 91.5 95 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place moisture and density retests as requested or as required by the project specifications to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 5 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0029 06/13/14 06/18/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad D 1196 630' N & 20' W of SE corner of pad 10' BFG 1 6 120.0 28.3 30.9 91.7 95 1197 630' N & 20' W of SE corner of pad 9' BFG 1 6 120.1 28.2 30.7 91.9 96 1198 630' N & 20' W of SE corner of pad 8' BFG 1 6 119.9 28.5 31.2 91.4 95 1199 630' N & 20' W of SE corner of pad 7' BFG 1 6 119.3 28.2 31.0 91.1 95 1200 630' N & 20' W of SE corner of pad 6' BFG 1 6 120.1 28.6 31.3 91.5 95 1201 630' N & 100' W of SE corner of pad 10' BFG 1 6 119.8 28.6 31.4 91.2 95 1202 630' N & 100' W of SE corner of pad 9' BFG 1 6 120.0 28.5 31.1 91.5 95 1203 630' N & 100' W of SE corner of pad 8' BFG 1 6 120.4 28.7 31.3 91.7 95 1204 630' N & 100' W of SE corner of pad 7' BFG 1 6 119.7 28.3 31.0 91.4 95 1205 630' N & 100' W of SE corner of pad 6' BFG 1 6 119.8 28.2 30.8 91.6 95 1206 630' N & 180' W of SE corner of pad 10' BFG 1 6 119.8 28.0 30.5 91.8 95 1207 630' N & 180' W of SE corner of pad 9' BFG 1 6 119.9 28.3 30.9 91.6 95 1208 630' N & 180' W of SE corner of pad 8' BFG 1 6 119.8 28.5 31.2 91.3 95 1209 630' N & 180' W of SE corner of pad 7' BFG 1 6 120.0 28.4 31.0 91.6 95 1210 630' N & 180' W of SE corner of pad 6' BFG 1 6 120.1 28.3 30.8 91.8 95 1211 630' N & 20' W of SE corner of pad 5' BFG 1 6 120.3 28.6 31.2 91.7 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 3 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0029 06/13/14 06/18/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1212 630' N & 20' W of SE corner of pad 4' BFG 1 6 119.7 28.2 30.8 91.5 95 1213 630' N & 20' W of SE corner of pad 3' BFG 1 6 120.3 28.5 31.0 91.8 95 1214 630' N & 20' W of SE corner of pad 2' BFG 1 6 119.6 28.2 30.9 91.4 95 1215 630' N & 20' W of SE corner of pad 1' BFG 1 6 120.1 28.2 30.7 91.9 96 1216 630' N & 100' W of SE corner of pad 5' BFG 1 6 119.4 28.4 31.2 91.0 95 1217 630' N & 100' W of SE corner of pad 4' BFG 1 6 118.9 28.1 31.0 90.8 94 1218 630' N & 100' W of SE corner of pad 3' BFG 1 6 119.2 28.0 30.7 91.2 95 1219 630' N & 100' W of SE corner of pad 2' BFG 1 6 119.6 28.2 30.9 91.4 95 1220 630' N & 100' W of SE corner of pad 1' BFG 1 6 119.8 28.1 30.6 91.7 95 1221 630' N & 180' W of SE corner of pad 5' BFG 1 6 120.2 28.4 30.9 91.8 95 1222 630' N & 180' W of SE corner of pad 4' BFG 1 6 120.2 28.7 31.4 91.5 95 1223 630' N & 180' W of SE corner of pad 3' BFG 1 6 119.7 28.5 31.2 91.2 95 1224 630' N & 180' W of SE corner of pad 2' BFG 1 6 119.7 28.3 31.0 91.4 95 1225 630' N & 180' W of SE corner of pad 1' BFG 1 6 119.7 28.6 31.4 91.1 95 1226 660' N & 20' W of SE corner of pad 10' BFG 1 6 120.3 28.6 31.2 91.7 95 1227 660' N & 20' W of SE corner of pad 9' BFG 1 6 120.2 28.7 31.4 91.5 95 1228 660' N & 20' W of SE corner of pad 8' BFG 1 6 120.3 28.5 31.0 91.8 95 1229 660' N & 20' W of SE corner of pad 7' BFG 1 6 120.5 28.9 31.5 91.6 95 1230 660' N & 20' W of SE corner of pad 6' BFG 1 6 119.9 28.6 31.3 91.3 95 1231 660' N & 100' W of SE corner of pad 10' BFG 1 6 119.7 28.7 31.5 91.0 95 1232 660' N & 100' W of SE corner of pad 9' BFG 1 6 119.6 28.8 31.7 90.8 94 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 3 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0029 06/13/14 06/18/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1233 660' N & 100' W of SE corner of pad 8' BFG 1 6 120.2 28.5 31.1 91.7 95 1234 660' N & 100' W of SE corner of pad 7' BFG 1 6 120.0 28.7 31.4 91.3 95 1235 660' N & 100' W of SE corner of pad 6' BFG 1 6 120.5 28.9 31.5 91.6 95 1236 600' N & 180' W of SE corner of pad 10' BFG 1 6 119.9 29.0 31.9 90.9 94 1237 600' N & 180' W of SE corner of pad 9' BFG 1 6 120.2 28.9 31.6 91.3 95 1238 600' N & 180' W of SE corner of pad 8' BFG 1 6 120.5 29.1 31.8 91.4 95 1239 600' N & 180' W of SE corner of pad 7' BFG 1 6 119.8 28.7 31.5 91.1 95 1240 600' N & 180' W of SE corner of pad 6' BFG 1 6 120.2 28.9 31.7 91.3 95 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 3 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0030 06/14/14 06/18/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 95-1/+3295.324.294141126.0001 Dark brown clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad D 1241 660' N & 20' W of SE corner of pad 5' BFG 1 6 120.0 28.5 31.1 91.5 95 1242 660' N & 20' W of SE corner of pad 4' BFG 1 6 119.4 28.1 30.8 91.3 95 1243 660' N & 20' W of SE corner of pad 3' BFG 1 6 120.4 28.8 31.4 91.6 95 1244 660' N & 20' W of SE corner of pad 2' BFG 1 6 120.3 28.6 31.2 91.7 95 1245 660' N & 20' W of SE corner of pad 1' BFG 1 6 119.7 28.3 31.0 91.4 95 1246 660' N & 100' W of SE corner of pad 5' BFG 1 6 120.3 28.6 31.2 91.7 95 1247 660' N & 100' W of SE corner of pad 4' BFG 1 6 120.2 28.8 31.5 91.4 95 1248 660' N & 100' W of SE corner of pad 3' BFG 1 6 119.6 28.4 31.1 91.2 95 1249 660' N & 100' W of SE corner of pad 2' BFG 1 6 120.5 29.0 31.7 91.5 95 1250 660' N & 100' W of SE corner of pad 1' BFG 1 6 119.9 28.7 31.5 91.2 95 1251 660' N & 180' W of SE corner of pad 5' BF 1 6 119.9 28.5 31.2 91.4 95 1252 660' N & 180' W of SE corner of pad 4' BFG 1 6 120.0 28.4 31.0 91.6 95 1253 660' N & 180' W of SE corner of pad 3' BFG 1 6 119.8 28.9 31.8 90.9 94 1254 660' N & 180' W of SE corner of pad 2' BFG 1 6 120.2 28.8 31.5 91.4 95 1255 660' N & 180' W of SE corner of pad 1' BFG 1 6 119.6 28.5 31.3 91.1 95 Storm Sewer, Line C The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0030 06/14/14 06/18/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1256 Sta. 6+00 2.4' BFG 2 6 116.3 23.2 24.9 93.1 98 1257 Sta. 6+00 1.6' BFG 2 6 116.2 23.4 25.2 92.8 97 1258 Sta. 6+00 8' BFG 2 6 115.6 23.1 25.0 92.5 97 1259 Sta. 6+00 Final 2 6 116.2 23.5 25.3 92.7 97 Bldg. Pad D 1260 690' N & 20' W of SE corner of pad 10' BFG 1 6 120.2 28.6 31.2 91.6 95 1261 690' N & 20' W of SE corner of pad 9' BFG 1 6 120.3 28.5 31.0 91.8 95 1262 690' N & 20' W of SE corner of pad 8' BFG 1 6 120.1 28.6 31.3 91.5 95 1263 690' N & 20' W of SE corner of pad 7' BFG 1 6 120.1 28.8 31.5 91.3 95 1264 690' N & 20' W of SE corner of pad 6' BFG 1 6 120.1 28.5 31.1 91.6 95 1265 690' N & 100' W of SE corner of pad 10' BFG 1 6 120.2 29.0 31.8 91.2 95 1266 690' N & 100' W of SE corner of pad 9' BFG 1 6 120.3 28.9 31.6 91.4 95 1267 690' N & 100' W of SE corner of pad 8' BFG 1 6 119.5 28.5 31.3 91.0 95 1268 690' N & 100' W of SE corner of pad 7' BFG 1 6 120.2 28.9 31.7 91.3 95 1269 690' N & 100' W of SE corner of pad 6' BFG 1 6 120.5 28.9 31.5 91.6 95 1270 690' N & 180' W of SE corner of pad 10' BFG 1 6 120.4 28.7 31.3 91.7 95 1271 690' N & 180' W of SE corner of pad 9' BFG 1 6 119.7 28.3 31.0 91.4 95 1272 690' N & 180' W of SE corner of pad 8' BFG 1 6 120.0 28.8 31.6 91.2 95 1273 690' N & 180' W of SE corner of pad 7' BFG 1 6 120.2 28.7 31.4 91.5 95 1274 690' N & 180' W of SE corner of pad 6' BFG 1 6 120.6 29.0 31.7 91.6 95 Storm Sewer, Line C 1275 Sta. 2+60 3.2' BFG 2 6 116.1 23.3 25.1 92.8 97 1276 Sta. 2+60 2.4' BFG 2 6 116.1 23.5 25.4 92.6 97 1277 Sta. 2+60 1.6' BFG 2 6 116.1 23.2 25.0 92.9 97 1278 Sta. 2+60 8' BFG 2 6 116.4 23.5 25.3 92.9 97 1279 Sta. 2+60 Final 2 6 116.6 23.4 25.1 93.2 98 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0030 06/14/14 06/18/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1280 690' N & 20' W of SE corner of pad 5' BFG 1 6 119.6 28.6 31.4 91.0 95 1281 690' N & 20' W of SE corner of pad 4' BFG 1 6 120.0 28.5 31.1 91.5 95 1282 690' N & 20' W of SE corner of pad 3' BFG 1 6 119.8 28.7 31.5 91.1 95 1283 690' N & 20' W of SE corner of pad 2' BFG 1 6 120.0 28.6 31.3 91.4 95 1284 690' N & 20' W of SE corner of pad 1' BFG 1 6 119.7 28.5 31.2 91.2 95 1285 690' N & 100' W of SE corner of pad 5' BFG 1 6 120.2 28.9 31.7 91.3 95 1286 690' N & 100' W of SE corner of pad 4' BFG 1 6 119.7 28.7 31.5 91.0 95 1287 690' N & 100' W of SE corner of pad 3' BFG 1 6 120.1 28.6 31.3 91.5 95 1288 690' N & 100' W of SE corner of pad 2' BFG 1 6 120.7 29.0 31.6 91.7 95 1289 690' N & 100' W of SE corner of pad 1' BFG 1 6 120.5 29.1 31.8 91.4 95 1290 690' N & 180' W of SE corner of pad 5' BFG 1 6 119.9 28.9 31.8 91.0 95 1291 690' N & 180' W of SE corner of pad 4' BFG 1 6 120.2 28.8 31.5 91.4 95 1292 690' N & 180' W of SE corner of pad 3' BFG 1 6 119.7 28.5 31.3 91.2 95 1293 690' N & 180' W of SE corner of pad 2' BFG 1 6 120.4 28.9 31.6 91.5 95 1294 690' N & 180' W of SE corner of pad 1' BFG 1 6 120.8 29.1 31.7 91.7 95 Storm Sewer, Line C 1295 Sta. 4+60 3.2' BFG 2 6 116.2 23.8 25.8 92.4 97 1296 Sta. 4+60 2.4' BFG 2 6 115.7 23.6 25.6 92.1 97 1297 Sta. 4+60 1.6' BFG 2 6 116.5 24.0 25.9 92.5 97 1298 Sta. 4+60 0.8' BFG 2 6 116.0 23.7 25.7 92.3 97 1299 Sta. 4+60 Final 2 6 115.5 23.5 25.5 92.0 97 Bldg. Pad D 1300 710' N & 20' W of SE corner of pad 10' BFG 1 6 120.4 28.8 31.4 91.6 95 1301 710' N & 20' W of SE corner of pad 9' BFG 1 6 120.3 28.5 31.1 91.8 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0030 06/14/14 06/18/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1302 710' N & 20' W of SE corner of pad 8' BFG 1 6 120.1 28.9 31.7 91.2 95 1303 710' N & 20' W of SE corner of pad 7' BFG 1 6 120.2 28.8 31.5 91.4 95 1304 710' N & 20' W of SE corner of pad 6' BFG 1 6 119.6 28.5 31.3 91.1 95 1305 710' N & 100' W of SE corner of pad 10' BFG 1 6 120.6 29.1 31.8 91.5 95 1306 710' N & 100' W of SE corner of pad 9' BFG 1 6 120.0 28.7 31.4 91.3 95 1307 710' N & 100' W of SE corner of pad 8' BFG 1 6 119.4 28.4 31.2 91.0 95 1308 710' N & 100' W of SE corner of pad 7' BFG 1 6 120.6 29.0 31.7 91.6 95 1309 710' N & 100' W of SE corner of pad 6' BFG 1 6 120.2 28.9 31.6 91.3 95 1310 710' N & 180' W of SE corner of pad 10' BFG 1 6 119.9 28.3 30.9 91.6 95 1311 710' N & 180' W of SE corner of pad 9' BFG 1 6 120.6 28.8 31.4 91.8 95 1312 710' N & 180' W of SE corner of pad 8' BFG 1 6 120.0 28.5 31.2 91.5 95 1313 710' N & 180' W of SE corner of pad 7' BFG 1 6 120.6 28.9 31.5 91.7 95 1314 710' N & 180' W of SE corner of pad 6' BFG 1 6 120.0 28.6 31.3 91.4 95 1315 710' N & 20' W of SE corner of pad 5' BFG 1 6 120.7 28.8 31.3 91.9 96 1316 710' N & 20' W of SE corner of pad 4' BFG 1 6 120.1 28.4 31.0 91.7 95 1317 710' N & 20' W of SE corner of pad 3' BFG 1 6 120.3 28.8 31.5 91.5 95 1318 710' N & 20' W of SE corner of pad 2' BFG 1 6 120.4 28.6 31.2 91.8 95 1319 710' N & 20' W of SE corner of pad 1' BFG 1 6 120.3 28.9 31.6 91.4 95 1320 710' N & 100' W of SE corner of pad 5' BFG 1 6 120.5 28.8 31.4 91.7 95 1321 710' N & 100' W of SE corner of pad 4' BFG 1 6 120.0 28.5 31.1 91.5 95 1322 710' N & 100' W of SE corner of pad 3' BFG 1 6 120.0 28.4 31.0 91.6 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 4 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0030 06/14/14 06/18/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1323 710' N & 100' W of SE corner of pad 2' BFG 1 6 120.2 28.9 31.6 91.3 95 1324 710' N & 100' W of SE corner of pad 1' BFG 1 6 120.5 28.8 31.4 91.7 95 1325 710' N & 180' W of SE corner of pad 5' BFG 1 6 120.3 28.7 31.3 91.6 95 1326 710' N & 180' W of SE corner of pad 4' BFG 1 6 120.6 28.9 31.5 91.7 95 1327 710' N & 180' W of SE corner of pad 3' BFG 1 6 120.4 28.9 31.6 91.5 95 1328 710' N & 180' W of SE corner of pad 2' BFG 1 6 120.3 28.6 31.2 91.7 95 1329 710' N & 180' W of SE corner of pad 1' BFG 1 6 120.1 28.7 31.4 91.4 95 Storm Sewer, Line C 1330 Sta. 6+20 3.2' BFG 2 6 116.9 24.0 25.8 92.9 97 1331 Sta. 6+20 2.4' BFG 2 6 117.1 23.9 25.6 93.2 98 1332 Sta. 6+20 1.6' BFG 2 6 116.5 23.5 25.3 93.0 98 1333 Sta. 6+20 0.8' BFG 2 6 116.6 23.8 25.7 92.8 97 1334 Sta. 6+20 Final 2 6 116.7 23.7 25.5 93.0 98 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 5 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0031 06/16/14 06/24/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg Pad B 1335 140' N & 20' W of SE corner of pad 10' BFG 1 6 119.9 28.3 30.9 91.6 95 1336 140' N & 20' W of SE corner of pad 9' BFG 1 6 120.6 28.8 31.4 91.8 95 1337 140' N & 20' W of SE corner of pad 8' BFG 1 6 120.0 28.5 31.1 91.5 95 1338 140' N & 20' W of SE corner of pad 7' BFG 1 6 120.4 28.7 31.3 91.7 95 1339 140' N & 20' W of SE corner of pad 6' BFG 1 6 120.4 28.5 31.0 91.9 96 1340 140' N & 80' W of SE corner of pad 10' BFG 1 6 120.0 28.5 31.2 91.5 95 1341 140' N & 80' W of SE corner of pad 9' BFG 1 6 120.7 29.0 31.6 91.7 95 1342 140' N & 80' W of SE corner of pad 8' BFG 1 6 119.6 28.4 31.1 91.2 95 1343 140' N & 80' W of SE corner of pad 7' BFG 1 6 119.7 28.7 31.5 91.0 95 1344 140' N & 80' W of SE corner of pad 6' BFG 1 6 120.0 28.6 31.3 91.4 95 1345 140' N & 130' W of SE corner of pad 10' BFG 1 6 119.9 28.8 31.6 91.1 95 1346 140' N & 130' W of SE corner of pad 9' BFG 1 6 120.2 28.6 31.2 91.6 95 1347 140' N & 130' W of SE corner of pad 8' BFG 1 6 120.5 29.1 31.8 91.4 95 1348 140' N & 130' W of SE corner of pad 7' BFG 1 6 119.8 28.8 31.6 91.0 95 1349 140' N & 130' W of SE corner of pad 6' BFG 1 6 120.0 28.5 31.2 91.5 95 1350 140' N & 20' W of SE corner of pad 5' BFG 1 6 120.1 28.4 31.0 91.7 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0031 06/16/14 06/24/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1351 140' N & 20' W of SE corner of pad 4' BFG 1 6 120.2 28.7 31.4 91.5 95 1352 140' N & 20' W of SE corner of pad 3' BFG 1 6 119.8 28.5 31.2 91.3 95 1353 140' N & 20' W of SE corner of pad 2' BFG 1 6 119.9 28.8 31.6 91.1 95 1354 140' N & 20' W of SE corner of pad 1' BFG 1 6 120.0 28.6 31.3 91.4 95 1355 140' N & 80' W of SE corner of pad 5' BFG 1 6 120.2 28.9 31.7 91.3 95 1356 140' N & 80' W of SE corner of pad 4' BFG 1 6 120.2 28.7 31.4 91.5 95 1357 140' N & 80' W of SE corner of pad 3' BFG 1 6 121.1 29.2 31.8 91.9 96 1358 140' N & 80' W of SE corner of pad 2' BFG 1 6 120.7 29.0 31.6 91.7 95 1359 140' N & 80' W of SE corner of pad 1' BFG 1 6 120.3 28.7 31.3 91.6 95 1360 140' N & 130' W of SE corner of pad 5' BFG 1 6 120.6 28.9 31.5 91.7 95 1361 140' N & 130' W of SE corner of pad 4' BFG 1 6 120.0 28.5 31.1 91.5 95 1362 140' N & 130' W of SE corner of pad 3' BFG 1 6 120.8 29.0 31.6 91.8 95 1363 140' N & 130' W of SE corner of pad 2' BFG 1 6 120.3 28.7 31.3 91.6 95 1364 140' N & 130' W of SE corner of pad 1' BFG 1 6 119.8 28.5 31.2 91.3 95 1365 170' N & 20' W of SE corner of pad 10' BFG 1 6 120.5 28.9 31.5 91.6 95 1366 170' N & 20' W of SE corner of pad 9' BFG 1 6 119.6 28.4 31.1 91.2 95 1367 170' N & 20' W of SE corner of pad 8' BFG 1 6 120.0 28.7 31.4 91.3 95 1368 170' N & 20' W of SE corner of pad 7' BFG 1 6 119.4 28.4 31.2 91.0 95 1369 170' N & 20' W of SE corner of pad 6' BFG 1 6 119.7 28.3 31.0 91.4 95 1370 170' N & 80' W of SE corner of pad 10' BFG 1 6 120.9 29.2 31.8 91.7 95 1371 170' N & 80' W of SE corner of pad 9' BFG 1 6 120.3 28.9 31.6 91.4 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0031 06/16/14 06/24/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1372 170' N & 80' W of SE corner of pad 8' BFG 1 6 119.8 28.6 31.4 91.2 95 1373 170' N & 80' W of SE corner of pad 7' BFG 1 6 119.8 28.8 31.7 91.0 95 1374 170' N & 80' W of SE corner of pad 6' BFG 1 6 120.1 28.8 31.5 91.3 95 1375 170' N & 130' W of SE corner of pad 10' BFG 1 6 120.5 28.9 31.6 91.6 95 1376 170' N & 130' W of SE corner of pad 9' BFG 1 6 119.6 28.4 31.1 91.2 95 1377 170' N & 130' W of SE corner of pad 8' BFG 1 6 119.5 28.5 31.3 91.0 95 1378 170' N & 130' W of SE corner of pad 7' BFG 1 6 120.2 28.8 31.5 91.4 95 1379 170' N & 130' W of SE corner of pad 6' BFG 1 6 120.2 28.6 31.2 91.6 95 1380 170' N & 20' W of SE corner of pad 5' BFG 1 6 120.4 28.8 31.4 91.6 95 1381 170' N & 20' W of SE corner of pad 4' BFG 1 6 120.4 28.6 31.2 91.8 95 1382 170' N & 20' W of SE corner of pad 3' BFG 1 6 119.9 28.4 31.0 91.5 95 1383 170' N & 20' W of SE corner of pad 2' BFG 1 6 120.1 28.8 31.5 91.3 95 1384 170' N & 20' W of SE corner of pad 1' BFG 1 6 120.4 28.7 31.3 91.7 95 1385 170' N & 80' W of SE corner of pad 5' BFG 1 6 120.6 28.8 31.4 91.8 95 1386 170' N & 80' W of SE corner of pad 4' BFG 1 6 120.0 28.5 31.2 91.5 95 1387 170' N & 80' W of SE corner of pad 3' BFG 1 6 119.9 28.7 31.5 91.2 95 1388 170' N & 80' W of SE corner of pad 2' BFG 1 6 119.8 28.8 31.7 91.0 95 1389 170' N & 80' W of SE corner of pad 1' BFG 1 6 120.0 28.6 31.3 91.4 95 1390 170' N & 130' W of SE corner of pad 5' BFG 1 6 120.8 29.0 31.6 91.8 95 1391 170' N & 130' W of SE corner of pad 4' BFG 1 6 122.9 31.4 34.3 91.5 95 1392 170' N & 130' W of SE corner of pad 3' BFG 1 6 120.9 29.2 31.8 91.7 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0031 06/16/14 06/24/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1393 170' N & 130' W of SE corner of pad 2' BFG 1 6 120.0 28.7 31.4 91.3 95 1394 170' N & 130' W of SE corner of pad 1' BFG 1 6 120.5 28.9 31.5 91.6 95 Bldg. Pad A 1395 20' N & 20' W of SE corner of pad 10' BFG 1 6 119.7 28.3 31.0 91.4 95 1396 20' N & 20' W of SE corner of pad 9' BFG 1 6 120.4 28.7 31.3 91.7 95 1397 20' N & 20' W of SE corner of pad 8' BFG 1 6 120.0 28.5 31.1 91.5 95 1398 20' N & 80' W of SE corner of pad 10' BFG 1 6 120.6 28.8 31.4 91.8 95 1399 20' N & 80' W of SE corner of pad 9' BFG 1 6 119.7 28.5 31.2 91.2 95 1400 20' N & 80' W of SE corner of pad 8' BFG 1 6 120.2 28.8 31.5 91.4 95 1401 20' N & 130' W of SE corner of pad 10' BFG 1 6 120.4 28.7 31.3 91.7 95 1402 20' N & 130' W of SE corner of pad 9' BFG 1 6 120.2 28.9 31.6 91.3 95 1403 20' N & 130' W of SE corner of pad 8' BFG 1 6 119.5 28.4 31.2 91.1 95 Bldg. Pad B 1404 200' N & 20' W of SE corner of pad 10' BFG 1 6 119.8 28.7 31.5 91.1 95 1405 200' N & 20' W of SE corner of pad 9' BFG 1 6 120.6 29.0 31.7 91.6 95 1406 200' N & 20' W of SE corner of pad 8' BFG 1 6 120.0 28.7 31.4 91.3 95 1407 200' N & 20' W of SE corner of pad 7' BFG 1 6 119.4 28.4 31.2 91.0 95 1408 200' N & 20' W of SE corner of pad 6' BFG 1 6 120.3 28.9 31.6 91.4 95 1409 200' N & 80' W of SE corner of pad 10' BFG 1 6 120.6 29.1 31.8 91.5 95 1410 200' N & 80' W of SE corner of pad 9' BFG 1 6 120.7 29.0 31.6 91.7 95 1411 200' N & 80' W of SE corner of pad 8' BFG 1 6 120.0 28.6 31.3 91.4 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 4 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0031 06/16/14 06/24/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1412 200' N & 80' W of SE corner of pad 7' BFG 1 6 119.9 28.7 31.5 91.2 95 1413 200' N & 80' W of SE corner of pad 6' BFG 1 6 120.2 28.6 31.2 91.6 95 1414 200' N & 130' W of SE corner of pad 10' BFG 1 6 120.5 29.0 31.7 91.5 95 1415 200' N & 130' W of SE corner of pad 9' BFG 1 6 119.9 28.7 31.5 91.2 95 1416 200' N & 130' W of SE corner of pad 8' BFG 1 6 119.9 28.5 31.2 91.4 95 1417 200' N & 130' W of SE corner of pad 7' BFG 1 6 119.8 28.7 31.5 91.1 95 1418 200' N & 130' W of SE corner of pad 6' BFG 1 6 120.6 29.0 31.7 91.6 95 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 5 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0032 06/17/14 06/24/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad A 1419 20' N & 20' W of SE corner of pad 7' BFG 1 6 120.0 28.3 30.9 91.7 95 1420 20' N & 20' W of SE corner of pad 6' BFG 1 6 120.2 28.7 31.4 91.5 95 1421 20' N & 20' W of SE corner of pad 5' BFG 1 6 119.7 28.4 31.1 91.3 95 1422 20' N & 20' W of SE corner of pad 4' BFG 1 6 120.4 28.6 31.2 91.8 95 1423 20' N & 20' W of SE corner of pad 3' BFG 1 6 120.5 28.9 31.5 91.6 95 1424 20' N & 20' W of SE corner of pad 2' BFG 1 6 119.7 28.5 31.2 91.2 95 1425 20' N & 20' W of SE corner of pad 1' BFG 1 6 119.9 28.8 31.6 91.1 95 1426 20' N & 80' W of SE corner of pad 7' BFG 1 6 120.3 28.6 31.2 91.7 95 1427 20' N & 80' W of SE corner of pad 6' BFG 1 6 119.9 28.4 31.0 91.5 95 1428 20' N & 80' W of SE corner of pad 5' BFG 1 6 120.0 28.7 31.4 91.3 95 1429 20' N & 80' W of SE corner of pad 4' BFG 1 6 120.2 28.6 31.2 91.6 95 1430 20' N & 80' W of SE corner of pad 3' BFG 1 6 120.7 28.9 31.5 91.8 95 1431 20' N & 80' W of SE corner of pad 2' BFG 1 6 120.4 28.8 31.4 91.6 95 1432 20' N & 80' W of SE corner of pad 1' BFG 1 6 120.2 28.9 31.7 91.3 95 1433 20' N & 130' W of SE corner of pad 7' BFG 1 6 120.2 28.8 31.5 91.4 95 1434 20' N & 130' W of SE corner of pad 6' BFG 1 6 119.9 28.9 31.8 91.0 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0032 06/17/14 06/24/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1435 20' N & 130' W of SE corner of pad 5' BFG 1 6 120.0 28.7 31.4 91.3 95 1436 20' N & 130' W of SE corner of pad 4' BFG 1 6 119.5 28.4 31.2 91.1 95 1437 20' N & 130' W of SE corner of pad 3' BFG 1 6 120.3 28.9 31.6 91.4 95 1438 20' N & 130' W of SE corner of pad 2' BFG 1 6 120.3 28.6 31.2 91.7 95 1439 20' N & 130' W of SE corner of pad 1' BFG 1 6 120.3 28.8 31.5 91.5 95 Bldg. Pad B 1440 200' N & 20' W of SE corner of pad 5' BFG 1 6 120.2 29.0 31.8 91.2 95 1441 200' N & 20' W of SE corner of pad 4' BFG 1 6 120.7 29.0 31.6 91.7 95 1442 200' N & 20' W of SE corner of pad 3' BFG 1 6 120.1 28.6 31.3 91.5 95 1443 200' N & 20' W of SE corner of pad 2' BFG 1 6 120.3 29.0 31.8 91.3 95 1444 200' N & 20' W of SE corner of pad 1' BFG 1 6 120.7 29.0 31.6 91.7 95 1445 200' N & 80' W of SE corner of pad 5' BFG 1 6 120.5 28.7 31.3 91.8 95 1446 200' N & 80' W of SE corner of pad 4' BFG 1 6 120.2 28.8 31.5 91.4 95 1447 200' N & 80' W of SE corner of pad 3' BFG 1 6 120.2 29.0 31.8 91.2 95 1448 200' N & 80' W of SE corner of pad 2' BFG 1 6 120.4 28.8 31.4 91.6 95 1449 200' N & 80' W of SE corner of pad 1' BFG 1 6 120.3 28.6 31.2 91.7 95 1450 200' N & 130' W of SE corner of pad 5' BFG 1 6 120.5 28.9 31.5 91.6 95 1451 200' N & 130' W of SE corner of pad 4' BFG 1 6 120.3 28.5 31.1 91.8 95 1452 200' N & 130' W of SE corner of pad 3' BFG 1 6 120.5 28.8 31.4 91.7 95 1453 200' N & 130' W of SE corner of pad 2' BFG 1 6 120.1 28.6 31.3 91.5 95 1454 200' N & 130' W of SE corner of pad 1' BFG 1 6 120.9 29.0 31.6 91.9 96 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0032 06/17/14 06/24/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad A 1455 50' N & 20' W of SE corner of pad 10' BFG 1 6 120.6 29.1 31.8 91.5 95 1456 50' N & 20' W of SE corner of pad 9' BFG 1 6 120.6 28.9 31.5 91.7 95 1457 50' N & 20' W of SE corner of pad 8' BFG 1 6 120.0 28.6 31.3 91.4 95 1458 50' N & 20' W of SE corner of pad 7' BFG 1 6 120.1 28.9 31.7 91.2 95 1459 50' N & 20' W of SE corner of pad 6' BFG 1 6 120.3 28.8 31.5 91.5 95 1460 50' N & 80' W of SE corner of pad 10' BFG 1 6 119.9 28.8 31.6 91.1 95 1461 50' N & 80' W of SE corner of pad 9' BFG 1 6 120.0 28.7 31.4 91.3 95 1462 50' N & 80' W of SE corner of pad 8' BFG 1 6 120.4 28.6 31.2 91.8 95 1463 50' N & 80' W of SE corner of pad 7' BFG 1 6 120.3 28.8 31.5 91.5 95 1464 50' N & 80' W of SE corner of pad 6' BFG 1 6 120.4 28.7 31.3 91.7 95 1465 50' N & 130' W of SE corner of pad 10' BFG 1 6 120.3 28.9 31.6 91.4 95 1466 50' N & 130' W of SE corner of pad 9' BFG 1 6 120.3 28.5 31.1 91.8 95 1467 50' N & 130' W of SE corner of pad 8' BFG 1 6 120.4 28.5 31.0 91.9 96 1468 50' N & 130' W of SE corner of pad 7' BFG 1 6 120.5 28.9 31.5 91.6 95 1469 50' N & 130' W of SE corner of pad 6' BFG 1 6 120.5 28.6 31.1 91.9 96 Bldg. Pad B 1470 230' N & 20' W of SE corner of pad 10' BFG 1 6 120.9 29.1 31.7 91.8 95 1471 230' N & 20' W of SE corner of pad 9' BFG 1 6 120.2 28.8 31.5 91.4 95 1472 230' N & 20' W of SE corner of pad 8' BFG 1 6 120.4 28.7 31.3 91.7 95 1473 230' N & 20' W of SE corner of pad 7' BFG 1 6 120.4 28.9 31.6 91.5 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0032 06/17/14 06/24/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1474 230' N & 20' W of SE corner of pad 6' BFG 1 6 119.8 28.5 31.2 91.3 95 1475 230' N & 80' W of SE corner of pad 10' BFG 1 6 120.5 29.1 31.8 91.4 95 1476 230' N & 80' W of SE corner of pad 9' BFG 1 6 120.7 29.0 31.6 91.7 95 1477 230' N & 80' W of SE corner of pad 8' BFG 1 6 120.1 28.6 31.3 91.5 95 1478 230' N & 80' W of SE corner of pad 7' BFG 1 6 120.7 28.9 31.5 91.8 95 1479 230' N & 80' W of SE corner of pad 6' BFG 1 6 120.8 29.0 31.6 91.8 95 1480 230' N & 130' W of SE corner of pad 10' BFG 1 6 120.6 29.1 31.8 91.5 95 1481 230' N & 130' W of SE corner of pad 9' BFG 1 6 120.2 28.9 31.6 91.3 95 1482 230' N & 130' W of SE corner of pad 8' BFG 1 6 120.4 28.7 31.3 91.7 95 1483 230' N & 130' W of SE corner of pad 7' BFG 1 6 119.8 28.4 31.1 91.4 95 1484 230' N & 130' W of SE corner of pad 6' BFG 1 6 120.8 28.9 31.4 91.9 96 Bldg. Pad A 1485 50' N & 30' W of SE corner of pad 5' BFG 1 6 120.4 28.7 31.3 91.7 95 1486 50' N & 30' W of SE corner of pad 4' BFG 1 6 120.0 28.5 31.1 91.5 95 1487 50' N & 30' W of SE corner of pad 3' BFG 1 6 120.0 28.7 31.4 91.3 95 1488 50' N & 30' W of SE corner of pad 2' BFG 1 6 120.2 28.6 31.2 91.6 95 1489 50' N & 30' W of SE corner of pad 1' BFG 1 6 120.8 29.0 31.6 91.8 95 1490 50' N & 80' W of SE corner of pad 5' BFG 1 6 119.7 28.2 30.8 91.5 95 1491 50' N & 80' W of SE corner of pad 4' BFG 1 6 119.7 28.5 31.2 91.2 95 1492 50' N & 80' W of SE corner of pad 3' BFG 1 6 119.3 28.2 31.0 91.1 95 1493 50' N & 80' W of SE corner of pad 2' BFG 1 6 120.4 28.8 31.4 91.6 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 4 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0032 06/17/14 06/24/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1494 50' N & 80' W of SE corner of pad 1' BFG 1 6 119.7 28.4 31.1 91.3 95 1495 50' N & 130' W of SE corner of pad 5' BFG 1 6 120.8 29.0 31.6 91.8 95 1496 50' N & 130' W of SE corner of pad 4' BFG 1 6 120.1 28.6 31.3 91.5 95 1497 50' N & 130' W of SE corner of pad 3' BFG 1 6 119.7 28.4 31.1 91.3 95 1498 50' N & 130' W of SE corner of pad 2' BFG 1 6 120.6 28.9 31.5 91.7 95 1499 50' N & 130' W of SE corner of pad 1' BFG 1 6 120.4 29.0 31.7 91.4 95 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 5 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0033 06/18/14 06/24/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad D 1500 740' N & 20' W of SE corner of pad 10' BFG 1 6 120.6 28.8 31.4 91.8 95 1501 740' N & 20' W of SE corner of pad 9' BFG 1 6 120.1 28.5 31.1 91.6 95 1502 740' N & 20' W of SE corner of pad 8' BFG 1 6 121.0 29.1 31.7 91.9 96 1503 740' N & 20' W of SE corner of pad 7' BFG 1 6 120.3 28.8 31.5 91.5 95 1504 740' N & 20' W of SE corner of pad 6' BFG 1 6 120.4 28.7 31.3 91.7 95 1505 740' N & 100' W of SE corner of pad 10' BFG 1 6 120.4 29.0 31.7 91.4 95 1506 740' N & 100' W of SE corner of pad 9' BFG 1 6 119.8 28.6 31.4 91.2 95 1507 740' N & 100' W of SE corner of pad 8' BFG 1 6 120.3 28.7 31.3 91.6 95 1508 740' N & 100' W of SE corner of pad 7' BFG 1 6 120.3 28.5 31.1 91.8 95 1509 740' N & 100' W of SE corner of pad 6' BFG 1 6 120.5 28.9 31.5 91.6 95 1510 740' N & 80' W of SE corner of pad 10' BFG 1 6 120.0 28.5 31.2 91.5 95 1511 740' N & 80' W of SE corner of pad 9' BFG 1 6 120.3 28.5 31.0 91.8 95 1512 740' N & 80' W of SE corner of pad 8' BFG 1 6 120.0 28.8 31.6 91.2 95 1513 740' N & 80' W of SE corner of pad 7' BFG 1 6 120.1 28.6 31.3 91.5 95 1514 740' N & 80' W of SE corner of pad 6' BFG 1 6 120.2 28.9 31.7 91.3 95 Bldg. Pad B The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0033 06/18/14 06/24/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1515 230' N & 20' W of SE corner of pad 5' BFG 1 6 120.4 28.7 31.3 91.7 95 1516 230' N & 20' W of SE corner of pad 4' BFG 1 6 120.3 29.0 31.8 91.3 95 1517 230' N & 20' W of SE corner of pad 3' BFG 1 6 120.3 28.8 31.5 91.5 95 1518 230' N & 20' W of SE corner of pad 2' BFG 1 6 119.5 28.4 31.2 91.1 95 1519 230' N & 20' W of SE corner of pad 1' BFG 1 6 120.0 28.7 31.4 91.3 95 1520 230' N & 80' W of SE corner of pad 5' BFG 1 6 120.9 29.1 31.7 91.8 95 1521 230' N & 80' W of SE corner of pad 4' BFG 1 6 120.3 28.8 31.5 91.5 95 1522 230' N & 80' W of SE corner of pad 3' BFG 1 6 119.7 28.5 31.2 91.2 95 1523 230' N & 80' W of SE corner of pad 2' BFG 1 6 120.8 29.0 31.6 91.8 95 1524 230' N & 80' W of SE corner of pad 1' BFG 1 6 120.5 28.9 31.5 91.6 95 1525 230' N & 130' W of SE corner of pad 5' BFG 1 6 121.1 29.2 31.8 91.9 96 1526 230' N & 130' W of SE corner of pad 4' BFG 1 6 120.7 29.0 31.6 91.7 95 1527 230' N & 130' W of SE corner of pad 3' BFG 1 6 120.2 28.7 31.4 91.5 95 1528 230' N & 130' W of SE corner of pad 2' BFG 1 6 120.1 28.5 31.1 91.6 95 1529 230' N & 130' W of SE corner of pad 1' BFG 1 6 120.5 28.7 31.3 91.8 95 1530 260' N & 20' W of SE corner of pad 10' BFG 1 6 120.4 28.6 31.2 91.8 95 1531 260' N & 20' W of SE corner of pad 9' BFG 1 6 119.8 28.6 31.4 91.2 95 1532 260' N & 20' W of SE corner of pad 8' BFG 1 6 120.7 29.0 31.6 91.7 95 1533 260' N & 20' W of SE corner of pad 7' BFG 1 6 120.1 28.6 31.3 91.5 95 1534 260' N & 20' W of SE corner of pad 6' BFG 1 6 120.1 28.8 31.5 91.3 95 1535 260' N & 80' W of SE corner of pad 10' BFG 1 6 120.5 28.6 31.1 91.9 96 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0033 06/18/14 06/24/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1536 260' N & 80' W of SE corner of pad 9' BFG 1 6 120.5 28.8 31.4 91.7 95 1537 260' N & 80' W of SE corner of pad 8' BFG 1 6 120.2 28.8 31.5 91.4 95 1538 260' N & 80' W of SE corner of pad 7' BFG 1 6 120.6 29.0 31.7 91.6 95 1539 260' N & 80' W of SE corner of pad 6' BFG 1 6 120.4 28.6 31.2 91.8 95 1540 260' N & 130' W of SE corner of pad 10' BFG 1 6 119.7 28.7 31.5 91.0 95 1541 260' N & 130' W of SE corner of pad 9' BFG 1 6 119.7 28.5 31.3 91.2 95 1542 260' N & 130' W of SE corner of pad 8' BFG 1 6 120.4 28.9 31.6 91.5 95 1543 260' N & 130' W of SE corner of pad 7' BFG 1 6 120.3 29.0 31.8 91.3 95 1544 260' N & 130' W of SE corner of pad 6' BFG 1 6 120.4 28.8 31.4 91.6 95 1545 260' N & 20' W of SE corner of pad 5' BFG 1 6 119.9 28.9 31.8 91.0 95 1546 260' N & 20' W of SE corner of pad 4' BFG 1 6 120.2 28.9 31.6 91.3 95 1547 260' N & 20' W of SE corner of pad 3' BFG 1 6 120.2 29.0 31.8 91.2 95 1548 260' N & 20' W of SE corner of pad 2' BFG 1 6 120.4 28.9 31.6 91.5 95 1549 260' N & 20' W of SE corner of pad 1' BFG 1 6 120.5 28.8 31.4 91.7 95 1550 260' N & 80' W of SE corner of pad 5' BFG 1 6 120.4 29.0 31.7 91.4 95 1551 260' N & 80' W of SE corner of pad 4' BFG 1 6 120.5 28.7 31.3 91.8 95 1552 260' N & 80' W of SE corner of pad 3' BFG 1 6 120.5 28.9 31.5 91.6 95 1553 260' N & 80' W of SE corner of pad 2' BFG 1 6 120.5 29.1 31.8 91.4 95 1554 260' N & 80' W of SE corner of pad 1' BFG 1 6 120.0 28.8 31.6 91.2 95 1555 260' N & 130' W of SE corner of pad 5' BFG 1 6 119.4 28.4 31.2 91.0 95 1556 260' N & 130' W of SE corner of pad 4' BFG 1 6 120.4 28.9 31.6 91.5 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0033 06/18/14 06/24/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1557 260' N & 130' W of SE corner of pad 3' BFG 1 6 120.1 28.8 31.5 91.3 95 1558 260' N & 130' W of SE corner of pad 2' BFG 1 6 120.3 28.7 31.3 91.6 95 1559 260' N & 130' W of SE corner of pad 1' BFG 1 6 120.1 28.9 31.7 91.2 95 1560 290' N & 20' W of SE corner of pad 10' BFG 1 6 119.5 28.4 31.2 91.1 95 1561 290' N & 20' W of SE corner of pad 9' BFG 1 6 119.6 28.2 30.9 91.4 95 1562 290' N & 20' W of SE corner of pad 8' BFG 1 6 120.4 28.8 31.4 91.6 95 1563 290' N & 20' W of SE corner of pad 7' BFG 1 6 119.9 28.6 31.3 91.3 95 1564 290' N & 20' W of SE corner of pad 6' BFG 1 6 120.2 28.5 31.1 91.7 95 1565 290' N & 80' W of SE corner of pad 10' BFG 1 6 119.9 28.7 31.5 91.2 95 1566 290' N & 80' W of SE corner of pad 9' BFG 1 6 119.5 28.5 31.3 91.0 95 1567 290' N & 80' W of SE corner of pad 8' BFG 1 6 120.4 28.9 31.6 91.5 95 1568 290' N & 80' W of SE corner of pad 7' BFG 1 6 120.3 29.0 31.8 91.3 95 1569 290' N & 80' W of SE corner of pad 6' BFG 1 6 120.4 28.8 31.4 91.6 95 1570 290' N & 130' W of SE corner of pad 10' BFG 1 6 119.9 28.5 31.2 91.4 95 1571 290' N & 130' W of SE corner of pad 9' BFG 1 6 120.7 29.0 31.6 91.7 95 1572 290' N & 130' W of SE corner of pad 8' BFG 1 6 120.1 29.0 31.8 91.1 95 1573 290' N & 130' W of SE corner of pad 7' BFG 1 6 120.2 28.9 31.6 91.3 95 1574 290' N & 130' W of SE corner of pad 6' BFG 1 6 119.6 28.6 31.4 91.0 95 Bldg. Pad A 1575 80' N & 20' W of SE corner of pad 10' BFG 1 6 120.5 29.0 31.7 91.5 95 1576 80' N & 20' W of SE corner of pad 9' BFG 1 6 119.9 28.7 31.5 91.2 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 4 of 6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0033 06/18/14 06/24/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1577 80' N & 20' W of SE corner of pad 8' BFG 1 6 120.7 29.1 31.8 91.6 95 1578 80' N & 20' W of SE corner of pad 7' BFG 1 6 120.3 28.9 31.6 91.4 95 1579 80' N & 20' W of SE corner of pad 6' BFG 1 6 119.7 28.5 31.2 91.2 95 1580 80' N & 80' W of SE corner of pad 10' BFG 1 6 119.6 28.6 31.4 91.0 95 1581 80' N & 80' W of SE corner of pad 9' BFG 1 6 120.5 29.1 31.8 91.4 95 1582 80' N & 80' W of SE corner of pad 8' BFG 1 6 120.7 29.0 31.6 91.7 95 1583 80' N & 80' W of SE corner of pad 7' BFG 1 6 120.1 28.8 31.5 91.3 95 1584 80' N & 80' W of SE corner of pad 6' BFG 1 6 120.4 29.0 31.7 91.4 95 1585 80' N & 130' W of SE corner of pad 10' BFG 1 6 119.8 28.7 31.5 91.1 95 1586 80' N & 130' W of SE corner of pad 9' BFG 1 6 120.6 29.2 31.9 91.4 95 1587 80' N & 130' W of SE corner of pad 8' BFG 1 6 120.2 28.7 31.4 91.5 95 1588 80' N & 130' W of SE corner of pad 7' BFG 1 6 120.3 28.6 31.2 91.7 95 1589 80' N & 130' W of SE corner of pad 6' BFG 1 6 120.2 28.9 31.6 91.3 95 1590 290' N & 20' W of SE corner of pad 5' BFG 1 6 120.4 28.5 31.0 91.9 96 1591 290' N & 20' W of SE corner of pad 4' BFG 1 6 120.5 28.8 31.4 91.7 95 1592 290' N & 20' W of SE corner of pad 3' BFG 1 6 119.4 28.4 31.2 91.0 95 1593 290' N & 20' W of SE corner of pad 2' BFG 1 6 120.8 29.0 31.6 91.8 95 1594 290' N & 20' W of SE corner of pad 1' BFG 1 6 120.1 28.5 31.1 91.6 95 1595 290' N & 80' W of SE corner of pad 5' BFG 1 6 120.4 28.5 31.0 91.9 96 1596 290' N & 80' W of SE corner of pad 4' BFG 1 6 120.4 28.8 31.4 91.6 95 1597 290' N & 80' W of SE corner of pad 3' BFG 1 6 120.2 28.9 31.7 91.3 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 5 of 6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0033 06/18/14 06/24/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1598 290' N & 80' W of SE corner of pad 2' BFG 1 6 120.4 28.9 31.6 91.5 95 1599 290' N & 80' W of SE corner of pad 1' BFG 1 6 120.4 28.7 31.3 91.7 95 1600 290' N & 130' W of SE corner of pad 5' BFG 1 6 120.2 28.7 31.4 91.5 95 1601 290' N & 130' W of SE corner of pad 4' BFG 1 6 120.3 28.5 31.1 91.8 95 1602 290' N & 130' W of SE corner of pad 3' BFG 1 6 120.5 28.9 31.5 91.6 95 1603 290' N & 130' W of SE corner of pad 2' BFG 1 6 120.7 28.8 31.3 91.9 96 1604 290' N & 130' W of SE corner of pad 1' BFG 1 6 120.1 28.4 31.0 91.7 95 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 6 of 6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0034 06/19/14 06/26/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad B 1660 320' N & 20' W of SE corner of pad 10' BFG 1 6 119.6 28.7 31.6 90.9 94 1661 320' N & 20' W of SE corner of pad 9' BFG 1 6 120.0 28.6 31.3 91.4 95 1662 320' N & 20' W of SE corner of pad 8' BFG 1 6 119.8 28.6 31.4 91.2 95 1663 320' N & 20' W of SE corner of pad 7' BFG 1 6 120.6 29.0 31.7 91.6 95 1664 320' N & 20' W of SE corner of pad 6' BFG 1 6 120.1 28.8 31.5 91.3 95 1665 320' N & 80' W of SE corner of pad 10' BFG 1 6 120.0 28.9 31.7 91.1 95 1666 320' N & 80' W of SE corner of pad 9' BFG 1 6 120.2 28.7 31.4 91.5 95 1667 320' N & 80' W of SE corner of pad 8' BFG 1 6 120.9 29.2 31.8 91.7 95 1668 320' N & 80' W of SE corner of pad 7' BFG 1 6 120.1 28.8 31.5 91.3 95 1669 320' N & 80' W of SE corner of pad 6' BFG 1 6 120.4 28.9 31.6 91.5 95 1670 320' N & 130' W of SE corner of pad 10' BFG 1 6 120.2 29.0 31.8 91.2 95 1671 320' N & 130' W of SE corner of pad 9' BFG 1 6 120.4 28.8 31.4 91.6 95 1672 320' N & 130' W of SE corner of pad 8' BFG 1 6 120.2 29.0 31.8 91.2 95 1673 320' N & 130' W of SE corner of pad 7' BFG 1 6 120.5 28.9 31.5 91.6 95 1674 320' N & 130' W of SE corner of pad 6' BFG 1 6 120.4 28.7 31.3 91.7 95 Bldg. Pad A The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0034 06/19/14 06/26/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1675 80' N & 20' W of SE corner of pad 5' BFG 1 6 120.0 28.9 31.7 91.1 95 1676 80' N & 20' W of SE corner of pad 4' BFG 1 6 120.5 28.9 31.5 91.6 95 1677 80' N & 20' W of SE corner of pad 3' BFG 1 6 119.7 28.5 31.3 91.2 95 1678 80' N & 20' W of SE corner of pad 2' BFG 1 6 119.8 28.8 31.6 91.0 95 1679 80' N & 20' W of SE corner of pad 1' BFG 1 6 120.2 28.7 31.4 91.5 95 1680 80' N & 80' W of SE corner of pad 5' BFG 1 6 120.4 28.7 31.3 91.7 95 1681 80' N & 80' W of SE corner of pad 4' BFG 1 6 119.9 28.4 31.0 91.5 95 1682 80' N & 80' W of SE corner of pad 3' BFG 1 6 120.0 28.7 31.4 91.3 95 1683 80' N & 80' W of SE corner of pad 2' BFG 1 6 119.5 28.4 31.2 91.1 95 1684 80' N & 80' W of SE corner of pad 1' BFG 1 6 120.7 28.9 31.5 91.8 95 1685 80' N & 130' W of SE corner of pad 5' BFG 1 6 120.4 28.5 31.0 91.9 96 1686 80' N & 130' W of SE corner of pad 4' BFG 1 6 120.4 28.8 31.4 91.6 95 1687 80' N & 130' W of SE corner of pad 3' BFG 1 6 120.3 28.6 31.2 91.7 95 1688 80' N & 130' W of SE corner of pad 2' BFG 1 6 120.2 28.8 31.5 91.4 95 1689 80' N & 130' W of SE corner of pad 1' BFG 1 6 120.2 28.9 31.7 91.3 95 Bldg. Pad B 1690 320' N & 20' W of SE corner of pad 5' BFG 1 6 120.7 29.0 31.6 91.7 95 1691 320' N & 20' W of SE corner of pad 4' BFG 1 6 120.6 28.7 31.2 91.9 96 1692 320' N & 20' W of SE corner of pad 3' BFG 1 6 120.6 29.0 31.7 91.6 95 1693 320' N & 20' W of SE corner of pad 2' BFG 1 6 119.9 28.7 31.5 91.2 95 1694 320' N & 20' W of SE corner of pad 1' BFG 1 6 120.5 28.7 31.3 91.8 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0034 06/19/14 06/26/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1695 320' N & 80' W of SE corner of pad 5' BFG 1 6 120.0 28.8 31.6 91.2 95 1696 320' N & 80' W of SE corner of pad 4' BFG 1 6 120.2 28.6 31.2 91.6 95 1697 320' N & 80' W of SE corner of pad 3' BFG 1 6 119.8 28.8 31.7 91.0 95 1698 320' N & 80' W of SE corner of pad 2' BFG 1 6 120.2 28.8 31.5 91.4 95 1699 320' N & 80' W of SE corner of pad 1' BFG 1 6 120.2 29.0 31.8 91.2 95 1700 320' N & 130' W of SE corner of pad 5' BFG 1 6 120.0 28.9 31.7 91.1 95 1701 320' N & 130' W of SE corner of pad 4' BFG 1 6 120.4 28.8 31.4 91.6 95 1702 320' N & 130' W of SE corner of pad 3' BFG 1 6 120.2 28.9 31.6 91.3 95 1703 320' N & 130' W of SE corner of pad 2' BFG 1 6 120.3 28.6 31.2 91.7 95 1704 320' N & 130' W of SE corner of pad 1' BFG 1 6 120.2 28.8 31.5 91.4 95 Bldg. Pad A 1705 110' N & 20' W of SE corner of pad 10' BFG 1 6 120.1 28.3 30.8 91.8 95 1706 110' N & 20' W of SE corner of pad 9' BFG 1 6 120.2 28.6 31.2 91.6 95 1707 110' N & 20' W of SE corner of pad 8' BFG 1 6 120.1 28.7 31.4 91.4 95 1708 110' N & 20' W of SE corner of pad 7' BFG 1 6 120.2 28.5 31.1 91.7 95 1709 110' N & 20' W of SE corner of pad 6' BFG 1 6 120.1 28.6 31.3 91.5 95 1710 110' N & 80' W of SE corner of pad 10' BFG 1 6 120.5 28.6 31.1 91.9 96 1711 110' N & 80' W of SE corner of pad 9' BFG 1 6 120.5 28.8 31.4 91.7 95 1712 110' N & 80' W of SE corner of pad 8' BFG 1 6 120.0 28.5 31.2 91.5 95 1713 110' N & 80' W of SE corner of pad 7' BFG 1 6 120.1 28.8 31.5 91.3 95 1714 110' N & 80' W of SE corner of pad 6' BFG 1 6 120.0 28.8 31.6 91.2 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0034 06/19/14 06/26/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1715 110' N & 130' W of SE corner of pad 10' BFG 1 6 120.8 28.9 31.4 91.9 96 1716 110' N & 130' W of SE corner of pad 9' BFG 1 6 120.1 28.5 31.1 91.6 95 1717 110' N & 30' W of SE corner of pad 8' BFG 1 6 120.2 28.7 31.4 91.5 95 1718 110' N & 30' W of SE corner of pad 7' BFG 1 6 120.4 28.6 31.2 91.8 95 1719 110' N & 30' W of SE corner of pad 6' BFG 1 6 120.2 28.9 31.6 91.3 95 1720 110' N & 20' W of SE corner of pad 5' BFG 1 6 120.5 28.6 31.1 91.9 96 1721 110' N & 20' W of SE corner of pad 4' BFG 1 6 120.4 28.7 31.3 91.7 95 1722 110' N & 20' W of SE corner of pad 3' BFG 1 6 120.2 28.8 31.5 91.4 95 1723 110' N & 20' W of SE corner of pad 2' BFG 1 6 120.2 28.6 31.2 91.6 95 1724 110' N & 20' W of SE corner of pad 1' BFG 1 6 120.2 28.9 31.7 91.3 95 1725 110' N & 80' W of SE corner of pad 5' BFG 1 6 120.4 28.9 31.6 91.5 95 1726 110' N & 80' W of SE corner of pad 4' BFG 1 6 119.6 28.5 31.3 91.1 95 1727 110' N & 80' W of SE corner of pad 3' BFG 1 6 120.5 28.9 31.5 91.6 95 1728 110' N & 80' W of SE corner of pad 2' BFG 1 6 120.2 28.9 31.7 91.3 95 1729 110' N & 80' W of SE corner of pad 1' BFG 1 6 119.6 28.6 31.4 91.0 95 1730 110' N & 130' W of SE corner of pad 5' BFG 1 6 120.3 28.9 31.6 91.4 95 1731 110' N & 130' W of SE corner of pad 4' BFG 1 6 120.5 28.7 31.3 91.8 95 1732 110' N & 130' W of SE corner of pad 3' BFG 1 6 120.5 28.9 31.5 91.6 95 1733 110' N & 130' W of SE corner of pad 2' BFG 1 6 120.6 28.7 31.2 91.9 96 1734 110' N & 130' W of SE corner of pad 1' BFG 1 6 120.5 29.0 31.7 91.5 95 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 4 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0034 06/19/14 06/26/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 5 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0035 06/20/14 06/27/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad D 1735 740' N & 20' of SE corner of pad 5' BFG 1 6 120.0 28.3 30.9 91.7 95 1736 740' N & 20' of SE corner of pad 4' BFG 1 6 120.0 28.7 31.4 91.3 95 1737 740' N & 20' of SE corner of pad 3' BFG 1 6 120.0 28.5 31.2 91.5 95 1738 740' N & 20' of SE corner of pad 2' BFG 1 6 120.7 28.9 31.5 91.8 95 1739 740' N & 20' of SE corner of pad 1' BFG 1 6 120.0 28.6 31.3 91.4 95 1740 740' N & 100' of SE corner of pad 5' BFG 1 6 120.4 28.6 31.2 91.8 95 1741 740' N & 100' of SE corner of pad 4' BFG 1 6 120.4 28.9 31.6 91.5 95 1742 740' N & 100' of SE corner of pad 3' BFG 1 6 120.4 28.7 31.3 91.7 95 1743 740' N & 100' of SE corner of pad 2' BFG 1 6 120.5 28.6 31.1 91.9 96 1744 740' N & 100' of SE corner of pad 1' BFG 1 6 120.2 28.8 31.5 91.4 95 1745 740' N & 180' of SE corner of pad 5' BFG 1 6 120.4 28.7 31.3 91.7 95 1746 740' N & 180' of SE corner of pad 4' BFG 1 6 120.4 28.9 31.6 91.5 95 1747 740' N & 180' of SE corner of pad 3' BFG 1 6 120.4 28.9 31.6 91.5 95 1748 740' N & 180' of SE corner of pad 2' BFG 1 6 120.4 28.7 31.3 91.7 95 1749 740' N & 180' of SE corner of pad 1' BFG 1 6 120.4 28.8 31.4 91.6 95 Bldg. Pad A The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0035 06/20/14 06/27/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1750 140' N & 20' W of SE corner of pad 10' BFG 1 6 120.5 28.6 31.1 91.9 96 1751 140' N & 20' W of SE corner of pad 9' BFG 1 6 120.5 28.9 31.5 91.6 95 1752 140' N & 20' W of SE corner of pad 8' BFG 1 6 120.4 28.7 31.3 91.7 95 1753 140' N & 20' W of SE corner of pad 7' BFG 1 6 120.4 29.0 31.7 91.4 95 1754 140' N & 20' W of SE corner of pad 6' BFG 1 6 120.6 28.8 31.4 91.8 95 1755 140' N & 80' W of SE corner of pad 10' BFG 1 6 120.3 28.6 31.2 91.7 95 1756 140' N & 80' W of SE corner of pad 9' BFG 1 6 120.4 28.9 31.6 91.5 95 1757 140' N & 80' W of SE corner of pad 8' BFG 1 6 120.0 28.7 31.4 91.3 95 1758 140' N & 80' W of SE corner of pad 7' BFG 1 6 120.3 28.7 31.3 91.6 95 1759 140' N & 80' W of SE corner of pad 6' BFG 1 6 120.2 29.0 31.8 91.2 95 1760 140' N & 130' W of SE corner of pad 10' BFG 1 6 120.6 28.9 31.5 91.7 95 1761 140' N & 130' W of SE corner of pad 9' BFG 1 6 120.5 29.0 31.7 91.5 95 1762 140' N & 130' W of SE corner of pad 8' BFG 1 6 120.0 28.7 31.4 91.3 95 1763 140' N & 130' W of SE corner of pad 7' BFG 1 6 120.1 28.5 31.1 91.6 95 1764 140' N & 130' W of SE corner of pad 6' BFG 1 6 120.2 28.8 31.5 91.4 95 1765 140' N & 20' W of SE corner of pad 5' BFG 1 6 120.3 28.6 31.2 91.7 95 1766 140' N & 20' W of SE corner of pad 4' BFG 1 6 120.5 29.0 31.7 91.5 95 1767 140' N & 20' W of SE corner of pad 3' BFG 1 6 120.5 28.9 31.5 91.6 95 1768 140' N & 20' W of SE corner of pad 2' BFG 1 6 120.5 28.7 31.3 91.8 95 1769 140' N & 20' W of SE corner of pad 1' BFG 1 6 120.2 28.9 31.6 91.3 95 1770 140' N & 80' W of SE corner of pad 5' BFG 1 6 120.7 28.6 31.0 92.1 96 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0035 06/20/14 06/27/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1771 140' N & 80' W of SE corner of pad 4' BFG 1 6 120.6 28.8 31.4 91.8 95 1772 140' N & 80' W of SE corner of pad 3' BFG 1 6 120.3 28.7 31.3 91.6 95 1773 140' N & 80' W of SE corner of pad 2' BFG 1 6 120.2 28.9 31.6 91.3 95 1774 140' N & 80' W of SE corner of pad 1' BFG 1 6 120.3 28.6 31.2 91.7 95 1775 140' N & 130' W of SE corner of pad 5' BFG 1 6 120.2 28.8 31.5 91.4 95 1776 140' N & 130' W of SE corner of pad 4' BFG 1 6 120.4 28.6 31.2 91.8 95 1777 140' N & 130' W of SE corner of pad 3' BFG 1 6 120.4 28.9 31.6 91.5 95 1778 140' N & 130' W of SE corner of pad 2' BFG 1 6 120.4 28.7 31.3 91.7 95 1779 140' N & 130' W of SE corner of pad 1' BFG 1 6 120.5 28.6 31.1 91.9 96 1780 170' N & 20' W of SE corner of pad 10' BFG 1 6 120.5 28.8 31.4 91.7 95 1781 170' N & 20' W of SE corner of pad 9' BFG 1 6 120.6 28.7 31.2 91.9 96 1782 170' N & 20' W of SE corner of pad 8' BFG 1 6 120.0 28.4 31.0 91.6 95 1783 170' N & 20' W of SE corner of pad 7' BFG 1 6 120.7 28.9 31.5 91.8 95 1784 170' N & 20' W of SE corner of pad 6' BFG 1 6 120.1 28.6 31.3 91.5 95 1785 170' N & 80' W of SE corner of pad 10' BFG 1 6 120.3 28.5 31.1 91.8 95 1786 170' N & 80' W of SE corner of pad 9' BFG 1 6 120.4 28.9 31.6 91.5 95 1787 170' N & 80' W of SE corner of pad 8' BFG 1 6 120.5 28.8 31.4 91.7 95 1788 170' N & 80' W of SE corner of pad 7' BFG 1 6 120.1 28.9 31.7 91.2 95 1789 170' N & 80' W of SE corner of pad 6' BFG 1 6 120.4 28.8 31.4 91.6 95 1790 170' N & 130' W of SE corner of pad 10' BFG 1 6 120.4 28.6 31.2 91.8 95 1791 170' N & 130' W of SE corner of pad 9' BFG 1 6 120.3 28.8 31.5 91.5 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0035 06/20/14 06/27/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1792 170' N & 130' W of SE corner of pad 8' BFG 1 6 120.2 29.0 31.8 91.2 95 1793 170' N & 130' W of SE corner of pad 7' BFG 1 6 120.4 28.9 31.6 91.5 95 1794 170' N & 130' W of SE corner of pad 6' BFG 1 6 120.4 28.7 31.3 91.7 95 1795 170' N & 20' W of SE corner of pad 5' BFG 1 6 120.3 28.9 31.6 91.4 95 1796 170' N & 20' W of SE corner of pad 4' BFG 1 6 120.3 28.6 31.2 91.7 95 1797 170' N & 20' W of SE corner of pad 3' BFG 1 6 120.0 28.7 31.4 91.3 95 1798 170' N & 20' W of SE corner of pad 2' BFG 1 6 120.4 29.0 31.7 91.4 95 1799 170' N & 20' W of SE corner of pad 1' BFG 1 6 120.7 28.9 31.5 91.8 95 1800 170' N & 80' W of SE corner of pad 5' BFG 1 6 120.4 28.9 31.6 91.5 95 1801 170' N & 80' W of SE corner of pad 4' BFG 1 6 120.4 29.1 31.9 91.3 95 1802 170' N & 80' W of SE corner of pad 3' BFG 1 6 120.5 28.8 31.4 91.7 95 1803 170' N & 80' W of SE corner of pad 2' BFG 1 6 120.5 29.0 31.7 91.5 95 1804 170' N & 80' W of SE corner of pad 1' BFG 1 6 120.8 28.9 31.5 91.9 96 1805 170' N & 130' W of SE corner of pad 5' BFG 1 67 120.3 28.5 31.1 91.8 95 1806 170' N & 130' W of SE corner of pad 4' BFG 1 6 120.4 28.8 31.4 91.6 95 1807 170' N & 130' W of SE corner of pad 3' BFG 1 6 120.6 28.7 31.2 91.9 96 1808 170' N & 130' W of SE corner of pad 2' BFG 1 6 120.2 28.8 31.5 91.4 95 1809 170' N & 130' W of SE corner of pad 1' BFG 1 6 120.4 28.7 31.3 91.7 95 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 4 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0035 06/20/14 06/27/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 5 of 5 CR0006, 10-16-13, Rev.7 Page 1 of 1 LABORATORY COMPACTION CHARACTERISTICS OF SOIL REPORT Report Number:94141126.0036 Service Date: 06/20/14 8901 Carpenter Frwy., Suite 100 Report Date:06/24/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number 94141126 Material Information Sample Information Source of Material:Native Sample Date:06/17/14 Proposed Use:Common fill Sampled By:Armando Rendon Sample Location:On site @ building pad "C" Sample Description:Lime treated dark and light brown clay Laboratory Test Data Result Specifications Test Procedure:ASTM D698 Liquid Limit:45 Test Method:Method A Plastic Limit:36 Sample Preparation:Wet Plasticity Index:9 Rammer Type:Mechanical In-Place Moisture (%): Maximum Dry Unit Weight (pcf):86.8 Optimum Water Content (%):30.2 USCS: Comments: Services: Terracon Rep.: Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By:_______________________________ James D. Baze Project Manager Test Methods:ASTM D698, ASTM D1140, ASTM D4318 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Zero Ai r Vo i d s Curve fo r Ass umed Specific G rav i ty 2.70 383736353433323130292827262524 82 83 84 85 86 87 88 89 Water Content (%) D r y U n i t W e i g h t (p c f ) FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0037 06/21/14 06/27/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 95-2/+2286.830.294141126.0036 Lime treated dark and light brown clay ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad A 1810 200' N & 20' W of SE corner of pad 10' BFG 1 6 119.7 28.1 30.7 91.6 95 1811 200' N & 20' W of SE corner of pad 9' BFG 1 6 120.3 28.4 30.9 91.9 96 1812 200' N & 20' W of SE corner of pad 8' BFG 1 6 119.9 28.6 31.3 91.3 95 1813 200' N & 20' W of SE corner of pad 7' BFG 1 6 119.9 28.4 31.0 91.5 95 1814 200' N & 20' W of SE corner of pad 6' BFG 1 6 119.7 28.5 31.2 91.2 95 1815 200' N & 80' W of SE corner of pad 10' BFG 1 6 120.2 28.5 31.1 91.7 95 1816 200' N & 80' W of SE corner of pad 9' BFG 1 6 120.3 28.8 31.5 91.5 95 1817 200' N & 80' W of SE corner of pad 8' BFG 1 6 120.2 29.0 31.8 91.2 95 1818 200' N & 80' W of SE corner of pad 7' BFG 1 6 120.3 28.9 31.6 91.4 95 1819 200' N & 80' W of SE corner of pad 6' BFG 1 6 120.2 28.6 31.2 91.6 95 1820 200' N & 130' W of SE corner of pad 10' BFG 1 6 119.5 28.3 31.0 91.2 95 1821 200' N & 130' W of SE corner of pad 9' BFG 1 6 120.2 28.7 31.4 91.5 95 1822 200' N & 130' W of SE corner of pad 8' BFG 1 6 120.5 28.7 31.3 91.8 95 1823 200' N & 130' W of SE corner of pad 7' BFG 1 6 120.3 28.9 31.6 91.4 95 1824 200' N & 130' W of SE corner of pad 6' BFG 1 6 120.0 28.5 31.2 91.5 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0037 06/21/14 06/27/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad C 1825 20' N & 30' E of SW corner of pad Final 2 6 110.2 25.7 30.4 84.5 97 1826 100' N & 100' E of SW corner of pad Final 2 6 110.3 25.4 29.9 84.9 98 1827 200' N & 160' E of SW corner of pad Final 2 6 110.6 25.6 30.1 85.0 98 1828 300' N & 40' E of SW corner of pad Final 2 6 109.3 25.6 30.6 83.7 96 1829 400' N & 100' E of SW corner of pad Final 2 6 109.5 25.4 30.2 84.1 97 1830 460' N & 150' E of SW corner of pad Final 2 6 109.7 25.8 30.8 83.9 97 1831 400' N & 20' E of SW corner of pad Final 2 6 110.0 25.8 30.6 84.2 97 Bldg. Pad A 1832 200' N & 15' W of SE corner of pad 5' BFG 2 6 120.3 28.4 30.9 91.9 106 1833 200' N & 15' W of SE corner of pad 4' BFG 2 6 119.7 28.6 31.4 91.1 105 1834 200' N & 15' W of SE corner of pad 3' BFG 2 6 119.8 28.5 31.2 91.3 105 1835 200' N & 15' W of SE corner of pad 2' BFG 2 6 119.9 28.4 31.0 91.5 105 1836 200' N & 15' W of SE corner of pad 1' BFG 2 6 120.6 28.9 31.5 91.7 106 1837 200' N & 90' W of SE corner of pad 5' BFG 2 6 120.1 28.9 31.7 91.2 105 1838 200' N & 90' W of SE corner of pad 4' BFG 2 6 120.5 28.9 31.5 91.6 106 1839 200' N & 90' W of SE corner of pad 3' BFG 2 6 120.3 29.0 31.8 91.3 105 1840 200' N & 90' W of SE corner of pad 2' BFG 1 6 120.5 28.9 31.5 91.6 95 1841 200' N & 90' W of SE corner of pad 1' BFG 1 6 120.0 28.9 31.7 91.1 95 1842 200' N & 120' W of SE corner of pad 5' BFG 1 6 120.1 28.6 31.3 91.5 95 1843 200' N & 120' W of SE corner of pad 4' BFG 1 6 120.6 28.9 31.5 91.7 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0037 06/21/14 06/27/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1844 200' N & 120' W of SE corner of pad 3' BFG 1 6 119.9 28.9 31.8 91.0 95 1845 200' N & 120' W of SE corner of pad 2' BFG 1 6 120.8 29.0 31.6 91.8 95 1846 200' N & 120' W of SE corner of pad 1' BFG 1 6 120.0 28.5 31.2 91.5 95 Bldg. Pad C 1847 30' N & 120' E of SW corner of pad Final 2 6 111.1 26.9 32.0 84.2 97 1848 200' N & 50' E of SW corner of pad Final 2 6 112.2 27.1 31.8 85.1 98 1849 300' N & 150' E of SW corner of pad Final 2 6 110.9 26.6 31.6 84.3 97 1850 200' N & 100' E of SW corner of pad Final 2 6 110.8 26.1 30.8 84.7 98 1851 300' N & 100' E of SW corner of pad Final 2 6 109.9 26.1 31.2 83.8 97 1852 100' N & 150' E of SW corner of pad Final 2 6 110.1 25.8 30.6 84.3 97 1853 150' N & 60' E of SW corner of pad Final 2 6 110.1 25.6 30.3 84.5 97 1854 400' N & 100' E of SW corner of pad Final 2 6 109.6 25.9 31.0 83.7 96 Bldg. Pad A 1855 230' N & 20' W of SE corner of pad 10' BFG 2 6 120.6 28.8 31.4 91.8 106 1856 230' N & 20' W of SE corner of pad 9' BFG 2 6 120.1 28.5 31.1 91.6 106 1857 230' N & 20' W of SE corner of pad 8' BFG 1 6 120.5 28.6 31.1 91.9 96 1858 230' N & 20' W of SE corner of pad 7' BFG 1 6 120.5 28.9 31.5 91.6 95 1859 230' N & 20' W of SE corner of pad 6' BFG 1 6 120.5 28.7 31.3 91.8 95 1860 230' N & 80' W of SE corner of pad 10' BFG 1 6 120.4 28.9 31.6 91.5 95 1861 230' N & 80' W of SE corner of pad 9' BFG 1 6 120.4 28.7 31.3 91.7 95 1862 230' N & 80' W of SE corner of pad 8' BFG 1 6 120.3 28.5 31.1 91.8 95 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0037 06/21/14 06/27/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1863 230' N & 80' W of SE corner of pad 7' BFG 1 6 120.4 28.8 31.4 91.6 95 1864 230' N & 80' W of SE corner of pad 6' BFG 1 6 120.1 28.9 31.7 91.2 95 1865 230' N & 130' W of SE corner of pad 10' BFG 1 6 120.0 29.0 31.9 91.0 95 1866 230' N & 130' W of SE corner of pad 9' BFG10'1 6 120.5 28.9 31.5 91.6 95 1867 230' N & 130' W of SE corner of pad 8' BFG 1 6 120.5 28.7 31.3 91.8 95 1868 230' N & 130' W of SE corner of pad 7' BFG 1 6 120.2 28.9 31.7 91.3 95 1869 230' N & 130' W of SE corner of pad 6' BFG 1 6 120.5 28.8 31.4 91.7 95 1870 230' N & 20' W of SE corner of pad 5' BFG 1 6 119.9 28.9 31.8 91.0 95 1871 230' N & 20' W of SE corner of pad 4' BFG 1 6 119.5 28.7 31.6 90.8 94 1872 230' N & 20' W of SE corner of pad 3' BFG 1 6 120.0 28.6 31.3 91.4 95 1873 230' N & 20' W of SE corner of pad 2' BFG 1 6 120.1 28.5 31.1 91.6 95 1874 230' N & 20' W of SE corner of pad 1' BFG 1 6 120.1 28.8 31.5 91.3 95 1875 230' N & 80' W of SE corner of pad 5' BFG 1 6 120.3 28.5 31.1 91.8 95 1876 230' N & 80' W of SE corner of pad 4' BFG 1 6 119.3 28.1 30.8 91.2 95 1877 230' N & 80' W of SE corner of pad 3' BFG 1 6 120.4 28.8 31.4 91.6 95 1878 230' N & 80' W of SE corner of pad 2' BFG 1 6 120.3 28.6 31.2 91.7 95 1879 230' N & 80' W of SE corner of pad 1' BFG 1 6 120.1 28.8 31.5 91.3 95 1880 230' N & 130' W of SE corner of pad 5' BFG 1 6 120.0 28.5 31.1 91.5 95 1881 230' N & 130' W of SE corner of pad 4' BFG 1 6 119.7 28.6 31.4 91.1 95 1882 230' N & 130' W of SE corner of pad 3' BFG 1 6 120.2 28.6 31.2 91.6 95 1883 230' N & 130' W of SE corner of pad 2' BFG 1 6 119.1 28.2 31.0 90.9 94 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 4 of 5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0037 06/21/14 06/27/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1884 230' N & 130' W of SE corner of pad 1' BFG 1 6 119.7 28.5 31.3 91.2 95 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 5 of 5 GRADATION REPORT Report Number:94141126.0038 Service Date:06/20/14 8901 Carpenter Frwy., Suite 100 Report Date:06/27/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Perform gradation tests on lime stabilized soil. Terracon Rep.: Armando Rendon Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940006, 05-23-14, Rev.2 Page 1 of 1 dgr SERVICES:SPECIFICATION REQUIREMENTS: Minimum Passing 1 3/4” Sieve (%):100 Performed gradation tests on lime treated soil. Minimum Passing #4 Sieve (%): 60 TEST METHOD:NCTCOG Sample Condition: Field Moist TEST LOCATION:Bldg. Pad D TEST NO.LOCATION 1 3/4” SIEVE % PASSING #4 SIEVE % PASSING 1 20’ N & 20’ E of SW corner of pad 100 63 2 100’ N & 100’ E of SW corner of pad 100 61 3 200’ N & 100’ E of SW corner of pad 100 64 4 300’ N & 100’ E of SW corner of pad 100 64 5 400’ N & 100’ E of SW corner of pad 100 63 6 20’ N & 190’ E of SW corner of pad 100 61 7 100’ N & 190’ E of SW corner of pad 100 64 8 200’ N & 150’ E of SW corner of pad 100 63 9 300’ N & 150’ E of SW corner of pad 100 65 10 400’ N & 180’ E of SW corner of pad 100 61 11 50’ N & 100’ E of SW corner of pad 100 63 12 200’ N & 50’ E of SW corner of pad 100 64 13 300’ N & 30’ E of SW corner of pad 100 64 14 400’ N & 20’ E of SW corner of pad 100 63 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0041 06/24/14 06/25/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 95-1/+3296.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 95-2/+2386.830.294141126.0036 Lime treated dark and light brown clay ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad A 1605 260' N & 20' W of SE corner of pad 10' BFG 1 6 119.0 28.9 32.1 90.1 94 1606 260' N & 20' W of SE corner of pad 9' BFG 1 6 119.4 28.8 31.8 90.6 94 1607 260' N & 20' W of SE corner of pad 8' BFG 1 6 119.5 28.7 31.6 90.8 94 1608 260' N & 20' W of SE corner of pad 7' BFG 1 6 119.4 28.9 31.9 90.5 94 1609 260' N & 20' W of SE corner of pad 6' BFG 1 6 119.7 28.8 31.7 90.9 94 1610 260' N & 80' W of SE corner of pad 10' BFG 1 6 119.0 28.8 31.9 90.2 94 1611 260' N & 80' W of SE corner of pad 9' BFG 1 6 119.1 28.6 31.6 90.5 94 1612 260' N & 80' W of SE corner of pad 8' BFG 1 6 119.2 28.5 31.4 90.7 94 1613 260' N & 80' W of SE corner of pad 7' BFG 1 6 119.1 28.7 31.7 90.4 94 1614 260' N & 80' W of SE corner of pad 6' BFG 1 6 119.8 29.0 31.9 90.8 94 1615 260' N & 130' W of SE corner of pad 10' BFG 1 6 118.8 28.8 32.0 90.0 94 1616 260' N & 130' W of SE corner of pad 9' BFG 1 6 120.3 29.0 31.8 91.3 95 1617 260' N & 130' W of SE corner of pad 8' BFG 1 6 119.1 28.6 31.6 90.5 94 1618 260' N & 130' W of SE corner of pad 7' BFG 1 6 119.0 28.7 31.8 90.3 94 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0041 06/24/14 06/25/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1619 260' N & 130' W of SE corner of pad 6' BFG 1 6 119.2 28.5 31.4 90.7 94 Storm Sewer Line B 1620 Sta. 1+00 4' BFG 2 6 115.7 23.6 25.6 92.1 96 1621 Sta. 1+00 3.2' BFG 2 6 115.7 23.3 25.2 92.4 96 1622 Sta. 1+00 2.4' BFG 2 6 115.5 23.5 25.5 92.0 96 1623 Sta. 1+00 1.6' BFG 2 6 115.7 23.4 25.3 92.3 96 1624 Sta. 1+00 0.8' BFG 2 6 116.3 23.8 25.7 92.5 96 1625 Sta. 1+00 Final 2 6 116.7 24.0 25.9 92.7 96 Bldg. Pad A 1626 260' N & 15' W of SE corner of pad 5' BFG 1 6 119.6 28.8 31.7 90.8 94 1627 260' N & 15' W of SE corner of pad 4' BFG 1 6 119.1 28.5 31.5 90.6 94 1628 260' N & 15' W of SE corner of pad 3' BFG 1 6 119.2 28.4 31.3 90.8 94 1629 260' N & 15' W of SE corner of pad 2' BFG 1 6 119.1 28.6 31.6 90.5 94 1630 260' N & 15' W of SE corner of pad 1' BFG 1 6 119.2 28.8 31.9 90.4 94 1631 260' N & 70' W of SE corner of pad 5' BFG 1 6 119.1 28.3 31.2 90.8 94 1632 260' N & 70' W of SE corner of pad 4' BFG 1 6 118.9 28.5 31.5 90.4 94 1633 260' N & 70' W of SE corner of pad 3' BFG 1 6 119.7 28.8 31.7 90.9 94 1634 260' N & 70' W of SE corner of pad 2' BFG 1 6 119.0 28.4 31.3 90.6 94 1635 260' N & 70' W of SE corner of pad 1' BFG 1 6 119.4 28.7 31.6 90.7 94 1636 260' N & 125' W of SE corner of pad 5' BFG 1 6 119.4 28.5 31.3 90.9 94 1637 260' N & 125' W of SE corner of pad 4' BFG 1 6 119.3 28.6 31.5 90.7 94 1638 260' N & 125' W of SE corner of pad 3' BFG 1 6 119.1 28.7 31.7 90.4 94 1639 260' N & 125' W of SE corner of pad 2' BFG 1 6 118.9 28.3 31.2 90.6 94 1640 260' N & 125' W of SE corner of pad 1' BFG 1 6 119.1 28.6 31.6 90.5 94 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0041 06/24/14 06/25/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad D 1641 20' N & 20' E of SW corner of pad Final 3 6 109.3 26.6 32.2 82.7 95 1642 100' N & 100' E of SW corner of pad Final 3 6 109.9 26.5 31.8 83.4 96 1643 200' N & 100' E of SW corner of pad Final 3 6 109.4 26.3 31.6 83.1 96 1644 300' N & 100' E of SW corner of pad Final 3 6 109.2 26.4 31.9 82.8 95 1645 400' N & 100' E of SW corner of pad Final 3 6 110.9 27.3 32.6 83.6 96* 1646 20' N & 190' E of SW corner of pad Final 3 6 110.5 27.5 33.1 83.0 96* 1647 100' N & 190' E of SW corner of pad Final 3 6 108.7 26.3 31.9 82.4 95 1648 200' N & 150' E of SW corner of pad Final 3 6 110.2 26.7 32.0 83.5 96 1649 300' N & 150' E of SW corner of pad Final 3 6 110.2 26.5 31.7 83.7 96 1650 400' N & 180' E of SW corner of pad Final 3 6 110.6 26.4 31.4 84.2 97 1651 500' N & 100' E of SW corner of pad Final 3 6 110.2 26.6 31.8 83.6 96 1652 200' N & 150' E of SW corner of pad Final 3 6 110.1 26.8 32.2 83.3 96 1653 300' N & 30' E of SW corner of pad Final 3 6 110.5 26.5 31.6 84.0 97 Storm Sewer Line B 1654 Sta. 3+00 4' BFG 2 6 115.9 23.1 24.9 92.8 96 1655 Sta. 3+00 3.2' BFG 2 6 115.3 22.8 24.6 92.5 96 1656 Sta. 3+00 2.4' BFG 2 6 115.7 23.0 24.8 92.7 96 1657 Sta. 3+00 1.6' BFG 2 6 116.3 23.3 25.0 93.0 97 1658 Sta. 3+00 0.8' BFG 2 6 115.5 22.9 24.7 92.6 96 1659 Sta. 3+00 Final 2 6 116.0 23.1 24.9 92.9 97 Comments: Datum: BFG - Below final grade Serial No: An asterisk (*) appears next to the test results which do not meet the project requirements as noted above. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 3 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0041 06/24/14 06/25/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 4 of 4 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0042 06/25/14 06/30/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 95-2/+2186.830.294141126.0036 Lime treated dark and light brown clay ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad D 1889 RETEST OF TEST #1645 - 400' N & 100' E of SW corner of pad Final 1 6 108.6 26.1 31.6 82.5 95 1890 RETEST OF TEST #1646 - 20' N & 190' E of SW corner of pad Final 1 6 109.3 26.4 31.8 82.9 96 1891 500' N & 100' E of SW corner of pad Final 1 6 108.6 25.5 30.7 83.1 96 1892 600' N & 100' E of SW corner of pad Final 1 6 110.1 26.3 31.4 83.8 97 1893 700' N & 100' E of SW corner of pad Final 1 6 109.3 26.3 31.7 83.0 96 1894 500' N & 30' E of SW corner of pad Final 1 6 110.0 26.6 31.9 83.4 96 1895 600' N & 20' E of SW corner of pad Final 1 6 115.7 27.7 31.5 88.0 101 1896 700' N & 20' E of SW corner of pad Final 1 6 109.2 26.4 31.9 82.8 95 1897 500' N & 190' E of SW corner of pad Final 1 6 109.6 26.1 31.2 83.5 96 1898 600' N & 190' E of SW corner of pad Final 1 6 109.7 26.6 32.0 83.1 96 1899 700' N & 190' E of SW corner of pad Final 1 6 110.1 26.5 31.7 83.6 96 Comments: Datum:Serial No: Test and/or retest results on this report meet project requirements as noted above. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0042 06/25/14 06/30/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 2 SOIL-LIME MIXTURE PULVERIZATION REPORT Report Number:94141126.0043 Service Date:06/24/14 8901 Carpenter Frwy., Suite 100 Report Date:06/30/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Travel to the project site to perform testing/observation services as requested. Terracon Rep.: Armando Rendon Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940006, 05-23-14, Rev.2 Page 1 of 1 dgr SERVICES:SPECIFICATION REQUIREMENTS: Minimum Passing 1 3/4” Sieve (%):100 Performed gradation tests on lime treated soil. Minimum Passing #4 Sieve (%): 60 TEST METHOD:NCTCOG Sample Condition: Field Moist TEST LOCATION:Bldg. Pad D TEST NO.LOCATION 1 3/4” SIEVE % PASSING #4 SIEVE % PASSING 1 500’ N & 100’ E of SW corner of pad 100 64 2 600’ N & 100’ E of SW corner of pad 100 62 3 700’ N & 100’ E of SW corner of pad 100 62 4 500’ N & 30’ E of SW corner of pad 100 64 5 600’ N & 20’ E of SW corner of pad 100 63 6 700’ N & 20’ E of SW corner of pad 100 64 7 500’ N & 190’ E of SW corner of pad 100 62 8 600’ N & 190’ E of SW corner of pad 100 62 9 700’ N & 190’ E of SW corner of pad 100 62 SOIL-LIME MIXTURE PULVERIZATION REPORT Report Number:94141126.0044 Service Date:06/25/14 8901 Carpenter Frwy., Suite 100 Report Date:06/30/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Travel to the project site to perform testing/observation services as requested. Terracon Rep.: Armando Rendon Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940006, 05-23-14, Rev.2 Page 1 of 1 dgr SERVICES:SPECIFICATION REQUIREMENTS: Minimum Passing 1 3/4” Sieve (%):100 Performed gradation tests on lime treated soil. Minimum Passing #4 Sieve (%): 60 TEST METHOD:NCTCOG Sample Condition: Field Moist TEST LOCATION:Bldg. Pad B TEST NO.LOCATION 1 3/4” SIEVE % PASSING #4 SIEVE % PASSING 1 20’ N & 20’ W of SE corner of pad 100 62 2 100’ N & 20’ W of SE corner of pad 100 64 3 200’ N & 20’ W of SE corner of pad 100 64 4 300’ N & 20’ W of SE corner of pad 100 62 5 50’ N & 100’ W of SE corner of pad 100 62 6 200’ N & 100’ E of SE corner of pad 100 63 7 300’ N & 100’ E of SE corner of pad 100 63 8 100’ N & 120’ W of SE corner of pad 100 64 9 260’ N & 120’ W of SE corner of pad 100 62 10 160’ N & 110’ W of SE corner of pad 100 63 SOIL- LIME MIXTURE PULVERIZATION REPORT Report Number:94141126.0045 Service Date:06/19/14 8901 Carpenter Frwy., Suite 100 Report Date:06/26/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940006, 05-23-14, Rev.2 Page 1 of 2 dgr SERVICES:SPECIFICATION REQUIREMENTS: Minimum Passing 1 3/4” Sieve (%):100 Performed gradation tests on lime treated soil. Minimum Passing #4 Sieve (%): 60 TEST METHOD:NCTCOG Sample Condition: Field Dry TEST LOCATION:Bldg. Pad C TEST NO.LOCATION 1 3/4” SIEVE % PASSING #4 SIEVE % PASSING 1 20’ N & 30’ E of SW corner of pad 100 64 2 100’ N & 100’ E of SW corner of pad 100 66 3 200’ N & 160’ E of SW corner of pad 100 64 4 300’ N & 40’ E of SW corner of pad 100 62 5 400’ N & 100’ E of SW corner of pad 100 66 6 460’ N & 150’ E of SW corner of pad 100 64 7 400’ N & 20’ E of SW corner of pad 100 66 8 30’ N & 120’ E of SW corner of pad 100 63 9 200’ N & 50’ E of SW corner of pad 100 62 10 300’ N & 150’ E of SW corner of pad 100 64 11 200’ N & 100’ E of SW corner of pad 100 61 12 300’ N & 100’ E of SW corner of pad 100 63 13 100’ N & 150’ E of SW corner of pad 100 61 14 150’ N & 60’ E of SW corner of pad 100 64 SOIL- LIME MIXTURE PULVERIZATION REPORT Report Number:94141126.0045 Service Date:06/19/14 8901 Carpenter Frwy., Suite 100 Report Date:06/26/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Travel to the project site to perform testing/observation services as requested. Terracon Rep.: Armando Rendon Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940006, 05-23-14, Rev.2 Page 2 of 2 dgr TEST NO.LOCATION 1 3/4” SIEVE % PASSING #4 SIEVE % PASSING 15 400’ N & 100’ E of SW corner of pad 100 63 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0047 06/27/14 06/27/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 95-2/+2186.830.294141126.0036 Lime treated dark and light brown clay ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Building Pad B 1885 20' N & 20' E of SW corner of pad Final 1 6 111.4 30.7 38.1 80.7 93** 1886 50' N & 50' E of SW corner of pad Final 1 6 111.7 30.4 37.4 81.3 94** 1887 100' N & 50' E of SW corner of pad Final 1 6 113.2 30.5 36.9 82.7 95* 1888 200' N & 100' E of SW corner of pad Final 1 6 113.5 30.4 36.6 83.1 96* Comments: Datum:Serial No: An asterisk (*) appears next to the test results which do not meet the project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 1 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0048 06/28/14 07/08/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 95-2/+2186.830.294141126.0036 Lime treated dark and light brown clay ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad B 1900 RETEST OF TEST #1885 - 20' N & 20' E of SW corner of pad Final 1 6 110.8 26.6 31.6 84.2 97 1901 RETEST OF TEST #1886 - 50' N & 50' E of SW corner of pad Final 1 6 111.9 27.1 31.9 84.8 98 1902 RETEST OF TEST #1887 - 100' N & 50' E of SW corner pad Final 1 6 112.0 27.3 32.2 84.7 98 1903 RETEST OF TEST #1888 - 200' N & 100' E of SW corner of pad Final 1 6 108.5 26.2 31.8 82.3 95 1904 20' N & 120' E of SW corner of pad Final 1 6 110.2 26.7 32.0 83.5 96 1905 100' N & 120' E of SW corner of pad Final 1 6 109.9 26.8 32.2 83.1 96 1906 200' N & 20' E of SW corner of pad Final 1 6 110.7 26.7 31.8 84.0 97 1907 300' N & 20' E of SW corner of pad Final 1 6 110.4 26.5 31.6 83.9 97 1908 300' N & 110' E of SW corner of pad Final 1 6 111.6 27.0 31.9 84.6 97 1909 70' N & 80' E of SW corner of pad Final 1 6 111.0 26.5 31.4 84.5 97 Comments: Datum:Serial No: Test and/or retest results on this report meet project requirements as noted above. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0048 06/28/14 07/08/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0049 06/30/14 07/08/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 95-2/+2186.830.294141126.0036 Lime treated dark and light brown clay ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad D 1910 20' S & 20' E of NW corner of pad Final 1 6 112.1 27.3 32.2 84.8 98 1911 20' S & 110' E of NW corner of pad Final 1 6 110.7 26.8 31.9 83.9 97 Bldg. Pad B 1912 20' S & 20' E of NW corner of pad Final 1 6 111.3 26.7 31.6 84.6 97 1913 20' S & 10' E of NW corner of pad Final 1 6 111.0 26.9 32.0 84.1 97 Comments: Datum:Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 1 GRADATION REPORT Report Number:94141126.0052 Service Date:06/30/14 8901 Carpenter Frwy., Suite 100 Report Date:07/08/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Perform gradation tests on lime stabilized soil. Terracon Rep.: Armando Rendon Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940006, 05-23-14, Rev.2 Page 1 of 1 dgr SERVICES:SPECIFICATION REQUIREMENTS: Minimum Passing 1 3/4” Sieve (%):100 Performed gradation tests on lime treated soil. Minimum Passing #4 Sieve (%): 60 TEST METHOD:NCTCOG Sample Condition: Field Moist TEST LOCATION:Bldg. Pad A TEST NO.LOCATION 1 3/4” SIEVE % PASSING #4 SIEVE % PASSING 1 20’ N & 20’ W of SE corner of pad 100 64 2 100’ N & 100’ W of SE corner of pad 100 61 3 200’ N & 20’ W of SE corner of pad 100 63 4 200’ N & 110’ W of SE corner of pad 100 64 5 260’ N & 30’ W of SE corner of pad 100 63 6 260’ N & 110’ W of SE corner of pad 100 63 7 20’ N & 100’ W of SE corner of pad 100 64 8 100’ N & 20’ W of SE corner of pad 100 63 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0053 07/01/14 07/08/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 95-2/+2186.830.294141126.0036 Lime treated dark and light brown clay ASTM D698 95-1/+3296.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Bldg. Pad A 1914 20' N & 20' W of SE corner of pad Final 1 6 110.4 26.7 31.9 83.7 96 1915 100' N & 100' W of SE corner of pad Final 1 6 110.7 26.6 31.6 84.1 97 1916 200' N & 20' W of SE corner of pad Final 1 6 110.4 26.6 31.8 83.8 97 1917 200' N & 10' W of SE corner of pad Final 1 6 110.4 26.8 32.0 83.6 96 1918 260' N & 30' W of SE corner of pad Final 1 6 109.2 26.1 31.4 83.1 96 1919 260' N & 110' W of SE corner of pad Final 1 6 111.0 26.1 30.8 84.9 98 1920 20' N & 100' W of SE corner of pad Final 1 6 110.1 26.3 31.4 83.8 97 1921 100' N & 20' W of SE corner of pad Final 1 6 109.3 26.3 31.7 83.0 96 Storm Sewer Line B 1922 Sta. 5+00 40' BFG 2 117.4 23.3 24.8 94.1 98 1923 Sta. 5+00 32' BFG 2 6 116.9 23.1 24.6 93.8 98 1924 Sta. 5+00 24' BFG 2 6 117.8 23.5 24.9 94.3 98 1925 Sta. 5+00 16' BFG24'2 6 117.0 23.0 24.5 94.0 98 1926 Sta. 5+00 0.8' BFG 2 6 117.1 23.2 24.7 93.9 98 1927 Sta. 5+00 Final 2 6 117.2 23.0 24.4 94.2 98 1928 Sta. 7+00 40' BFG 2 6 118.1 23.1 24.3 95.0 99 1929 Sta. 7+00 32' BFG 2 6 117.6 22.8 24.0 94.8 99 1930 Sta. 7+00 24' BFG 2 6 117.1 22.5 23.8 94.6 98 1931 Sta. 7+00 16' BFG 2 6 117.8 22.9 24.1 94.9 99 1932 Sta. 7+00 0.8' BFG 2 6 117.8 23.1 24.4 94.7 98 1933 Sta. 7+00 Final 2 6 117.2 22.7 24.0 94.5 98 1934 Sta. 1+50 60' BFG 2 6 117.3 22.5 23.7 94.8 99 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0053 07/01/14 07/08/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 1935 Sta. 1+50 52' BFG 2 6 118.0 22.8 23.9 95.2 99 1936 Sta. 1+50 44' BFG 2 6 117.4 22.4 23.6 95.0 99 1937 Sta. 1+50 36' BFG 2 6 118.2 22.9 24.0 95.3 99 1938 Sta. 1+50 28' BFG 2 6 117.4 22.5 23.7 94.9 99 1939 Sta. 1+50 20' BFG 2 6 117.8 22.7 23.9 95.1 99 1940 Sta. 1+50 12' BFG 2 6 117.8 22.4 23.5 95.4 99 1941 Sta. 1+50 0.4' BFG 2 6 117.8 22.6 23.7 95.2 99 1942 Sta. 1+50 Final 2 6 117.9 22.9 24.1 95.0 99 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 2 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0056 07/07/14 07/16/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1557 1269 Plant: Ticket No.: P259 25890845 Field Test Data Test Air Content (%): Result Specification 6 3/4 5-7 1.2 0-3 92 89 146.8 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/07/14 1700 Jonathan Baze Cloudy, medium wind 50/50 10 0 0 Bldg. C, Piers at J/3, I/3 & H/3Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0055 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/14/14 7 42,220 5 3,360 1 2 4.00 12.57 08/04/14 28 1 3 4.00 12.57 08/04/14 28 1 4 4.00 12.57 08/04/14 28 1 5 4.00 12.57 09/01/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0056 07/07/14 08/05/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1557 1269 Plant: Ticket No.: P259 25890845 Field Test Data Test Air Content (%): Result Specification 6 3/4 5-7 1.2 0-3 92 89 146.8 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/07/14 1700 Jonathan Baze Cloudy, medium wind 50/50 10 0 0 Bldg. C, Piers at J/3, I/3 & H/3Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0055 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/14/14 7 42,220 5 3,360 1 2 4.00 12.57 08/04/14 28 53,360 4 4,250 1 3 4.00 12.57 08/04/14 28 54,250 4 4,320 1 4 4.00 12.57 08/04/14 28 53,580 5 4,260 Average (28 days) 4,280 1 5 4.00 12.57 09/01/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0056 07/07/14 09/02/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1557 1269 Plant: Ticket No.: P259 25890845 Field Test Data Test Air Content (%): Result Specification 6 3/4 5-7 1.2 0-3 92 89 146.8 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/07/14 1700 Jonathan Baze Cloudy, medium wind 50/50 10 0 0 Bldg. C, Piers at J/3, I/3 & H/3Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0055 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/14/14 7 42,220 5 3,360 1 2 4.00 12.57 08/04/14 28 53,360 4 4,250 1 3 4.00 12.57 08/04/14 28 54,250 4 4,320 1 4 4.00 12.57 08/04/14 28 53,580 5 4,260 Average (28 days) 4,280 1 5 4.00 12.57 09/01/14 56 56,240 2 4,480 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0058 07/08/14 07/17/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1719 1236 Plant: Ticket No.: P136 Field Test Data Test Air Content (%): Result Specification 6 1/2 5-7 0.9 0-3 96 92 148.0 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/08/14 1800 Jonathan Baze Partly cloudy 79/79 9 0 0 Piers O/3 & F/4; Bldg. DSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0057 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/15/14 7 38,470 5 3,060 1 2 4.00 12.57 08/05/14 28 1 3 4.00 12.57 08/05/14 28 1 4 4.00 12.57 08/05/14 28 1 5 4.00 12.57 09/02/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0058 07/08/14 08/06/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1719 1236 Plant: Ticket No.: P136 Field Test Data Test Air Content (%): Result Specification 6 1/2 5-7 0.9 0-3 96 92 148.0 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/08/14 1800 Jonathan Baze Partly cloudy 79/79 9 0 0 Piers O/3 & F/4; Bldg. DSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0057 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/15/14 7 38,470 5 3,060 1 2 4.00 12.57 08/05/14 28 53,560 2 4,260 1 3 4.00 12.57 08/05/14 28 52,730 4 4,200 1 4 4.00 12.57 08/05/14 28 51,730 3 4,120 Average (28 days) 4,190 1 5 4.00 12.57 09/02/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0058 07/08/14 09/03/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1719 1236 Plant: Ticket No.: P136 Field Test Data Test Air Content (%): Result Specification 6 1/2 5-7 0.9 0-3 96 92 148.0 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/08/14 1800 Jonathan Baze Partly cloudy 79/79 9 0 0 Piers O/3 & F/4; Bldg. DSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0057 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/15/14 7 38,470 5 3,060 1 2 4.00 12.57 08/05/14 28 53,560 2 4,260 1 3 4.00 12.57 08/05/14 28 52,730 4 4,200 1 4 4.00 12.57 08/05/14 28 51,730 3 4,120 Average (28 days) 4,190 1 5 4.00 12.57 09/02/14 56 57,530 3 4,580 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0061 07/09/14 07/18/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 0851 1168 Plant: Ticket No.: P136 25892324 Field Test Data Test Air Content (%): Result Specification 7 5-7 1.2 0-3 87 86 146.4 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/09/14 1000 Jonathan Baze Clear & windy 10/20 10 20 0 Piers O/2, N/2 & M/2Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0060 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/16/14 7 42,550 1 3,390 1 2 4.00 12.57 08/06/14 28 1 3 4.00 12.57 08/06/14 28 1 4 4.00 12.57 08/06/14 28 1 5 4.00 12.57 09/03/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0061 07/09/14 08/07/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 0851 1168 Plant: Ticket No.: P136 25892324 Field Test Data Test Air Content (%): Result Specification 7 5-7 1.2 0-3 87 86 146.4 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/09/14 1000 Jonathan Baze Clear & windy 10/20 10 20 0 Piers O/2, N/2 & M/2Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0060 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/16/14 7 42,550 1 3,390 1 2 4.00 12.57 08/06/14 28 61,520 3 4,900 1 3 4.00 12.57 08/06/14 28 56,370 2 4,490 1 4 4.00 12.57 08/06/14 28 55,450 3 4,410 Average (28 days) 4,600 1 5 4.00 12.57 09/03/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0061 07/09/14 09/04/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 0851 1168 Plant: Ticket No.: P136 25892324 Field Test Data Test Air Content (%): Result Specification 7 5-7 1.2 0-3 87 86 146.4 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/09/14 1000 Jonathan Baze Clear & windy 10/20 10 20 0 Piers O/2, N/2 & M/2Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0060 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/16/14 7 42,550 1 3,390 1 2 4.00 12.57 08/06/14 28 61,520 3 4,900 1 3 4.00 12.57 08/06/14 28 56,370 2 4,490 1 4 4.00 12.57 08/06/14 28 55,450 3 4,410 Average (28 days) 4,600 1 5 4.00 12.57 09/03/14 56 67,980 2 5,410 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0065 07/10/14 07/21/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0800 1286 Plant: Ticket No.: P259 25893354 Field Test Data Test Air Content (%): Result Specification 6 90 85 152.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/10/14 1130 Jason Carrizales Clear, hot 410/550 10 2 0 Piers B/2, D/2, & E/sSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0064, dated 07/10/14, for Pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/17/14 7 37,110 5 2,950 1 2 4.00 12.57 08/07/14 28 1 3 4.00 12.57 08/07/14 28 1 4 4.00 12.57 08/07/14 28 1 5 4.00 12.57 09/04/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0065 07/10/14 08/09/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0800 1286 Plant: Ticket No.: P259 25893354 Field Test Data Test Air Content (%): Result Specification 6 90 85 152.0 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/10/14 1130 Jason Carrizales Clear, hot 410/550 10 2 0 Piers B/2, D/2, & E/sSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0064, dated 07/10/14, for Pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/17/14 7 37,110 5 2,950 1 2 4.00 12.57 08/07/14 28 45,990 2 3,660 1 3 4.00 12.57 08/07/14 28 49,060 2 3,900 1 4 4.00 12.57 08/07/14 28 51,100 1 4,070 Average (28 days) 3,880 1 5 4.00 12.57 09/04/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0065 07/10/14 09/04/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0800 1286 Plant: Ticket No.: P259 25893354 Field Test Data Test Air Content (%): Result Specification 6 90 85 152.0 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/10/14 1130 Jason Carrizales Clear, hot 410/550 10 2 0 Piers B/2, D/2, & E/sSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0064, dated 07/10/14, for Pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/17/14 7 37,110 5 2,950 1 2 4.00 12.57 08/07/14 28 45,990 2 3,660 1 3 4.00 12.57 08/07/14 28 49,060 2 3,900 1 4 4.00 12.57 08/07/14 28 51,100 1 4,070 Average (28 days) 3,880 1 5 4.00 12.57 09/04/14 56 53,570 4 4,260 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0069 07/11/14 07/21/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1434 1292 Plant: Ticket No.: P136 25894980 Field Test Data Test Air Content (%): Result Specification 6 1/2 5-7 1.0 0-3 91 93 149.6 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/11/14 1530 Jonathan Baze Clear, windy 40/44 10 0 0 Piers J.2/4, I.7/4, & I/4Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0068, dated 07/11/14, for Pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/18/14 7 42,720 3 3,400 1 2 4.00 12.57 08/08/14 28 1 3 4.00 12.57 08/08/14 28 1 4 4.00 12.57 08/08/14 28 1 5 4.00 12.57 09/05/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0069 07/11/14 08/09/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1434 1292 Plant: Ticket No.: P136 25894980 Field Test Data Test Air Content (%): Result Specification 6 1/2 5-7 1.0 0-3 91 93 149.6 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/11/14 1530 Jonathan Baze Clear, windy 40/44 10 0 0 Piers J.2/4, I.7/4, & I/4Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0068, dated 07/11/14, for Pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/18/14 7 42,720 3 3,400 1 2 4.00 12.57 08/08/14 28 55,420 5 4,410 1 3 4.00 12.57 08/08/14 28 52,700 2 4,190 1 4 4.00 12.57 08/08/14 28 57,060 2 4,540 Average (28 days) 4,380 1 5 4.00 12.57 09/05/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0069 07/11/14 09/05/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1434 1292 Plant: Ticket No.: P136 25894980 Field Test Data Test Air Content (%): Result Specification 6 1/2 5-7 1.0 0-3 91 93 149.6 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/11/14 1530 Jonathan Baze Clear, windy 40/44 10 0 0 Piers J.2/4, I.7/4, & I/4Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0068, dated 07/11/14, for Pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/18/14 7 42,720 3 3,400 1 2 4.00 12.57 08/08/14 28 55,420 5 4,410 1 3 4.00 12.57 08/08/14 28 52,700 2 4,190 1 4 4.00 12.57 08/08/14 28 57,060 2 4,540 Average (28 days) 4,380 1 5 4.00 12.57 09/05/14 56 61,680 3 4,910 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0071 07/11/14 07/18/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 95-1/+3195.324.294141126.0001 Dark brown clay with trace sand ASTM D698 95-1/+3296.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Storm Drain, Line A 1943 Sta. 6+50 1' BFG 1 6 117.0 24.4 26.3 92.6 97 1944 Sta. 6+50 Final 1 6 116.5 23.6 25.4 92.9 97 1945 Sta. 8+50 1' BFG 1 6 115.1 23.5 25.7 91.6 96 1946 Sta. 8+50 Final 1 6 115.4 23.0 24.9 92.4 97 1947 Sta. 10+50 1' BFG 1 6 116.8 23.5 25.2 93.3 98 1948 Sta. 10+50 Final 1 6 117.3 23.2 24.7 94.1 99 1949 Sta. 12+50 1' BFG 1 6 116.1 24.1 26.2 92.0 97 1950 Sta. 12+50 Final 1 6 117.6 24.2 25.9 93.4 98 1951 Sta. 14+50 1' BFG 1 6 117.8 24.0 25.6 93.8 98 1952 Sta. 14+50 Final 1 6 117.3 23.0 24.4 94.3 99 Line SS-1 1953 Sta. 1+00 8' BFG 2 6 114.8 23.0 25.0 91.8 95 1954 Sta. 1+00 7' BFG 2 6 116.4 23.9 25.8 92.5 96 1955 Sta. 1+00 6' BFG 2 6 115.7 23.6 25.6 92.1 96 1956 Sta. 1+00 5' BFG 2 6 116.7 23.1 24.7 93.6 97 1957 Sta. 1+00 4' BFG 2 6 116.3 21.8 23.1 94.5 98 1958 Sta. 1+00 3' BFG 2 6 117.0 23.1 24.6 93.9 98 1959 Sta. 1+00 2' BFG 2 6 115.8 22.1 23.6 93.7 97 1960 Sta. 1+00 1' BFG 2 6 118.4 23.3 24.5 95.1 99 1961 Sta. 1+00 Final 2 6 116.0 21.9 23.3 94.1 98 Comments: Datum: BFG - Below final grade Serial No:37232 Test and/or retest results on this report meet project requirements as noted above. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0071 07/11/14 07/18/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Mike w/Structure Tone Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Homero Gonzalez ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 2 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0075 07/14/14 07/23/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 0838 1269 Plant: Ticket No.: 259 25895808 Field Test Data Test Air Content (%): Result Specification 6 1.0 88 82 147.6 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/14/14 0940 Jason Carrizales 10/60 10 0 0 Piers @ G.6/4; H.3/4; G/4Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report No. 94141126.0073, dated 07/14/14, for pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/21/14 7 46,380 2 3,690 1 2 4.00 12.57 08/11/14 28 1 3 4.00 12.57 08/11/14 28 1 4 4.00 12.57 08/11/14 28 1 5 4.00 12.57 09/08/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jason Carrizales The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0075 07/14/14 08/13/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 0838 1269 Plant: Ticket No.: 259 25895808 Field Test Data Test Air Content (%): Result Specification 6 1.0 88 82 147.6 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/14/14 0940 Jason Carrizales 10/60 10 0 0 Piers @ G.6/4; H.3/4; G/4Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report No. 94141126.0073, dated 07/14/14, for pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/21/14 7 46,380 2 3,690 1 2 4.00 12.57 08/11/14 28 62,820 2 5,000 1 3 4.00 12.57 08/11/14 28 66,550 5 5,300 1 4 4.00 12.57 08/11/14 28 61,230 1 4,870 Average (28 days) 5,060 1 5 4.00 12.57 09/08/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jason Carrizales The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0075 07/14/14 09/09/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 0838 1269 Plant: Ticket No.: 259 25895808 Field Test Data Test Air Content (%): Result Specification 6 1.0 88 82 147.6 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/14/14 0940 Jason Carrizales 10/60 10 0 0 Piers @ G.6/4; H.3/4; G/4Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report No. 94141126.0073, dated 07/14/14, for pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/21/14 7 46,380 2 3,690 1 2 4.00 12.57 08/11/14 28 62,820 2 5,000 1 3 4.00 12.57 08/11/14 28 66,550 5 5,300 1 4 4.00 12.57 08/11/14 28 61,230 1 4,870 Average (28 days) 5,060 1 5 4.00 12.57 09/08/14 56 67,730 3 5,390 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jason Carrizales The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0076 07/14/14 07/21/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 95-1/+3196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 8" Sanitary Sewer, Line SS-1 1962 Sta. 2+00 8' BFG 1 6 115.9 22.4 24.0 93.5 97 1963 Sta. 2+00 7' BFG 1 6 115.7 22.7 24.4 93.0 97 1964 Sta. 2+00 6' BFG 1 6 115.3 22.7 24.5 92.6 96 1965 Sta. 2+00 5' BFG 1 6 116.2 22.4 23.9 93.8 98 1966 Sta. 2+00 4' BFG 1 6 116.4 22.2 23.6 94.2 98 1967 Sta. 2+00 3' BFG 1 6 116.9 22.1 23.3 94.8 99 1968 Sta. 4+00 8' BFG 1 6 115.8 22.3 23.9 93.5 97 1969 Sta. 4+00 7' BFG 1 6 115.9 22.8 24.5 93.1 97 1970 Sta. 4+00 6' BFG 1 6 115.0 22.9 24.9 92.1 96 1971 Sta. 4+00 5' BFG 1 6 115.1 22.7 24.6 92.4 96 1972 Sta. 4+00 4' BFG 1 6 115.3 22.2 23.8 93.1 97 1973 Sta. 4+00 3' BFG 1 6 116.0 22.1 23.5 93.9 98 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Superintendent Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Francisco J. Morillo ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 1 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0081 07/16/14 07/22/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 95-1/+3196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 95-1/+3295.324.294141126.0001 Dark brown clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) 8" Sanitary Sewer Line SS-1 1974 Sta. 2+00 2' BFG 1 6 116.8 22.9 24.4 93.9 98 1975 Sta. 2+00 1' BFG 1 6 116.2 23.1 24.8 93.1 97 1976 Sta. 2+00 FG 1 6 118.7 22.7 23.6 96.0 100 1977 Sta. 4+00 2' BFG 1 6 116.3 22.7 24.2 93.6 97 1978 Sta. 4+00 1' BFG 1 6 117.0 22.5 23.8 94.5 98 1979 Sta. 4+00 FG 1 6 117.4 22.3 23.5 95.1 99 1980 Sta. 6+00 4' BFG 1 6 115.3 23.1 25.0 92.2 96 1981 Sta. 6+00 3' BFG 1 6 116.4 23.5 25.3 92.9 97 1982 Sta. 6+00 2' BFG 1 6 116.0 22.8 24.5 93.2 97 1983 Sta. 6+00 1' BFG 1 6 116.4 22.6 24.1 93.8 98 1984 Sta. 8+00 4' BFG 1 6 118.5 23.5 24.7 95.0 99 1985 Sta. 8+00 3' BFG 1 6 118.7 23.1 24.2 95.6 99 1986 Sta. 8+00 2' BFG 1 6 118.1 22.7 23.8 95.4 99 1987 Sta. 8+00 1' BFG 1 6 118.8 22.8 23.7 96.0 100 8" Water Line, Line W-2 1988 Sta. 19+00 3' BFG 2 6 116.3 23.3 25.0 93.0 98 1989 Sta. 19+00 2' BFG 2 6 115.7 23.4 25.4 92.3 97 1990 Sta. 19+00 1' BFG 2 6 114.2 22.7 24.8 91.5 96 1991 Sta. 17+00 3' BFG 2 6 114.2 23.3 25.6 90.9 95 1992 Sta. 17+00 2' BFG 2 6 115.0 23.4 25.5 91.6 96 1993 Sta. 17+00 1' BFG 2 6 115.0 23.0 25.0 92.0 97 1994 Sta. 15+00 3' BFG 2 6 115.8 23.4 25.3 92.4 97 1995 Sta. 15+00 2' BFG 2 6 116.2 23.0 24.7 93.2 98 1996 Sta. 15+00 1' BFG 2 6 116.4 22.9 24.5 93.5 98 1997 Sta. 13+00 3' BFG 2 6 116.2 23.3 25.1 92.9 97 1998 Sta. 13+00 2' BFG 2 6 117.1 23.1 24.6 94.0 99 1999 Sta. 13+00 1' BFG 2 6 118.1 23.1 24.3 95.0 100 2000 Sta. 11+00 3' BFG 2 6 116.6 23.6 25.4 93.0 98 2001 Sta. 11+00 2' BFG 2 6 117.2 23.4 24.9 93.8 98 2002 Sta. 11+00 1' BFG 2 6 117.4 23.1 24.5 94.3 99 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0081 07/16/14 07/22/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Superintendent Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Francisco J. Morillo ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 2 FOUNDATION OBSERVATIONS REPORT Report Number:94141126.0083 Service Date:07/16/14 8901 Carpenter Frwy., Suite 100 Report Date:07/23/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Drilled belled (underreamed) pier observation. Terracon Rep.: Jonathan Baze Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 sa On this date, Terracon's representative arrived at the above referenced job site as scheduled for straight shaft pier observation. See the attached sheet(s) for recorded data. NOTE:Piers M/4, J.8/1, J.2/1, I.8/1, I.2/1, H.8/1 & H.2/1 were drilled down to the elevations where the underreams were to be done. The drillers belling tool broke and wouldn’t be fixed at this time. Piers were backfilled and drilling was cancelled. Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0089 07/21/14 07/30/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 0951 1283 Plant: Ticket No.: P259 25899836 Field Test Data Test Air Content (%): Result Specification 5 1/2 5-7 1.2 0-3 91 88 149.2 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/21/14 1130 Jonathan Baze Cloudy, medium winds 10/35 10 10 0 Piers J.2/1, J.8/1, & M/4Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0088, dated 07/21/14, for Pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/28/14 7 48,570 1 3,870 1 2 4.00 12.57 08/18/14 28 1 3 4.00 12.57 08/18/14 28 1 4 4.00 12.57 08/18/14 28 1 5 4.00 12.57 09/15/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0089 07/21/14 08/19/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 0951 1283 Plant: Ticket No.: P259 25899836 Field Test Data Test Air Content (%): Result Specification 5 1/2 5-7 1.2 0-3 91 88 149.2 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/21/14 1130 Jonathan Baze Cloudy, medium winds 10/35 10 10 0 Piers J.2/1, J.8/1, & M/4Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0088, dated 07/21/14, for Pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/28/14 7 48,570 1 3,870 1 2 4.00 12.57 08/18/14 28 59,870 3 4,760 1 3 4.00 12.57 08/18/14 28 55,560 2 4,420 1 4 4.00 12.57 08/18/14 28 67,520 2 5,370 Average (28 days) 4,850 1 5 4.00 12.57 09/15/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0089 07/21/14 09/16/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 0951 1283 Plant: Ticket No.: P259 25899836 Field Test Data Test Air Content (%): Result Specification 5 1/2 5-7 1.2 0-3 91 88 149.2 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/21/14 1130 Jonathan Baze Cloudy, medium winds 10/35 10 10 0 Piers J.2/1, J.8/1, & M/4Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0088, dated 07/21/14, for Pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/28/14 7 48,570 1 3,870 1 2 4.00 12.57 08/18/14 28 59,870 3 4,760 1 3 4.00 12.57 08/18/14 28 55,560 2 4,420 1 4 4.00 12.57 08/18/14 28 67,520 2 5,370 Average (28 days) 4,850 1 5 4.00 12.57 09/15/14 56 67,510 2 5,370 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0091 07/22/14 07/31/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1111 1264 Plant: Ticket No.: 259 25900850 Field Test Data Test Air Content (%): Result Specification 5 3/4 5-7 1.4 0-3 90 86 149.3 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/22/14 1230 Jonathan Baze Clear 10/10 10 5 0 Piers @ K/2. 3Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report No. 94141126.0090, dated 07/22/14, for pier locations, and Pier Caps @ F/2, 3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/29/14 7 47,730 4 3,800 1 2 4.00 12.57 08/19/14 28 1 3 4.00 12.57 08/19/14 28 1 4 4.00 12.57 08/19/14 28 1 5 4.00 12.57 09/16/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0091 07/22/14 08/19/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1111 1264 Plant: Ticket No.: 259 25900850 Field Test Data Test Air Content (%): Result Specification 5 3/4 5-7 1.4 0-3 90 86 149.3 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/22/14 1230 Jonathan Baze Clear 10/10 10 5 0 Piers @ K/2. 3Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report No. 94141126.0090, dated 07/22/14, for pier locations, and Pier Caps @ F/2, 3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/29/14 7 47,730 4 3,800 1 2 4.00 12.57 08/19/14 28 61,000 2 4,850 1 3 4.00 12.57 08/19/14 28 55,020 3 4,380 1 4 4.00 12.57 08/19/14 28 60,120 2 4,780 Average (28 days) 4,670 1 5 4.00 12.57 09/16/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0091 07/22/14 09/17/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1111 1264 Plant: Ticket No.: 259 25900850 Field Test Data Test Air Content (%): Result Specification 5 3/4 5-7 1.4 0-3 90 86 149.3 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/22/14 1230 Jonathan Baze Clear 10/10 10 5 0 Piers @ K/2. 3Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report No. 94141126.0090, dated 07/22/14, for pier locations, and Pier Caps @ F/2, 3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/29/14 7 47,730 4 3,800 1 2 4.00 12.57 08/19/14 28 61,000 2 4,850 1 3 4.00 12.57 08/19/14 28 55,020 3 4,380 1 4 4.00 12.57 08/19/14 28 60,120 2 4,780 Average (28 days) 4,670 1 5 4.00 12.57 09/16/14 56 67,560 4 5,380 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 SAMPLE PICK-UP REPORT Report Number:94141126.0092 Service Date:07/22/14 8901 Carpenter Frwy., Suite 100 Report Date:07/25/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Concrete cylinder pickup. Terracon Rep.: Jonathan Baze Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 TOTAL NUMBER OF CONCRETE CYLINDERS PICKED UP:5 Report No.:94141126.0088 No. of Cylinders:5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0093 07/22/14 07/29/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92 - 98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 95-1/+3296.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Interior Plumbing, Wastewater 2003 100' N & 5' W of SE corner of pad 2.2' BFG 1 6 118.3 27.2 29.9 91.1 95 2004 100' N & 5' W of SE corner of pad 1.4' BFG 1 6 119.1 27.8 30.4 91.3 95 2005 395' N & 100' W of SE corner of pad 5' BFG 1 6 118.2 27.4 30.2 90.8 94 2006 395' N & 100' W of SE corner of pad 4.2' BFG 1 6 118.3 27.3 30.0 91.0 95 2007 395' N & 100' W of SE corner of pad 3.4' BFG 1 6 118.4 27.2 29.8 91.2 95 2008 395' N & 100' W of SE corner of pad 2.6' BFG 1 6 118.3 27.4 30.1 90.9 94 2009 395' N & 100' W of SE corner of pad 1.8' BFG 1 6 118.8 27.7 30.4 91.1 95 2010 395' N & 100' W of SE corner of pad 1' BFG 1 6 118.9 27.6 30.2 91.3 95 Water Line, Line W-2 2011 Sta. 9+00 3' BFG 2 6 115.7 22.8 24.5 92.9 97 2012 Sta. 9+00 2.2' BFG 2 6 116.2 23.0 24.7 93.2 97 2013 Sta. 9+00 1.4' BFG 2 6 115.7 22.7 24.4 93.0 97 2014 Sta. 7+00 .6' BFG 2 6 116.1 23.1 24.8 93.0 97 2015 Sta. 7+00 3' BFG 2 6 115.6 22.8 24.6 92.8 96 2016 Sta. 7+00 2.2' BFG 2 6 116.7 23.3 24.9 93.4 97 2017 Sta. 7+00 1.4' BFG 2 6 116.8 23.1 24.7 93.7 97 2018 Sta. 7+00 .6' BFG 2 6 116.2 22.9 24.5 93.3 97 2019 Sta. 5+00 .3' BFG 2 6 115.9 22.9 24.6 93.0 97 2020 Sta. 5+00 2.2' BFG 2 6 116.6 22.8 24.3 93.8 98 2021 Sta. 5+00 1.4' BFG 2 6 116.7 23.1 24.7 93.6 97 2022 Sta. 5+00 .6' BFG 2 6 116.9 23.0 24.5 93.9 98 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0093 07/22/14 07/29/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Comments: Datum:BFG - Below Final Grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0094 07/23/14 07/29/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92 - 98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 95-2/+2286.830.294141126.0036 Lime treated dark and light brown clay ASTM D698 95-1/+3396.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Interior Plumbing, Wastewater 2023 375' N & 100' W of SE corner of pad 2' BFG 1 6 117.7 25.9 28.2 91.8 95 2024 375' N & 100' W of SE corner of pad Final 2 6 111.3 26.6 31.4 84.7 98 Water Line, Line W-2 2025 Sta. 3+00 3' BFG 3 6 117.4 23.3 24.8 94.1 98 2026 Sta. 3+00 2.2' BFG 3 6 117.0 23.1 24.6 93.9 98 2027 Sta. 3+00 1.4' BFG 3 6 117.7 23.5 24.9 94.2 98 2028 Sta. 3+00 .6' BFG 3 6 117.2 23.2 24.7 94.0 98 2029 Sta. 1+00 3' BFG 3 6 117.8 22.7 23.9 95.1 99 2030 Sta. 1+00 2.2' BFG 3 6 117.6 22.9 24.2 94.7 98 2031 Sta. 1+00 1.4' BFG 3 6 117.6 23.1 24.4 94.5 98 2032 Sta. 1+00 .6' BFG 3 6 117.6 22.8 24.1 94.8 99 Water Line, Line W-1 2033 Sta. 2+00 3' BFG 3 6 117.3 23.1 24.5 94.2 98 2034 Sta. 2+00 2.2' BFG 3 6 117.4 23.4 24.9 94.0 98 2035 Sta. 2+00 1.4' BFG 3 6 117.8 23.3 24.7 94.5 98 2036 Sta. 2+00 .6' BFG 3 6 117.3 23.0 24.4 94.3 98 2037 Sta. 4+00 3' BFG 3 6 117.2 22.6 23.9 94.6 98 2038 Sta. 4+00 2.2' BFG 3 6 117.7 22.9 24.2 94.8 99 2039 Sta. 4+00 1.4' BFG 3 6 117.2 22.7 24.0 94.5 98 2040 Sta. 4+00 .6' BFG 3 6 117.3 23.0 24.4 94.3 98 2041 Sta. 6+00 3' BFG 3 6 117.4 22.5 23.7 94.9 99 2042 Sta. 6+00 2.2' BFG 3 6 117.2 22.6 23.9 94.6 98 2043 Sta. 6+00 1.4' BFG 3 6 117.1 22.8 24.2 94.3 98 2044 Sta. 6+00 .6' BFG 3 6 117.2 22.7 24.0 94.5 98 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0094 07/23/14 07/29/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Comments: Datum:BFG - Below Final Grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 2 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0096 07/23/14 08/01/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 0822 1256 Plant: Ticket No.: P259 25901601 Field Test Data Test Air Content (%): Result Specification 5 1/4 5-7 1.1 0-3 92 87 149.9 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/23/14 1015 Jonathan Baze Clear, light winds 10/10 10 15 0 Piers G/2, & G/3Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0095, dated 07/23/14, for Pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/30/14 7 36,640 2 2,920 1 2 4.00 12.57 08/20/14 28 1 3 4.00 12.57 08/20/14 28 1 4 4.00 12.57 08/20/14 28 1 5 4.00 12.57 09/17/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0096 07/23/14 08/21/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 0822 1256 Plant: Ticket No.: P259 25901601 Field Test Data Test Air Content (%): Result Specification 5 1/4 5-7 1.1 0-3 92 87 149.9 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/23/14 1015 Jonathan Baze Clear, light winds 10/10 10 15 0 Piers G/2, & G/3Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0095, dated 07/23/14, for Pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/30/14 7 36,640 2 2,920 1 2 4.00 12.57 08/20/14 28 47,230 3 3,760 1 3 4.00 12.57 08/20/14 28 45,570 4 3,630 1 4 4.00 12.57 08/20/14 28 46,450 2 3,700 Average (28 days) 3,700 1 5 4.00 12.57 09/17/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0096 07/23/14 09/19/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 0822 1256 Plant: Ticket No.: P259 25901601 Field Test Data Test Air Content (%): Result Specification 5 1/4 5-7 1.1 0-3 92 87 149.9 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/23/14 1015 Jonathan Baze Clear, light winds 10/10 10 15 0 Piers G/2, & G/3Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0095, dated 07/23/14, for Pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/30/14 7 36,640 2 2,920 1 2 4.00 12.57 08/20/14 28 47,230 3 3,760 1 3 4.00 12.57 08/20/14 28 45,570 4 3,630 1 4 4.00 12.57 08/20/14 28 46,450 2 3,700 Average (28 days) 3,700 1 5 4.00 12.57 09/17/14 56 52,480 4 4,180 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 SAMPLE PICK-UP REPORT Report Number:94141126.0097 Service Date:07/23/14 8901 Carpenter Frwy., Suite 100 Report Date:07/25/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Concrete cylinder pickup. Terracon Rep.: Jonathan Baze Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 TOTAL NUMBER OF CONCRETE CYLINDERS PICKED UP:5 Report No.:94141126.0091 No. of Cylinders:5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0098 07/24/14 07/30/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 95-2/+2186.830.294141126.0036 Lime treated dark and light brown clay ASTM D698 92 - 98>/= +4296.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Interior Plumbing, Wastewater 2045 150' N & 10' W of SE corner of pad Final 1 6 110.7 25.9 30.6 84.8 98 2046 550' N & 10' W of SE corner of pad 8.0' BFG 2 6 118.2 26.5 28.9 91.7 95 2047 550' N & 10' W of SE corner of pad 7.2' BFG 2 6 118.1 26.8 29.3 91.3 95 2048 550' N & 10' W of SE corner of pad 6.4' BFG 2 6 117.4 26.4 29.0 91.0 95 2049 550' N & 10' W of SE corner of pad 5.6' BFG 2 6 117.7 26.3 28.8 91.4 95 2050 550' N & 10' W of SE corner of pad 4.8' BFG 2 6 118.3 26.7 29.1 91.6 95 2051 550' N & 10' W of SE corner of pad 4.0' BFG 2 6 118.0 26.8 29.4 91.2 95 2052 550' N & 10' W of SE corner of pad 3.2' BFG 2 6 118.2 26.7 29.2 91.5 95 Comments: Datum:BFG = Below Final Grade Serial No: Test and/or retest results on this report meet project requirements as noted above. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0098 07/24/14 07/30/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 2 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0100 07/24/14 08/04/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1108 1181 Plant: Ticket No.: 136 25902824 Field Test Data Test Air Content (%): Result Specification 6 1/4 5-7 0.8 91 85 148.4 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/24/14 1157 Jason Carrizales Clear 20/46 10 0 0 Pier @ L.4/1Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report No. 94141126.0099, date 07/24/14, for pier location Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/31/14 7 60,750 3 4,830 1 2 4.00 12.57 08/21/14 28 1 3 4.00 12.57 08/21/14 28 1 4 4.00 12.57 08/21/14 28 1 5 4.00 12.57 09/18/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jason Carrizales The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0100 07/24/14 08/22/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1108 1181 Plant: Ticket No.: 136 25902824 Field Test Data Test Air Content (%): Result Specification 6 1/4 5-7 0.8 91 85 148.4 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/24/14 1157 Jason Carrizales Clear 20/46 10 0 0 Pier @ L.4/1Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report No. 94141126.0099, date 07/24/14, for pier location Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/31/14 7 60,750 3 4,830 1 2 4.00 12.57 08/21/14 28 65,010 2 5,170 1 3 4.00 12.57 08/21/14 28 64,840 5 5,160 1 4 4.00 12.57 08/21/14 28 61,730 3 4,910 Average (28 days) 5,080 1 5 4.00 12.57 09/18/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jason Carrizales The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0100 07/24/14 09/19/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1108 1181 Plant: Ticket No.: 136 25902824 Field Test Data Test Air Content (%): Result Specification 6 1/4 5-7 0.8 91 85 148.4 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/24/14 1157 Jason Carrizales Clear 20/46 10 0 0 Pier @ L.4/1Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report No. 94141126.0099, date 07/24/14, for pier location Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 07/31/14 7 60,750 3 4,830 1 2 4.00 12.57 08/21/14 28 65,010 2 5,170 1 3 4.00 12.57 08/21/14 28 64,840 5 5,160 1 4 4.00 12.57 08/21/14 28 61,730 3 4,910 Average (28 days) 5,080 1 5 4.00 12.57 09/18/14 56 68,270 3 5,430 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jason Carrizales The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 SAMPLE PICK-UP REPORT Report Number:94141126.0101 Service Date:07/24/14 8901 Carpenter Frwy., Suite 100 Report Date:07/29/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Concrete cylinder pickup. Terracon Rep.: Jason Carrizales Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 TOTAL NUMBER OF CONCRETE CYLINDERS PICKED UP:5 Report No.:94141126.0096 No. of Cylinders:5 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0102 07/25/14 08/01/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 95-1/+3196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 92-98>/= +4296.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 95-2/+2386.830.294141126.0036 Lime treated dark and light brown clay ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Water Line W-1 2053 Sta. 8+00 3' BFG 1 6 117.7 23.3 24.7 94.4 98 2054 Sta. 8+00 2.2' BFG 1 6 117.7 23.5 24.9 94.2 98 2055 Sta. 8+00 1.4' BFG 1 6 117.7 23.2 24.5 94.5 98 2056 Sta. 8+00 6' BFG 1 6 118.3 23.6 24.9 94.7 98 2057 Sta. 10+00 3' BFG 1 6 117.7 23.8 25.3 93.9 98 2058 Sta. 10+00 2.2' BFG 1 6 117.1 23.4 25.0 93.7 97 2059 Sta. 10+00 1.4' BFG 1 6 117.3 23.3 24.8 94.0 98 2060 Sta. 10+00 6' BFG 1 6 117.3 23.5 25.1 93.8 98 Interior Plumbing, Wastewater 2061 550' N & 10' W of the SE corner of pad 2.4' BFG 2 6 118.3 26.9 29.4 91.4 95 2062 550' N & 10' W of the SE corner of pad 1.6' BFG 2 6 117.5 26.5 29.1 91.0 95 2063 550' N & 10' W of the SE corner of pad 0.8' BFG 2 6 118.1 26.3 28.7 91.8 95 2064 550' N & 10' W of the SE corner of pad Final 3 6 111.3 26.7 31.6 84.6 97 Comments: Datum:BFG = below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0102 07/25/14 08/01/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 2 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0104 07/25/14 08/05/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 0925 1390 Plant: Ticket No.: 259 25903700 Field Test Data Test Air Content (%): Result Specification 6 0.5 91 88 149.2 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/25/14 1100 Jason Carrizales 10/20 10 0 0 Pier @ C.5/4Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg B, Drilled Piers, see Foundation Observations Report No. 94141126.0103, dated 07/25/14, for pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/01/14 7 30,190 2 2,400 1 2 4.00 12.57 08/22/14 28 1 3 4.00 12.57 08/22/14 28 1 4 4.00 12.57 08/22/14 28 1 5 4.00 12.57 09/19/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jason Carrizales The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0104 07/25/14 08/25/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 0925 1390 Plant: Ticket No.: 259 25903700 Field Test Data Test Air Content (%): Result Specification 6 0.5 91 88 149.2 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/25/14 1100 Jason Carrizales 10/20 10 0 0 Pier @ C.5/4Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg B, Drilled Piers, see Foundation Observations Report No. 94141126.0103, dated 07/25/14, for pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/01/14 7 30,190 2 2,400 1 2 4.00 12.57 08/22/14 28 39,200 5 3,120 1 3 4.00 12.57 08/22/14 28 37,020 5 2,950 1 4 4.00 12.57 08/22/14 28 38,180 6 3,040 Average (28 days) 3,040 1 5 4.00 12.57 09/19/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jason Carrizales The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0104 07/25/14 09/19/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 0925 1390 Plant: Ticket No.: 259 25903700 Field Test Data Test Air Content (%): Result Specification 6 0.5 91 88 149.2 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/25/14 1100 Jason Carrizales 10/20 10 0 0 Pier @ C.5/4Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg B, Drilled Piers, see Foundation Observations Report No. 94141126.0103, dated 07/25/14, for pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/01/14 7 30,190 2 2,400 1 2 4.00 12.57 08/22/14 28 39,200 5 3,120 1 3 4.00 12.57 08/22/14 28 37,020 5 2,950 1 4 4.00 12.57 08/22/14 28 38,180 6 3,040 Average (28 days) 3,040 1 5 4.00 12.57 09/19/14 56 43,720 5 3,480 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jason Carrizales The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0107 07/28/14 08/05/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1607 1291 Plant: Ticket No.: 259 25905355 Field Test Data Test Air Content (%): Result Specification 6 1/4 5-7 1.0 0-3 92 93 149.1 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/28/14 1730 Jonathan Baze Clear, heavy winds 10/25 10 0 0 Piers @ A/2.1, 2.5, & 2.9Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report No. 94141126.0106, dated 07/28/14, for pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/04/14 7 44,380 5 3,530 1 2 4.00 12.57 08/25/14 28 1 3 4.00 12.57 08/25/14 28 1 4 4.00 12.57 08/25/14 28 1 5 4.00 12.57 09/22/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0107 07/28/14 08/26/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1607 1291 Plant: Ticket No.: 259 25905355 Field Test Data Test Air Content (%): Result Specification 6 1/4 5-7 1.0 0-3 92 93 149.1 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/28/14 1730 Jonathan Baze Clear, heavy winds 10/25 10 0 0 Piers @ A/2.1, 2.5, & 2.9Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report No. 94141126.0106, dated 07/28/14, for pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/04/14 7 44,380 5 3,530 1 2 4.00 12.57 08/25/14 28 52,900 3 4,210 1 3 4.00 12.57 08/25/14 28 53,350 2 4,250 1 4 4.00 12.57 08/25/14 28 55,690 1 4,430 Average (28 days) 4,300 1 5 4.00 12.57 09/22/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0107 07/28/14 09/23/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1607 1291 Plant: Ticket No.: 259 25905355 Field Test Data Test Air Content (%): Result Specification 6 1/4 5-7 1.0 0-3 92 93 149.1 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/28/14 1730 Jonathan Baze Clear, heavy winds 10/25 10 0 0 Piers @ A/2.1, 2.5, & 2.9Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report No. 94141126.0106, dated 07/28/14, for pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/04/14 7 44,380 5 3,530 1 2 4.00 12.57 08/25/14 28 52,900 3 4,210 1 3 4.00 12.57 08/25/14 28 53,350 2 4,250 1 4 4.00 12.57 08/25/14 28 55,690 1 4,430 Average (28 days) 4,300 1 5 4.00 12.57 09/22/14 56 58,460 2 4,650 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 REINFORCING STEEL OBSERVATIONS REPORT Report Number:94141126.0108 Service Date:07/28/14 8901 Carpenter Frwy., Suite 100 Report Date:08/05/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Reinforcing steel (rebar) placement observation. Terracon Rep.: Vincent Green Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940003, 07-01-12, Rev.0 Page 1 of 1 tp PROJECT DATA Drawings Utilized:Structural Sheets/Details: S2.2/Foundation Detail, dated 10/24/13 Locations/Items Observed:Building D, Slab-on-Grade @ A.2 – H/1.2 – 3 Test Method:Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT Placing Drawings Approved X Bar Length and Shape X Column Tie Spacing & Type Bar Size X Proper Bar Placement X Stirrup Spacing & Type Bar Grade X Properly Tied X Welded Splices Rebar Clean X Dowel Bars in Place Mechanical Splices Trash & Debris Removed X Proper Bar Supports X Lapped Splices X Number of Bars X Proper Cover/Clearance X Discrepancies/Comments: No discrepancies were noted at the time of this observation. Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0109 07/28/14 08/06/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0332 1267 Plant: Ticket No.: 136, 236 25904411 Field Test Data Test Air Content (%): Result Specification 4 3-5 1.7 0-3 95 85 152.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/28/14 0423 Vincent Green 40/750 10 20 0 A.5/2.7Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-H/1.2-3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/04/14 7 56,400 3 4,490 1 2 4.00 12.57 08/25/14 28 1 3 4.00 12.57 08/25/14 28 1 4 4.00 12.57 08/25/14 28 1 5 4.00 12.57 09/22/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0109 07/28/14 08/06/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0433 1423 Plant: Ticket No.: 136, 236 25904455 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.5 0-3 97 85 150.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/28/14 0507 Vincent Green 140/750 10 0 0 C.3/1.4Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-H/1.2-3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/04/14 7 51,120 5 4,070 2 2 4.00 12.57 08/25/14 28 2 3 4.00 12.57 08/25/14 28 2 4 4.00 12.57 08/25/14 28 2 5 4.00 12.57 09/22/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0109 07/28/14 08/06/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0527 1184 Plant: Ticket No.: 136, 236 25904490 Field Test Data Test Air Content (%): Result Specification 4 3-5 1.4 0-3 96 84 150.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/28/14 0626 Vincent Green 240/750 10 0 0 E.6/2.5Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-H/1.2-3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/04/14 7 48,710 1 3,880 3 2 4.00 12.57 08/25/14 28 3 3 4.00 12.57 08/25/14 28 3 4 4.00 12.57 08/25/14 28 3 5 4.00 12.57 09/22/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0109 07/28/14 08/06/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0616 1426 Plant: Ticket No.: 136, 236 25904531 Field Test Data Test Air Content (%): Result Specification 4 3-5 1.5 0-3 93 85 153.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/28/14 0716 Vincent Green 340/750 10 0 0 F.5/1.9Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-H/1.2-3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 08/04/14 7 55,410 2 4,410 4 2 4.00 12.57 08/25/14 28 4 3 4.00 12.57 08/25/14 28 4 4 4.00 12.57 08/25/14 28 4 5 4.00 12.57 09/22/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0109 07/28/14 08/06/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0745 1186 Plant: Ticket No.: 136, 236 25904639 Field Test Data Test Air Content (%): Result Specification 5 3-5 0.7 0-3 92 86 153.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/28/14 0904 Vincent Green 440/750 10 0 0 G/2.1Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-H/1.2-3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 08/04/14 7 52,150 2 4,150 5 2 4.00 12.57 08/25/14 28 5 3 4.00 12.57 08/25/14 28 5 4 4.00 12.57 08/25/14 28 5 5 4.00 12.57 09/22/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0109 07/28/14 08/06/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0932 1422 Plant: Ticket No.: 136, 236 25904835 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.2 0-3 95 90 152.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/28/14 1025 Vincent Green 540/640 10 10 0 G.9/2.2Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-H/1.2-3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 6 1 4.00 12.57 08/04/14 7 56,630 1 4,510 6 2 4.00 12.57 08/25/14 28 6 3 4.00 12.57 08/25/14 28 6 4 4.00 12.57 08/25/14 28 6 5 4.00 12.57 09/22/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0109 07/28/14 08/26/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0332 1267 Plant: Ticket No.: 136, 236 25904411 Field Test Data Test Air Content (%): Result Specification 4 3-5 1.7 0-3 95 85 152.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/28/14 0423 Vincent Green 40/750 10 20 0 A.5/2.7Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-H/1.2-3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/04/14 7 56,400 3 4,490 1 2 4.00 12.57 08/25/14 28 60,950 2 4,850 1 3 4.00 12.57 08/25/14 28 63,160 1 5,030 1 4 4.00 12.57 08/25/14 28 64,400 2 5,130 Average (28 days) 5,000 1 5 4.00 12.57 09/22/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0109 07/28/14 08/26/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0433 1423 Plant: Ticket No.: 136, 236 25904455 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.5 0-3 97 85 150.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/28/14 0507 Vincent Green 140/750 10 0 0 C.3/1.4Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-H/1.2-3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/04/14 7 51,120 5 4,070 2 2 4.00 12.57 08/25/14 28 62,400 3 4,970 2 3 4.00 12.57 08/25/14 28 62,000 2 4,930 2 4 4.00 12.57 08/25/14 28 61,520 2 4,900 Average (28 days) 4,930 2 5 4.00 12.57 09/22/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0109 07/28/14 08/26/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0527 1184 Plant: Ticket No.: 136, 236 25904490 Field Test Data Test Air Content (%): Result Specification 4 3-5 1.4 0-3 96 84 150.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/28/14 0626 Vincent Green 240/750 10 0 0 E.6/2.5Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-H/1.2-3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/04/14 7 48,710 1 3,880 3 2 4.00 12.57 08/25/14 28 61,850 3 4,920 3 3 4.00 12.57 08/25/14 28 61,350 2 4,880 3 4 4.00 12.57 08/25/14 28 58,070 3 4,620 Average (28 days) 4,810 3 5 4.00 12.57 09/22/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0109 07/28/14 08/26/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0616 1426 Plant: Ticket No.: 136, 236 25904531 Field Test Data Test Air Content (%): Result Specification 4 3-5 1.5 0-3 93 85 153.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/28/14 0716 Vincent Green 340/750 10 0 0 F.5/1.9Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-H/1.2-3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 08/04/14 7 55,410 2 4,410 4 2 4.00 12.57 08/25/14 28 64,190 2 5,110 4 3 4.00 12.57 08/25/14 28 67,210 3 5,350 4 4 4.00 12.57 08/25/14 28 54,490 2 4,340 Average (28 days) 4,930 4 5 4.00 12.57 09/22/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0109 07/28/14 08/26/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0745 1186 Plant: Ticket No.: 136, 236 25904639 Field Test Data Test Air Content (%): Result Specification 5 3-5 0.7 0-3 92 86 153.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/28/14 0904 Vincent Green 440/750 10 0 0 G/2.1Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-H/1.2-3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 08/04/14 7 52,150 2 4,150 5 2 4.00 12.57 08/25/14 28 62,860 3 5,000 5 3 4.00 12.57 08/25/14 28 58,010 2 4,620 5 4 4.00 12.57 08/25/14 28 60,530 3 4,820 Average (28 days) 4,810 5 5 4.00 12.57 09/22/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0109 07/28/14 08/26/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0932 1422 Plant: Ticket No.: 136, 236 25904835 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.2 0-3 95 90 152.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/28/14 1025 Vincent Green 540/640 10 10 0 G.9/2.2Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-H/1.2-3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 6 1 4.00 12.57 08/04/14 7 56,630 1 4,510 6 2 4.00 12.57 08/25/14 28 67,240 2 5,350 6 3 4.00 12.57 08/25/14 28 71,080 2 5,660 6 4 4.00 12.57 08/25/14 28 70,670 3 5,620 Average (28 days) 5,540 6 5 4.00 12.57 09/22/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0109 07/28/14 09/23/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0332 1267 Plant: Ticket No.: 136, 236 25904411 Field Test Data Test Air Content (%): Result Specification 4 3-5 1.7 0-3 95 85 152.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/28/14 0423 Vincent Green 40/750 10 20 0 A.5/2.7Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-H/1.2-3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/04/14 7 56,400 3 4,490 1 2 4.00 12.57 08/25/14 28 60,950 2 4,850 1 3 4.00 12.57 08/25/14 28 63,160 1 5,030 1 4 4.00 12.57 08/25/14 28 64,400 2 5,130 Average (28 days) 5,000 1 5 4.00 12.57 09/22/14 56 75,460 3 6,010 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0109 07/28/14 09/23/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0433 1423 Plant: Ticket No.: 136, 236 25904455 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.5 0-3 97 85 150.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/28/14 0507 Vincent Green 140/750 10 0 0 C.3/1.4Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-H/1.2-3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/04/14 7 51,120 5 4,070 2 2 4.00 12.57 08/25/14 28 62,400 3 4,970 2 3 4.00 12.57 08/25/14 28 62,000 2 4,930 2 4 4.00 12.57 08/25/14 28 61,520 2 4,900 Average (28 days) 4,930 2 5 4.00 12.57 09/22/14 56 71,790 4 5,710 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0109 07/28/14 09/23/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0527 1184 Plant: Ticket No.: 136, 236 25904490 Field Test Data Test Air Content (%): Result Specification 4 3-5 1.4 0-3 96 84 150.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/28/14 0626 Vincent Green 240/750 10 0 0 E.6/2.5Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-H/1.2-3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/04/14 7 48,710 1 3,880 3 2 4.00 12.57 08/25/14 28 61,850 3 4,920 3 3 4.00 12.57 08/25/14 28 61,350 2 4,880 3 4 4.00 12.57 08/25/14 28 58,070 3 4,620 Average (28 days) 4,810 3 5 4.00 12.57 09/22/14 56 62,920 3 5,010 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0109 07/28/14 09/23/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0616 1426 Plant: Ticket No.: 136, 236 25904531 Field Test Data Test Air Content (%): Result Specification 4 3-5 1.5 0-3 93 85 153.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/28/14 0716 Vincent Green 340/750 10 0 0 F.5/1.9Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-H/1.2-3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 08/04/14 7 55,410 2 4,410 4 2 4.00 12.57 08/25/14 28 64,190 2 5,110 4 3 4.00 12.57 08/25/14 28 67,210 3 5,350 4 4 4.00 12.57 08/25/14 28 54,490 2 4,340 Average (28 days) 4,930 4 5 4.00 12.57 09/22/14 56 74,580 4 5,940 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0109 07/28/14 09/23/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0745 1186 Plant: Ticket No.: 136, 236 25904639 Field Test Data Test Air Content (%): Result Specification 5 3-5 0.7 0-3 92 86 153.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/28/14 0904 Vincent Green 440/750 10 0 0 G/2.1Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-H/1.2-3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 08/04/14 7 52,150 2 4,150 5 2 4.00 12.57 08/25/14 28 62,860 3 5,000 5 3 4.00 12.57 08/25/14 28 58,010 2 4,620 5 4 4.00 12.57 08/25/14 28 60,530 3 4,820 Average (28 days) 4,810 5 5 4.00 12.57 09/22/14 56 70,960 5 5,650 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0109 07/28/14 09/23/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0932 1422 Plant: Ticket No.: 136, 236 25904835 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.2 0-3 95 90 152.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/28/14 1025 Vincent Green 540/640 10 10 0 G.9/2.2Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-H/1.2-3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 6 1 4.00 12.57 08/04/14 7 56,630 1 4,510 6 2 4.00 12.57 08/25/14 28 67,240 2 5,350 6 3 4.00 12.57 08/25/14 28 71,080 2 5,660 6 4 4.00 12.57 08/25/14 28 70,670 3 5,620 Average (28 days) 5,540 6 5 4.00 12.57 09/22/14 56 74,160 4 5,900 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 6CR0001, 11-16-12, Rev.6 REINFORCING STEEL OBSERVATIONS REPORT Report Number:94141126.0114 Service Date:07/29/14 8901 Carpenter Frwy., Suite 100 Report Date:08/05/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Reinforcing steel (rebar) placement observation. Terracon Rep.: Vincent Green Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940003, 07-01-12, Rev.0 Page 1 of 1 sbv PROJECT DATA Drawings Utilized:Sheets/Details: S2.2/Foundation Details, dated 10/24/13 Locations/Items Observed:Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Test Method:Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT Placing Drawings Approved X Bar Length and Shape X Column Tie Spacing & Type Bar Size X Proper Bar Placement X Stirrup Spacing & Type Bar Grade X Properly Tied X Welded Splices Rebar Clean X Dowel Bars in Place X Mechanical Splices Trash & Debris Removed X Proper Bar Supports X Lapped Splices X Number of Bars X Proper Cover/Clearance X Discrepancies/Comments: No discrepancies were noted at the time of this observation. Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 08/07/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0339 1426 Plant: Ticket No.: 136 25905437 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.6 1-3 87 75 152.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 0420 Vincent Green 40/570 10 0 0 H.5/1.7Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/05/14 7 56,880 2 4,530 1 2 4.00 12.57 08/26/14 28 1 3 4.00 12.57 08/26/14 28 1 4 4.00 12.57 08/26/14 28 1 5 4.00 12.57 09/23/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 08/07/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0425 1191 Plant: Ticket No.: 136 25905468 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.7 1-3 88 75 152.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 0507 Vincent Green 130/570 10 0 0 J/2.1Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/05/14 7 59,160 3 4,710 2 2 4.00 12.57 08/26/14 28 2 3 4.00 12.57 08/26/14 28 2 4 4.00 12.57 08/26/14 28 2 5 4.00 12.57 09/23/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 08/07/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0523 1186 Plant: Ticket No.: 136 25905526 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.2 1-3 88 73 153.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 0606 Vincent Green 230/570 10 0 0 K.9/2.8Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/05/14 7 56,110 2 4,470 3 2 4.00 12.57 08/26/14 28 3 3 4.00 12.57 08/26/14 28 3 4 4.00 12.57 08/26/14 28 3 5 4.00 12.57 09/23/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 08/07/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0624 1426 Plant: Ticket No.: 136 25905587 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.4 1-3 84 74 152.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 Vincent Green 340/570 10 0 0 M.1/1.5Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 08/05/14 7 60,580 4 4,820 4 2 4.00 12.57 08/26/14 28 4 3 4.00 12.57 08/26/14 28 4 4 4.00 12.57 08/26/14 28 4 5 4.00 12.57 09/23/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 08/07/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0732 1191 Plant: Ticket No.: 136 25905692 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.6 1-3 88 78 152.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 0826 Vincent Green 450/570 10 0 0 N.6/2.7Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 08/05/14 7 61,700 2 4,910 5 2 4.00 12.57 08/26/14 28 5 3 4.00 12.57 08/26/14 28 5 4 4.00 12.57 08/26/14 28 5 5 4.00 12.57 09/23/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 08/07/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0832 1185 Plant: Ticket No.: 136 25905764 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.5 1-3 89 80 151.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 0918 Vincent Green 530/570 10 0 0 O.5/2.8Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 6 1 4.00 12.57 08/05/14 7 54,420 2 4,330 6 2 4.00 12.57 08/26/14 28 6 3 4.00 12.57 08/26/14 28 6 4 4.00 12.57 08/26/14 28 6 5 4.00 12.57 09/23/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 08/26/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0339 1426 Plant: Ticket No.: 136 25905437 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.6 1-3 87 75 152.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 0420 Vincent Green 40/570 10 0 0 H.5/1.7Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/05/14 7 56,880 2 4,530 1 2 4.00 12.57 08/26/14 28 1 3 4.00 12.57 08/26/14 28 1 4 4.00 12.57 08/26/14 28 1 5 4.00 12.57 09/23/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 08/26/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0425 1191 Plant: Ticket No.: 136 25905468 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.7 1-3 88 75 152.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 0507 Vincent Green 130/570 10 0 0 J/2.1Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/05/14 7 59,160 3 4,710 2 2 4.00 12.57 08/26/14 28 2 3 4.00 12.57 08/26/14 28 2 4 4.00 12.57 08/26/14 28 2 5 4.00 12.57 09/23/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 08/26/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0523 1186 Plant: Ticket No.: 136 25905526 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.2 1-3 88 73 153.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 0606 Vincent Green 230/570 10 0 0 K.9/2.8Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/05/14 7 56,110 2 4,470 3 2 4.00 12.57 08/26/14 28 3 3 4.00 12.57 08/26/14 28 3 4 4.00 12.57 08/26/14 28 3 5 4.00 12.57 09/23/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 08/26/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0624 1426 Plant: Ticket No.: 136 25905587 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.4 1-3 84 74 152.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 Vincent Green 340/570 10 0 0 M.1/1.5Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 08/05/14 7 60,580 4 4,820 4 2 4.00 12.57 08/26/14 28 4 3 4.00 12.57 08/26/14 28 4 4 4.00 12.57 08/26/14 28 4 5 4.00 12.57 09/23/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 08/26/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0732 1191 Plant: Ticket No.: 136 25905692 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.6 1-3 88 78 152.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 0826 Vincent Green 450/570 10 0 0 N.6/2.7Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 08/05/14 7 61,700 2 4,910 5 2 4.00 12.57 08/26/14 28 5 3 4.00 12.57 08/26/14 28 5 4 4.00 12.57 08/26/14 28 5 5 4.00 12.57 09/23/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 08/26/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0832 1185 Plant: Ticket No.: 136 25905764 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.5 1-3 89 80 151.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 0918 Vincent Green 530/570 10 0 0 O.5/2.8Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 6 1 4.00 12.57 08/05/14 7 54,420 2 4,330 6 2 4.00 12.57 08/26/14 28 65,830 4 5,240 6 3 4.00 12.57 08/26/14 28 6 4 4.00 12.57 08/26/14 28 6 5 4.00 12.57 09/23/14 56 Comments:Compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 08/27/14 Revision 2 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0339 1426 Plant: Ticket No.: 136 25905437 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.6 1-3 87 75 152.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 0420 Vincent Green 40/570 10 0 0 H.5/1.7Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/05/14 7 56,880 2 4,530 1 2 4.00 12.57 08/26/14 28 65,540 4 5,220 1 3 4.00 12.57 08/26/14 28 70,590 4 5,620 1 4 4.00 12.57 08/26/14 28 67,870 2 5,400 Average (28 days) 5,410 1 5 4.00 12.57 09/23/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 08/27/14 Revision 2 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0425 1191 Plant: Ticket No.: 136 25905468 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.7 1-3 88 75 152.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 0507 Vincent Green 130/570 10 0 0 J/2.1Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/05/14 7 59,160 3 4,710 2 2 4.00 12.57 08/26/14 28 71,070 5 5,660 2 3 4.00 12.57 08/26/14 28 69,420 4 5,520 2 4 4.00 12.57 08/26/14 28 67,680 2 5,390 Average (28 days) 5,520 2 5 4.00 12.57 09/23/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 08/27/14 Revision 2 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0523 1186 Plant: Ticket No.: 136 25905526 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.2 1-3 88 73 153.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 0606 Vincent Green 230/570 10 0 0 K.9/2.8Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/05/14 7 56,110 2 4,470 3 2 4.00 12.57 08/26/14 28 73,260 3 5,830 3 3 4.00 12.57 08/26/14 28 67,120 2 5,340 3 4 4.00 12.57 08/26/14 28 67,420 5 5,370 Average (28 days) 5,510 3 5 4.00 12.57 09/23/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 08/27/14 Revision 2 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0624 1426 Plant: Ticket No.: 136 25905587 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.4 1-3 84 74 152.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 Vincent Green 340/570 10 0 0 M.1/1.5Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 08/05/14 7 60,580 4 4,820 4 2 4.00 12.57 08/26/14 28 70,900 2 5,640 4 3 4.00 12.57 08/26/14 28 68,880 4 5,480 4 4 4.00 12.57 08/26/14 28 69,590 3 5,540 Average (28 days) 5,550 4 5 4.00 12.57 09/23/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 08/27/14 Revision 2 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0732 1191 Plant: Ticket No.: 136 25905692 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.6 1-3 88 78 152.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 0826 Vincent Green 450/570 10 0 0 N.6/2.7Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 08/05/14 7 61,700 2 4,910 5 2 4.00 12.57 08/26/14 28 74,610 4 5,940 5 3 4.00 12.57 08/26/14 28 72,990 2 5,810 5 4 4.00 12.57 08/26/14 28 72,060 5 5,730 Average (28 days) 5,830 5 5 4.00 12.57 09/23/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 08/27/14 Revision 2 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0832 1185 Plant: Ticket No.: 136 25905764 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.5 1-3 89 80 151.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 0918 Vincent Green 530/570 10 0 0 O.5/2.8Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 6 1 4.00 12.57 08/05/14 7 54,420 2 4,330 6 2 4.00 12.57 08/26/14 28 65,830 4 5,240 6 3 4.00 12.57 08/26/14 28 65,640 3 5,220 6 4 4.00 12.57 08/26/14 28 62,750 5 4,990 Average (28 days) 5,150 6 5 4.00 12.57 09/23/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 09/24/14 Revision 3 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0339 1426 Plant: Ticket No.: 136 25905437 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.6 1-3 87 75 152.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 0420 Vincent Green 40/570 10 0 0 H.5/1.7Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/05/14 7 56,880 2 4,530 1 2 4.00 12.57 08/26/14 28 65,540 4 5,220 1 3 4.00 12.57 08/26/14 28 70,590 4 5,620 1 4 4.00 12.57 08/26/14 28 67,870 2 5,400 Average (28 days) 5,410 1 5 4.00 12.57 09/23/14 56 75,720 4 6,030 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 09/24/14 Revision 3 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0425 1191 Plant: Ticket No.: 136 25905468 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.7 1-3 88 75 152.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 0507 Vincent Green 130/570 10 0 0 J/2.1Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/05/14 7 59,160 3 4,710 2 2 4.00 12.57 08/26/14 28 71,070 5 5,660 2 3 4.00 12.57 08/26/14 28 69,420 4 5,520 2 4 4.00 12.57 08/26/14 28 67,680 2 5,390 Average (28 days) 5,520 2 5 4.00 12.57 09/23/14 56 80,300 3 6,390 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 09/24/14 Revision 3 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0523 1186 Plant: Ticket No.: 136 25905526 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.2 1-3 88 73 153.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 0606 Vincent Green 230/570 10 0 0 K.9/2.8Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/05/14 7 56,110 2 4,470 3 2 4.00 12.57 08/26/14 28 73,260 3 5,830 3 3 4.00 12.57 08/26/14 28 67,120 2 5,340 3 4 4.00 12.57 08/26/14 28 67,420 5 5,370 Average (28 days) 5,510 3 5 4.00 12.57 09/23/14 56 68,760 2 5,470 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 09/24/14 Revision 3 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0624 1426 Plant: Ticket No.: 136 25905587 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.4 1-3 84 74 152.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 Vincent Green 340/570 10 0 0 M.1/1.5Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 08/05/14 7 60,580 4 4,820 4 2 4.00 12.57 08/26/14 28 70,900 2 5,640 4 3 4.00 12.57 08/26/14 28 68,880 4 5,480 4 4 4.00 12.57 08/26/14 28 69,590 3 5,540 Average (28 days) 5,550 4 5 4.00 12.57 09/23/14 56 78,150 5 6,220 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 09/24/14 Revision 3 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0732 1191 Plant: Ticket No.: 136 25905692 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.6 1-3 88 78 152.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 0826 Vincent Green 450/570 10 0 0 N.6/2.7Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 08/05/14 7 61,700 2 4,910 5 2 4.00 12.57 08/26/14 28 74,610 4 5,940 5 3 4.00 12.57 08/26/14 28 72,990 2 5,810 5 4 4.00 12.57 08/26/14 28 72,060 5 5,730 Average (28 days) 5,830 5 5 4.00 12.57 09/23/14 56 75,270 2 5,990 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0115 07/29/14 09/24/14 Revision 3 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P225P1 Redi-Mix Material Information 0832 1185 Plant: Ticket No.: 136 25905764 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.5 1-3 89 80 151.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 0918 Vincent Green 530/570 10 0 0 O.5/2.8Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ H-O.9/1.2-3.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 6 1 4.00 12.57 08/05/14 7 54,420 2 4,330 6 2 4.00 12.57 08/26/14 28 65,830 4 5,240 6 3 4.00 12.57 08/26/14 28 65,640 3 5,220 6 4 4.00 12.57 08/26/14 28 62,750 5 4,990 Average (28 days) 5,150 6 5 4.00 12.57 09/23/14 56 69,320 2 5,520 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0118 07/29/14 08/07/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1612 1199 Plant: Ticket No.: 236 25906383 Field Test Data Test Air Content (%): Result Specification 6 5-7 1.1 0-3 88 84 151.2 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 1700 Jonathan Baze Cloudy, light winds 37/37 10 5 0 Piers E.4/1, & E.6/1Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0117, dated 07/29/14, for Pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/05/14 7 44,500 3 3,540 1 2 4.00 12.57 08/26/14 28 1 3 4.00 12.57 08/26/14 28 1 4 4.00 12.57 08/26/14 28 1 5 4.00 12.57 09/23/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0118 07/29/14 08/26/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1612 1199 Plant: Ticket No.: 236 25906383 Field Test Data Test Air Content (%): Result Specification 6 5-7 1.1 0-3 88 84 151.2 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 1700 Jonathan Baze Cloudy, light winds 37/37 10 5 0 Piers E.4/1, & E.6/1Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0117, dated 07/29/14, for Pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/05/14 7 44,500 3 3,540 1 2 4.00 12.57 08/26/14 28 55,500 5 4,420 1 3 4.00 12.57 08/26/14 28 54,010 5 4,300 1 4 4.00 12.57 08/26/14 28 58,700 4 4,670 Average (28 days) 4,460 1 5 4.00 12.57 09/23/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0118 07/29/14 09/24/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1612 1199 Plant: Ticket No.: 236 25906383 Field Test Data Test Air Content (%): Result Specification 6 5-7 1.1 0-3 88 84 151.2 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/29/14 1700 Jonathan Baze Cloudy, light winds 37/37 10 5 0 Piers E.4/1, & E.6/1Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0117, dated 07/29/14, for Pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/05/14 7 44,500 3 3,540 1 2 4.00 12.57 08/26/14 28 55,500 5 4,420 1 3 4.00 12.57 08/26/14 28 54,010 5 4,300 1 4 4.00 12.57 08/26/14 28 58,700 4 4,670 Average (28 days) 4,460 1 5 4.00 12.57 09/23/14 56 69,880 2 5,560 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0120 07/29/14 08/05/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 95-2/+2286.830.294141126.0036 Lime treated dark and light brown clay ASTM D698 95-1/+3396.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Interior Plumbing Bldg. C Wastewater 2072 200' N & 10' E of SW corner of pad 2' BFG 1 6 117.0 25.9 28.4 91.1 95 2073 200' N & 10' E of SW corner of pad 1.2' BFG 1 6 117.0 25.7 28.2 91.3 95 2074 200' N & 10' E of SW corner of pad 0.4' BFG 1 6 116.9 25.9 28.5 91.0 95 2075 200' N & 10' E of SW corner of pad Final 2 6 112.0 26.6 31.2 85.4 98 Storm Sewer Lot A-1 2076 Sta. 1+00 2' BFG 3 6 118.0 23.4 24.7 94.6 98 2077 Sta. 1+00 1.2' BFG 3 6 117.9 23.5 24.9 94.4 98 2078 Sta. 1+00 0.4' BFG 3 6 118.1 23.3 24.6 94.8 99 2079 Sta. 1+00 Final 3 6 118.2 23.7 25.1 94.5 98 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0120 07/29/14 08/05/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 2 REINFORCING STEEL OBSERVATIONS REPORT Report Number:94141126.0121 Service Date:07/30/14 8901 Carpenter Frwy., Suite 100 Report Date:08/06/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Reinforcing steel (rebar) placement observation. Terracon Rep.: Vincent Green Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940003, 07-01-12, Rev.0 Page 1 of 1 sbv PROJECT DATA Drawings Utilized:Structural Sheets/Details: S2.2/Foundation, dated 10/24/13 Locations/Items Observed:Building D, Slab-on-Grade @ A.2-E.5/3.0-4.8 Test Method:Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT Placing Drawings Approved X Bar Length and Shape X Column Tie Spacing & Type Bar Size X Proper Bar Placement X Stirrup Spacing & Type Bar Grade X Properly Tied X Welded Splices Rebar Clean X Dowel Bars in Place X Mechanical Splices Trash & Debris Removed X Proper Bar Supports X Lapped Splices X Number of Bars X Proper Cover/Clearance X Discrepancies/Comments: No discrepancies were noted at the time of this observation. Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0122 07/30/14 08/08/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0337 1183 Plant: Ticket No.: 259 25906457 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.4 0-3 89 75 148.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/30/14 0450 Vincent Green 50/240 10 0 0 A.3/5.5Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-E.5/3.0-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/06/14 7 56,700 2 4,510 1 2 4.00 12.57 08/27/14 28 1 3 4.00 12.57 08/27/14 28 1 4 4.00 12.57 08/27/14 28 1 5 4.00 12.57 09/24/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 3CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0122 07/30/14 08/08/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0450 1190 Plant: Ticket No.: 259 25906522 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.1 0-3 87 77 148.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/30/14 0535 Vincent Green 160/240 10 0 0 B.9/4.5Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-E.5/3.0-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/06/14 7 50,170 4 3,990 2 2 4.00 12.57 08/27/14 28 2 3 4.00 12.57 08/27/14 28 2 4 4.00 12.57 08/27/14 28 2 5 4.00 12.57 09/24/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 3CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0122 07/30/14 08/08/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0623 1287 Plant: Ticket No.: 259 25906606 Field Test Data Test Air Content (%): Result Specification 5 3-5 0.9 0-3 88 78 150.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/30/14 0713 Vincent Green 240/240 10 0 0 D.5/5.3Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-E.5/3.0-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/06/14 7 51,050 2 4,060 3 2 4.00 12.57 08/27/14 28 3 3 4.00 12.57 08/27/14 28 3 4 4.00 12.57 08/27/14 28 3 5 4.00 12.57 09/24/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 3CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0122 07/30/14 08/28/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0337 1183 Plant: Ticket No.: 259 25906457 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.4 0-3 89 75 148.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/30/14 0450 Vincent Green 50/240 10 0 0 A.3/5.5Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-E.5/3.0-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/06/14 7 56,700 2 4,510 1 2 4.00 12.57 08/27/14 28 71,180 4 5,660 1 3 4.00 12.57 08/27/14 28 72,300 2 5,750 1 4 4.00 12.57 08/27/14 28 69,230 3 5,510 Average (28 days) 5,640 1 5 4.00 12.57 09/24/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 3CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0122 07/30/14 08/28/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0450 1190 Plant: Ticket No.: 259 25906522 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.1 0-3 87 77 148.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/30/14 0535 Vincent Green 160/240 10 0 0 B.9/4.5Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-E.5/3.0-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/06/14 7 50,170 4 3,990 2 2 4.00 12.57 08/27/14 28 63,420 5 5,050 2 3 4.00 12.57 08/27/14 28 66,840 2 5,320 2 4 4.00 12.57 08/27/14 28 67,550 3 5,380 Average (28 days) 5,250 2 5 4.00 12.57 09/24/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 3CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0122 07/30/14 08/28/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0623 1287 Plant: Ticket No.: 259 25906606 Field Test Data Test Air Content (%): Result Specification 5 3-5 0.9 0-3 88 78 150.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/30/14 0713 Vincent Green 240/240 10 0 0 D.5/5.3Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-E.5/3.0-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/06/14 7 51,050 2 4,060 3 2 4.00 12.57 08/27/14 28 58,950 5 4,690 3 3 4.00 12.57 08/27/14 28 64,030 2 5,100 3 4 4.00 12.57 08/27/14 28 62,000 5 4,930 Average (28 days) 4,910 3 5 4.00 12.57 09/24/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 3CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0122 07/30/14 09/25/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0337 1183 Plant: Ticket No.: 259 25906457 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.4 0-3 89 75 148.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/30/14 0450 Vincent Green 50/240 10 0 0 A.3/5.5Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-E.5/3.0-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/06/14 7 56,700 2 4,510 1 2 4.00 12.57 08/27/14 28 71,180 4 5,660 1 3 4.00 12.57 08/27/14 28 72,300 2 5,750 1 4 4.00 12.57 08/27/14 28 69,230 3 5,510 Average (28 days) 5,640 1 5 4.00 12.57 09/24/14 56 77,610 3 6,180 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 3CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0122 07/30/14 09/25/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0450 1190 Plant: Ticket No.: 259 25906522 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.1 0-3 87 77 148.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/30/14 0535 Vincent Green 160/240 10 0 0 B.9/4.5Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-E.5/3.0-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/06/14 7 50,170 4 3,990 2 2 4.00 12.57 08/27/14 28 63,420 5 5,050 2 3 4.00 12.57 08/27/14 28 66,840 2 5,320 2 4 4.00 12.57 08/27/14 28 67,550 3 5,380 Average (28 days) 5,250 2 5 4.00 12.57 09/24/14 56 68,870 2 5,480 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 3CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0122 07/30/14 09/25/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0623 1287 Plant: Ticket No.: 259 25906606 Field Test Data Test Air Content (%): Result Specification 5 3-5 0.9 0-3 88 78 150.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/30/14 0713 Vincent Green 240/240 10 0 0 D.5/5.3Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab-on-Grade @ A.2-E.5/3.0-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/06/14 7 51,050 2 4,060 3 2 4.00 12.57 08/27/14 28 58,950 5 4,690 3 3 4.00 12.57 08/27/14 28 64,030 2 5,100 3 4 4.00 12.57 08/27/14 28 62,000 5 4,930 Average (28 days) 4,910 3 5 4.00 12.57 09/24/14 56 80,880 3 6,440 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 3CR0001, 11-16-12, Rev.6 FOUNDATION OBSERVATIONS REPORT Report Number:94141126.0124 Service Date:07/30/14 8901 Carpenter Frwy., Suite 100 Report Date:08/06/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Drilled belled (underreamed) pier observation. Terracon Rep.: Jonathan Baze Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 sbv On this date, Terracon's representative arrived at the above referenced job site as scheduled for drilled belled pier observation. After arriving at the job site, Terracon's representative was notified that the scheduled drilled belled pier observation was cancelled due to weather. Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0132 07/31/14 08/11/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1725 1426 Plant: Ticket No.: P136 25907617 Field Test Data Test Air Content (%): Result Specification 5 1/2 5-7 1.6 0-3 86 77 147.6 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/31/14 1800 Jonathan Baze Cloudy, windy 50/50 10 0 0 Piers G/2.2, & G/2.5Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0131, dated 07/31/14, for pier information Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/07/14 7 29,650 2 2,360 1 2 4.00 12.57 08/28/14 28 1 3 4.00 12.57 08/28/14 28 1 4 4.00 12.57 08/28/14 28 1 5 4.00 12.57 09/25/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0132 07/31/14 08/29/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1725 1426 Plant: Ticket No.: P136 25907617 Field Test Data Test Air Content (%): Result Specification 5 1/2 5-7 1.6 0-3 86 77 147.6 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/31/14 1800 Jonathan Baze Cloudy, windy 50/50 10 0 0 Piers G/2.2, & G/2.5Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0131, dated 07/31/14, for pier information Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/07/14 7 29,650 2 2,360 1 2 4.00 12.57 08/28/14 28 44,440 5 3,540 1 3 4.00 12.57 08/28/14 28 43,100 2 3,430 1 4 4.00 12.57 08/28/14 28 46,680 6 3,720 Average (28 days) 3,560 1 5 4.00 12.57 09/25/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0132 07/31/14 09/25/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1725 1426 Plant: Ticket No.: P136 25907617 Field Test Data Test Air Content (%): Result Specification 5 1/2 5-7 1.6 0-3 86 77 147.6 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:07/31/14 1800 Jonathan Baze Cloudy, windy 50/50 10 0 0 Piers G/2.2, & G/2.5Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observation Report #94141126.0131, dated 07/31/14, for pier information Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/07/14 7 29,650 2 2,360 1 2 4.00 12.57 08/28/14 28 44,440 5 3,540 1 3 4.00 12.57 08/28/14 28 43,100 2 3,430 1 4 4.00 12.57 08/28/14 28 46,680 6 3,720 Average (28 days) 3,560 1 5 4.00 12.57 09/25/14 56 54,690 4 4,350 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0134 07/31/14 08/04/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 95-2/+2286.830.294141126.0036 Lime treated dark and light brown clay ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Interior Plumbing, Bldg. C, Wastewater 2065 240' N & 100' E of SW corner of pad 3' BFG 1 6 118.0 27.5 30.4 90.5 94 2066 240' N & 100' E of SW corner of pad 2.2' BFG 1 6 118.6 27.9 30.8 90.7 94 2067 240' N & 100' E of SW corner of pad 1.4' BFG 1 6 118.1 27.7 30.6 90.4 94 2068 240' N & 100' E of SW corner of pad 0.6' BFG 1 6 118.1 27.5 30.3 90.6 94 2069 240' N & 100' E of SW corner of pad Final 2 6 111.2 26.4 31.1 84.8 98 2070 400' N & 15' E of SW corner of pad 3' BFG 1 6 119.2 28.1 30.9 91.1 95 2071 400' N & 15' E of SW corner of pad 2.2' BFG 1 6 118.2 27.4 30.2 90.8 94 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 1 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0137 08/01/14 08/11/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 0937 1420 Plant: Ticket No.: 136 25908137 Field Test Data Test Air Content (%): Result Specification 6 5-7 1.2 0-3 84 72 152.8 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/01/14 1045 Jonathan Baze Cloudy, windy 10/40 10 0 0 Piers @ G/3.8, G/4, E.2/4Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report No. 94141126.0136, dated 08/01/14 for pier locations; Bldg C, Pier Caps @ G/2 & G/3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/08/14 7 42,800 3 3,410 1 2 4.00 12.57 08/29/14 28 1 3 4.00 12.57 08/29/14 28 1 4 4.00 12.57 08/29/14 28 1 5 4.00 12.57 09/26/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0137 08/01/14 09/02/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 0937 1420 Plant: Ticket No.: 136 25908137 Field Test Data Test Air Content (%): Result Specification 6 5-7 1.2 0-3 84 72 152.8 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/01/14 1045 Jonathan Baze Cloudy, windy 10/40 10 0 0 Piers @ G/3.8, G/4, E.2/4Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report No. 94141126.0136, dated 08/01/14 for pier locations; Bldg C, Pier Caps @ G/2 & G/3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/08/14 7 42,800 3 3,410 1 2 4.00 12.57 08/29/14 28 54,740 2 4,360 1 3 4.00 12.57 08/29/14 28 51,400 4 4,090 1 4 4.00 12.57 08/29/14 28 55,740 2 4,440 Average (28 days) 4,300 1 5 4.00 12.57 09/26/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0137 08/01/14 09/29/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 0937 1420 Plant: Ticket No.: 136 25908137 Field Test Data Test Air Content (%): Result Specification 6 5-7 1.2 0-3 84 72 152.8 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/01/14 1045 Jonathan Baze Cloudy, windy 10/40 10 0 0 Piers @ G/3.8, G/4, E.2/4Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report No. 94141126.0136, dated 08/01/14 for pier locations; Bldg C, Pier Caps @ G/2 & G/3 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/08/14 7 42,800 3 3,410 1 2 4.00 12.57 08/29/14 28 54,740 2 4,360 1 3 4.00 12.57 08/29/14 28 51,400 4 4,090 1 4 4.00 12.57 08/29/14 28 55,740 2 4,440 Average (28 days) 4,300 1 5 4.00 12.57 09/26/14 56 66,590 5 5,300 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0139 08/01/14 08/06/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 95-2/+2286.830.294141126.0036 Lime treated dark and light brown clay ASTM D698 95-1/+3396.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Interior Plumbing Bldg. C 2080 400' N & 15' E of SW corner of pad 1.4' BFG 1 6 118.2 26.5 28.9 91.7 95 2081 400' N & 15' E of SW corner of pad 0.6' BFG 1 6 118.2 26.8 29.3 91.4 95 2082 400' N & 15' E of SW corner of pad Final 2 6 111.7 26.5 31.1 85.2 98 Water Fire Riser 2083 375' N & 30' W of SW corner of Bldg. D 3' BFG 3 6 117.7 23.4 24.8 94.3 98 2084 375' N & 30' W of SW corner of Bldg. D 2.2' BFG 3 6 117.0 23.0 24.5 94.0 98 2085 375' N & 30' W of SW corner of Bldg. D 1.4' BFG 3 6 117.7 23.3 24.7 94.4 98 2086 375' N & 30' W of SW corner of Bldg. D 0.6' BFG 3 6 117.5 23.4 24.9 94.1 98 2087 375' N & 30' W of SW corner of Bldg. D Final 3 6 117.9 23.2 24.5 94.7 98 2088 575' N & 30' W of SW corner of Bldg. D 3' BFG 3 6 117.8 23.6 25.0 94.2 98 2089 575' N & 30' W of SW corner of Bldg. D 2.2' BFG 3 6 118.1 23.5 24.8 94.6 98 2090 575' N & 30' W of SW corner of Bldg. D 1.4' BFG 3 6 118.2 23.4 24.7 94.8 99 2091 575' N & 30' W of SW corner of Bldg. D 0.6' BFG 3 6 118.2 23.7 25.1 94.5 98 2092 575' N & 30' W of SW corner of Bldg. D Final 3 6 118.3 23.6 24.9 94.7 98 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0139 08/01/14 08/06/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 2 REINFORCING STEEL OBSERVATIONS REPORT Report Number:94141126.0140 Service Date:08/01/14 8901 Carpenter Frwy., Suite 100 Report Date:08/06/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Reinforcing steel (rebar) placement observation. Terracon Rep.: Jonathan Baze Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940003, 07-01-12, Rev.0 Page 1 of 1 tp PROJECT DATA Drawings Utilized:Structural Sheets/Details: S2.1/Concrete Note, dated 10/24/13 Locations/Items Observed:Building D, Slab-on-Grade @ A.1 – M/3.0 – 4.9 Test Method:Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT Placing Drawings Approved X Bar Length and Shape X Column Tie Spacing & Type Bar Size X Proper Bar Placement X Stirrup Spacing & Type Bar Grade X Properly Tied X Welded Splices Rebar Clean X Dowel Bars in Place X Mechanical Splices Trash & Debris Removed X Proper Bar Supports X Lapped Splices Number of Bars X Proper Cover/Clearance X Discrepancies/Comments: No discrepancies were noted at the time of this observation. Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0141 08/02/14 08/12/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0342 1185 Plant: Ticket No.:25908715 Field Test Data Test Air Content (%): Result Specification 5 3-5 0.9 0-3 85 69 152.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/02/14 0431 Vincent Green 40/700 10 10 0 E.6/3.2Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ E.5-K.5/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/09/14 7 53,650 5 4,270 1 2 4.00 12.57 08/30/14 28 1 3 4.00 12.57 08/30/14 28 1 4 4.00 12.57 08/30/14 28 1 5 4.00 12.57 09/27/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0141 08/02/14 08/12/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0437 1413 Plant: Ticket No.:25908731 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.9 0-3 87 69 148.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/02/14 0536 Vincent Green 130/700 10 0 0 F.5/4Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ E.5-K.5/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/09/14 7 52,040 4 4,140 2 2 4.00 12.57 08/30/14 28 2 3 4.00 12.57 08/30/14 28 2 4 4.00 12.57 08/30/14 28 2 5 4.00 12.57 09/27/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0141 08/02/14 08/12/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0543 1184 Plant: Ticket No.:25908753 Field Test Data Test Air Content (%): Result Specification 5 3-5 0.4 0-3 83 68 151.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/02/14 0630 Vincent Green 230/700 10 0 0 G.1/4.4Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ E.5-K.5/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/09/14 7 64,560 5 5,140 3 2 4.00 12.57 08/30/14 28 3 3 4.00 12.57 08/30/14 28 3 4 4.00 12.57 08/30/14 28 3 5 4.00 12.57 09/27/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0141 08/02/14 08/12/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0654 1429 Plant: Ticket No.:25908782 Field Test Data Test Air Content (%): Result Specification 4 3-5 0.7 0-3 84 68 150.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/02/14 0735 Vincent Green 330/700 10 0 0 H.5/3.3Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ E.5-K.5/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 08/09/14 7 55,650 2 4,430 4 2 4.00 12.57 08/30/14 28 4 3 4.00 12.57 08/30/14 28 4 4 4.00 12.57 08/30/14 28 4 5 4.00 12.57 09/27/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0141 08/02/14 08/12/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0804 1237 Plant: Ticket No.:25908826 Field Test Data Test Air Content (%): Result Specification 4 3-5 0.1 0-3 89 71 153.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/02/14 Vincent Green 430/700 10 10 0 I.9/4.1Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ E.5-K.5/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 08/09/14 7 47,850 5 3,810 5 2 4.00 12.57 08/30/14 28 5 3 4.00 12.57 08/30/14 28 5 4 4.00 12.57 08/30/14 28 5 5 4.00 12.57 09/27/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0141 08/02/14 08/12/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0909 1413 Plant: Ticket No.:25908889 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 0.3 0-3 90 75 152.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/02/14 1020 Vincent Green 540/700 10 0 0 J.7/3.9Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ E.5-K.5/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 6 1 4.00 12.57 08/09/14 7 50,880 3 4,050 6 2 4.00 12.57 08/30/14 28 6 3 4.00 12.57 08/30/14 28 6 4 4.00 12.57 08/30/14 28 6 5 4.00 12.57 09/27/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0141 08/02/14 09/02/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0342 1185 Plant: Ticket No.:25908715 Field Test Data Test Air Content (%): Result Specification 5 3-5 0.9 0-3 85 69 152.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/02/14 0431 Vincent Green 40/700 10 10 0 E.6/3.2Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ E.5-K.5/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/09/14 7 53,650 5 4,270 1 2 4.00 12.57 08/30/14 28 67,220 4 5,350 1 3 4.00 12.57 08/30/14 28 64,900 2 5,170 1 4 4.00 12.57 08/30/14 28 69,250 2 5,510 Average (28 days) 5,340 1 5 4.00 12.57 09/27/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0141 08/02/14 09/02/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0437 1413 Plant: Ticket No.:25908731 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.9 0-3 87 69 148.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/02/14 0536 Vincent Green 130/700 10 0 0 F.5/4Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ E.5-K.5/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/09/14 7 52,040 4 4,140 2 2 4.00 12.57 08/30/14 28 64,660 4 5,150 2 3 4.00 12.57 08/30/14 28 67,970 3 5,410 2 4 4.00 12.57 08/30/14 28 65,640 5 5,220 Average (28 days) 5,260 2 5 4.00 12.57 09/27/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0141 08/02/14 09/02/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0543 1184 Plant: Ticket No.:25908753 Field Test Data Test Air Content (%): Result Specification 5 3-5 0.4 0-3 83 68 151.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/02/14 0630 Vincent Green 230/700 10 0 0 G.1/4.4Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ E.5-K.5/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/09/14 7 64,560 5 5,140 3 2 4.00 12.57 08/30/14 28 68,240 4 5,430 3 3 4.00 12.57 08/30/14 28 68,890 2 5,480 3 4 4.00 12.57 08/30/14 28 65,960 5 5,250 Average (28 days) 5,390 3 5 4.00 12.57 09/27/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0141 08/02/14 09/02/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0654 1429 Plant: Ticket No.:25908782 Field Test Data Test Air Content (%): Result Specification 4 3-5 0.7 0-3 84 68 150.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/02/14 0735 Vincent Green 330/700 10 0 0 H.5/3.3Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ E.5-K.5/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 08/09/14 7 55,650 2 4,430 4 2 4.00 12.57 08/30/14 28 66,550 4 5,300 4 3 4.00 12.57 08/30/14 28 72,430 2 5,760 4 4 4.00 12.57 08/30/14 28 69,570 3 5,540 Average (28 days) 5,530 4 5 4.00 12.57 09/27/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0141 08/02/14 09/02/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0804 1237 Plant: Ticket No.:25908826 Field Test Data Test Air Content (%): Result Specification 4 3-5 0.1 0-3 89 71 153.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/02/14 Vincent Green 430/700 10 10 0 I.9/4.1Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ E.5-K.5/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 08/09/14 7 47,850 5 3,810 5 2 4.00 12.57 08/30/14 28 62,030 4 4,940 5 3 4.00 12.57 08/30/14 28 60,840 5 4,840 5 4 4.00 12.57 08/30/14 28 58,420 3 4,650 Average (28 days) 4,810 5 5 4.00 12.57 09/27/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0141 08/02/14 09/02/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0909 1413 Plant: Ticket No.:25908889 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 0.3 0-3 90 75 152.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/02/14 1020 Vincent Green 540/700 10 0 0 J.7/3.9Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ E.5-K.5/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 6 1 4.00 12.57 08/09/14 7 50,880 3 4,050 6 2 4.00 12.57 08/30/14 28 64,470 2 5,130 6 3 4.00 12.57 08/30/14 28 62,200 3 4,950 6 4 4.00 12.57 08/30/14 28 62,580 4 4,980 Average (28 days) 5,020 6 5 4.00 12.57 09/27/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0141 08/02/14 09/30/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0342 1185 Plant: Ticket No.:25908715 Field Test Data Test Air Content (%): Result Specification 5 3-5 0.9 0-3 85 69 152.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/02/14 0431 Vincent Green 40/700 10 10 0 E.6/3.2Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ E.5-K.5/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/09/14 7 53,650 5 4,270 1 2 4.00 12.57 08/30/14 28 67,220 4 5,350 1 3 4.00 12.57 08/30/14 28 64,900 2 5,170 1 4 4.00 12.57 08/30/14 28 69,250 2 5,510 Average (28 days) 5,340 1 5 4.00 12.57 09/27/14 56 79,700 3 6,340 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0141 08/02/14 09/30/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0437 1413 Plant: Ticket No.:25908731 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.9 0-3 87 69 148.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/02/14 0536 Vincent Green 130/700 10 0 0 F.5/4Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ E.5-K.5/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/09/14 7 52,040 4 4,140 2 2 4.00 12.57 08/30/14 28 64,660 4 5,150 2 3 4.00 12.57 08/30/14 28 67,970 3 5,410 2 4 4.00 12.57 08/30/14 28 65,640 5 5,220 Average (28 days) 5,260 2 5 4.00 12.57 09/27/14 56 73,090 2 5,820 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0141 08/02/14 09/30/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0543 1184 Plant: Ticket No.:25908753 Field Test Data Test Air Content (%): Result Specification 5 3-5 0.4 0-3 83 68 151.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/02/14 0630 Vincent Green 230/700 10 0 0 G.1/4.4Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ E.5-K.5/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/09/14 7 64,560 5 5,140 3 2 4.00 12.57 08/30/14 28 68,240 4 5,430 3 3 4.00 12.57 08/30/14 28 68,890 2 5,480 3 4 4.00 12.57 08/30/14 28 65,960 5 5,250 Average (28 days) 5,390 3 5 4.00 12.57 09/27/14 56 72,520 2 5,770 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0141 08/02/14 09/30/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0654 1429 Plant: Ticket No.:25908782 Field Test Data Test Air Content (%): Result Specification 4 3-5 0.7 0-3 84 68 150.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/02/14 0735 Vincent Green 330/700 10 0 0 H.5/3.3Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ E.5-K.5/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 08/09/14 7 55,650 2 4,430 4 2 4.00 12.57 08/30/14 28 66,550 4 5,300 4 3 4.00 12.57 08/30/14 28 72,430 2 5,760 4 4 4.00 12.57 08/30/14 28 69,570 3 5,540 Average (28 days) 5,530 4 5 4.00 12.57 09/27/14 56 73,570 3 5,860 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0141 08/02/14 09/30/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0804 1237 Plant: Ticket No.:25908826 Field Test Data Test Air Content (%): Result Specification 4 3-5 0.1 0-3 89 71 153.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/02/14 Vincent Green 430/700 10 10 0 I.9/4.1Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ E.5-K.5/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 08/09/14 7 47,850 5 3,810 5 2 4.00 12.57 08/30/14 28 62,030 4 4,940 5 3 4.00 12.57 08/30/14 28 60,840 5 4,840 5 4 4.00 12.57 08/30/14 28 58,420 3 4,650 Average (28 days) 4,810 5 5 4.00 12.57 09/27/14 56 70,540 3 5,610 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0141 08/02/14 09/30/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0909 1413 Plant: Ticket No.:25908889 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 0.3 0-3 90 75 152.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/02/14 1020 Vincent Green 540/700 10 0 0 J.7/3.9Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ E.5-K.5/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 6 1 4.00 12.57 08/09/14 7 50,880 3 4,050 6 2 4.00 12.57 08/30/14 28 64,470 2 5,130 6 3 4.00 12.57 08/30/14 28 62,200 3 4,950 6 4 4.00 12.57 08/30/14 28 62,580 4 4,980 Average (28 days) 5,020 6 5 4.00 12.57 09/27/14 56 75,620 2 6,020 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 6CR0001, 11-16-12, Rev.6 GRADATION REPORT Report Number:94141126.0143 Service Date:08/02/14 8901 Carpenter Frwy., Suite 100 Report Date:08/06/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Perform gradation tests on lime stabilized soil. Terracon Rep.: Armando Rendon Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CT0001, 9-28-10, Rev.8 Page 1 of 1 dgr SERVICES:SPECIFICATION REQUIREMENTS: Minimum Passing 1 3/4” Sieve (%):100 Performed gradation tests on lime treated soil. Minimum Passing #4 Sieve (%): 60 Sample Condition: Field Moist TEST LOCATION:Fire Lane, W of Bldg. D TEST NO.LOCATION 1 3/4” SIEVE % PASSING #4 SIEVE % PASSING 1 50’ N & 20’ W of SE corner 100 65 2 150’ N & 10’ W of SE corner 100 63 3 250’ N & 30’ W of SE corner 100 65 4 350’ N & 20’ W of SE corner 100 65 5 450’ N & 10’ W of SE corner 100 64 6 550’ N & 30’ W of SE corner 100 65 7 650’ N & 20’ W of SE corner 100 64 8 700’ N & 10’ W of SE corner 100 63 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0144 08/04/14 08/12/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 95-1/+3186.830.294141126.0036 Lime treated dark and light brown clay ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Fire Lane W of Bldg. D 2093 50' N & 20' W of SE corner Final 1 6 111.0 26.8 31.8 84.2 97 2094 150' N & 10' W of SE corner Final 1 6 109.9 26.2 31.3 83.7 96 2095 250' N & 30' W of SE corner Final 1 6 109.9 26.4 31.6 83.5 96 2096 350' N & 20' W of SE corner Final 1 6 111.0 27.0 32.2 84.0 97 2097 450' N & 10' W of SE cornre Final 1 6 110.6 26.8 32.0 83.8 97 2098 550' N & 30' W of SE corner Final 1 6 110.1 26.5 31.7 83.6 96 2099 650' N & 20' W of SE corner Final 1 6 110.4 26.8 32.0 83.6 96 2100 700' N & 10' W of SE corner Final 1 6 110.3 26.2 31.2 84.1 97 Comments: Datum:Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 1 REINFORCING STEEL OBSERVATIONS REPORT Report Number:94141126.0145 Service Date:08/04/14 8901 Carpenter Frwy., Suite 100 Report Date:08/12/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Reinforcing steel (rebar) placement observation. Terracon Rep.: Daniel Duran Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940003, 07-01-12, Rev.0 Page 1 of 1 tp PROJECT DATA Drawings Utilized:Structural Sheets/Details: S2.2/Building D, 01 Foundation Plan, dated 10/24/13 Locations/Items Observed:Building D, Slab-on-Grade @ K.5 – 0.9/3 – 4.8 Test Method:Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT Placing Drawings Approved X Bar Length and Shape X Column Tie Spacing & Type Bar Size X Proper Bar Placement X Stirrup Spacing & Type Bar Grade X Properly Tied X Welded Splices Rebar Clean X Dowel Bars in Place X Mechanical Splices Trash & Debris Removed X Proper Bar Supports X Lapped Splices X Number of Bars X Proper Cover/Clearance X Discrepancies/Comments: No discrepancies were noted at the time of this observation. Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0146 08/04/14 08/13/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0417 1425 Plant: Ticket No.: P136 25909031 Field Test Data Test Air Content (%): Result Specification 3 3/4 3-5 1.1 0-3 87 77 151.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/04/14 0455 Daniel Duran Clear 80/330 10 0 0 O.7/4.8Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ K.5-O.9/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/11/14 7 60,620 3 4,820 1 2 4.00 12.57 09/01/14 28 1 3 4.00 12.57 09/01/14 28 1 4 4.00 12.57 09/01/14 28 1 5 4.00 12.57 09/29/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0146 08/04/14 08/13/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0451 1176 Plant: Ticket No.: P136 25909066 Field Test Data Test Air Content (%): Result Specification 4 1/4 3-5 1.4 0-3 88 76 151.3 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/04/14 0540 Daniel Duran Clear 150/330 10 0 0 N.4/4.7Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ K.5-O.9/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/11/14 7 60,430 2 4,810 2 2 4.00 12.57 09/01/14 28 2 3 4.00 12.57 09/01/14 28 2 4 4.00 12.57 09/01/14 28 2 5 4.00 12.57 09/29/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0146 08/04/14 08/13/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0616 1452 Plant: Ticket No.: P136 25909132 Field Test Data Test Air Content (%): Result Specification 4 1/4 3-5 1.6 0-3 86 76 150.1 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/04/14 0707 Daniel Duran Clear 250/330 10 0 0 M/3.2Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ K.5-O.9/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/11/14 7 54,720 4 4,350 3 2 4.00 12.57 09/01/14 28 3 3 4.00 12.57 09/01/14 28 3 4 4.00 12.57 09/01/14 28 3 5 4.00 12.57 09/29/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0146 08/04/14 08/13/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0700 1176 Plant: Ticket No.: P136 25909199 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 1.2 0-3 88 76 150.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/04/14 0750 Daniel Duran Clear 300/330 10 10 0 L.2/3.9Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ K.5-O.9/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 08/11/14 7 53,210 5 4,230 4 2 4.00 12.57 09/01/14 28 4 3 4.00 12.57 09/01/14 28 4 4 4.00 12.57 09/01/14 28 4 5 4.00 12.57 09/29/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0146 08/04/14 09/03/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0417 1425 Plant: Ticket No.: P136 25909031 Field Test Data Test Air Content (%): Result Specification 3 3/4 3-5 1.1 0-3 87 77 151.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/04/14 0455 Daniel Duran Clear 80/330 10 0 0 O.7/4.8Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ K.5-O.9/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/11/14 7 60,620 3 4,820 1 2 4.00 12.57 09/01/14 28 72,970 2 5,810 1 3 4.00 12.57 09/01/14 28 70,140 3 5,580 1 4 4.00 12.57 09/01/14 28 72,800 2 5,790 Average (28 days) 5,730 1 5 4.00 12.57 09/29/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0146 08/04/14 09/03/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0451 1176 Plant: Ticket No.: P136 25909066 Field Test Data Test Air Content (%): Result Specification 4 1/4 3-5 1.4 0-3 88 76 151.3 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/04/14 0540 Daniel Duran Clear 150/330 10 0 0 N.4/4.7Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ K.5-O.9/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/11/14 7 60,430 2 4,810 2 2 4.00 12.57 09/01/14 28 71,610 2 5,700 2 3 4.00 12.57 09/01/14 28 68,860 2 5,480 2 4 4.00 12.57 09/01/14 28 70,750 3 5,630 Average (28 days) 5,600 2 5 4.00 12.57 09/29/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0146 08/04/14 09/03/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0616 1452 Plant: Ticket No.: P136 25909132 Field Test Data Test Air Content (%): Result Specification 4 1/4 3-5 1.6 0-3 86 76 150.1 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/04/14 0707 Daniel Duran Clear 250/330 10 0 0 M/3.2Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ K.5-O.9/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/11/14 7 54,720 4 4,350 3 2 4.00 12.57 09/01/14 28 70,160 3 5,580 3 3 4.00 12.57 09/01/14 28 69,400 2 5,520 3 4 4.00 12.57 09/01/14 28 70,160 2 5,580 Average (28 days) 5,560 3 5 4.00 12.57 09/29/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0146 08/04/14 09/03/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0700 1176 Plant: Ticket No.: P136 25909199 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 1.2 0-3 88 76 150.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/04/14 0750 Daniel Duran Clear 300/330 10 10 0 L.2/3.9Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ K.5-O.9/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 08/11/14 7 53,210 5 4,230 4 2 4.00 12.57 09/01/14 28 68,410 3 5,440 4 3 4.00 12.57 09/01/14 28 68,700 2 5,470 4 4 4.00 12.57 09/01/14 28 68,660 4 5,460 Average (28 days) 5,460 4 5 4.00 12.57 09/29/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0146 08/04/14 09/30/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0417 1425 Plant: Ticket No.: P136 25909031 Field Test Data Test Air Content (%): Result Specification 3 3/4 3-5 1.1 0-3 87 77 151.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/04/14 0455 Daniel Duran Clear 80/330 10 0 0 O.7/4.8Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ K.5-O.9/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/11/14 7 60,620 3 4,820 1 2 4.00 12.57 09/01/14 28 72,970 2 5,810 1 3 4.00 12.57 09/01/14 28 70,140 3 5,580 1 4 4.00 12.57 09/01/14 28 72,800 2 5,790 Average (28 days) 5,730 1 5 4.00 12.57 09/29/14 56 74,350 1 5,920 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0146 08/04/14 09/30/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0451 1176 Plant: Ticket No.: P136 25909066 Field Test Data Test Air Content (%): Result Specification 4 1/4 3-5 1.4 0-3 88 76 151.3 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/04/14 0540 Daniel Duran Clear 150/330 10 0 0 N.4/4.7Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ K.5-O.9/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/11/14 7 60,430 2 4,810 2 2 4.00 12.57 09/01/14 28 71,610 2 5,700 2 3 4.00 12.57 09/01/14 28 68,860 2 5,480 2 4 4.00 12.57 09/01/14 28 70,750 3 5,630 Average (28 days) 5,600 2 5 4.00 12.57 09/29/14 56 73,280 4 5,830 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0146 08/04/14 09/30/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0616 1452 Plant: Ticket No.: P136 25909132 Field Test Data Test Air Content (%): Result Specification 4 1/4 3-5 1.6 0-3 86 76 150.1 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/04/14 0707 Daniel Duran Clear 250/330 10 0 0 M/3.2Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ K.5-O.9/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/11/14 7 54,720 4 4,350 3 2 4.00 12.57 09/01/14 28 70,160 3 5,580 3 3 4.00 12.57 09/01/14 28 69,400 2 5,520 3 4 4.00 12.57 09/01/14 28 70,160 2 5,580 Average (28 days) 5,560 3 5 4.00 12.57 09/29/14 56 72,060 5 5,730 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0146 08/04/14 09/30/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0700 1176 Plant: Ticket No.: P136 25909199 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 1.2 0-3 88 76 150.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/04/14 0750 Daniel Duran Clear 300/330 10 10 0 L.2/3.9Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg D, Slab-on-Grade @ K.5-O.9/3-4.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 08/11/14 7 53,210 5 4,230 4 2 4.00 12.57 09/01/14 28 68,410 3 5,440 4 3 4.00 12.57 09/01/14 28 68,700 2 5,470 4 4 4.00 12.57 09/01/14 28 68,660 4 5,460 Average (28 days) 5,460 4 5 4.00 12.57 09/29/14 56 71,680 4 5,700 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 4CR0001, 11-16-12, Rev.6 FOUNDATION OBSERVATIONS REPORT Report Number:94141126.0147 Service Date:08/04/14 8901 Carpenter Frwy., Suite 100 Report Date:08/12/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Drilled belled (underreamed) pier observation. Terracon Rep.: Jonathan Baze Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 tp On this date, Terracon's representative arrived at the above referenced job site as scheduled for drilled belled pier observation. See the attached sheet(s) for recorded data. REPORT OF DRILLED BELLED PIERS Project: Park West Crossing - Building A Report No.: 94141126.0147 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd, Coppell, TX Date of Service: 08/04/14 Project No.: 94141126 Technician: J. Baze Driller: Auger Page: 1 of 2 Pier Identification F/1 E.5/1 E.2/1 D.8/1 C.2/1 B.8/1 B.4/1 B/1 A/3.8 Pier Diameter (in.)24 24 24 24 24 24 24 24 24 Bell Diameter (in.)72 72 72 72 72 72 72 72 72 Top of Pier Elevation (ft)N/A N/A N/A N/A N/A N/A N/A N/A N/A Req. Depth from Exist. Grade (ft)15.8 15.8 15.8 15.8 15.8 15.8 15.8 15.8 15.8 Initial Depth of Pier from Existing Grade (ft)15.5 16.2 15.5 16.0 15.3 16.8 15.2 16.6 17.5 Final Depth of Pier from Existing Grade (ft)17.8 20.0 15.8 16.0 16.4 17.0 15.8 16.6 20.8 Depth from Top of Concrete (ft)17.9 20.0 15.8 16.0 16.6 17.2 16.0 16.8 20.8 Condition of Bottom (wet or dry)Dry Dry Dry Dry Dry Dry Dry Dry Dry Plumb Within Tolerance (yes or no)Yes Yes Yes Yes Yes Yes Yes Yes Yes Casing Diameter (in) N/A N/A N/A N/A N/A N/A N/A N/A N/A Cased Depth (ft)N/A N/A N/A N/A N/A N/A N/A N/A N/A Number of Vertical Bars (ea.)6 6 6 6 6 6 6 6 6 Reinforcing Bar Size (#)6 6 6 6 6 6 6 6 6 Length of Vertical Bars (ft.)17.4 19.5 15.3 15.5 16.1 16.7 15.5 16.3 20.3 Time Drilling was Completed 08:25 09:15 09:15 10:00 10:15 11:00 11:40 12:15 15:00 Time Concrete was Placed 09:30 09:40 10:15 10:50 11:40 11:50 14:30 14:45 18:30 R940002, 08-05-14, Rev.3 8901 Carpenter Frwy.,Suite #100 Dallas,TX 75247 (214)630-1010 Reg No.:F-3272 REPORT OF DRILLED BELLED PIERS Project: Park West Crossing - Building A Report No.: 94141126.0147 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd, Coppell, TX Date of Service: 08/04/14 Project No.: 94141126 Technician: J. Baze Driller: Auger Page: 2 of 2 Pier Identification A/3.4 A/2.9 A/2.5 A/2.2 Pier Diameter (in.)24 24 24 24 Bell Diameter (in.)72 72 72 72 Top of Pier Elevation (ft)N/A N/A N/A N/A Req. Depth from Exist. Grade (ft)15.8 15.8 15.8 15.8 Initial Depth of Pier from Existing Grade (ft)15.5 16.0 16.2 15.6 Final Depth of Pier from Existing Grade (ft)15.9 16.5 16.6 17.6 Depth from Top of Concrete (ft)15.9 16.5 16.6 17.6 Condition of Bottom (wet or dry)Dry Dry Dry Dry Plumb Within Tolerance (yes or no)Yes Yes Yes Yes Casing Diameter (in) N/A N/A N/A N/A Cased Depth (ft)N/A N/A N/A N/A Number of Vertical Bars (ea.)6 6 6 6 Reinforcing Bar Size (#)6 6 6 6 Length of Vertical Bars (ft.)15.4 16.0 16.1 17.1 Time Drilling was Completed 15:40 16:15 16:45 17:20 Time Concrete was Placed 17:40 17:50 18:00 18:40 R940002, 08-05-14, Rev.3 8901 Carpenter Frwy.,Suite #100 Dallas,TX 75247 (214)630-1010 Reg No.:F-3272 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0148 08/04/14 08/13/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1654 1459 Plant: Ticket No.: 136 25909911 Field Test Data Test Air Content (%): Result Specification 7 5-7 1.2 0-3 92 93 150.8 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/04/14 1810 Jonathan Baze Clear, windy 50/50 10 0 0 Piers @ A/1.6 & A/2.2Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report Nos. 94141126.0147 & 94141126.0154. dated 08/04/14, for pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/11/14 7 29,400 5 2,340 1 2 4.00 12.57 09/01/14 28 1 3 4.00 12.57 09/01/14 28 1 4 4.00 12.57 09/01/14 28 1 5 4.00 12.57 09/29/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0148 08/04/14 09/03/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1654 1459 Plant: Ticket No.: 136 25909911 Field Test Data Test Air Content (%): Result Specification 7 5-7 1.2 0-3 92 93 150.8 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/04/14 1810 Jonathan Baze Clear, windy 50/50 10 0 0 Piers @ A/1.6 & A/2.2Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report Nos. 94141126.0147 & 94141126.0154. dated 08/04/14, for pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/11/14 7 29,400 5 2,340 1 2 4.00 12.57 09/01/14 28 50,480 3 4,020 1 3 4.00 12.57 09/01/14 28 48,510 2 3,860 1 4 4.00 12.57 09/01/14 28 45,340 1 3,610 Average (28 days) 3,830 1 5 4.00 12.57 09/29/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0148 08/04/14 09/29/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 1654 1459 Plant: Ticket No.: 136 25909911 Field Test Data Test Air Content (%): Result Specification 7 5-7 1.2 0-3 92 93 150.8 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/04/14 1810 Jonathan Baze Clear, windy 50/50 10 0 0 Piers @ A/1.6 & A/2.2Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report Nos. 94141126.0147 & 94141126.0154. dated 08/04/14, for pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/11/14 7 29,400 5 2,340 1 2 4.00 12.57 09/01/14 28 50,480 3 4,020 1 3 4.00 12.57 09/01/14 28 48,510 2 3,860 1 4 4.00 12.57 09/01/14 28 45,340 1 3,610 Average (28 days) 3,830 1 5 4.00 12.57 09/29/14 56 49,620 1 3,950 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jonathan Baze The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 GRADATION REPORT Report Number:94141126.0150 Service Date:08/04/14 8901 Carpenter Frwy., Suite 100 Report Date:08/12/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Perform gradation tests on lime stabilized soil. Terracon Rep.: Armando Rendon Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940006, 05-23-14, Rev.2 Page 1 of 1 dgr SERVICES:SPECIFICATION REQUIREMENTS: Minimum Passing 1 3/4” Sieve (%):100 Performed gradation tests on lime treated soil. Minimum Passing #4 Sieve (%): 60 TEST METHOD:NCTCOG Sample Condition: Field Moist TEST LOCATION:E of Bldg. C TEST NO.LOCATION 1 3/4” SIEVE % PASSING #4 SIEVE % PASSING 1 50’ N & 10’ W of SE corner 100 63 2 150’ N & 20’ W of SE corner 100 65 3 250’ N & 30’ W of SE corner 100 65 4 350’ N & 10’ W of SE corner 100 63 5 450’ N & 20’ W of SE corner 100 65 REINFORCING STEEL OBSERVATIONS REPORT Report Number:94141126.0151 Service Date:08/05/14 8901 Carpenter Frwy., Suite 100 Report Date:08/12/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Reinforcing steel (rebar) placement observation. Terracon Rep.: Daniel Duran Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940003, 07-01-12, Rev.0 Page 1 of 1 tp PROJECT DATA Drawings Utilized:Structural Sheets/Details: S2.1/Building C, Foundation Paving Plan, dated 10/24/13 Locations/Items Observed:Building C, Slab-on-Grade @ A.2 – L.8/2.0 – 3.8 Test Method:Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT Placing Drawings Approved X Bar Length and Shape X Column Tie Spacing & Type Bar Size X Proper Bar Placement X Stirrup Spacing & Type Bar Grade X Properly Tied X Welded Splices Rebar Clean X Dowel Bars in Place X Mechanical Splices Trash & Debris Removed X Proper Bar Supports X Lapped Splices X Number of Bars X Proper Cover/Clearance X Discrepancies/Comments: No discrepancies were noted at the time of this observation. Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 08/14/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0308 1425 Plant: Ticket No.: 236 25909969 Field Test Data Test Air Content (%): Result Specification 4 3-5 2.2 0-3 90 76 150.7 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 0400 Daniel Duran Clear 80/870 10 10 0 L.2/2.2Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/12/14 7 69,120 4 5,500 1 2 4.00 12.57 09/02/14 28 1 3 4.00 12.57 09/02/14 28 1 4 4.00 12.57 09/02/14 28 1 5 4.00 12.57 09/30/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 08/14/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0355 1176 Plant: Ticket No.: 236 25910000 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 2.0 0-3 89 75 150.7 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 0500 Daniel Duran Clear 150/870 10 0 0 K.3/3.6Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/12/14 7 66,350 3 5,280 2 2 4.00 12.57 09/02/14 28 2 3 4.00 12.57 09/02/14 28 2 4 4.00 12.57 09/02/14 28 2 5 4.00 12.57 09/30/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 08/14/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0436 1425 Plant: Ticket No.: 236 25910024 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.3 0-3 87 76 149.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 0530 Daniel Duran Clear 200/870 10 10 0 I.4/3Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/12/14 7 59,170 2 4,710 3 2 4.00 12.57 09/02/14 28 3 3 4.00 12.57 09/02/14 28 3 4 4.00 12.57 09/02/14 28 3 5 4.00 12.57 09/30/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 08/14/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0558 1452 Plant: Ticket No.: 236 25910133 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 1.5 0-3 89 76 149.3 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 0640 Daniel Duran Clear 350/870 10 0 0 H.5/3.5Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 08/12/14 7 58,750 2 4,680 4 2 4.00 12.57 09/02/14 28 4 3 4.00 12.57 09/02/14 28 4 4 4.00 12.57 09/02/14 28 4 5 4.00 12.57 09/30/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 08/14/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0644 1190 Plant: Ticket No.: 236 25910183 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.4 0-3 87 76 150.1 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 0722 Daniel Duran Clear 430/870 10 0 0 G/3.6Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 08/12/14 7 57,670 3 4,590 5 2 4.00 12.57 09/02/14 28 5 3 4.00 12.57 09/02/14 28 5 4 4.00 12.57 09/02/14 28 5 5 4.00 12.57 09/30/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 08/14/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0903 1185 Plant: Ticket No.: 236 25910409 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.6 0-3 88 78 150.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 0920 Daniel Duran Clear 570/870 10 0 0 E.4.2.8Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 6 1 4.00 12.57 08/12/14 7 58,050 4 4,620 6 2 4.00 12.57 09/02/14 28 6 3 4.00 12.57 09/02/14 28 6 4 4.00 12.57 09/02/14 28 6 5 4.00 12.57 09/30/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 08/14/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0945 1425 Plant: Ticket No.: 236 25910465 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.2 0-3 90 80 151.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 Daniel Duran Clear 620/870 10 0 0 D.1/3.1Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 7 1 4.00 12.57 08/12/14 7 53,400 4 4,250 7 2 4.00 12.57 09/02/14 28 7 3 4.00 12.57 09/02/14 28 7 4 4.00 12.57 09/02/14 28 7 5 4.00 12.57 09/30/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 7 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 08/14/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 1201 1236 Plant: Ticket No.: 236 25910676 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 1.4 0-3 90 80 152.1 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 1240 Daniel Duran 790/870 10 0 0 B.7/2.3Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 8 1 4.00 12.57 08/12/14 7 61,830 2 4,920 8 2 4.00 12.57 09/02/14 28 8 3 4.00 12.57 09/02/14 28 8 4 4.00 12.57 09/02/14 28 8 5 4.00 12.57 09/30/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 8 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 08/14/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 1252 1184 Plant: Ticket No.: 236 25910739 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.0 0-3 95 88 152.9 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 1330 Daniel Duran Clear 820/870 10 0 0 A.6/2.8Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 9 1 4.00 12.57 08/12/14 7 47,210 2 3,760 9 2 4.00 12.57 09/02/14 28 9 3 4.00 12.57 09/02/14 28 9 4 4.00 12.57 09/02/14 28 9 5 4.00 12.57 09/30/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 9 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 09/03/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0308 1425 Plant: Ticket No.: 236 25909969 Field Test Data Test Air Content (%): Result Specification 4 3-5 2.2 0-3 90 76 150.7 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 0400 Daniel Duran Clear 80/870 10 10 0 L.2/2.2Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/12/14 7 69,120 4 5,500 1 2 4.00 12.57 09/02/14 28 76,230 5 6,070 1 3 4.00 12.57 09/02/14 28 72,240 5 5,750 1 4 4.00 12.57 09/02/14 28 78,060 2 6,210 Average (28 days) 6,010 1 5 4.00 12.57 09/30/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 09/03/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0355 1176 Plant: Ticket No.: 236 25910000 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 2.0 0-3 89 75 150.7 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 0500 Daniel Duran Clear 150/870 10 0 0 K.3/3.6Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/12/14 7 66,350 3 5,280 2 2 4.00 12.57 09/02/14 28 82,060 3 6,530 2 3 4.00 12.57 09/02/14 28 76,900 2 6,120 2 4 4.00 12.57 09/02/14 28 76,420 5 6,080 Average (28 days) 6,240 2 5 4.00 12.57 09/30/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 09/03/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0436 1425 Plant: Ticket No.: 236 25910024 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.3 0-3 87 76 149.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 0530 Daniel Duran Clear 200/870 10 10 0 I.4/3Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/12/14 7 59,170 2 4,710 3 2 4.00 12.57 09/02/14 28 69,360 2 5,520 3 3 4.00 12.57 09/02/14 28 69,500 4 5,530 3 4 4.00 12.57 09/02/14 28 68,070 5 5,420 Average (28 days) 5,490 3 5 4.00 12.57 09/30/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 09/03/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0558 1452 Plant: Ticket No.: 236 25910133 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 1.5 0-3 89 76 149.3 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 0640 Daniel Duran Clear 350/870 10 0 0 H.5/3.5Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 08/12/14 7 58,750 2 4,680 4 2 4.00 12.57 09/02/14 28 68,460 2 5,450 4 3 4.00 12.57 09/02/14 28 69,770 4 5,550 4 4 4.00 12.57 09/02/14 28 67,810 4 5,400 Average (28 days) 5,470 4 5 4.00 12.57 09/30/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 09/03/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0644 1190 Plant: Ticket No.: 236 25910183 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.4 0-3 87 76 150.1 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 0722 Daniel Duran Clear 430/870 10 0 0 G/3.6Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 08/12/14 7 57,670 3 4,590 5 2 4.00 12.57 09/02/14 28 70,080 3 5,580 5 3 4.00 12.57 09/02/14 28 67,330 2 5,360 5 4 4.00 12.57 09/02/14 28 68,500 5 5,450 Average (28 days) 5,460 5 5 4.00 12.57 09/30/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 09/03/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0903 1185 Plant: Ticket No.: 236 25910409 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.6 0-3 88 78 150.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 0920 Daniel Duran Clear 570/870 10 0 0 E.4.2.8Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 6 1 4.00 12.57 08/12/14 7 58,050 4 4,620 6 2 4.00 12.57 09/02/14 28 69,850 4 5,560 6 3 4.00 12.57 09/02/14 28 72,000 5 5,730 6 4 4.00 12.57 09/02/14 28 70,460 4 5,610 Average (28 days) 5,630 6 5 4.00 12.57 09/30/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 09/03/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0945 1425 Plant: Ticket No.: 236 25910465 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.2 0-3 90 80 151.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 Daniel Duran Clear 620/870 10 0 0 D.1/3.1Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 7 1 4.00 12.57 08/12/14 7 53,400 4 4,250 7 2 4.00 12.57 09/02/14 28 65,290 3 5,200 7 3 4.00 12.57 09/02/14 28 68,840 5 5,480 7 4 4.00 12.57 09/02/14 28 66,600 3 5,300 Average (28 days) 5,330 7 5 4.00 12.57 09/30/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 7 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 09/03/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 1201 1236 Plant: Ticket No.: 236 25910676 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 1.4 0-3 90 80 152.1 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 1240 Daniel Duran 790/870 10 0 0 B.7/2.3Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 8 1 4.00 12.57 08/12/14 7 61,830 2 4,920 8 2 4.00 12.57 09/02/14 28 69,880 5 5,560 8 3 4.00 12.57 09/02/14 28 72,030 5 5,730 8 4 4.00 12.57 09/02/14 28 72,720 2 5,790 Average (28 days) 5,690 8 5 4.00 12.57 09/30/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 8 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 09/03/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 1252 1184 Plant: Ticket No.: 236 25910739 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.0 0-3 95 88 152.9 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 1330 Daniel Duran Clear 820/870 10 0 0 A.6/2.8Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 9 1 4.00 12.57 08/12/14 7 47,210 2 3,760 9 2 4.00 12.57 09/02/14 28 61,380 3 4,880 9 3 4.00 12.57 09/02/14 28 60,810 5 4,840 9 4 4.00 12.57 09/02/14 28 61,580 5 4,900 Average (28 days) 4,870 9 5 4.00 12.57 09/30/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 9 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 10/01/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0308 1425 Plant: Ticket No.: 236 25909969 Field Test Data Test Air Content (%): Result Specification 4 3-5 2.2 0-3 90 76 150.7 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 0400 Daniel Duran Clear 80/870 10 10 0 L.2/2.2Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/12/14 7 69,120 4 5,500 1 2 4.00 12.57 09/02/14 28 76,230 5 6,070 1 3 4.00 12.57 09/02/14 28 72,240 5 5,750 1 4 4.00 12.57 09/02/14 28 78,060 2 6,210 Average (28 days) 6,010 1 5 4.00 12.57 09/30/14 56 88,990 1 7,080 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 10/01/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0355 1176 Plant: Ticket No.: 236 25910000 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 2.0 0-3 89 75 150.7 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 0500 Daniel Duran Clear 150/870 10 0 0 K.3/3.6Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/12/14 7 66,350 3 5,280 2 2 4.00 12.57 09/02/14 28 82,060 3 6,530 2 3 4.00 12.57 09/02/14 28 76,900 2 6,120 2 4 4.00 12.57 09/02/14 28 76,420 5 6,080 Average (28 days) 6,240 2 5 4.00 12.57 09/30/14 56 87,190 2 6,940 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 10/01/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0436 1425 Plant: Ticket No.: 236 25910024 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.3 0-3 87 76 149.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 0530 Daniel Duran Clear 200/870 10 10 0 I.4/3Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/12/14 7 59,170 2 4,710 3 2 4.00 12.57 09/02/14 28 69,360 2 5,520 3 3 4.00 12.57 09/02/14 28 69,500 4 5,530 3 4 4.00 12.57 09/02/14 28 68,070 5 5,420 Average (28 days) 5,490 3 5 4.00 12.57 09/30/14 56 76,430 2 6,080 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 10/01/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0558 1452 Plant: Ticket No.: 236 25910133 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 1.5 0-3 89 76 149.3 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 0640 Daniel Duran Clear 350/870 10 0 0 H.5/3.5Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 08/12/14 7 58,750 2 4,680 4 2 4.00 12.57 09/02/14 28 68,460 2 5,450 4 3 4.00 12.57 09/02/14 28 69,770 4 5,550 4 4 4.00 12.57 09/02/14 28 67,810 4 5,400 Average (28 days) 5,470 4 5 4.00 12.57 09/30/14 56 73,870 3 5,880 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 10/01/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0644 1190 Plant: Ticket No.: 236 25910183 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.4 0-3 87 76 150.1 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 0722 Daniel Duran Clear 430/870 10 0 0 G/3.6Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 08/12/14 7 57,670 3 4,590 5 2 4.00 12.57 09/02/14 28 70,080 3 5,580 5 3 4.00 12.57 09/02/14 28 67,330 2 5,360 5 4 4.00 12.57 09/02/14 28 68,500 5 5,450 Average (28 days) 5,460 5 5 4.00 12.57 09/30/14 56 72,330 2 5,760 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 10/01/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0903 1185 Plant: Ticket No.: 236 25910409 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.6 0-3 88 78 150.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 0920 Daniel Duran Clear 570/870 10 0 0 E.4.2.8Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 6 1 4.00 12.57 08/12/14 7 58,050 4 4,620 6 2 4.00 12.57 09/02/14 28 69,850 4 5,560 6 3 4.00 12.57 09/02/14 28 72,000 5 5,730 6 4 4.00 12.57 09/02/14 28 70,460 4 5,610 Average (28 days) 5,630 6 5 4.00 12.57 09/30/14 56 73,850 3 5,880 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 10/01/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0945 1425 Plant: Ticket No.: 236 25910465 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.2 0-3 90 80 151.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 Daniel Duran Clear 620/870 10 0 0 D.1/3.1Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 7 1 4.00 12.57 08/12/14 7 53,400 4 4,250 7 2 4.00 12.57 09/02/14 28 65,290 3 5,200 7 3 4.00 12.57 09/02/14 28 68,840 5 5,480 7 4 4.00 12.57 09/02/14 28 66,600 3 5,300 Average (28 days) 5,330 7 5 4.00 12.57 09/30/14 56 75,800 2 6,030 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 7 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 10/01/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 1201 1236 Plant: Ticket No.: 236 25910676 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 1.4 0-3 90 80 152.1 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 1240 Daniel Duran 790/870 10 0 0 B.7/2.3Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 8 1 4.00 12.57 08/12/14 7 61,830 2 4,920 8 2 4.00 12.57 09/02/14 28 69,880 5 5,560 8 3 4.00 12.57 09/02/14 28 72,030 5 5,730 8 4 4.00 12.57 09/02/14 28 72,720 2 5,790 Average (28 days) 5,690 8 5 4.00 12.57 09/30/14 56 76,670 3 6,100 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 8 of 9CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0152 08/05/14 10/01/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 1252 1184 Plant: Ticket No.: 236 25910739 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.0 0-3 95 88 152.9 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 1330 Daniel Duran Clear 820/870 10 0 0 A.6/2.8Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg C, Slab-on-Grade @ A.2-6.8/2.0-3.8 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 9 1 4.00 12.57 08/12/14 7 47,210 2 3,760 9 2 4.00 12.57 09/02/14 28 61,380 3 4,880 9 3 4.00 12.57 09/02/14 28 60,810 5 4,840 9 4 4.00 12.57 09/02/14 28 61,580 5 4,900 Average (28 days) 4,870 9 5 4.00 12.57 09/30/14 56 64,360 3 5,120 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 9 of 9CR0001, 11-16-12, Rev.6 FOUNDATION OBSERVATIONS REPORT Report Number:94141126.0154 Service Date:08/04/14 8901 Carpenter Frwy., Suite 100 Report Date:08/12/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Drilled belled (underreamed) pier observation. Terracon Rep.: Jason Carrizales Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 tp On this date, Terracon's representative arrived at the above referenced job site as scheduled for drilled belled pier observation. See the attached sheet(s) for recorded data. REPORT OF DRILLED BELLED PIERS Project: Park West Crossing - Building A Report No.: 94141126.0154 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd, Coppell, TX Date of Service: 08/04/14 Project No.: 94141126 Technician: J. Carrizales Driller: Auger Drilling/Agreda Drilling Page: 1 of 1 Pier Identification F.5/1 G/1 G/1.6 A/1.6 Pier Diameter (in.)30 30 30 30 Bell Diameter (in.)84 84 84 84 Top of Pier Elevation (ft)N/A N/A N/A N/A Req. Depth from Exist. Grade (ft)14.5 15.3 15.3 15.3 Initial Depth of Pier from Existing Grade (ft)15.0 15.5 15.5 16.2 Final Depth of Pier from Existing Grade (ft)16.0 16.5 16.4 17.8 Depth from Top of Concrete (ft)15.1 15.6 16.6 16.9 Condition of Bottom (wet or dry)Dry Dry Dry Dry Plumb Within Tolerance (yes or no)Yes Yes Yes Yes Casing Diameter (in) N/A N/A N/A N/A Cased Depth (ft)N/A N/A N/A N/A Number of Vertical Bars (ea.)6 6 6 6 Reinforcing Bar Size (#)7 7 7 7 Length of Vertical Bars (ft.)18.1 17.6 17.5 18.9 Time Drilling was Completed 12:00 13:20 13:50 17:05 Time Concrete was Placed 13:45 14:00 14:15 14:45 R940002, 08-05-14, Rev.3 8901 Carpenter Frwy.,Suite #100 Dallas,TX 75247 (214)630-1010 Reg No.:F-3272 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0155 08/04/14 08/13/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0721 1430 Plant: Ticket No.:25909232 Field Test Data Test Air Content (%): Result Specification 3 1/2 3-5 1.5 0-3 92 78 149.9 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/04/14 0931 Jason Carrizales Clear, hot 10/330 10 0 0 Pier @ F/1Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report Nos. 94141126.0154 & 94141126.0147, dated 08/04/14, for pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/11/14 7 52,520 2 4,180 1 2 4.00 12.57 09/01/14 28 1 3 4.00 12.57 09/01/14 28 1 4 4.00 12.57 09/01/14 28 1 5 4.00 12.57 09/29/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jason Carrizales The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0155 08/04/14 09/03/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0721 1430 Plant: Ticket No.:25909232 Field Test Data Test Air Content (%): Result Specification 3 1/2 3-5 1.5 0-3 92 78 149.9 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/04/14 0931 Jason Carrizales Clear, hot 10/330 10 0 0 Pier @ F/1Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report Nos. 94141126.0154 & 94141126.0147, dated 08/04/14, for pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/11/14 7 52,520 2 4,180 1 2 4.00 12.57 09/01/14 28 63,860 1 5,080 1 3 4.00 12.57 09/01/14 28 63,980 2 5,090 1 4 4.00 12.57 09/01/14 28 62,880 3 5,000 Average (28 days) 5,060 1 5 4.00 12.57 09/29/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jason Carrizales The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0155 08/04/14 09/29/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0721 1430 Plant: Ticket No.:25909232 Field Test Data Test Air Content (%): Result Specification 3 1/2 3-5 1.5 0-3 92 78 149.9 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/04/14 0931 Jason Carrizales Clear, hot 10/330 10 0 0 Pier @ F/1Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report Nos. 94141126.0154 & 94141126.0147, dated 08/04/14, for pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/11/14 7 52,520 2 4,180 1 2 4.00 12.57 09/01/14 28 63,860 1 5,080 1 3 4.00 12.57 09/01/14 28 63,980 2 5,090 1 4 4.00 12.57 09/01/14 28 62,880 3 5,000 Average (28 days) 5,060 1 5 4.00 12.57 09/29/14 56 64,460 4 5,130 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jason Carrizales The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 FOUNDATION OBSERVATIONS REPORT Report Number:94141126.0156 Service Date:08/05/14 8901 Carpenter Frwy., Suite 100 Report Date:08/12/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Drilled belled (underreamed) pier observation. Terracon Rep.: Jonathan Baze Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 tp On this date, Terracon's representative arrived at the above referenced job site as scheduled for drilled belled pier observation. See the attached sheet(s) for recorded data. REPORT OF DRILLED BELLED PIERS Project: Park West Crossing - Building D Report No.: 94141126.0156 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd, Coppell, TX Date of Service: 08/05/14 Project No.: 94141126 Technician: J. Baze Driller: Auger Page: 1 of 2 Pier Identification A.9/5 B.2/5 B.6/B C.1/5 C.5/5 C.9/5 D.3/5 D.6/5 E.1/5 F.9/5 G.4/5 Pier Diameter (in.)24 24 24 24 24 24 24 24 24 24 24 Bell Diameter (in.)72 72 72 72 72 72 72 72 72 72 72 Top of Pier Elevation (ft)N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Req. Depth from Exist. Grade (ft)14.8 14.8 14.8 14.8 14.8 16.8 16.8 14.8 14.8 15.5 15.5 Initial Depth of Pier from Existing Grade (ft)15.0 14.8 14.9 14.9 14.8 16.8 17.0 14.6 15.0 15.6 15.8 Final Depth of Pier from Existing Grade (ft)15.8 15.9 15.3 15.7 15.7 18.6 18.8 15.2 16.0 16.2 16.1 Depth from Top of Concrete (ft)15.9 16.0 15.4 15.8 15.8 17.6 17.8 15.3 15.9 16.1 16.0 Condition of Bottom (wet or dry)Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry Plumb Within Tolerance (yes or no)Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Casing Diameter (in) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Cased Depth (ft)N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Number of Vertical Bars (ea.)6 6 6 6 6 6 6 6 6 6 6 Reinforcing Bar Size (#)6 6 6 6 6 6 6 6 6 6 6 Length of Vertical Bars (ft.)15.4 15.5 14.9 15.3 15.3 17.1 17.3 14.8 15.4 15.6 15.5 Time Drilling was Completed 08:45 9:30 10:35 10:30 11:00 12:00 14:00 11:20 14:35 12:15 13:40 Time Concrete was Placed 13:15 13:30 13:40 13:55 14:00 14:40 14:50 14:30 15:00 15:15 15:20 R940002, 08-05-14, Rev.3 8901 Carpenter Frwy.,Suite #100 Dallas,TX 75247 (214)630-1010 Reg No.:F-3272 REPORT OF DRILLED BELLED PIERS Project: Park West Crossing - Building D Report No.: 94141126.0156 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd, Coppell, TX Date of Service: 08/05/14 Project No.: 94141126 Technician: J. Baze Driller: Auger Page: 2 of 2 Pier Identification G.7/5 H.1/5 H.5/5 H.9/5 I.3/5 K.9/5 M.9/5 M.1/5 M.5/5 Pier Diameter (in.)24 24 24 24 24 24 24 24 24 Bell Diameter (in.)72 72 72 72 72 72 72 72 72 Top of Pier Elevation (ft)N/A N/A N/A N/A N/A N/A N/A N/A N/A Req. Depth from Exist. Grade (ft)15.5 15.5 15.5 15.5 15.5 15.5 15.5 15.5 15.5 Initial Depth of Pier from Existing Grade (ft)15.6 15.9 15.8 15.8 15.6 15.7 15.7 15.8 15.6 Final Depth of Pier from Existing Grade (ft)15.6 15.9 15.8 16.9 15.8 16.2 16.7 16.5 16.0 Depth from Top of Concrete (ft)15.5 15.8 15.7 16.8 15.7 16.2 16.7 16.5 16.0 Condition of Bottom (wet or dry)Dry Dry Dry Dry Dry Dry Dry Dry Dry Plumb Within Tolerance (yes or no)Yes Yes Yes Yes Yes Yes Yes Yes Yes Casing Diameter (in) N/A N/A N/A N/A N/A N/A N/A N/A N/A Cased Depth (ft)N/A N/A N/A N/A N/A N/A N/A N/A N/A Number of Vertical Bars (ea.)6 6 6 6 6 6 6 6 6 Reinforcing Bar Size (#)6 6 6 6 6 6 6 6 6 Length of Vertical Bars (ft.)15.0 15.3 15.2 16.3 15.2 15.7 16.2 16.0 15.5 Time Drilling was Completed 14:05 14:30 15:00 15:20 15:55 15:15 15:50 16:30 16:30 Time Concrete was Placed 15:30 15:45 16:00 16:20 16:40 17:45 17:55 18:05 18:15 R940002, 08-05-14, Rev.3 8901 Carpenter Frwy.,Suite #100 Dallas,TX 75247 (214)630-1010 Reg No.:F-3272 FOUNDATION OBSERVATIONS REPORT Report Number:94141126.0159 Service Date:08/05/14 8901 Carpenter Frwy., Suite 100 Report Date:08/12/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Drilled belled (underreamed) pier observation. Terracon Rep.: Jason Carrizales Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 tp On this date, Terracon's representative arrived at the above referenced job site as scheduled for drilled belled pier observation. See the attached sheet(s) for recorded data. REPORT OF DRILLED BELLED PIERS Project: Park West Crossing - Building A Report No.: 94141126.0159 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd, Coppell, TX Date of Service: 08/05/14 Project No.: 94141126 Technician: J. Carrizales Driller: Auger Drilling Page: 1 of 2 Pier Identification A/1 A.5/1 Pier Diameter (in.)30 30 Bell Diameter (in.)84 84 Top of Pier Elevation (ft)N/A N/A Req. Depth from Exist. Grade (ft)15.5 15.5 Initial Depth of Pier from Existing Grade (ft)15.8 16.1 Final Depth of Pier from Existing Grade (ft)15.9 16.1 Depth from Top of Concrete (ft)15.0 15.5 Condition of Bottom (wet or dry)Dry Dry Plumb Within Tolerance (yes or no)Yes Yes Casing Diameter (in) N/A N/A Cased Depth (ft)N/A N/A Number of Vertical Bars (ea.)6 6 Reinforcing Bar Size (#)7 7 Length of Vertical Bars (ft.)18.1 18.3 Time Drilling was Completed 08:10 08:40 Time Concrete was Placed 10:10 10:20 R940002, 08-05-14, Rev.3 8901 Carpenter Frwy.,Suite #100 Dallas,TX 75247 (214)630-1010 Reg No.:F-3272 REPORT OF DRILLED BELLED PIERS Project: Park West Crossing - Building D Report No.: 94141126.0159 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd, Coppell, TX Date of Service: 08/05/14 Project No.: 94141126 Technician: J. Carrizales Driller: Auger Drilling Page: 2 of 2 Pier Identification A/5 A/4.4 A.5/5 Pier Diameter (in.)30 30 30 Bell Diameter (in.)84 84 84 Top of Pier Elevation (ft)N/A N/A N/A Req. Depth from Exist. Grade (ft)16.8 16.8 16.8 Initial Depth of Pier from Existing Grade (ft)16.8 17.2 16.8 Final Depth of Pier from Existing Grade (ft)17.8 17.6 17.2 Depth from Top of Concrete (ft)15.6 15.4 15.0 Condition of Bottom (wet or dry)Dry Dry Dry Plumb Within Tolerance (yes or no)Yes Yes Yes Casing Diameter (in) N/A N/A N/A Cased Depth (ft)N/A N/A N/A Number of Vertical Bars (ea.)6 6 6 Reinforcing Bar Size (#)7 7 7 Length of Vertical Bars (ft.)16.3 17.1 17.0 Time Drilling was Completed 09:15 09:40 10:45 Time Concrete was Placed 13:40 13:45 15:00 R940002, 08-05-14, Rev.3 8901 Carpenter Frwy.,Suite #100 Dallas,TX 75247 (214)630-1010 Reg No.:F-3272 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0160 08/05/14 08/14/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 0910 1186 Plant: Ticket No.: 236 25910373 Field Test Data Test Air Content (%): Result Specification 6 1/4 5-7 0.9 0-3 88 78 149.2 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 1015 Jason Carrizales Clear, hot 10/75 10 0 0 Pier A.5/1, Bldg ASample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report No. 94141126.0159, dated 08/05/14, for pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/12/14 7 46,330 2 3,690 1 2 4.00 12.57 09/02/14 28 1 3 4.00 12.57 09/02/14 28 1 4 4.00 12.57 09/02/14 28 1 5 4.00 12.57 09/30/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jason Carrizales The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0160 08/05/14 09/03/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 0910 1186 Plant: Ticket No.: 236 25910373 Field Test Data Test Air Content (%): Result Specification 6 1/4 5-7 0.9 0-3 88 78 149.2 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 1015 Jason Carrizales Clear, hot 10/75 10 0 0 Pier A.5/1, Bldg ASample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report No. 94141126.0159, dated 08/05/14, for pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/12/14 7 46,330 2 3,690 1 2 4.00 12.57 09/02/14 28 56,370 4 4,490 1 3 4.00 12.57 09/02/14 28 58,680 4 4,670 1 4 4.00 12.57 09/02/14 28 61,880 2 4,920 Average (28 days) 4,690 1 5 4.00 12.57 09/30/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jason Carrizales The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0160 08/05/14 10/01/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 80J11521 Redi-Mix Material Information 0910 1186 Plant: Ticket No.: 236 25910373 Field Test Data Test Air Content (%): Result Specification 6 1/4 5-7 0.9 0-3 88 78 149.2 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/05/14 1015 Jason Carrizales Clear, hot 10/75 10 0 0 Pier A.5/1, Bldg ASample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Drilled Piers, see Foundation Observations Report No. 94141126.0159, dated 08/05/14, for pier locations Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/12/14 7 46,330 2 3,690 1 2 4.00 12.57 09/02/14 28 56,370 4 4,490 1 3 4.00 12.57 09/02/14 28 58,680 4 4,670 1 4 4.00 12.57 09/02/14 28 61,880 2 4,920 Average (28 days) 4,690 1 5 4.00 12.57 09/30/14 56 65,760 2 5,230 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jason Carrizales The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0162 08/05/14 08/12/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 95-1/+3186.830.294141126.0036 Lime treated dark and light brown clay ASTM D698 92-98>/= +4296.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 95-2/+2386.830.294141126.0036 Lime treated dark and light brown clay ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Fire Lane, East of Building C 2101 50' N & 10' W of SE corner Final 1 6 111.6 26.8 31.6 84.8 98 2102 150' N & 20' W of SE corner Final 1 6 111.2 26.9 31.9 84.3 97 2103 250' N & 30' W of SE corner Final 1 6 110.7 27.1 32.4 83.6 96 2104 350' N & 10' W of SE corner Final 1 6 110.7 26.7 31.8 84.0 97 2105 450' N & 20' W of SE corner Final 1 6 110.6 26.9 32.1 83.7 96 Building B, Interior Plumbing 2106 100' N & 20' E of SW corner of pad 2' BFG 2 6 117.7 26.3 28.8 91.4 95 2107 100' N & 20' E of SW corner of pad 1.2' BFG 2 6 116.9 25.9 28.5 91.0 95 2108 100' N & 20' E of SW corner of pad 0.4' BFG 2 6 117.7 26.4 28.9 91.3 95 2109 100' N & 20' E of SW corner of pad Final 3 6 110.9 26.1 30.8 84.8 98 Comments: Datum:Serial No: Test and/or retest results on this report meet project requirements as noted above. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 2 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0162 08/05/14 08/12/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 2 of 2 REINFORCING STEEL OBSERVATIONS REPORT Report Number:94141126.0164 Service Date:08/06/14 8901 Carpenter Frwy., Suite 100 Report Date:08/13/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Reinforcing steel (rebar) placement observation. Terracon Rep.: Daniel Duran Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940003, 07-01-12, Rev.0 Page 1 of 1 tp PROJECT DATA Drawings Utilized:Structural Sheets/Details: S2.1/Building C, Foundation Paving Plan, dated 10/24/13 Locations/Items Observed:Building C, Slab-on-Grade @ A.2 – L.8/1.2 – 2.0 Test Method:Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT Placing Drawings Approved X Bar Length and Shape X Column Tie Spacing & Type Bar Size X Proper Bar Placement X Stirrup Spacing & Type Bar Grade X Properly Tied X Welded Splices Rebar Clean X Dowel Bars in Place X Mechanical Splices Trash & Debris Removed X Proper Bar Supports X Lapped Splices X Number of Bars X Proper Cover/Clearance X Discrepancies/Comments: No discrepancies were noted at the time of this observation. Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0165 08/06/14 08/15/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0344 1422 Plant: Ticket No.: P259 25911008 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.6 0-3 91 82 148.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/06/14 0429 Daniel Duran Clear 50 10 0 0 K.2/3Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg. C, Slab-on-Grade @ A.2-L.8/1.2-2.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/13/14 7 62,760 2 4,990 1 2 4.00 12.57 09/03/14 28 1 3 4.00 12.57 09/03/14 28 1 4 4.00 12.57 09/03/14 28 1 5 4.00 12.57 10/01/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0165 08/06/14 08/15/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0454 1433 Plant: Ticket No.: P259 25911091 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.8 0-3 92 81 148.5 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/06/14 0540 Daniel Duran Clear 170 10 0 0 I.1/1.8Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg. C, Slab-on-Grade @ A.2-L.8/1.2-2.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/13/14 7 66,510 1 5,290 2 2 4.00 12.57 09/03/14 28 2 3 4.00 12.57 09/03/14 28 2 4 4.00 12.57 09/03/14 28 2 5 4.00 12.57 10/01/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0165 08/06/14 08/15/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0536 1256 Plant: Ticket No.: P259 25911152 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.4 0-3 91 80 149.9 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/06/14 0625 Daniel Duran Clear 230 10 0 0 G.1/1.3Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg. C, Slab-on-Grade @ A.2-L.8/1.2-2.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/13/14 7 65,860 5 5,240 3 2 4.00 12.57 09/03/14 28 3 3 4.00 12.57 09/03/14 28 3 4 4.00 12.57 09/03/14 28 3 5 4.00 12.57 10/01/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0165 08/06/14 08/15/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0732 1186 Plant: Ticket No.: P259 25911298 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.2 0-3 90 80 149.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/06/14 0820 Daniel Duran Clear 360 10 10 0 B.2/1.4Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg. C, Slab-on-Grade @ A.2-L.8/1.2-2.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 08/13/14 7 65,600 4 5,220 4 2 4.00 12.57 09/03/14 28 4 3 4.00 12.57 09/03/14 28 4 4 4.00 12.57 09/03/14 28 4 5 4.00 12.57 10/01/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0165 08/06/14 09/04/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0344 1422 Plant: Ticket No.: P259 25911008 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.6 0-3 91 82 148.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/06/14 0429 Daniel Duran Clear 50 10 0 0 K.2/3Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg. C, Slab-on-Grade @ A.2-L.8/1.2-2.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/13/14 7 62,760 2 4,990 1 2 4.00 12.57 09/03/14 28 78,940 3 6,280 1 3 4.00 12.57 09/03/14 28 78,410 4 6,240 1 4 4.00 12.57 09/03/14 28 76,150 4 6,060 Average (28 days) 6,190 1 5 4.00 12.57 10/01/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0165 08/06/14 09/04/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0454 1433 Plant: Ticket No.: P259 25911091 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.8 0-3 92 81 148.5 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/06/14 0540 Daniel Duran Clear 170 10 0 0 I.1/1.8Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg. C, Slab-on-Grade @ A.2-L.8/1.2-2.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/13/14 7 66,510 1 5,290 2 2 4.00 12.57 09/03/14 28 77,180 4 6,140 2 3 4.00 12.57 09/03/14 28 80,330 4 6,390 2 4 4.00 12.57 09/03/14 28 78,120 1 6,220 Average (28 days) 6,250 2 5 4.00 12.57 10/01/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0165 08/06/14 09/04/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0536 1256 Plant: Ticket No.: P259 25911152 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.4 0-3 91 80 149.9 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/06/14 0625 Daniel Duran Clear 230 10 0 0 G.1/1.3Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg. C, Slab-on-Grade @ A.2-L.8/1.2-2.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/13/14 7 65,860 5 5,240 3 2 4.00 12.57 09/03/14 28 76,650 5 6,100 3 3 4.00 12.57 09/03/14 28 78,750 3 6,270 3 4 4.00 12.57 09/03/14 28 75,320 2 5,990 Average (28 days) 6,120 3 5 4.00 12.57 10/01/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0165 08/06/14 09/04/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0732 1186 Plant: Ticket No.: P259 25911298 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.2 0-3 90 80 149.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/06/14 0820 Daniel Duran Clear 360 10 10 0 B.2/1.4Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg. C, Slab-on-Grade @ A.2-L.8/1.2-2.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 08/13/14 7 65,600 4 5,220 4 2 4.00 12.57 09/03/14 28 77,210 5 6,140 4 3 4.00 12.57 09/03/14 28 78,070 2 6,210 4 4 4.00 12.57 09/03/14 28 80,340 3 6,390 Average (28 days) 6,250 4 5 4.00 12.57 10/01/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0165 08/06/14 10/02/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0344 1422 Plant: Ticket No.: P259 25911008 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.6 0-3 91 82 148.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/06/14 0429 Daniel Duran Clear 50 10 0 0 K.2/3Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg. C, Slab-on-Grade @ A.2-L.8/1.2-2.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 08/13/14 7 62,760 2 4,990 1 2 4.00 12.57 09/03/14 28 78,940 3 6,280 1 3 4.00 12.57 09/03/14 28 78,410 4 6,240 1 4 4.00 12.57 09/03/14 28 76,150 4 6,060 Average (28 days) 6,190 1 5 4.00 12.57 10/01/14 56 88,410 4 7,040 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0165 08/06/14 10/02/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0454 1433 Plant: Ticket No.: P259 25911091 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.8 0-3 92 81 148.5 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/06/14 0540 Daniel Duran Clear 170 10 0 0 I.1/1.8Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg. C, Slab-on-Grade @ A.2-L.8/1.2-2.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 08/13/14 7 66,510 1 5,290 2 2 4.00 12.57 09/03/14 28 77,180 4 6,140 2 3 4.00 12.57 09/03/14 28 80,330 4 6,390 2 4 4.00 12.57 09/03/14 28 78,120 1 6,220 Average (28 days) 6,250 2 5 4.00 12.57 10/01/14 56 82,470 2 6,560 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0165 08/06/14 10/02/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0536 1256 Plant: Ticket No.: P259 25911152 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.4 0-3 91 80 149.9 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/06/14 0625 Daniel Duran Clear 230 10 0 0 G.1/1.3Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg. C, Slab-on-Grade @ A.2-L.8/1.2-2.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 08/13/14 7 65,860 5 5,240 3 2 4.00 12.57 09/03/14 28 76,650 5 6,100 3 3 4.00 12.57 09/03/14 28 78,750 3 6,270 3 4 4.00 12.57 09/03/14 28 75,320 2 5,990 Average (28 days) 6,120 3 5 4.00 12.57 10/01/14 56 79,920 5 6,360 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0165 08/06/14 10/02/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0732 1186 Plant: Ticket No.: P259 25911298 Field Test Data Test Air Content (%): Result Specification 5 3-5 1.2 0-3 90 80 149.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:08/06/14 0820 Daniel Duran Clear 360 10 10 0 B.2/1.4Sample Location: Placement Method:Pump Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Bldg. C, Slab-on-Grade @ A.2-L.8/1.2-2.0 Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 08/13/14 7 65,600 4 5,220 4 2 4.00 12.57 09/03/14 28 77,210 5 6,140 4 3 4.00 12.57 09/03/14 28 78,070 2 6,210 4 4 4.00 12.57 09/03/14 28 80,340 3 6,390 Average (28 days) 6,250 4 5 4.00 12.57 10/01/14 56 88,230 3 7,020 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Daniel Duran The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 4CR0001, 11-16-12, Rev.6