NL Cypress-CS120321George-
Please see the attached revised exhibit for the traffic signal pole
foundations. We made some tweaks in the details to match the plan view
and keeping the pole foundations above ground 2.5’ away from the face of
curb and at least 2’ away from the water main and sanitary sewer main.
It’s my understanding that you want to try and avoid the block
foundations and put in a pier foundation as originally designed on the
west side, but we would have to move the pole closer towards the street
(i.e. closer than 2.5’). Even if we did move the pole, I would still
want to allow for an error of a few inches in the franchise utilities as
they were spot shot in several areas and we drew them in as best we
could. I recommend staying with the block foundation in order to keep
the pole further away from the street and allowing us to sleeve the
utilities through the block.
Please let me know your thoughts tomorrow morning if at all possible.
I called the owner’s representative for the office facility west of the
Belt Line and left a message. I will keep trying.
Thanks!
Bradley Moss, PE (TX, OK, NC), LEED® AP
12700 Park Central Drive
Dallas, Texas 75251
Ph: 972-770-1300 Fax: 972-239-3820
brad.moss@kimley-horn.com
From: El-Sadi, Tareq
Sent: Wednesday, March 21, 2012 6:09 PM
To: Moss, Brad
Subject: CW-Traffic Signal Exhibit
Brad,
Attached is the updated exhibit.