Park West Crossing-LR140930Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0270 09/30/14 11/25/14 Revision 3 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10N11501 Redi-Mix Material Information 1226 1204 Plant: Ticket No.:25948125 Field Test Data Test Air Content (%): Result Specification 4 3-5 3.0 0-3 90 84 152.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:09/30/14 1315 Vincent Green 360/370 10 5 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building A, Pier Caps, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/03/14 3 59,050 4 4,700 1 2 4.00 12.57 10/06/14 6 60,840 4 4,840 1 3 4.00 12.57 10/07/14 7 69,290 5 5,510 1 4 4.00 12.57 10/28/14 28 77,060 3 6,130 1 5 4.00 12.57 10/28/14 28 79,240 2 6,310 1 6 4.00 12.57 10/28/14 28 76,210 6 6,070 Average (28 days) 6,170 1 7 4.00 12.57 11/25/14 56 88,700 4 7,060 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 STRUCTURAL STEEL OBSERVATIONS REPORT Report Number:94141126.0272 Service Date:10/02/14 8901 Carpenter Frwy., Suite 100 Report Date:10/07/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Structural steel observations. Terracon Rep.: Oscar R. Esparza, Jr., CWI 00020341 Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 tp On this date, Terracon's representative arrived at the above referenced job site as scheduled for structural steel observations. A visual observation was performed as noted below. A.Building D, Roof Level Framing Between Lines G to K/1 to 5: 1.Joist and girder seat welds were determined to be compliant. 2.Joist bridging was determined to be compliant. STRUCTURAL STEEL OBSERVATIONS REPORT Report Number:94141126.0276 Service Date:10/06/14 8901 Carpenter Frwy., Suite 100 Report Date:10/07/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Structural steel observations. Terracon Rep.: Randy T. Walcker, C.W.I. Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 dgr On this date, Terracon's representative arrived at the above referenced job site as scheduled for structural steel observations. A visual observation was performed as noted below. A.Building D, Roof Level Framing between Lines K-P/1-5: *1.Column anchor bolts, unable to observe due to water coverage. 2.Joist and girder seat welds were determined to be compliant. *3.South wall leave out tilt wall panel bay, structural steel erection not complete at the time of this observation. *4.Joist bridging was not complete at the time of this observation. 5.Joist seat support glug weldments at the tilt wall panel embed plates, (south wall) welds were determined to be compliant. *Noted discrepancies and/or incomplete work. REINFORCING STEEL OBSERVATIONS REPORT Report Number:94141126.0279 Service Date:10/08/14 8901 Carpenter Frwy., Suite 100 Report Date:10/14/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Reinforcing steel (rebar) placement observation. Terracon Rep.: Vincent Green Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940003, 07-01-12, Rev.0 Page 1 of 1 tp PROJECT DATA Drawings Utilized:Civil Sheets/Details: C6.01/Paving Details, dated 04/23/14 Locations/Items Observed:Paving, see attached sketch Test Method:Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT Placing Drawings Approved X Bar Length and Shape X Column Tie Spacing & Type Bar Size X Proper Bar Placement X Stirrup Spacing & Type Bar Grade X Properly Tied X Welded Splices Rebar Clean X Dowel Bars in Place Mechanical Splices Trash & Debris Removed X Proper Bar Supports X Lapped Splices X Number of Bars X Proper Cover/Clearance X Discrepancies/Comments: No discrepancies were noted at the time of this observation. Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0280 10/08/14 10/17/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0413 1445 Plant: Ticket No.: 236 25951956 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 5.7 3-6 87 75 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/08/14 Vincent Green 50/500 10 0 0 Sample #1, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/15/14 7 52,340 5 4,170 1 2 4.00 12.57 11/05/14 28 1 3 4.00 12.57 11/05/14 28 1 4 4.00 12.57 11/05/14 28 1 5 4.00 12.57 12/03/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0280 10/08/14 10/17/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0651 1006 Plant: Ticket No.: 236 25952063 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 5.6 3-6 84 75 145.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/08/14 0732 Vincent Green 150/500 10 0 0 Sample #2, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 10/15/14 7 55,550 2 4,420 2 2 4.00 12.57 11/05/14 28 2 3 4.00 12.57 11/05/14 28 2 4 4.00 12.57 11/05/14 28 2 5 4.00 12.57 12/03/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0280 10/08/14 10/17/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0731 1190 Plant: Ticket No.: 236 25952204 Field Test Data Test Air Content (%): Result Specification 5 3-5 3.5 3-6 83 74 148.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/08/14 0825 Vincent Green 250/500 10 5 0 Sample #3, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 10/15/14 7 45,810 6 3,650 3 2 4.00 12.57 11/05/14 28 3 3 4.00 12.57 11/05/14 28 3 4 4.00 12.57 11/05/14 28 3 5 4.00 12.57 12/03/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0280 10/08/14 10/17/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0850 1191 Plant: Ticket No.: 236 25952333 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 4.9 3-6 85 76 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/08/14 0952 Vincent Green 350/500 10 0 0 Sample #4, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 10/15/14 7 47,820 4 3,810 4 2 4.00 12.57 11/05/14 28 4 3 4.00 12.57 11/05/14 28 4 4 4.00 12.57 11/05/14 28 4 5 4.00 12.57 12/03/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0280 10/08/14 10/17/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 1006 1426 Plant: Ticket No.: 236 25952478 Field Test Data Test Air Content (%): Result Specification 4 3-5 3.8 3-6 85 78 148.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/08/14 1059 Vincent Green 450/500 10 0 0 Sample #5, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 10/15/14 7 53,850 3 4,290 5 2 4.00 12.57 11/05/14 28 5 3 4.00 12.57 11/05/14 28 5 4 4.00 12.57 11/05/14 28 5 5 4.00 12.57 12/03/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0280 10/08/14 11/06/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0413 1445 Plant: Ticket No.: 236 25951956 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 5.7 3-6 87 75 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/08/14 Vincent Green 50/500 10 0 0 Sample #1, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/15/14 7 52,340 5 4,170 1 2 4.00 12.57 11/05/14 28 70,180 4 5,590 1 3 4.00 12.57 11/05/14 28 65,150 4 5,180 1 4 4.00 12.57 11/05/14 28 64,900 4 5,170 Average (28 days) 5,310 1 5 4.00 12.57 12/03/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0280 10/08/14 11/06/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0651 1006 Plant: Ticket No.: 236 25952063 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 5.6 3-6 84 75 145.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/08/14 0732 Vincent Green 150/500 10 0 0 Sample #2, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 10/15/14 7 55,550 2 4,420 2 2 4.00 12.57 11/05/14 28 72,170 4 5,740 2 3 4.00 12.57 11/05/14 28 69,670 4 5,540 2 4 4.00 12.57 11/05/14 28 66,360 4 5,280 Average (28 days) 5,520 2 5 4.00 12.57 12/03/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0280 10/08/14 11/06/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0731 1190 Plant: Ticket No.: 236 25952204 Field Test Data Test Air Content (%): Result Specification 5 3-5 3.5 3-6 83 74 148.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/08/14 0825 Vincent Green 250/500 10 5 0 Sample #3, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 10/15/14 7 45,810 6 3,650 3 2 4.00 12.57 11/05/14 28 60,960 4 4,850 3 3 4.00 12.57 11/05/14 28 61,640 4 4,910 3 4 4.00 12.57 11/05/14 28 61,380 4 4,880 Average (28 days) 4,880 3 5 4.00 12.57 12/03/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0280 10/08/14 11/06/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0850 1191 Plant: Ticket No.: 236 25952333 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 4.9 3-6 85 76 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/08/14 0952 Vincent Green 350/500 10 0 0 Sample #4, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 10/15/14 7 47,820 4 3,810 4 2 4.00 12.57 11/05/14 28 61,580 4 4,900 4 3 4.00 12.57 11/05/14 28 59,940 4 4,770 4 4 4.00 12.57 11/05/14 28 60,940 4 4,850 Average (28 days) 4,840 4 5 4.00 12.57 12/03/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0280 10/08/14 11/06/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 1006 1426 Plant: Ticket No.: 236 25952478 Field Test Data Test Air Content (%): Result Specification 4 3-5 3.8 3-6 85 78 148.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/08/14 1059 Vincent Green 450/500 10 0 0 Sample #5, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 10/15/14 7 53,850 3 4,290 5 2 4.00 12.57 11/05/14 28 68,940 5 5,490 5 3 4.00 12.57 11/05/14 28 64,270 3 5,110 5 4 4.00 12.57 11/05/14 28 65,780 4 5,240 Average (28 days) 5,280 5 5 4.00 12.57 12/03/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0280 10/08/14 12/03/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0413 1445 Plant: Ticket No.: 236 25951956 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 5.7 3-6 87 75 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/08/14 Vincent Green 50/500 10 0 0 Sample #1, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/15/14 7 52,340 5 4,170 1 2 4.00 12.57 11/05/14 28 70,180 4 5,590 1 3 4.00 12.57 11/05/14 28 65,150 4 5,180 1 4 4.00 12.57 11/05/14 28 64,900 4 5,170 Average (28 days) 5,310 1 5 4.00 12.57 12/03/14 56 69,990 5 5,570 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0280 10/08/14 12/03/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0651 1006 Plant: Ticket No.: 236 25952063 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 5.6 3-6 84 75 145.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/08/14 0732 Vincent Green 150/500 10 0 0 Sample #2, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 10/15/14 7 55,550 2 4,420 2 2 4.00 12.57 11/05/14 28 72,170 4 5,740 2 3 4.00 12.57 11/05/14 28 69,670 4 5,540 2 4 4.00 12.57 11/05/14 28 66,360 4 5,280 Average (28 days) 5,520 2 5 4.00 12.57 12/03/14 56 79,780 2 6,350 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0280 10/08/14 12/03/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0731 1190 Plant: Ticket No.: 236 25952204 Field Test Data Test Air Content (%): Result Specification 5 3-5 3.5 3-6 83 74 148.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/08/14 0825 Vincent Green 250/500 10 5 0 Sample #3, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 10/15/14 7 45,810 6 3,650 3 2 4.00 12.57 11/05/14 28 60,960 4 4,850 3 3 4.00 12.57 11/05/14 28 61,640 4 4,910 3 4 4.00 12.57 11/05/14 28 61,380 4 4,880 Average (28 days) 4,880 3 5 4.00 12.57 12/03/14 56 62,890 2 5,010 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0280 10/08/14 12/03/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0850 1191 Plant: Ticket No.: 236 25952333 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 4.9 3-6 85 76 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/08/14 0952 Vincent Green 350/500 10 0 0 Sample #4, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 10/15/14 7 47,820 4 3,810 4 2 4.00 12.57 11/05/14 28 61,580 4 4,900 4 3 4.00 12.57 11/05/14 28 59,940 4 4,770 4 4 4.00 12.57 11/05/14 28 60,940 4 4,850 Average (28 days) 4,840 4 5 4.00 12.57 12/03/14 56 64,670 5 5,150 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0280 10/08/14 12/03/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 1006 1426 Plant: Ticket No.: 236 25952478 Field Test Data Test Air Content (%): Result Specification 4 3-5 3.8 3-6 85 78 148.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/08/14 1059 Vincent Green 450/500 10 0 0 Sample #5, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 10/15/14 7 53,850 3 4,290 5 2 4.00 12.57 11/05/14 28 68,940 5 5,490 5 3 4.00 12.57 11/05/14 28 64,270 3 5,110 5 4 4.00 12.57 11/05/14 28 65,780 4 5,240 Average (28 days) 5,280 5 5 4.00 12.57 12/03/14 56 73,330 2 5,840 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 5CR0001, 11-16-12, Rev.6 STRUCTURAL STEEL OBSERVATIONS REPORT Report Number:94141126.0281 Service Date:10/08/14 8901 Carpenter Frwy., Suite 100 Report Date:10/08/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Structural steel observations. Terracon Rep.: Randy T. Walcker, C.W.I. Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 sbv On this date, Terracon's representative arrived at the above referenced job site as scheduled for structural steel observations. A visual observation was performed as noted below. A.Reinspection Items: 1.Tilt wall panel to pier cap welded connections, four locations were now determined to be compliant. *2.Column anchor bolts, there are still ten locations found to have either missing bolts or no flat washers under the nuts. 3.Joist bridging was now determined to be compliant. *4.South wall leaveout panel bay steel still not erected. B.Initial Inspection Items: *1.Tilt wall panel to panel welded connections, five locations were found to be incomplete. *2.Girder bottom chored extension to column or wall stabilizer plates, one location at East wall @ N/5 was found to be incomplete. *Noted discrepancies and/or incomplete work. STRUCTURAL STEEL OBSERVATIONS REPORT Report Number:94141126.0281 Service Date:10/08/14 8901 Carpenter Frwy., Suite 100 Report Date:11/04/14 Revision 1 - See NOTE Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Structural steel observations. Terracon Rep.: Randy T. Walcker, C.W.I. Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 sbv On this date, Terracon's representative arrived at the above referenced job site as scheduled for structural steel observations. A visual observation was performed as noted below. A.Building D, Roof Level, Framing @ A-P/1-5. Reinspection Items from Reports 94141126.0267, dated 09/29/2014 and Report 94141126.0276, dated 10/06/2014. Also some Initial Inspection Items: 1.Tilt wall panel to pier cap welded connections, four locations were now determined to be compliant. *2.Column anchor bolts, there are still ten locations found to have either missing bolts or no flat washers under the nuts. 3.Joist bridging was now determined to be compliant. *4.South wall leaveout panel bay steel still not erected. B.Building D, Roof Level, Framing @ A-P/1-5. Initial Inspection Items: *1.Tilt wall panel to panel welded connections, five locations were found to be incomplete. *2.Girder bottom chored extension to column or wall stabilizer plates, one location at East wall @ N/5 was found to be incomplete. This job was REVISED on 11/03/2014 to reflect the locations/items inspected which was inadvertently left off of the initial report. *Noted discrepancies and/or incomplete work. REINFORCING STEEL OBSERVATIONS REPORT Report Number:94141126.0284 Service Date:10/09/14 8901 Carpenter Frwy., Suite 100 Report Date:10/17/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Reinforcing steel (rebar) placement observation. Terracon Rep.: Vincent Green Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940003, 07-01-12, Rev.0 Page 1 of 1 sbv PROJECT DATA Drawings Utilized:Sheets/Details: C6.01/Pavement Details, dated 04-23-2014 Locations/Items Observed:Pavement, see attached sketch Test Method:Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT Placing Drawings Approved X Bar Length and Shape X Column Tie Spacing & Type Bar Size X Proper Bar Placement X Stirrup Spacing & Type Bar Grade X Properly Tied X Welded Splices Rebar Clean X Dowel Bars in Place Mechanical Splices Trash & Debris Removed X Proper Bar Supports X Lapped Splices X Number of Bars X Proper Cover/Clearance X Discrepancies/Comments: No discrepancies were noted at the time of this observation. Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0285 10/09/14 10/20/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0407 1445 Plant: Ticket No.: 136 25953085 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.6 3-6 84 77 145.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/09/14 0500 Vincent Green 80/490 10 0 0 Sample #1, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/16/14 7 53,800 4 4,280 1 2 4.00 12.57 11/06/14 28 1 3 4.00 12.57 11/06/14 28 1 4 4.00 12.57 11/06/14 28 1 5 4.00 12.57 12/04/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0285 10/09/14 10/20/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0444 1192 Plant: Ticket No.: 136 25953114 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.3 3-6 85 77 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/09/14 0535 Vincent Green 150/490 10 0 0 Sample #2, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 10/16/14 7 57,810 4 4,600 2 2 4.00 12.57 11/06/14 28 2 3 4.00 12.57 11/06/14 28 2 4 4.00 12.57 11/06/14 28 2 5 4.00 12.57 12/04/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0285 10/09/14 10/20/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0614 1181 Plant: Ticket No.: 136 259531097 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 5.4 3-6 84 76 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/09/14 0657 Vincent Green 290/490 10 0 0 Sample #3, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 10/16/14 7 64,870 4 5,160 3 2 4.00 12.57 11/06/14 28 3 3 4.00 12.57 11/06/14 28 3 4 4.00 12.57 11/06/14 28 3 5 4.00 12.57 12/04/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0285 10/09/14 10/20/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0712 1236 Plant: Ticket No.: 136 25953289 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.4 3-6 85 76 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/09/14 0755 Vincent Green 350/490 10 0 0 Sample #4, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 10/16/14 7 57,920 4 4,610 4 2 4.00 12.57 11/06/14 28 4 3 4.00 12.57 11/06/14 28 4 4 4.00 12.57 11/06/14 28 4 5 4.00 12.57 12/04/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0285 10/09/14 10/20/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0813 1375 Plant: Ticket No.: 136 25953378 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.1 3-6 86 78 147.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/09/14 0923 Vincent Green 460/490 10 0 0 Sample #5, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 10/16/14 7 52,410 4 4,170 5 2 4.00 12.57 11/06/14 28 5 3 4.00 12.57 11/06/14 28 5 4 4.00 12.57 11/06/14 28 5 5 4.00 12.57 12/04/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0285 10/09/14 11/10/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0407 1445 Plant: Ticket No.: 136 25953085 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.6 3-6 84 77 145.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/09/14 0500 Vincent Green 80/490 10 0 0 Sample #1, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/16/14 7 53,800 4 4,280 1 2 4.00 12.57 11/06/14 28 60,070 2 4,780 1 3 4.00 12.57 11/06/14 28 60,370 4 4,800 1 4 4.00 12.57 11/06/14 28 61,290 2 4,880 Average (28 days) 4,820 1 5 4.00 12.57 12/04/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0285 10/09/14 11/10/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0444 1192 Plant: Ticket No.: 136 25953114 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.3 3-6 85 77 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/09/14 0535 Vincent Green 150/490 10 0 0 Sample #2, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 10/16/14 7 57,810 4 4,600 2 2 4.00 12.57 11/06/14 28 64,640 4 5,140 2 3 4.00 12.57 11/06/14 28 68,650 5 5,460 2 4 4.00 12.57 11/06/14 28 64,410 2 5,130 Average (28 days) 5,240 2 5 4.00 12.57 12/04/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0285 10/09/14 11/10/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0614 1181 Plant: Ticket No.: 136 259531097 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 5.4 3-6 84 76 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/09/14 0657 Vincent Green 290/490 10 0 0 Sample #3, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 10/16/14 7 64,870 4 5,160 3 2 4.00 12.57 11/06/14 28 66,020 2 5,250 3 3 4.00 12.57 11/06/14 28 72,930 2 5,800 3 4 4.00 12.57 11/06/14 28 66,810 3 5,320 Average (28 days) 5,460 3 5 4.00 12.57 12/04/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0285 10/09/14 11/10/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0712 1236 Plant: Ticket No.: 136 25953289 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.4 3-6 85 76 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/09/14 0755 Vincent Green 350/490 10 0 0 Sample #4, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 10/16/14 7 57,920 4 4,610 4 2 4.00 12.57 11/06/14 28 68,570 2 5,460 4 3 4.00 12.57 11/06/14 28 68,930 4 5,490 4 4 4.00 12.57 11/06/14 28 65,700 3 5,230 Average (28 days) 5,390 4 5 4.00 12.57 12/04/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0285 10/09/14 11/10/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0813 1375 Plant: Ticket No.: 136 25953378 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.1 3-6 86 78 147.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/09/14 0923 Vincent Green 460/490 10 0 0 Sample #5, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 10/16/14 7 52,410 4 4,170 5 2 4.00 12.57 11/06/14 28 64,250 3 5,110 5 3 4.00 12.57 11/06/14 28 61,760 2 4,920 5 4 4.00 12.57 11/06/14 28 62,810 4 5,000 Average (28 days) 5,010 5 5 4.00 12.57 12/04/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0285 10/09/14 12/05/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0407 1445 Plant: Ticket No.: 136 25953085 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.6 3-6 84 77 145.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/09/14 0500 Vincent Green 80/490 10 0 0 Sample #1, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/16/14 7 53,800 4 4,280 1 2 4.00 12.57 11/06/14 28 60,070 2 4,780 1 3 4.00 12.57 11/06/14 28 60,370 4 4,800 1 4 4.00 12.57 11/06/14 28 61,290 2 4,880 Average (28 days) 4,820 1 5 4.00 12.57 12/04/14 56 65,000 3 5,170 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0285 10/09/14 12/05/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0444 1192 Plant: Ticket No.: 136 25953114 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.3 3-6 85 77 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/09/14 0535 Vincent Green 150/490 10 0 0 Sample #2, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 10/16/14 7 57,810 4 4,600 2 2 4.00 12.57 11/06/14 28 64,640 4 5,140 2 3 4.00 12.57 11/06/14 28 68,650 5 5,460 2 4 4.00 12.57 11/06/14 28 64,410 2 5,130 Average (28 days) 5,240 2 5 4.00 12.57 12/04/14 56 69,680 5 5,550 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0285 10/09/14 12/05/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0614 1181 Plant: Ticket No.: 136 259531097 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 5.4 3-6 84 76 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/09/14 0657 Vincent Green 290/490 10 0 0 Sample #3, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 10/16/14 7 64,870 4 5,160 3 2 4.00 12.57 11/06/14 28 66,020 2 5,250 3 3 4.00 12.57 11/06/14 28 72,930 2 5,800 3 4 4.00 12.57 11/06/14 28 66,810 3 5,320 Average (28 days) 5,460 3 5 4.00 12.57 12/04/14 56 81,190 2 6,460 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0285 10/09/14 12/05/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0712 1236 Plant: Ticket No.: 136 25953289 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.4 3-6 85 76 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/09/14 0755 Vincent Green 350/490 10 0 0 Sample #4, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 10/16/14 7 57,920 4 4,610 4 2 4.00 12.57 11/06/14 28 68,570 2 5,460 4 3 4.00 12.57 11/06/14 28 68,930 4 5,490 4 4 4.00 12.57 11/06/14 28 65,700 3 5,230 Average (28 days) 5,390 4 5 4.00 12.57 12/04/14 56 70,170 4 5,580 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0285 10/09/14 12/05/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0813 1375 Plant: Ticket No.: 136 25953378 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.1 3-6 86 78 147.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/09/14 0923 Vincent Green 460/490 10 0 0 Sample #5, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 10/16/14 7 52,410 4 4,170 5 2 4.00 12.57 11/06/14 28 64,250 3 5,110 5 3 4.00 12.57 11/06/14 28 61,760 2 4,920 5 4 4.00 12.57 11/06/14 28 62,810 4 5,000 Average (28 days) 5,010 5 5 4.00 12.57 12/04/14 56 65,990 2 5,250 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 5CR0001, 11-16-12, Rev.6 REINFORCING STEEL OBSERVATIONS REPORT Report Number:94141126.0287 Service Date:10/10/14 8901 Carpenter Frwy., Suite 100 Report Date:10/17/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Reinforcing steel (rebar) placement observation. Terracon Rep.: Vincent Green Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940003, 07-01-12, Rev.0 Page 1 of 1 sbv PROJECT DATA Drawings Utilized:Sheets/Details: C6.01/Pavement Details, dated 04-23-2014 Locations/Items Observed:Pavement, see attached sketch Test Method:Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT Placing Drawings Approved X Bar Length and Shape X Column Tie Spacing & Type Bar Size X Proper Bar Placement X Stirrup Spacing & Type Bar Grade X Properly Tied X Welded Splices Rebar Clean X Dowel Bars in Place Mechanical Splices Trash & Debris Removed X Proper Bar Supports X Lapped Splices X Number of Bars X Proper Cover/Clearance X Discrepancies/Comments: No discrepancies were noted at the time of this observation. Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0288 10/10/14 10/21/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0256 1185 Plant: Ticket No.: 136 25954096 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.7 3-6 85 76 145.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/10/14 0347 Vincent Green 70/500 10 10 0 Sample #1, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/17/14 7 55,550 1 4,420 1 2 4.00 12.57 11/07/14 28 1 3 4.00 12.57 11/07/14 28 1 4 4.00 12.57 11/07/14 28 1 5 4.00 12.57 12/05/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0288 10/10/14 10/21/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0404 1422 Plant: Ticket No.: 136 25954155 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.5 3-6 85 75 145.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/10/14 0445 Vincent Green 150/500 10 0 0 Sample #2, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 10/17/14 7 52,110 1 4,150 2 2 4.00 12.57 11/07/14 28 2 3 4.00 12.57 11/07/14 28 2 4 4.00 12.57 11/07/14 28 2 5 4.00 12.57 12/05/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0288 10/10/14 10/21/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0455 1192 Plant: Ticket No.: 136 25954216 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.7 3-6 84 74 145.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/10/14 0534 Vincent Green 230/500 10 0 0 Sample #3, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 10/17/14 7 48,560 5 3,860 3 2 4.00 12.57 11/07/14 28 3 3 4.00 12.57 11/07/14 28 3 4 4.00 12.57 11/07/14 28 3 5 4.00 12.57 12/05/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0288 10/10/14 10/21/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0609 Plant: Ticket No.: 136 25954282 Field Test Data Test Air Content (%): Result Specification 5 3-5 4.5 3-6 83 75 147.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/10/14 0651 Vincent Green 350/500 10 10 0 Sample #4, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 10/17/14 7 55,750 4 4,440 4 2 4.00 12.57 11/07/14 28 4 3 4.00 12.57 11/07/14 28 4 4 4.00 12.57 11/07/14 28 4 5 4.00 12.57 12/05/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0288 10/10/14 10/21/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0705 1199 Plant: Ticket No.: 136 25954373 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 4.2 3-6 87 74 148.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/10/14 0757 Vincent Green 450/500 10 10 0 Sample #5, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 10/17/14 7 50,060 4 3,980 5 2 4.00 12.57 11/07/14 28 5 3 4.00 12.57 11/07/14 28 5 4 4.00 12.57 11/07/14 28 5 5 4.00 12.57 12/05/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0288 10/10/14 11/10/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0256 1185 Plant: Ticket No.: 136 25954096 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.7 3-6 85 76 145.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/10/14 0347 Vincent Green 70/500 10 10 0 Sample #1, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/17/14 7 55,550 1 4,420 1 2 4.00 12.57 11/07/14 28 67,220 4 5,350 1 3 4.00 12.57 11/07/14 28 66,680 5 5,310 1 4 4.00 12.57 11/07/14 28 62,320 2 4,960 Average (28 days) 5,210 1 5 4.00 12.57 12/05/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0288 10/10/14 11/10/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0404 1422 Plant: Ticket No.: 136 25954155 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.5 3-6 85 75 145.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/10/14 0445 Vincent Green 150/500 10 0 0 Sample #2, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 10/17/14 7 52,110 1 4,150 2 2 4.00 12.57 11/07/14 28 62,000 3 4,930 2 3 4.00 12.57 11/07/14 28 63,390 2 5,040 2 4 4.00 12.57 11/07/14 28 59,260 3 4,720 Average (28 days) 4,900 2 5 4.00 12.57 12/05/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0288 10/10/14 11/10/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0455 1192 Plant: Ticket No.: 136 25954216 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.7 3-6 84 74 145.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/10/14 0534 Vincent Green 230/500 10 0 0 Sample #3, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 10/17/14 7 48,560 5 3,860 3 2 4.00 12.57 11/07/14 28 57,780 2 4,600 3 3 4.00 12.57 11/07/14 28 59,260 3 4,720 3 4 4.00 12.57 11/07/14 28 53,730 4 4,280 Average (28 days) 4,530 3 5 4.00 12.57 12/05/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0288 10/10/14 11/10/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0609 Plant: Ticket No.: 136 25954282 Field Test Data Test Air Content (%): Result Specification 5 3-5 4.5 3-6 83 75 147.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/10/14 0651 Vincent Green 350/500 10 10 0 Sample #4, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 10/17/14 7 55,750 4 4,440 4 2 4.00 12.57 11/07/14 28 67,330 4 5,360 4 3 4.00 12.57 11/07/14 28 67,290 2 5,360 4 4 4.00 12.57 11/07/14 28 64,450 4 5,130 Average (28 days) 5,280 4 5 4.00 12.57 12/05/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0288 10/10/14 11/10/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0705 1199 Plant: Ticket No.: 136 25954373 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 4.2 3-6 87 74 148.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/10/14 0757 Vincent Green 450/500 10 10 0 Sample #5, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 10/17/14 7 50,060 4 3,980 5 2 4.00 12.57 11/07/14 28 60,570 3 4,820 5 3 4.00 12.57 11/07/14 28 62,640 2 4,990 5 4 4.00 12.57 11/07/14 28 61,680 4 4,910 Average (28 days) 4,910 5 5 4.00 12.57 12/05/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0288 10/10/14 12/08/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0256 1185 Plant: Ticket No.: 136 25954096 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.7 3-6 85 76 145.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/10/14 0347 Vincent Green 70/500 10 10 0 Sample #1, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/17/14 7 55,550 1 4,420 1 2 4.00 12.57 11/07/14 28 67,220 4 5,350 1 3 4.00 12.57 11/07/14 28 66,680 5 5,310 1 4 4.00 12.57 11/07/14 28 62,320 2 4,960 Average (28 days) 5,210 1 5 4.00 12.57 12/05/14 56 68,700 5 5,470 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0288 10/10/14 12/08/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0404 1422 Plant: Ticket No.: 136 25954155 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.5 3-6 85 75 145.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/10/14 0445 Vincent Green 150/500 10 0 0 Sample #2, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 10/17/14 7 52,110 1 4,150 2 2 4.00 12.57 11/07/14 28 62,000 3 4,930 2 3 4.00 12.57 11/07/14 28 63,390 2 5,040 2 4 4.00 12.57 11/07/14 28 59,260 3 4,720 Average (28 days) 4,900 2 5 4.00 12.57 12/05/14 56 63,990 4 5,090 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0288 10/10/14 12/08/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0455 1192 Plant: Ticket No.: 136 25954216 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.7 3-6 84 74 145.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/10/14 0534 Vincent Green 230/500 10 0 0 Sample #3, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 10/17/14 7 48,560 5 3,860 3 2 4.00 12.57 11/07/14 28 57,780 2 4,600 3 3 4.00 12.57 11/07/14 28 59,260 3 4,720 3 4 4.00 12.57 11/07/14 28 53,730 4 4,280 Average (28 days) 4,530 3 5 4.00 12.57 12/05/14 56 65,930 6 5,250 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0288 10/10/14 12/08/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0609 Plant: Ticket No.: 136 25954282 Field Test Data Test Air Content (%): Result Specification 5 3-5 4.5 3-6 83 75 147.2 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/10/14 0651 Vincent Green 350/500 10 10 0 Sample #4, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 10/17/14 7 55,750 4 4,440 4 2 4.00 12.57 11/07/14 28 67,330 4 5,360 4 3 4.00 12.57 11/07/14 28 67,290 2 5,360 4 4 4.00 12.57 11/07/14 28 64,450 4 5,130 Average (28 days) 5,280 4 5 4.00 12.57 12/05/14 56 71,570 2 5,700 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0288 10/10/14 12/08/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0705 1199 Plant: Ticket No.: 136 25954373 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 4.2 3-6 87 74 148.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/10/14 0757 Vincent Green 450/500 10 10 0 Sample #5, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 10/17/14 7 50,060 4 3,980 5 2 4.00 12.57 11/07/14 28 60,570 3 4,820 5 3 4.00 12.57 11/07/14 28 62,640 2 4,990 5 4 4.00 12.57 11/07/14 28 61,680 4 4,910 Average (28 days) 4,910 5 5 4.00 12.57 12/05/14 56 63,170 4 5,030 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 5CR0001, 11-16-12, Rev.6 FOUNDATION OBSERVATIONS REPORT Report Number:94141126.0289 Service Date:10/10/14 8901 Carpenter Frwy., Suite 100 Report Date:10/14/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Drilled pier observation. Terracon Rep.: Tyrece Lewis Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 sbv On this date, Terracon's representative arrived at the above referenced job site as scheduled for straight shaft pier observation. See the attached sheet(s) for recorded data. NOTE:The casing for Pier # 4 got stuck and was unable to be removed. Concrete was left short from the top elevation of concrete due to the casing getting stuck. REPORT OF DRILLED PIERS Project: Park West Crossing - Creek Piers Report No.: 94141126.0289 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd, Coppell, TX Date of Service: 10/10/14 Project No.: 94141126 Technician: T. Lewis Driller: Big Dog Drillers Page: 1 of 1 Pier Identification 1 2 3 4 Pier Diameter (in.)24 24 18 18 Top of Ground Elevation (ft.)N/A N/A N/A N/A Top of Pier Elevation (ft.)N/A N/A N/A N/A Depth to Bearing Stratum from Ground (ft.)11.8 7.6 10.6 21.3 Depth of Pier from Ground (ft.)15.8 11.8 14.6 25.3 Required Penetration (ft.)4.0 4.0 4.0 4.0 Actual Penetration (ft.)4.0 4.2 4.0 4.0 Depth from Top of Concrete (ft.)15.8 11.8 14.6 See Note Condition of Bottom (wet or dry)Dry Dry Dry Dry Plumb Within Tolerance (yes or no)Yes Yes Yes Yes Casing Diameter (in.) N/A N/A N/A N/A Cased Depth (ft.)N/A N/A N/A N/A Number of Vertical Bars (ea.)6 6 6 6 Reinforcing Bar Size (#)6 6 6 6 Length of Vertical Bars (ft.)20.6 20.2 20.5 28.0 Time Drilling was Completed 0935 0946 1025 1203 Time Concrete was Placed 1522 1524 1530 See Note R940001, 08-05-14 Rev.4 8901 Carpenter Frwy.,Suite #100 Dallas,Texas 75247 (214)630-1010 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0290 10/10/14 10/21/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11524 Redi-Mix Material Information 1329 1377 Plant: Ticket No.: 259 2594925 Field Test Data Test Air Content (%): Result Specification 5 3/4 5-7 2.3 0-3 92 89 145.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/10/14 1435 Tyrece Lewis Cloudy 5/5 5 0 0 Piers #1-#4Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Creek Piers, see Foundation Observations Report No. 94141126.0289, dated 10/10/14, for pier information Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/17/14 7 58,350 4 4,640 1 2 4.00 12.57 11/07/14 28 1 3 4.00 12.57 11/07/14 28 1 4 4.00 12.57 11/07/14 28 1 5 4.00 12.57 12/05/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Tyrece Lewis The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0290 10/10/14 11/10/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11524 Redi-Mix Material Information 1329 1377 Plant: Ticket No.: 259 2594925 Field Test Data Test Air Content (%): Result Specification 5 3/4 5-7 2.3 0-3 92 89 145.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/10/14 1435 Tyrece Lewis Cloudy 5/5 5 0 0 Piers #1-#4Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Creek Piers, see Foundation Observations Report No. 94141126.0289, dated 10/10/14, for pier information Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/17/14 7 58,350 4 4,640 1 2 4.00 12.57 11/07/14 28 70,270 4 5,590 1 3 4.00 12.57 11/07/14 28 68,030 2 5,410 1 4 4.00 12.57 11/07/14 28 76,300 3 6,070 Average (28 days) 5,690 1 5 4.00 12.57 12/05/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Tyrece Lewis The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0290 10/10/14 12/05/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11524 Redi-Mix Material Information 1329 1377 Plant: Ticket No.: 259 2594925 Field Test Data Test Air Content (%): Result Specification 5 3/4 5-7 2.3 0-3 92 89 145.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/10/14 1435 Tyrece Lewis Cloudy 5/5 5 0 0 Piers #1-#4Sample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Creek Piers, see Foundation Observations Report No. 94141126.0289, dated 10/10/14, for pier information Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/17/14 7 58,350 4 4,640 1 2 4.00 12.57 11/07/14 28 70,270 4 5,590 1 3 4.00 12.57 11/07/14 28 68,030 2 5,410 1 4 4.00 12.57 11/07/14 28 76,300 3 6,070 Average (28 days) 5,690 1 5 4.00 12.57 12/05/14 56 77,610 3 6,180 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Tyrece Lewis The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 STRUCTURAL STEEL OBSERVATIONS REPORT Report Number:94141126.0291 Service Date:10/10/14 8901 Carpenter Frwy., Suite 100 Report Date:10/10/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Structural steel observations. Terracon Rep.: Randy T. Walcker, C.W.I. Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 dgr On this date, Terracon's representative arrived at the above referenced job site as scheduled for structural steel observations. A visual observation was performed as noted below. A.Building D, Roof Level Framing between Lines A-F/1-5: 1.Perimeter metal deck support angle top side welds to the tilt wall panel embed plates were determined to be compliant. 2.Metal deck installation, puddle welds and side lap screws were determined to be compliant. B.Building C, Roof Level Framing between Lines G-M/1-4: 1.Column anchor bolts were determined to be compliant. *2.Joist and girder seat welds, 1 joist was erected at Line M/1, field fix required. 3.Joist seat support lug weldments along Line M/1-4 at the tilt wall panel embed. *4.Tilt wall panel to pier cap welded connections were determined to be compliant. The north wall leaveout panel was not complete. This observation included all four wall (entire building) between Lines A-M/1-4. *Noted discrepancies and/or incomplete work. STRUCTURAL STEEL OBSERVATIONS REPORT Report Number:94141126.0295 Service Date:10/14/14 8901 Carpenter Frwy., Suite 100 Report Date:10/20/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Structural steel observations. Terracon Rep.: Randy T. Walcker, C.W.I. Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 tp On this date, Terracon's representative arrived at the above referenced job site as scheduled for structural steel observations. A visual observation was performed as noted below. A.Building D, Roof Level Framing: 1.Upon arrival at the project site, Terracon’s representative was informed by the metal deck installer that the mid-section was not ready for observation at this time. B.Building C, Roof Level Framing: 1.Upon arrival at project site, Terracon’s representative was informed by the steel erector that the north half section was not ready for observation at this time. Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0296 10/15/14 10/24/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11524 Redi-Mix Material Information 1359 1236 Plant: Ticket No.: 136 25956380 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 3.9 3-6 88 82 148.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/15/14 1500 Homero Gonzalez Clear 10/10 10 0 0 Headwall & Slab @ Line BSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Headwall & Slab @ Lines A, B, & CPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/22/14 7 46,700 2 3,720 1 2 4.00 12.57 11/12/14 28 1 3 4.00 12.57 11/12/14 28 1 4 4.00 12.57 11/12/14 28 1 5 4.00 12.57 12/10/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Homero Gonzalez The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0296 10/15/14 11/13/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11524 Redi-Mix Material Information 1359 1236 Plant: Ticket No.: 136 25956380 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 3.9 3-6 88 82 148.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/15/14 1500 Homero Gonzalez Clear 10/10 10 0 0 Headwall & Slab @ Line BSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Headwall & Slab @ Lines A, B, & CPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/22/14 7 46,700 2 3,720 1 2 4.00 12.57 11/12/14 28 61,400 5 4,890 1 3 4.00 12.57 11/12/14 28 61,610 4 4,900 1 4 4.00 12.57 11/12/14 28 60,390 2 4,810 Average (28 days) 4,870 1 5 4.00 12.57 12/10/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Homero Gonzalez The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0296 10/15/14 12/10/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11524 Redi-Mix Material Information 1359 1236 Plant: Ticket No.: 136 25956380 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 3.9 3-6 88 82 148.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/15/14 1500 Homero Gonzalez Clear 10/10 10 0 0 Headwall & Slab @ Line BSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Headwall & Slab @ Lines A, B, & CPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/22/14 7 46,700 2 3,720 1 2 4.00 12.57 11/12/14 28 61,400 5 4,890 1 3 4.00 12.57 11/12/14 28 61,610 4 4,900 1 4 4.00 12.57 11/12/14 28 60,390 2 4,810 Average (28 days) 4,870 1 5 4.00 12.57 12/10/14 56 66,030 2 5,260 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Homero Gonzalez The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 STRUCTURAL STEEL OBSERVATIONS REPORT Report Number:94141126.0297 Service Date:10/16/14 8901 Carpenter Frwy., Suite 100 Report Date:10/17/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Structural steel observations. Terracon Rep.: Randy T. Walcker, C.W.I. Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 sbv On this date, Terracon's representative arrived at the above referenced job site as scheduled for structural steel observations. A visual observation was performed as noted below. A.Building D, Roof Level Framing @ F-K/1-5: 1.Perimeter metal deck support angle top side welds at the tilt wall panel embed plates were determined to be compliant. 2.Middle section, metal deck installation, puddle welds and side up screws were determined to be compliant. B.Building C, Roof Level Framing @ A-G/1-4 *1.Column anchor bolts @ G/2 was found to have loose nuts and missing flat washers. *2.Joist and girder seat welds were determined to be compliant with the exception of a joist seat requiring fixing at the Northwest corner @ A/1. *3.Leave out panel erection not complete. 4.Joist bridging was determined to be compliant. 5.Joist seat support lug weldment at line A, tilt wall panel embed plates were determined to be compliant. *Noted discrepancies and/or incomplete work. FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0298 10/16/14 10/23/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Building D, Slab Leaveouts 2129 Approx 200' S of N end of bldg 3' BFG 1 6 114.1 24.2 26.9 89.9 93* 2130 Approx 185' S of N end of bldg 2' BFG 1 6 119.0 26.2 28.2 92.8 96 2131 Approx 210' S of N end of bldg 1' BFG 1 6 116.9 25.5 27.9 91.4 95 2132 Approx 100' S of N end of bldg 1' BFG 1 6 115.9 24.7 27.1 91.2 95 Comments: Datum:BFG = Below final grade Serial No:24412 Test and/or retest results on this report meet project requirements as noted above. NOTE: Terracon recommends passing Test #2129 above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor:Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Daniel Jordan ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 1 STRUCTURAL STEEL OBSERVATIONS REPORT Report Number:94141126.0300 Service Date:10/20/14 8901 Carpenter Frwy., Suite 100 Report Date:10/20/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Structural steel observations. Terracon Rep.: Randy T. Walcker, C.W.I. Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 sbv On this date, Terracon's representative arrived at the above referenced job site as scheduled for structural steel observations. A visual observation was performed as noted below. A.Building D, Roof Level @ K-P/1-5: 1.Perimeter metal deck support angle top side welds at the tilt wall panel embedded plates were determined to be compliant. 2.Metal deck installation, puddle welds and side lap screws were determined to be compliant. 3.Reinspection item from report dated 10-18-2014, all column anchor bolt locations @ A-P/1-5 were now determined to be compliant . B.Building B, Foundation Level @ A-H/1-4: *1.Tilt wall panel to pier cap welds, the following locations were noted to be incomplete. *AA.South Wall, Line H, Leave out panel plus one other location. C.Building A, Foundation Level @ A-G/1-4: *1.Tilt wall panels to pier cap welds, the following locations were noted to be incomplete: *AA.North Wall, Line A, leave out panel. *BB.East Wall, Line 4, three locations were incomplete near Southeast corner. *Noted discrepancies and/or incomplete work. FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0302 10/20/14 10/23/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Building D, Slab Leaveouts along West Side 2133 75' N of SW corner 2' BFG 1 6 115.4 26.7 30.1 88.7 92 2134 125' N of SW corner 2' BFG 1 6 114.5 24.5 27.2 90.0 94 2135 170' N of SW corner 1' BFG 1 6 113.6 24.9 28.1 88.7 92 2136 225' N of SW corner 1' BFG 1 6 114.5 25.6 28.8 88.9 92 2137 280' N of SW corner FG 1 6 114.6 25.8 29.0 88.8 92 2138 370' N of SW corner FG 1 6 115.7 24.8 27.3 90.9 94 Comments: Datum: BFG - Below final grade & FG - Final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Mr. Marvin (Subcontractor) Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Kudret Aksu ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 1 REINFORCING STEEL OBSERVATIONS REPORT Report Number:94141126.0303 Service Date:10/21/14 8901 Carpenter Frwy., Suite 100 Report Date:10/29/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Reinforcing steel (rebar) placement observation. Terracon Rep.: Vincent Green Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940004, 07-01-12, Rev.0 Page 1 of 1 sbv PROJECT DATA Drawings Utilized:Sheets/Details: C6.01/Paving Details, dated 04-23-2014 Locations/Items Observed:Pavement, see attached sketch Test Method:Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT Placing Drawings Approved X Length and Shape X Column Tie Spacing & Type Bar and Cable Size X Proper Placement X Stirrup Spacing & Type Bar and Cable Grade X Properly Tied X Cables Properly Wrapped Rebar and Cables Clean X Dowel Bars in Place Mechanical Splices Trash & Debris Removed X Proper Supports Lapped Splices X Number of Bars and Cables X Proper Cover/Clearance X Proper Drape of Cables Discrepancies/Comments: No discrepancies were noted at the time of this observation. Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0304 10/21/14 10/30/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0344 1185 Plant: Ticket No.: 259 25959560 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.9 3-6 75 63 144.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/21/14 0440 Vincent Green 40/500 10 0 0 Sample #1, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/28/14 7 52,760 1 4,200 1 2 4.00 12.57 11/18/14 28 1 3 4.00 12.57 11/18/14 28 1 4 4.00 12.57 11/18/14 28 1 5 4.00 12.57 12/16/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0304 10/21/14 10/30/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0453 1377 Plant: Ticket No.: 259 259959633 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 5.5 3-6 73 62 145.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/21/14 0554 Vincent Green 140/500 10 0 0 Sample #2, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 10/28/14 7 53,630 6 4,270 2 2 4.00 12.57 11/18/14 28 2 3 4.00 12.57 11/18/14 28 2 4 4.00 12.57 11/18/14 28 2 5 4.00 12.57 12/16/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0304 10/21/14 10/30/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0607 1256 Plant: Ticket No.: 259 25959700 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.4 3-6 74 61 145.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/21/14 0656 Vincent Green 240/500 10 0 0 Sample #3, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 10/28/14 7 58,620 5 4,670 3 2 4.00 12.57 11/18/14 28 3 3 4.00 12.57 11/18/14 28 3 4 4.00 12.57 11/18/14 28 3 5 4.00 12.57 12/16/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0304 10/21/14 10/30/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0714 1182 Plant: Ticket No.: 259 25959844 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 4.7 3-6 77 66 146.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/21/14 0842 Vincent Green 350/500 10 0 0 Sample #4, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 10/28/14 7 53,440 4 4,250 4 2 4.00 12.57 11/18/14 28 4 3 4.00 12.57 11/18/14 28 4 4 4.00 12.57 11/18/14 28 4 5 4.00 12.57 12/16/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0304 10/21/14 10/30/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0950 1182 Plant: Ticket No.: 259 25960016 Field Test Data Test Air Content (%): Result Specification 4 3-5 4.9 3-6 78 64 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/21/14 1039 Vincent Green 460/500 10 0 0 Sample #5, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 10/28/14 7 52,710 4 4,200 5 2 4.00 12.57 11/18/14 28 5 3 4.00 12.57 11/18/14 28 5 4 4.00 12.57 11/18/14 28 5 5 4.00 12.57 12/16/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0304 10/21/14 11/18/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0344 1185 Plant: Ticket No.: 259 25959560 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.9 3-6 75 63 144.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/21/14 0440 Vincent Green 40/500 10 0 0 Sample #1, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/28/14 7 52,760 1 4,200 1 2 4.00 12.57 11/18/14 28 64,900 4 5,170 1 3 4.00 12.57 11/18/14 28 67,890 4 5,400 1 4 4.00 12.57 11/18/14 28 64,750 4 5,150 Average (28 days) 5,240 1 5 4.00 12.57 12/16/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0304 10/21/14 11/18/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0453 1377 Plant: Ticket No.: 259 259959633 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 5.5 3-6 73 62 145.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/21/14 0554 Vincent Green 140/500 10 0 0 Sample #2, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 10/28/14 7 53,630 6 4,270 2 2 4.00 12.57 11/18/14 28 71,240 4 5,670 2 3 4.00 12.57 11/18/14 28 66,400 5 5,280 2 4 4.00 12.57 11/18/14 28 68,120 4 5,420 Average (28 days) 5,460 2 5 4.00 12.57 12/16/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0304 10/21/14 11/18/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0607 1256 Plant: Ticket No.: 259 25959700 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.4 3-6 74 61 145.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/21/14 0656 Vincent Green 240/500 10 0 0 Sample #3, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 10/28/14 7 58,620 5 4,670 3 2 4.00 12.57 11/18/14 28 68,130 4 5,420 3 3 4.00 12.57 11/18/14 28 65,360 4 5,200 3 4 4.00 12.57 11/18/14 28 65,420 4 5,210 Average (28 days) 5,280 3 5 4.00 12.57 12/16/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0304 10/21/14 11/18/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0714 1182 Plant: Ticket No.: 259 25959844 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 4.7 3-6 77 66 146.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/21/14 0842 Vincent Green 350/500 10 0 0 Sample #4, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 10/28/14 7 53,440 4 4,250 4 2 4.00 12.57 11/18/14 28 61,800 4 4,920 4 3 4.00 12.57 11/18/14 28 61,150 4 4,870 4 4 4.00 12.57 11/18/14 28 65,310 4 5,200 Average (28 days) 5,000 4 5 4.00 12.57 12/16/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0304 10/21/14 11/18/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0950 1182 Plant: Ticket No.: 259 25960016 Field Test Data Test Air Content (%): Result Specification 4 3-5 4.9 3-6 78 64 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/21/14 1039 Vincent Green 460/500 10 0 0 Sample #5, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 10/28/14 7 52,710 4 4,200 5 2 4.00 12.57 11/18/14 28 5 3 4.00 12.57 11/18/14 28 5 4 4.00 12.57 11/18/14 28 5 5 4.00 12.57 12/16/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0304 10/21/14 11/19/14 Revision 2 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0344 1185 Plant: Ticket No.: 259 25959560 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.9 3-6 75 63 144.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/21/14 0440 Vincent Green 40/500 10 0 0 Sample #1, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/28/14 7 52,760 1 4,200 1 2 4.00 12.57 11/18/14 28 64,900 4 5,170 1 3 4.00 12.57 11/18/14 28 67,890 4 5,400 1 4 4.00 12.57 11/18/14 28 64,750 4 5,150 Average (28 days) 5,240 1 5 4.00 12.57 12/16/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0304 10/21/14 11/19/14 Revision 2 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0453 1377 Plant: Ticket No.: 259 259959633 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 5.5 3-6 73 62 145.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/21/14 0554 Vincent Green 140/500 10 0 0 Sample #2, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 10/28/14 7 53,630 6 4,270 2 2 4.00 12.57 11/18/14 28 71,240 4 5,670 2 3 4.00 12.57 11/18/14 28 66,400 5 5,280 2 4 4.00 12.57 11/18/14 28 68,120 4 5,420 Average (28 days) 5,460 2 5 4.00 12.57 12/16/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0304 10/21/14 11/19/14 Revision 2 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0607 1256 Plant: Ticket No.: 259 25959700 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.4 3-6 74 61 145.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/21/14 0656 Vincent Green 240/500 10 0 0 Sample #3, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 10/28/14 7 58,620 5 4,670 3 2 4.00 12.57 11/18/14 28 68,130 4 5,420 3 3 4.00 12.57 11/18/14 28 65,360 4 5,200 3 4 4.00 12.57 11/18/14 28 65,420 4 5,210 Average (28 days) 5,280 3 5 4.00 12.57 12/16/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0304 10/21/14 11/19/14 Revision 2 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0714 1182 Plant: Ticket No.: 259 25959844 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 4.7 3-6 77 66 146.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/21/14 0842 Vincent Green 350/500 10 0 0 Sample #4, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 10/28/14 7 53,440 4 4,250 4 2 4.00 12.57 11/18/14 28 61,800 4 4,920 4 3 4.00 12.57 11/18/14 28 61,150 4 4,870 4 4 4.00 12.57 11/18/14 28 65,310 4 5,200 Average (28 days) 5,000 4 5 4.00 12.57 12/16/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0304 10/21/14 11/19/14 Revision 2 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0950 1182 Plant: Ticket No.: 259 25960016 Field Test Data Test Air Content (%): Result Specification 4 3-5 4.9 3-6 78 64 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/21/14 1039 Vincent Green 460/500 10 0 0 Sample #5, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 10/28/14 7 52,710 4 4,200 5 2 4.00 12.57 11/18/14 28 65,520 4 5,210 5 3 4.00 12.57 11/18/14 28 64,850 4 5,160 5 4 4.00 12.57 11/18/14 28 60,110 4 4,780 Average (28 days) 5,050 5 5 4.00 12.57 12/16/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0304 10/21/14 12/17/14 Revision 3 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0344 1185 Plant: Ticket No.: 259 25959560 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.9 3-6 75 63 144.0 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/21/14 0440 Vincent Green 40/500 10 0 0 Sample #1, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/28/14 7 52,760 1 4,200 1 2 4.00 12.57 11/18/14 28 64,900 4 5,170 1 3 4.00 12.57 11/18/14 28 67,890 4 5,400 1 4 4.00 12.57 11/18/14 28 64,750 4 5,150 Average (28 days) 5,240 1 5 4.00 12.57 12/16/14 56 68,040 3 5,410 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0304 10/21/14 12/17/14 Revision 3 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0453 1377 Plant: Ticket No.: 259 259959633 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 5.5 3-6 73 62 145.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/21/14 0554 Vincent Green 140/500 10 0 0 Sample #2, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 10/28/14 7 53,630 6 4,270 2 2 4.00 12.57 11/18/14 28 71,240 4 5,670 2 3 4.00 12.57 11/18/14 28 66,400 5 5,280 2 4 4.00 12.57 11/18/14 28 68,120 4 5,420 Average (28 days) 5,460 2 5 4.00 12.57 12/16/14 56 68,400 2 5,440 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0304 10/21/14 12/17/14 Revision 3 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0607 1256 Plant: Ticket No.: 259 25959700 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.4 3-6 74 61 145.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/21/14 0656 Vincent Green 240/500 10 0 0 Sample #3, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 10/28/14 7 58,620 5 4,670 3 2 4.00 12.57 11/18/14 28 68,130 4 5,420 3 3 4.00 12.57 11/18/14 28 65,360 4 5,200 3 4 4.00 12.57 11/18/14 28 65,420 4 5,210 Average (28 days) 5,280 3 5 4.00 12.57 12/16/14 56 73,950 5 5,890 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0304 10/21/14 12/17/14 Revision 3 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0714 1182 Plant: Ticket No.: 259 25959844 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 4.7 3-6 77 66 146.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/21/14 0842 Vincent Green 350/500 10 0 0 Sample #4, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 10/28/14 7 53,440 4 4,250 4 2 4.00 12.57 11/18/14 28 61,800 4 4,920 4 3 4.00 12.57 11/18/14 28 61,150 4 4,870 4 4 4.00 12.57 11/18/14 28 65,310 4 5,200 Average (28 days) 5,000 4 5 4.00 12.57 12/16/14 56 65,390 2 5,200 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 5CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0304 10/21/14 12/17/14 Revision 3 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0950 1182 Plant: Ticket No.: 259 25960016 Field Test Data Test Air Content (%): Result Specification 4 3-5 4.9 3-6 78 64 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/21/14 1039 Vincent Green 460/500 10 0 0 Sample #5, see attached sketchSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 10/28/14 7 52,710 4 4,200 5 2 4.00 12.57 11/18/14 28 65,520 4 5,210 5 3 4.00 12.57 11/18/14 28 64,850 4 5,160 5 4 4.00 12.57 11/18/14 28 60,110 4 4,780 Average (28 days) 5,050 5 5 4.00 12.57 12/16/14 56 68,210 3 5,430 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 5CR0001, 11-16-12, Rev.6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0305 10/21/14 10/23/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Building D, Slab Leaveout 2139 100' N & 1' E of SW corner 1' BFG 1 6 117.4 26.3 28.9 91.1 95 2140 150' N & 1' E of Sw corner 1' BFG 1 6 118.2 26.8 29.3 91.4 95 Comments: Datum: BFG - Below final grade Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor:Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 1 REINFORCING STEEL OBSERVATIONS REPORT Report Number:94141126.0306 Service Date:10/22/14 8901 Carpenter Frwy., Suite 100 Report Date:10/29/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Reinforcing steel (rebar) placement observation. Terracon Rep.: Vincent Green Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940004, 07-01-12, Rev.0 Page 1 of 1 sbv PROJECT DATA Drawings Utilized:Sheets/Details: C.6.01/Paving Details, dated 04-23-2014 Locations/Items Observed:Pavement, see attached sketch Test Method:Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT Placing Drawings Approved X Length and Shape X Column Tie Spacing & Type Bar and Cable Size X Proper Placement X Stirrup Spacing & Type Bar and Cable Grade X Properly Tied X Cables Properly Wrapped Rebar and Cables Clean X Dowel Bars in Place Mechanical Splices Trash & Debris Removed X Proper Supports X Lapped Splices X Number of Bars and Cables X Proper Cover/Clearance X Proper Drape of Cables Discrepancies/Comments: No discrepancies were noted at the time of this observation. Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0307 10/22/14 10/31/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0347 1391 Plant: Ticket No.: 259 25960678 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 5.1 3-6 76 61 142.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/22/14 0445 Vincent Green 50/580 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/29/14 7 46,560 5 3,710 1 2 4.00 12.57 11/19/14 28 1 3 4.00 12.57 11/19/14 28 1 4 4.00 12.57 11/19/14 28 1 5 4.00 12.57 12/17/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0307 10/22/14 10/31/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0501 1375 Plant: Ticket No.: 259 25960762 Field Test Data Test Air Content (%): Result Specification 5 3-5 4.4 3-6 74 59 148.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/22/14 0615 Vincent Green 140/580 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 10/29/14 7 42,790 5 3,410 2 2 4.00 12.57 11/19/14 28 2 3 4.00 12.57 11/19/14 28 2 4 4.00 12.57 11/19/14 28 2 5 4.00 12.57 12/17/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0307 10/22/14 10/31/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0631 1375 Plant: Ticket No.: 259 25960881 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 4.6 3-6 75 62 149.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/22/14 0750 Vincent Green 240/580 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 10/29/14 7 46,870 4 3,730 3 2 4.00 12.57 11/19/14 28 3 3 4.00 12.57 11/19/14 28 3 4 4.00 12.57 11/19/14 28 3 5 4.00 12.57 12/17/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0307 10/22/14 10/31/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0818 1191 Plant: Ticket No.: 259 25961035 Field Test Data Test Air Content (%): Result Specification 5 3-5 4.5 3-6 78 66 146.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/22/14 0901 Vincent Green 350/580 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 10/29/14 7 41,470 6 3,300 4 2 4.00 12.57 11/19/14 28 4 3 4.00 12.57 11/19/14 28 4 4 4.00 12.57 11/19/14 28 4 5 4.00 12.57 12/17/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0307 10/22/14 10/31/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0946 1287 Plant: Ticket No.: 259 25961185 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.5 3-6 77 65 145.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/22/14 1040 Vincent Green 440/580 10 5 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 10/29/14 7 41,410 4 3,300 5 2 4.00 12.57 11/19/14 28 5 3 4.00 12.57 11/19/14 28 5 4 4.00 12.57 11/19/14 28 5 5 4.00 12.57 12/17/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0307 10/22/14 10/31/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 1147 1433 Plant: Ticket No.: 259 25961417 Field Test Data Test Air Content (%): Result Specification 4 3-5 4.7 3-6 80 74 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/22/14 1236 Vincent Green 550/580 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 6 1 4.00 12.57 10/29/14 7 45,160 4 3,590 6 2 4.00 12.57 11/19/14 28 6 3 4.00 12.57 11/19/14 28 6 4 4.00 12.57 11/19/14 28 6 5 4.00 12.57 12/17/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0307 10/22/14 11/20/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0347 1391 Plant: Ticket No.: 259 25960678 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 5.1 3-6 76 61 142.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/22/14 0445 Vincent Green 50/580 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/29/14 7 46,560 5 3,710 1 2 4.00 12.57 11/19/14 28 53,650 1 4,270 1 3 4.00 12.57 11/19/14 28 51,190 4 4,070 1 4 4.00 12.57 11/19/14 28 53,990 4 4,300 Average (28 days) 4,210 1 5 4.00 12.57 12/17/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0307 10/22/14 11/20/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0501 1375 Plant: Ticket No.: 259 25960762 Field Test Data Test Air Content (%): Result Specification 5 3-5 4.4 3-6 74 59 148.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/22/14 0615 Vincent Green 140/580 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 10/29/14 7 42,790 5 3,410 2 2 4.00 12.57 11/19/14 28 52,930 5 4,210 2 3 4.00 12.57 11/19/14 28 57,020 5 4,540 2 4 4.00 12.57 11/19/14 28 53,300 5 4,240 Average (28 days) 4,330 2 5 4.00 12.57 12/17/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0307 10/22/14 11/20/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0631 1375 Plant: Ticket No.: 259 25960881 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 4.6 3-6 75 62 149.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/22/14 0750 Vincent Green 240/580 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 10/29/14 7 46,870 4 3,730 3 2 4.00 12.57 11/19/14 28 52,200 5 4,150 3 3 4.00 12.57 11/19/14 28 56,670 4 4,510 3 4 4.00 12.57 11/19/14 28 61,000 4 4,850 Average (28 days) 4,500 3 5 4.00 12.57 12/17/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0307 10/22/14 11/20/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0818 1191 Plant: Ticket No.: 259 25961035 Field Test Data Test Air Content (%): Result Specification 5 3-5 4.5 3-6 78 66 146.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/22/14 0901 Vincent Green 350/580 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 10/29/14 7 41,470 6 3,300 4 2 4.00 12.57 11/19/14 28 52,940 1 4,210 4 3 4.00 12.57 11/19/14 28 51,140 5 4,070 4 4 4.00 12.57 11/19/14 28 49,910 4 3,970 Average (28 days) 4,080 4 5 4.00 12.57 12/17/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0307 10/22/14 11/20/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0946 1287 Plant: Ticket No.: 259 25961185 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.5 3-6 77 65 145.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/22/14 1040 Vincent Green 440/580 10 5 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 10/29/14 7 41,410 4 3,300 5 2 4.00 12.57 11/19/14 28 51,770 4 4,120 5 3 4.00 12.57 11/19/14 28 59,150 5 4,710 5 4 4.00 12.57 11/19/14 28 58,080 5 4,620 Average (28 days) 4,480 5 5 4.00 12.57 12/17/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0307 10/22/14 11/20/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 1147 1433 Plant: Ticket No.: 259 25961417 Field Test Data Test Air Content (%): Result Specification 4 3-5 4.7 3-6 80 74 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/22/14 1236 Vincent Green 550/580 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 6 1 4.00 12.57 10/29/14 7 45,160 4 3,590 6 2 4.00 12.57 11/19/14 28 53,670 4 4,270 6 3 4.00 12.57 11/19/14 28 53,460 5 4,250 6 4 4.00 12.57 11/19/14 28 51,220 4 4,080 Average (28 days) 4,200 6 5 4.00 12.57 12/17/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0307 10/22/14 12/18/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0347 1391 Plant: Ticket No.: 259 25960678 Field Test Data Test Air Content (%): Result Specification 4 3/4 3-5 5.1 3-6 76 61 142.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/22/14 0445 Vincent Green 50/580 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/29/14 7 46,560 5 3,710 1 2 4.00 12.57 11/19/14 28 53,650 1 4,270 1 3 4.00 12.57 11/19/14 28 51,190 4 4,070 1 4 4.00 12.57 11/19/14 28 53,990 4 4,300 Average (28 days) 4,210 1 5 4.00 12.57 12/17/14 56 57,040 4 4,540 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0307 10/22/14 12/18/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0501 1375 Plant: Ticket No.: 259 25960762 Field Test Data Test Air Content (%): Result Specification 5 3-5 4.4 3-6 74 59 148.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/22/14 0615 Vincent Green 140/580 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 10/29/14 7 42,790 5 3,410 2 2 4.00 12.57 11/19/14 28 52,930 5 4,210 2 3 4.00 12.57 11/19/14 28 57,020 5 4,540 2 4 4.00 12.57 11/19/14 28 53,300 5 4,240 Average (28 days) 4,330 2 5 4.00 12.57 12/17/14 56 62,720 2 4,990 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0307 10/22/14 12/18/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0631 1375 Plant: Ticket No.: 259 25960881 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 4.6 3-6 75 62 149.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/22/14 0750 Vincent Green 240/580 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 10/29/14 7 46,870 4 3,730 3 2 4.00 12.57 11/19/14 28 52,200 5 4,150 3 3 4.00 12.57 11/19/14 28 56,670 4 4,510 3 4 4.00 12.57 11/19/14 28 61,000 4 4,850 Average (28 days) 4,500 3 5 4.00 12.57 12/17/14 56 62,210 4 4,950 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0307 10/22/14 12/18/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0818 1191 Plant: Ticket No.: 259 25961035 Field Test Data Test Air Content (%): Result Specification 5 3-5 4.5 3-6 78 66 146.8 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/22/14 0901 Vincent Green 350/580 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 10/29/14 7 41,470 6 3,300 4 2 4.00 12.57 11/19/14 28 52,940 1 4,210 4 3 4.00 12.57 11/19/14 28 51,140 5 4,070 4 4 4.00 12.57 11/19/14 28 49,910 4 3,970 Average (28 days) 4,080 4 5 4.00 12.57 12/17/14 56 59,530 3 4,740 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0307 10/22/14 12/18/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0946 1287 Plant: Ticket No.: 259 25961185 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.5 3-6 77 65 145.6 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/22/14 1040 Vincent Green 440/580 10 5 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 5 1 4.00 12.57 10/29/14 7 41,410 4 3,300 5 2 4.00 12.57 11/19/14 28 51,770 4 4,120 5 3 4.00 12.57 11/19/14 28 59,150 5 4,710 5 4 4.00 12.57 11/19/14 28 58,080 5 4,620 Average (28 days) 4,480 5 5 4.00 12.57 12/17/14 56 59,920 3 4,770 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 6CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0307 10/22/14 12/18/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 1147 1433 Plant: Ticket No.: 259 25961417 Field Test Data Test Air Content (%): Result Specification 4 3-5 4.7 3-6 80 74 146.4 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/22/14 1236 Vincent Green 550/580 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Pavement, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 6 1 4.00 12.57 10/29/14 7 45,160 4 3,590 6 2 4.00 12.57 11/19/14 28 53,670 4 4,270 6 3 4.00 12.57 11/19/14 28 53,460 5 4,250 6 4 4.00 12.57 11/19/14 28 51,220 4 4,080 Average (28 days) 4,200 6 5 4.00 12.57 12/17/14 56 57,180 5 4,550 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Vincent Green The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 6 of 6CR0001, 11-16-12, Rev.6 STRUCTURAL STEEL OBSERVATIONS REPORT Report Number:94141126.0309 Service Date:10/22/14 8901 Carpenter Frwy., Suite 100 Report Date:10/23/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Structural steel observations. Terracon Rep.: Randy T. Walcker, C.W.I. Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 sbv On this date, Terracon's representative arrived at the above referenced job site as scheduled for structural steel observations. A visual observation was performed as noted below. A.Building B, Roof Level, Framing @ A-H/1-4: 1.Column anchor bolts were determined to be compliant. 2.Joist and girder seat welds were determined to be compliant. 3.Joist bridging was determined to be compliant. 4.Joist seat support lug weldments at the tilt wall panel embed plates were determined to be compliant. NOTE:South wall leave out panel bay, structural steel items not erected at this time. *Noted discrepancies and/or incomplete work. FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0310 10/22/14 10/23/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4195.324.294141126.0001 Dark brown clay with trace sand ASTM D698 92-98>/= +4296.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 95-2/+2386.830.294141126.0036 Lime treated dark and light brown clay ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Building D, SW corner, Interior Panel Leaveouts 2141 1' N & 10' E 1' BFG 2 6 117.9 25.5 27.6 92.4 96 2142 1' N & 70' E 1' BFG 2 6 117.9 25.9 28.1 92.0 96 2143 1' N & 110' E 1' BFG 2 6 118.0 25.3 27.3 92.7 96 2144 40' N & 1' E Final 3 6 110.2 25.8 30.6 84.4 97 Comments: Datum:BFG = Below final grade Serial No:21426 Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Paul Butler ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 1 REINFORCING STEEL OBSERVATIONS REPORT Report Number:94141126.0312 Service Date:10/23/14 8901 Carpenter Frwy., Suite 100 Report Date:10/28/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Reinforcing steel (rebar) placement observation. Terracon Rep.: Tyrece Lewis Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940003, 07-01-12, Rev.0 Page 1 of 1 sbv PROJECT DATA Drawings Utilized:Sheets/DetailsC6.01/Paving Details, dated 04-23-2014 Locations/Items Observed:Building D, Slab Leaveouts, see attached sketch Test Method:Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT Placing Drawings Approved X Bar Length and Shape X Column Tie Spacing & Type Bar Size X Proper Bar Placement X Stirrup Spacing & Type Bar Grade X Properly Tied X Welded Splices Rebar Clean X Dowel Bars in Place X Mechanical Splices Trash & Debris Removed X Proper Bar Supports X Lapped Splices X Number of Bars X Proper Cover/Clearance X Discrepancies/Comments: No discrepancies were noted at the time of this observation. Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0313 10/23/14 11/04/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0644 1377 Plant: Ticket No.: P259 25961981 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.9 0-3 78 64 151.9 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/23/14 0736 Tyrece Lewis N/A (Inside) 30/200 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab Leaveouts, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/30/14 7 61,910 5 4,930 1 2 4.00 12.57 11/20/14 28 1 3 4.00 12.57 11/20/14 28 1 4 4.00 12.57 11/20/14 28 1 5 4.00 12.57 12/18/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Tyrece Lewis The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0313 10/23/14 11/04/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0837 1393 Plant: Ticket No.: P259 25962135 Field Test Data Test Air Content (%): Result Specification 4 3-5 2.1 0-3 79 65 148.7 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/23/14 0925 Tyrece Lewis N/A (inside) 100/200 10 10 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab Leaveouts, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 10/30/14 7 60,890 4 4,850 2 2 4.00 12.57 11/20/14 28 2 3 4.00 12.57 11/20/14 28 2 4 4.00 12.57 11/20/14 28 2 5 4.00 12.57 12/18/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Tyrece Lewis The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0313 10/23/14 11/21/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0644 1377 Plant: Ticket No.: P259 25961981 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.9 0-3 78 64 151.9 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/23/14 0736 Tyrece Lewis N/A (Inside) 30/200 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab Leaveouts, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/30/14 7 61,910 5 4,930 1 2 4.00 12.57 11/20/14 28 73,210 4 5,830 1 3 4.00 12.57 11/20/14 28 75,880 2 6,040 1 4 4.00 12.57 11/20/14 28 75,720 5 6,030 Average (28 days) 5,970 1 5 4.00 12.57 12/18/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Tyrece Lewis The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0313 10/23/14 11/21/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0837 1393 Plant: Ticket No.: P259 25962135 Field Test Data Test Air Content (%): Result Specification 4 3-5 2.1 0-3 79 65 148.7 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/23/14 0925 Tyrece Lewis N/A (inside) 100/200 10 10 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab Leaveouts, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 10/30/14 7 60,890 4 4,850 2 2 4.00 12.57 11/20/14 28 72,570 2 5,780 2 3 4.00 12.57 11/20/14 28 73,670 5 5,860 2 4 4.00 12.57 11/20/14 28 75,280 4 5,990 Average (28 days) 5,880 2 5 4.00 12.57 12/18/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Tyrece Lewis The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0313 10/23/14 12/19/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0644 1377 Plant: Ticket No.: P259 25961981 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.9 0-3 78 64 151.9 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/23/14 0736 Tyrece Lewis N/A (Inside) 30/200 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab Leaveouts, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/30/14 7 61,910 5 4,930 1 2 4.00 12.57 11/20/14 28 73,210 4 5,830 1 3 4.00 12.57 11/20/14 28 75,880 2 6,040 1 4 4.00 12.57 11/20/14 28 75,720 5 6,030 Average (28 days) 5,970 1 5 4.00 12.57 12/18/14 56 82,620 2 6,580 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Tyrece Lewis The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0313 10/23/14 12/19/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0837 1393 Plant: Ticket No.: P259 25962135 Field Test Data Test Air Content (%): Result Specification 4 3-5 2.1 0-3 79 65 148.7 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/23/14 0925 Tyrece Lewis N/A (inside) 100/200 10 10 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab Leaveouts, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 10/30/14 7 60,890 4 4,850 2 2 4.00 12.57 11/20/14 28 72,570 2 5,780 2 3 4.00 12.57 11/20/14 28 73,670 5 5,860 2 4 4.00 12.57 11/20/14 28 75,280 4 5,990 Average (28 days) 5,880 2 5 4.00 12.57 12/18/14 56 83,560 3 6,650 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Tyrece Lewis The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0315 10/23/14 11/04/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0851 1183 Plant: Ticket No.: 236 25962141 Field Test Data Test Air Content (%): Result Specification 5 3-5 3.2 3-6 80 65 150.3 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/23/14 0948 Tyrece Lewis Partly cloudy, light rain 40/100 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Freeport Parkway Turn Lane, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/30/14 7 52,790 4 4,200 1 2 4.00 12.57 11/20/14 28 1 3 4.00 12.57 11/20/14 28 1 4 4.00 12.57 11/20/14 28 1 5 4.00 12.57 12/18/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Tyrece Lewis The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0315 10/23/14 11/21/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0851 1183 Plant: Ticket No.: 236 25962141 Field Test Data Test Air Content (%): Result Specification 5 3-5 3.2 3-6 80 65 150.3 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/23/14 0948 Tyrece Lewis Partly cloudy, light rain 40/100 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Freeport Parkway Turn Lane, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/30/14 7 52,790 4 4,200 1 2 4.00 12.57 11/20/14 28 66,800 5 5,320 1 3 4.00 12.57 11/20/14 28 66,790 4 5,320 1 4 4.00 12.57 11/20/14 28 66,260 4 5,270 Average (28 days) 5,300 1 5 4.00 12.57 12/18/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Tyrece Lewis The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0315 10/23/14 12/19/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0851 1183 Plant: Ticket No.: 236 25962141 Field Test Data Test Air Content (%): Result Specification 5 3-5 3.2 3-6 80 65 150.3 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/23/14 0948 Tyrece Lewis Partly cloudy, light rain 40/100 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Freeport Parkway Turn Lane, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 10/30/14 7 52,790 4 4,200 1 2 4.00 12.57 11/20/14 28 66,800 5 5,320 1 3 4.00 12.57 11/20/14 28 66,790 4 5,320 1 4 4.00 12.57 11/20/14 28 66,260 4 5,270 Average (28 days) 5,300 1 5 4.00 12.57 12/18/14 56 71,400 2 5,680 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Tyrece Lewis The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0316 10/23/14 10/28/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Building D, East Wall, Leaveout Slab Area 2145 Approximately 150' N of S corner 3' BFG 1 6 117.7 26.0 28.3 91.7 95 2146 Approximately 220' N of S corner 2' BFG 1 6 118.2 25.3 27.2 92.9 97 2147 Approximately 300' N of S corner 1' BFG 1 6 116.4 25.1 27.5 91.3 95 2148 Approximately 150' N of S corner 1' BFG 1 6 116.5 24.7 26.9 91.8 95* Comments: Datum: BFG - Below final grade Serial No:24412 Test and/or retest results on this report meet project requirements as noted above. Recommend Passing Test # 2148 above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor:Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Daniel Jordan ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 1 STRUCTURAL STEEL OBSERVATIONS REPORT Report Number:94141126.0321 Service Date:10/24/14 8901 Carpenter Frwy., Suite 100 Report Date:10/29/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Structural steel observations. Terracon Rep.: Oscar R. Esparza, Jr., CWI 00020341 Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 dgr On this date, Terracon's representative arrived at the above referenced job site as scheduled for structural steel observations. A visual observation was performed as noted below. A.Building C, Roof Level Framing: 1.Perimeter metal deck support angle top side welds to the tilt wall panel embed plates were determined to be compliant. 2.Metal deck installation puddle welds and side lap screws were determined to be compliant. GRADATION REPORT Report Number:94141126.0322 Service Date:10/24/14 8901 Carpenter Frwy., Suite 100 Report Date:10/30/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Perform gradation tests on lime stabilized soil. Terracon Rep.: Armando Rendon Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940006, 05-23-14, Rev.3 Page 1 of 1 dgr SERVICES:SPECIFICATION REQUIREMENTS: Minimum Passing 1 3/4” Sieve (%):100 Performed gradation tests on lime treated soil. Minimum Passing #4 Sieve (%): 60 TEST METHOD:TEX 101-E, Part III Sample Condition: Field Moist TEST LOCATION:South of Bldg. C TEST NO.LOCATION 1 3/4” SIEVE % PASSING #4 SIEVE % PASSING 1 30’ S & 10’ W of SW corner 100 64 2 30’ S & 50’ E of SW corner 100 65 3 10’ N & 30’ E of SE corner 100 65 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0323 10/25/14 10/30/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 95-1/+3186.830.294141126.0036 Lime treated dark and light brown clay ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) SW corner of Building C, Pavement 2149 30' S & 10' W Final 1 6 113.6 27.7 32.3 85.9 99 2150 30' S & 50' E Final 1 6 115.8 28.5 32.6 87.3 100+ SE corner of Building C, Pavement 2151 10' N & 30' E Final 1 6 114.4 27.7 31.9 86.7 100 Comments: Datum:Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 1 REINFORCING STEEL OBSERVATIONS REPORT Report Number:94141126.0324 Service Date:10/27/14 8901 Carpenter Frwy., Suite 100 Report Date:11/03/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Reinforcing steel (rebar) placement observation. Terracon Rep.: Tyrece Lewis Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940003, 07-01-12, Rev.0 Page 1 of 1 sbv PROJECT DATA Drawings Utilized:Structural Sheets/Details: C6.01/Pavement Details, dated 04-23-2014 Locations/Items Observed:Sidewalks at turn lane on Freeport Parkway; Building D, Slab Leavouts, see attached sketch Test Method:Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT Placing Drawings Approved X Bar Length and Shape X Column Tie Spacing & Type Bar Size X Proper Bar Placement X Stirrup Spacing & Type Bar Grade X Properly Tied X Welded Splices Rebar Clean X Dowel Bars in Place X Mechanical Splices Trash & Debris Removed X Proper Bar Supports X Lapped Splices X Number of Bars X Proper Cover/Clearance X Discrepancies/Comments: No discrepancies were noted at the time of this observation. Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0325 10/27/14 11/10/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0716 1192 Plant: Ticket No.: 136 25964057 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.9 0-3 80 81 151.9 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/27/14 0817 Tyrece Lewis 40/100 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab Leaveouts, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 11/03/14 7 58,930 4 4,690 1 2 4.00 12.57 11/24/14 28 1 3 4.00 12.57 11/24/14 28 1 4 4.00 12.57 11/24/14 28 1 5 4.00 12.57 12/22/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Tyrece Lewis The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 '"~TERRACON REPORT NO. j ,"I,:,q~'~Hill O~ZS ------'1.7 j-~t-'-'=_____~__~0 -Z.7 -/".)i \ ::"'=,.:-.-'s----- , ~i· 1+1-· I .J I ,H--~, ~ , I I "1.r r 0 ~'" ,i I~,,-z,'-\!/P., -,,- 'O- r=:- ~BLDG.A BLDG.D • o 3~GO 90 "20 I ,- -"c- ~LEGEND E:ill ~,~~~I(=~';8~C2~~ WITH 6"LIME STA8~<ZAno~ ,-----,6'TllICI';HIOO FSI CO"lC't.HIOL--.J VI1TH~3SARSON'8"O,CE-W Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0325 10/27/14 11/24/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0716 1192 Plant: Ticket No.: 136 25964057 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.9 0-3 80 81 151.9 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/27/14 0817 Tyrece Lewis 40/100 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab Leaveouts, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 11/03/14 7 58,930 4 4,690 1 2 4.00 12.57 11/24/14 28 67,680 2 5,390 1 3 4.00 12.57 11/24/14 28 72,800 2 5,790 1 4 4.00 12.57 11/24/14 28 69,170 2 5,500 Average (28 days) 5,560 1 5 4.00 12.57 12/22/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Tyrece Lewis The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 '"~TERRACON REPORT NO. j ,"I,:,q~'~Hill O~ZS ------'1.7 j-~t-'-'=_____~__~0 -Z.7 -/".)i \ ::"'=,.:-.-'s----- , ~i· 1+1-· I .J I ,H--~, ~ , I I "1.r r 0 ~'" ,i I~,,-z,'-\!/P., -,,- 'O- r=:- ~BLDG.A BLDG.D • o 3~GO 90 "20 I ,- -"c- ~LEGEND E:ill ~,~~~I(=~';8~C2~~ WITH 6"LIME STA8~<ZAno~ ,-----,6'TllICI';HIOO FSI CO"lC't.HIOL--.J VI1TH~3SARSON'8"O,CE-W Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0325 10/27/14 12/23/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 140P25P1 Redi-Mix Material Information 0716 1192 Plant: Ticket No.: 136 25964057 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 1.9 0-3 80 81 151.9 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/27/14 0817 Tyrece Lewis 40/100 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Building D, Slab Leaveouts, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 11/03/14 7 58,930 4 4,690 1 2 4.00 12.57 11/24/14 28 67,680 2 5,390 1 3 4.00 12.57 11/24/14 28 72,800 2 5,790 1 4 4.00 12.57 11/24/14 28 69,170 2 5,500 Average (28 days) 5,560 1 5 4.00 12.57 12/22/14 56 74,500 2 5,930 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Tyrece Lewis The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 '"~TERRACON REPORT NO. j ,"I,:,q~'~Hill O~ZS ------'1.7 j-~t-'-'=_____~__~0 -Z.7 -/".)i \ ::"'=,.:-.-'s----- , ~i· 1+1-· I .J I ,H--~, ~ , I I "1.r r 0 ~'" ,i I~,,-z,'-\!/P., -,,- 'O- r=:- ~BLDG.A BLDG.D • o 3~GO 90 "20 I ,- -"c- ~LEGEND E:ill ~,~~~I(=~';8~C2~~ WITH 6"LIME STA8~<ZAno~ ,-----,6'TllICI';HIOO FSI CO"lC't.HIOL--.J VI1TH~3SARSON'8"O,CE-W FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0326 10/27/14 11/03/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 92-98>/= +4195.324.294141126.0001 Dark brown clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Building C, Interior Panel Backfill 2158 10' N & 1' W of SE corner 2' BFG 1 6 114.8 25.6 28.7 89.2 94 2159 110' N & 1' W of SE corner 2' BFG 1 6 115.2 25.6 28.6 89.6 94 2160 200' N & 1' W of SE corner 2' BFG 1 6 114.1 25.7 29.1 88.4 93 2161 280' N & 1' W of SE corner 2' BFG 1 6 115.0 25.5 28.5 89.5 94 2162 360' N & 1' W of SE corner 2' BFG 1 6 114.9 26.1 29.4 88.8 93 2163 370' N & 1' W of SE corner 1' BFG 1 6 114.9 26.3 29.7 88.6 93 2164 440' N & 1' W of SE corner 1' BFG 1 6 115.0 25.8 28.9 89.2 94 Comments: Datum: BFG - Below final grade Serial No:21426 Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Paul Butler ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 1 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0327 10/27/14 11/10/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 1346 1396 Plant: Ticket No.: 136 25964023 Field Test Data Test Air Content (%): Result Specification 5 3-5 3.9 3-6 81 82 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/27/14 1440 Tyrece Lewis Partly cloudy 10/10 10 20 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Sidewalks, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 11/03/14 7 52,760 5 4,200 1 2 4.00 12.57 11/24/14 28 1 3 4.00 12.57 11/24/14 28 1 4 4.00 12.57 11/24/14 28 1 5 4.00 12.57 12/22/14 56 Comments:Not tested for plastic unit weight. NOTE: Red clay added to cement mixture. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Tyrece Lewis The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0327 10/27/14 11/24/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 1346 1396 Plant: Ticket No.: 136 25964023 Field Test Data Test Air Content (%): Result Specification 5 3-5 3.9 3-6 81 82 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/27/14 1440 Tyrece Lewis Partly cloudy 10/10 10 20 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Sidewalks, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 11/03/14 7 52,760 5 4,200 1 2 4.00 12.57 11/24/14 28 58,880 5 4,690 1 3 4.00 12.57 11/24/14 28 55,740 3 4,440 1 4 4.00 12.57 11/24/14 28 57,290 5 4,560 Average (28 days) 4,560 1 5 4.00 12.57 12/22/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Not tested for plastic unit weight. NOTE: Red clay added to cement mixture. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Tyrece Lewis The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0327 10/27/14 12/23/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 1346 1396 Plant: Ticket No.: 136 25964023 Field Test Data Test Air Content (%): Result Specification 5 3-5 3.9 3-6 81 82 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/27/14 1440 Tyrece Lewis Partly cloudy 10/10 10 20 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Sidewalks, see attached sketchPlacement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 11/03/14 7 52,760 5 4,200 1 2 4.00 12.57 11/24/14 28 58,880 5 4,690 1 3 4.00 12.57 11/24/14 28 55,740 3 4,440 1 4 4.00 12.57 11/24/14 28 57,290 5 4,560 Average (28 days) 4,560 1 5 4.00 12.57 12/22/14 56 61,850 2 4,920 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Not tested for plastic unit weight. NOTE: Red clay added to cement mixture. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Tyrece Lewis The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6 FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94141126.0328 10/24/14 10/30/14 8901 Carpenter Frwy., Suite 100 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 Park West Crossing 910, 920 & 930 Freeport Pkwy & 631 Southwestern Blvd Coppell, TX Project Number:94141126 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 95-1/+3196.223.094141126.0002 Brown, tan and gray clay with trace sand ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Paving 2152 30' S & 20' E of NE corner of bldg. A Final 1 6 120.5 22.7 23.2 97.8 100+ 2153 110' S & 20' E of NE corner of bldg. A Final 1 6 118.7 22.2 23.0 96.5 100 2154 30' S & 20' E of NE corner of bldg. B Final 1 6 118.8 22.8 23.8 96.0 100 2155 120' S & 20' E of NE corner of bldg. B Final 1 6 118.9 23.2 24.2 95.7 99 2156 30' S & 20' E of NE corner of bldg. C Final 1 6 118.6 22.7 23.7 95.9 100 2157 150' S & 20' E of NE corner of bldg. C Final 1 6 119.5 22.7 23.5 96.8 100+ Comments: Datum:Serial No: Test and/or retest results on this report meet project requirements as noted above. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Structure Tone Southwest James D. Baze Project Manager Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Reviewed By: Terracon Rep.: Armando Rendon ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 1 REINFORCING STEEL OBSERVATIONS REPORT Report Number:94141126.0329 Service Date:10/28/14 8901 Carpenter Frwy., Suite 100 Report Date:11/04/14 Dallas, TX 75247 214-630-1010 Reg No: F-3272 Client Project ML Realty Partners Park West Crossing Attn: Timothy Geisler 910, 920 & 930 Freeport Pkwy One Pierce Pl Ste 450W & 631 Southwestern Blvd Itasca, IL 60143 Coppell, TX Project Number: 94141126 Services: Reinforcing steel (rebar) placement observation. Terracon Rep.: Jose Delgado Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole(1) Structure Tone Southwest Inc., Robin Povey Reviewed By:____________________________________ James D. Baze Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. R940003, 07-01-12, Rev.0 Page 1 of 1 sbv PROJECT DATA Drawings Utilized:Sheets/Details: C6.01 Locations/Items Observed:Building C, West side, Pavement Test Method:Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT Placing Drawings Approved X Bar Length and Shape X Column Tie Spacing & Type X Bar Size X Proper Bar Placement X Stirrup Spacing & Type X Bar Grade X Properly Tied X Welded Splices Rebar Clean X Dowel Bars in Place X Mechanical Splices Trash & Debris Removed X Proper Bar Supports X Lapped Splices X Number of Bars X Proper Cover/Clearance X Discrepancies/Comments: No discrepancies were noted at the time of this observation. Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0330 10/28/14 11/10/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0307 1182 Plant: Ticket No.: 136 25964854 Field Test Data Test Air Content (%): Result Specification 5 3/4 3-5 6.2 3-6 79 71 144.7 * * * = Field Test Results do not meet project specifications. 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/28/14 0340 Jose Delgado Cloudy 60/350 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Paving at west side of Building C, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 11/04/14 7 55,800 2 4,440 1 2 4.00 12.57 11/25/14 28 1 3 4.00 12.57 11/25/14 28 1 4 4.00 12.57 11/25/14 28 1 5 4.00 12.57 12/23/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jose Delgado The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0330 10/28/14 11/10/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0407 1430 Plant: Ticket No.: 136 25964890 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.8 3-6 80 73 146.3 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/28/14 0446 Jose Delgado Cloudy 150/350 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Paving at west side of Building C, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 11/04/14 7 63,770 3 5,080 2 2 4.00 12.57 11/25/14 28 2 3 4.00 12.57 11/25/14 28 2 4 4.00 12.57 11/25/14 28 2 5 4.00 12.57 12/23/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jose Delgado The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0330 10/28/14 11/10/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0533 1445 Plant: Ticket No.: 136 25964947 Field Test Data Test Air Content (%): Result Specification 4 3-5 5.8 3-6 80 75 145.5 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/28/14 0608 Jose Delgado Cloudy 240/350 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Paving at west side of Building C, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 11/04/14 7 64,080 6 5,100 3 2 4.00 12.57 11/25/14 28 3 3 4.00 12.57 11/25/14 28 3 4 4.00 12.57 11/25/14 28 3 5 4.00 12.57 12/23/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jose Delgado The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0330 10/28/14 11/10/14 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0714 1183 Plant: Ticket No.: 136 25965037 Field Test Data Test Air Content (%): Result Specification 5 3/4 3-5 5.5 3-6 79 69 149.5 * * = Field Test Results do not meet project specifications. 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/28/14 0749 Jose Delgado Partly cloudy 320/350 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Paving at west side of Building C, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 11/04/14 7 58,610 2 4,660 4 2 4.00 12.57 11/25/14 28 4 3 4.00 12.57 11/25/14 28 4 4 4.00 12.57 11/25/14 28 4 5 4.00 12.57 12/23/14 56 Comments: Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jose Delgado The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 4CR0001, 11-16-12, Rev.6 ·~<>.3!--I-.s::}\J -r-.-\-'-l~-<:<:!:)-'"'.0 ----.. " Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0330 10/28/14 11/25/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0307 1182 Plant: Ticket No.: 136 25964854 Field Test Data Test Air Content (%): Result Specification 5 3/4 3-5 6.2 3-6 79 71 144.7 * * * = Field Test Results do not meet project specifications. 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/28/14 0340 Jose Delgado Cloudy 60/350 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Paving at west side of Building C, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 11/04/14 7 55,800 2 4,440 1 2 4.00 12.57 11/25/14 28 64,970 4 5,170 1 3 4.00 12.57 11/25/14 28 65,980 4 5,250 1 4 4.00 12.57 11/25/14 28 65,620 4 5,220 Average (28 days) 5,210 1 5 4.00 12.57 12/23/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jose Delgado The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0330 10/28/14 11/25/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0407 1430 Plant: Ticket No.: 136 25964890 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.8 3-6 80 73 146.3 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/28/14 0446 Jose Delgado Cloudy 150/350 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Paving at west side of Building C, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 11/04/14 7 63,770 3 5,080 2 2 4.00 12.57 11/25/14 28 77,300 1 6,150 2 3 4.00 12.57 11/25/14 28 76,320 4 6,070 2 4 4.00 12.57 11/25/14 28 78,660 4 6,260 Average (28 days) 6,160 2 5 4.00 12.57 12/23/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jose Delgado The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0330 10/28/14 11/25/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0533 1445 Plant: Ticket No.: 136 25964947 Field Test Data Test Air Content (%): Result Specification 4 3-5 5.8 3-6 80 75 145.5 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/28/14 0608 Jose Delgado Cloudy 240/350 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Paving at west side of Building C, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 11/04/14 7 64,080 6 5,100 3 2 4.00 12.57 11/25/14 28 72,820 1 5,800 3 3 4.00 12.57 11/25/14 28 74,430 1 5,920 3 4 4.00 12.57 11/25/14 28 74,930 4 5,960 Average (28 days) 5,890 3 5 4.00 12.57 12/23/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jose Delgado The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0330 10/28/14 11/25/14 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0714 1183 Plant: Ticket No.: 136 25965037 Field Test Data Test Air Content (%): Result Specification 5 3/4 3-5 5.5 3-6 79 69 149.5 * * = Field Test Results do not meet project specifications. 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/28/14 0749 Jose Delgado Partly cloudy 320/350 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Paving at west side of Building C, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 11/04/14 7 58,610 2 4,660 4 2 4.00 12.57 11/25/14 28 65,200 4 5,190 4 3 4.00 12.57 11/25/14 28 67,490 4 5,370 4 4 4.00 12.57 11/25/14 28 70,010 4 5,570 Average (28 days) 5,380 4 5 4.00 12.57 12/23/14 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jose Delgado The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 4CR0001, 11-16-12, Rev.6 ·~<>.3!--I-.s::}\J -r-.-\-'-l~-<:<:!:)-'"'.0 ----.. " Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0330 10/28/14 12/24/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0307 1182 Plant: Ticket No.: 136 25964854 Field Test Data Test Air Content (%): Result Specification 5 3/4 3-5 6.2 3-6 79 71 144.7 * * * = Field Test Results do not meet project specifications. 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/28/14 0340 Jose Delgado Cloudy 60/350 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Paving at west side of Building C, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 11/04/14 7 55,800 2 4,440 1 2 4.00 12.57 11/25/14 28 64,970 4 5,170 1 3 4.00 12.57 11/25/14 28 65,980 4 5,250 1 4 4.00 12.57 11/25/14 28 65,620 4 5,220 Average (28 days) 5,210 1 5 4.00 12.57 12/23/14 56 71,250 4 5,670 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jose Delgado The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0330 10/28/14 12/24/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0407 1430 Plant: Ticket No.: 136 25964890 Field Test Data Test Air Content (%): Result Specification 5 3-5 5.8 3-6 80 73 146.3 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/28/14 0446 Jose Delgado Cloudy 150/350 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Paving at west side of Building C, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 2 1 4.00 12.57 11/04/14 7 63,770 3 5,080 2 2 4.00 12.57 11/25/14 28 77,300 1 6,150 2 3 4.00 12.57 11/25/14 28 76,320 4 6,070 2 4 4.00 12.57 11/25/14 28 78,660 4 6,260 Average (28 days) 6,160 2 5 4.00 12.57 12/23/14 56 87,200 4 6,940 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jose Delgado The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0330 10/28/14 12/24/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0533 1445 Plant: Ticket No.: 136 25964947 Field Test Data Test Air Content (%): Result Specification 4 3-5 5.8 3-6 80 75 145.5 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/28/14 0608 Jose Delgado Cloudy 240/350 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Paving at west side of Building C, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 3 1 4.00 12.57 11/04/14 7 64,080 6 5,100 3 2 4.00 12.57 11/25/14 28 72,820 1 5,800 3 3 4.00 12.57 11/25/14 28 74,430 1 5,920 3 4 4.00 12.57 11/25/14 28 74,930 4 5,960 Average (28 days) 5,890 3 5 4.00 12.57 12/23/14 56 79,690 4 6,340 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey Structure Tone Southwest ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jose Delgado The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 4CR0001, 11-16-12, Rev.6 Report Number: Service Date: Report Date: Task: Client Project Project Number:94141126 Coppell, TX & 631 Southwestern Blvd 910, 920 & 930 Freeport Pkwy Park West CrossingML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247 8901 Carpenter Frwy., Suite 100 94141126.0330 10/28/14 12/24/14 Revision 2 - 56-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10L11504 Redi-Mix Material Information 0714 1183 Plant: Ticket No.: 136 25965037 Field Test Data Test Air Content (%): Result Specification 5 3/4 3-5 5.5 3-6 79 69 149.5 * * = Field Test Results do not meet project specifications. 4,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:10/28/14 0749 Jose Delgado Partly cloudy 320/350 10 0 0 See Placement LocationSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Paving at west side of Building C, see attached sketch Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 4 1 4.00 12.57 11/04/14 7 58,610 2 4,660 4 2 4.00 12.57 11/25/14 28 65,200 4 5,190 4 3 4.00 12.57 11/25/14 28 67,490 4 5,370 4 4 4.00 12.57 11/25/14 28 70,010 4 5,570 Average (28 days) 5,380 4 5 4.00 12.57 12/23/14 56 73,500 4 5,850 Comments:Compressive strength of 56 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) Structure Tone Southwest Inc., Mike Toole (1) Structure Tone Southwest Inc., Robin Povey James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Jose Delgado The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 4CR0001, 11-16-12, Rev.6