Loading...
ST9902-LR150212� RLLIAI'ICE GGEOTECHI'IICRL GROUP _ Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C13-0634 Report Date: 02/12/2015 Project: West Sandy Lake Road Location: Top of wall tie-in from Coppell Rd. to Winding Hollow Lane, Sampled; 100' Going north from Winding Hollow Lane Client: City of Coppell REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST Material: Concrete Date Sampled: 02/11/2015 Sampled By: Marthers, J K By Order Of: Royse Order Number: 1770 Number of Specimens: 5 LAB NO: 180774 Test Method: See Below TEST RESULTS Report No: 180774 Specification Strength: 3,600 psi @ 28 days Slump: 3-5 Air Content: 3-6 Date Received: 02/12/2015 Curing Method: Standard Time Sampled: 10:15 am Time Batched: Page 1 of 1 Temp.: Ambient: 58°F Mix: 62°F Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Testec Nbr (date : days) (in) (ins) (Ibs) Break Type Loc (PSI) (PSI) By A 02/18/15: 7 6.00 28.27 85,510 Type 5 Lab 3,020 B 02/18/15: 7 6.00 28.27 87,365 Type 5 Lab 3,090 3,060 C 03/11/15:28 6.00 28.27 Lab D 03/11/15:28 6.00 28.27 Lab E Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 3,600 psi @ 28 days Slump: 3-5 Air Content: 3-6 Date Received: 02/12/2015 Curing Method: Standard Time Sampled: 10:15 am Time Batched: 8:58 am Temp.: Ambient: 58°F Mix: 62°F Slump: 7.0 Inches Air Content: 5.5% Mix Code: 8272 Comments HOLD (see remarks) - Transported By: TXI Source/Sampled At: Truck / Center Plant: 141 Truck/Ticket No: 0000 / 2671550 Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 10 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P E Respectfully Submitted, Alliance Geotechnical Group 16 ■ // f%J� /} , Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED ANDlOR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED_ THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.