MA1006-LR110614 (2)... LI N ICE r� GEOTECHNUIL Woo r Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C11-0509 Report Date: 06/14/2011 Project: Belt Line & Denton Tap Brick Paver Replacement Location: Texas Client: City of Coppell REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST Client PO: MA10-06 Set: 1 of 2 Type 1 Material: Concrete Type 5 Type 6 Location: NB Center Lane of Belt Line Slump: 5.0 Inches Transported By: Curing Method: Maximum Air Content: 3.2% Source/Sampled At: Spec Age Tested Diameter Area Load 83°F Mix: 93°F Cure Nbr (date : days) (in) (int) (Ibs) Break Type Loc A 06/14/11: 1 6.00 28.27 114,320 Type 3 Lab B 06/15/11: 2 6.00 28.27 122,645 Type 3 Lab C 06/20/11:7 6.00 28.27 Lab D 06/20/11:7 6.00 28.27 Lab E 07/11/11:28 6.00 28.27 Lab F 07/11/11:28 6.00 28.27 Lab Date Sampled: 06/13/2011 Sampled By: Whitney, Steve By Order Of: Rick O'Dell Order Number: 1770 LAB NO: 101836 Test Method: See Below Report No: 101836 Page 1 of 2 Number of Specimens: 6 Compressive Average Strength Strength (PSI) (PSI) Comments 4,040 4,040 4,340 4,340 Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 200 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Ong: City of Coppell (Coppell; TX) Attn: Mr- Rick O'Dell (1 -cc copy) 1 -cc City of Coppell Attn: Mr. George S. Marshall, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, Sr. Project Manager THIS REPORT .APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TEST ED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR T1 -1E EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED VOTHOUT WRITTEN PERMISSION. Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification: 5,000 psi @ 28 days Slump: 5.0 Inches Transported By: Curing Method: Standard Air Content: 3.2% Source/Sampled At: Time Sampled: 8:30 am Plant: LMC 3 Temp.: Ambient: 83°F Mix: 93°F Mix Code: 2125 Truck/Ticket No: 9140 / 3293088 Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 200 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Ong: City of Coppell (Coppell; TX) Attn: Mr- Rick O'Dell (1 -cc copy) 1 -cc City of Coppell Attn: Mr. George S. Marshall, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, Sr. Project Manager THIS REPORT .APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TEST ED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR T1 -1E EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED VOTHOUT WRITTEN PERMISSION. nLUntICE { E at. GROUr Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C11-0509 Report Date: 06/14/2011 Project: Belt Line & Denton Tap Brick Paver Replacement Location: Texas Client: City of Coppell REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST Client PO: MA10-06 TEST RESULTS Set: 2 of 2 Material: Concrete Location: Left Lane SB Belt Line At Denton Tap Date Sampled: 06/13/2011 Sampled By: Whitney, Steve By Order Of: Rick O'Dell Order Number: 1770 LAB NO: 101836 Test Method: See Below Report No: 101836 Page 2 of 2 Number of Specimens: 6 Compressive Average Strength Strength (PSI) (PSI) Comments 3,920 3,920 4,170 4,170 Maximum Spec Age Tested Diameter Area Load Cure Nbr (date : days) (in) (int) (Ibs) Break Type Loc A 06/14/11: 1 6.00 28.27 110,885 Type 3 Lab B 06/15/11: 2 6.00 28.27 117,995 Type 3 Lab C 06/20/11:7 6.00 28.27 Slump: 7.5 Inches Lab D 06/20/11:7 6.00 28.27 Time Sampled: 10:30 am Lab E 07/11/11:28 6.00 28.27 Truck/Ticket No: 3004 / 7219278 Lab F 07/11/11:28 6.00 28.27 Lab Date Sampled: 06/13/2011 Sampled By: Whitney, Steve By Order Of: Rick O'Dell Order Number: 1770 LAB NO: 101836 Test Method: See Below Report No: 101836 Page 2 of 2 Number of Specimens: 6 Compressive Average Strength Strength (PSI) (PSI) Comments 3,920 3,920 4,170 4,170 Quantity Represented: 10 cu. yds. at 110 Cu. yds. placed of a 200 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231 or C173, C1064 and C138. Compressive strenqth tests per ASTM C39. Ong: City of Coppell (Coppell. TX) Attn: Mr. Rick O'Dell (1 -cc copy 1 -cc City of Coppell Attn: Mr. George S. Marshall, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, Sr. Project Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES.. NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification: 5,000 psi @ 28 days Slump: 7.5 Inches Transported By: Curing Method: Standard Air Content: 4.5% Source/Sampled At: Time Sampled: 10:30 am Plant: LMC 1 Temp.: Ambient: 91°F Mix: 93°F Mix Code: 2125 Truck/Ticket No: 3004 / 7219278 Quantity Represented: 10 cu. yds. at 110 Cu. yds. placed of a 200 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231 or C173, C1064 and C138. Compressive strenqth tests per ASTM C39. Ong: City of Coppell (Coppell. TX) Attn: Mr. Rick O'Dell (1 -cc copy 1 -cc City of Coppell Attn: Mr. George S. Marshall, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, Sr. Project Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES.. NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.