REPORT OF CONCRETE MIX, OBSERVATION
Report Date: January 21, 2015 Date Concrete Placed: Jul 21 1014 Standard 6"-12" r' 1; A
Client:
City of Coppell
y n ers
Project:
Freeport Pkwy from Ruby Rd. to Sandy
Cylinder
Lake Rd.
Cross-sectional Area: 28.27 Square Inches
Contractor:
CD Builders Inc.
7
Concrete Report No.: 13
Concrete Supplier and Plant:
Argos #110
Project No.: 214-0144
Location of Placement:
Piers2-C
8/20/14
135,700+
4,800-+
FPP 51
MATERIALS
Source / SSD Batch Wts.
Description (Lbs/CuYd)
OBSERVATION DATA
4,810+-
Mix Number:
1083
Time Sample Batched:
3:30PM
Cement:
Time Sampled
4.30PM
Fly Ash:
Fracture Regular
Sample Location:
Piers2-C
Coarse Aggregate:
Cylinders Made By: CP
Truck / Ticket No:
2013/ 1457572
Intermediate Aggregate:
Temperature:
Fine Aggregate:
Ambient Range:
96 OF
Admixtures:
Concrete Range:
99 OF
I
Slump Range (inches):
3.0
2
Weather Conditions:
Cloudy
Tim e Started:
7:00 AM
Added Water:
Time Completed:
6:00 PM
Sample Air Content
4
Total Cubic Yards Placed:
10
Specimen
Number
Measured
Slump in.
Age
(Days)
Date
T ested
Total Load
(Lbs.)
Compressive Strength
(Lbs./Sq.1n.)
Remarks
FPP 49
7
7/30/14
128,140
4,390
FPP 50
10
28
8/20/14
135,700+
4,800-+
FPP 51
28
8/20/14
136000+
4,810+-
FPP 52
H
Hold
Test Methods Utilized
Fracture Regular
ASTM C-31, C-391 C-143
(Unless Noted Otherwise) I
Cylinders Made By: CP
lKernarks and/or Distribution:- None
cc: Rick Odell <ROdellnqcoppeIltK.gov>
Mr. Michael Garza - City of Coppell, Phone: 972-304-3679-, via E-mail: MGarza(Ki),coppelltx.gov
Mr. Mitch I lolmes - Teague, Nall & Perkins, Phone: 432-312-4205; via E-mail: mhoImes@tnpinc.com
Mr. Francisco Luyando - CD Builders, Inc., Phone: 787-688-8207; via E-mail: fluyandogcdbuilderspr.corn
GEE Consultants, Inc. TBPE Firm: F-3212 Reviewed by:
All letteis and reports are for the excursive uske nse of the client to whom they we addressed and shall not be reproduced without the full approval of GEE Consultants,Jnc, file use of our name mustleceive our prior written approval. Out letters and Icilons apply only to the sample tested and/ot observed and are not necessarily indicative of the quantities of apparently identical or similar products.