ST0502A-LR141222 p Q REEL? Er'lGIr1EERIr-1G
ircm,A GEOTECHNICAL AND G F9 O LJ P1� / r 7 � ENVIRONMENTAL CONSULTANTS
� .1_,P4'�
CONCRETE CYLINDER TEST REPORT
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 103
5430 LBJ Freeway, Suite 1030 REG PROJECT NO. 19763
Dallas, Texas 75240 SAMPLE DATE: 12-22-14
ATTN: Mr. Joe Williams TECHNICIAN: M. Roberts
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Location of Sample
Set Number Location Quantity Represented (c.y.)
1 Paving: 20'N, 100'E from NW building corner 30/70
Design Information
Source of Concrete Mix Identification Specified Strength (psi)
Argos 1569 3000
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
1 1977 12-29-14 7 45790 3640
1977 01-19-15 28 59870 4770
1977 01-19-15 28 56300 4480
1977 01-19-15 28 58490 4660 4640
1977 Hold H
Cylinder Data
Air Concrete Air Unit
Set Cylinder Slump Time of Temp. Temp. Entrainment Weight Ticket
No. ID (inches) Sample (°F) (°F) (%) (lbs/ft3) Number
1 1977 6.0 10:40 AM 54 58 4.3 143.6 1547122
Note: (1) Concrete was sampled in accordance with ASTM C-31
(2) Concrete cylinders were tested in accordance with ASTM C-39
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Bill Woolwine
Mr. Ron Harper Sr. Manager, CMT
(1) TAS Concrete/Mr. Matt Stickney CT/cn
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
REEL? I Er-IG I r-IEERIMG
GEOTECHNICAL AND G R O LI P
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 98
5430 LBJ Freeway, Suite 1030 REG PROJECT NO. 19763
Dallas, Texas 75240 SAMPLE DATE: 12-11-14
ATTN: Mr. Joe Williams TECHNICIAN: J. Newkirk
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Location of Sample I
Set Number Location Quantity Represented (c.y.)
1 Sidewalk: 5'N, 15'E from NW building corner 20/30
Design Information
Source of Concrete Mix Identification Specified Strength (psi)
Argos D10000001569 3500
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
1 1752 12-18-14 7 35570 2830
1752 01-08-15 28 53450 4250
1752 01-08-15 28 53050 4220
1752 01-08-15 28 54580 4340 4270
1752 Hold H
Cylinder Data
Air Concrete Air Unit
Set Cylinder Slump Time of Temp. Temp. Entrainment Weight Ticket
No. ID (inches) Sample (°F) (°F) (%) (lbs/ft3) Number
1 1752 6.0 10:35 AM 60 66 5.0 144.0 1541749
Note: (1) Concrete was sampled in accordance with ASTM C-31
(2) Concrete cylinders were tested in accordance with ASTM C-39
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Bill Woolwine
Mr. Ron Harper Sr. Manager, CMT
(1) TAS Concrete/Mr. Matt Stickney CT/cn
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS. TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
REED Ef1G I f-'IEERIf1G
GEOTECHNICAL AND GRD LJ P
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 99
5430 LBJ Freeway, Suite 1030 REG PROJECT NO. 19763
Dallas, Texas 75240 SAMPLE DATE: 12-15-14
ATTN: Mr. Joe Williams TECHNICIAN: D. Balderas
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Location of Sample
Set Number Location Quantity ltepresenter(c.y.)
1 Gate View Boulevard West approach 7/14
Design Information
Source of Concrete Mix Identification Specified Strength (psi)
Argos D11569 3500
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
1 1898 12-22-14 7 45100 3590
1898 01-12-15 28 59950 4770
1898 01-12-15 28 59070 4700
1898 01-12-15 28 61610 4900 4790
1898 Hold H
Cylinder Data
Air Concrete Air Unit
Set Cylinder Slump Time of Temp. Temp. Entrainment Weight Ticket
No. ID (inches) Sample (°F) (°F) (%) (lbs/ft3) Number
1 1898 4.5 8:53 AM 53 63 5.1 138.0 1543468
Note: (1) Concrete was sampled in accordance with ASTM C-31
(2) Concrete cylinders were tested in accordance with ASTM C-39
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Bill Woolwine
Mr. Ron Harper Sr. Manager, CMT
(1) TAS Concrete/Mr. Matt Stickney CT/cn
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
REEL? E (-1GIr-IEERII IG
GEOTECHNICAL AND G R O LJ P
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 88
5430 LBJ Freeway, Suite 1030 REG PROJECT NO. 19763
Dallas, Texas 75240 SAMPLE DATE: 12-04-14
ATTN: Mr. Joe Williams TECHNICIAN: R. Weathersby
PAGE: 1 of 2
CONTRACTOR: Raymond Construction
Location of Sample
Set Number Location Quantity Represented (c.y.)
1 Paving: 30'S, 125'W from SE building corner 50/540
2 Paving: 50'S, 85'W from SE building corner 150/540
3 Paving: 70'S, 85'W from SE building corner 250/540
4 Paving: 60'S, 10'E from SE building corner 350/540
5 Paving: 145'S, 15'W from NW building corner 460/540
Design Information
Source of Concrete Mix Identification Specified Strength (psi)
Argos D10000001569 3500
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
1 1475 12-11-14 7 49520 3940
1475 01-01-15 28 57020 4540
1475 01-01-15 28 61130 4870
1475 01-01-15 28 60780 4840 4750
1475 Hold H
2 1476 12-11-14 7 41580 3310
1476 01-01-15 28 55110 4390
1476 01-01-15 28 54610 4350
1476 01-01-15 28 52550 4180 4310
1476 Hold H
3 1477 12-11-14 7 39600 3150
1477 01-01-15 28 54490 4340
1477 01-01-15 28 51870 4130
1477 01-01-15 28 52500 4180 4220
1477 Hold H
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
4
REPORT NO. 88
REG PROJECT NO. 19763
SAMPLE DATE: 12-04-14
PAGE: 2 of 2
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
4 1478 12-11-14 7 46580 3710
1478 01-01-15 28 59820 4760
1478 01-01-15 28 59570 4740
1478 01-01-15 28 62990 5010 4840
1478 Hold H
5 1479 12-11-14 7 35940 2860
1479 01-01-15 28 50590 4030
1479 01-01-15 28 51100 4070
1479 01-01-15 28 47340 3770 3960
1479 Hold H
Cylinder Data
Air Concrete Air Unit
Set Cylinder Slump Time of Temp. Temp. Entrainment Weight Ticket
No. ID (inches) Sample (°F) (°F) (%) (lbs/ft3) Number
1 1475 4.5 3:15 AM 56 58 5.5 145.2 1536424
2 1476 4.75 4:40 AM 55 59 5.7 144.8 1556467
3 1477 4.5 6:10 AM 56 62 5.3 145.0 1536489
4 1478 4.25 7:40 AM 55 63 5.0 145.6 1536573
5 1479 4.75 10:30 AM 59 65 5.6 144.6 1536755
Note: (1) Concrete was sampled in accordance with ASTM C-31
(2) Concrete cylinders were tested in accordance with ASTM C-39
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Bill Woolwine
Mr. Ron Harper Sr. Manager, CMT
(1) TAS Concrete/Mr. Matt Stickney CT/cn
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
FEEL] Ei c i f'IEERur
GEOTECHNICAL AND G R 1=1 U I
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 89
5430 LBJ Freeway, Suite 1030 REG PROJECT NO. 19763
Dallas, Texas 75240 SAMPLE DATE: 12-05-14
ATTN: Mr. Joe Williams TECHNICIAN: D. Balderas
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Location of Sample
Set Number Location Quantity Represented (c.y.)
1 Sidewalk: 75'N, 50'E from NW building corner 10/30
Design Information
Source of Concrete Mix Identification Specified Strength (psi)
Argos D101043 3000
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
1 1543 12-12-14 7 44970 3580
1543 01-02-15 28 58030 4620
1543 01-02-15 28 56180 4470
1543 01-02-15 28 58050 4620 4570
1543 Hold H
Cylinder Data
Air Concrete Air Unit
Set Cylinder Slump Time of Temp. Temp. Entrainment Weight Ticket
No. ID (inches) Sample (°F) (°F) (%) (lbs/ft3) Number
1 1543 4.0 7:57 AM 66 73 5.3 138.0 1537760
Note: (1) Concrete was sampled in accordance with ASTM C-31
(2) Concrete cylinders were tested in accordance with ASTM C-39
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Bill Woolwine
Mr. Ron Harper Sr. Manager, CMT
(1) TAS Concrete/Mr. Matt Stickney CT/cn
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
FR 1=1 Er1G 11—IEEF� II—ICS
GEOTECHNICAL AND G Fi Q U P
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 90
5430 LBJ Freeway, Suite 1030 REG PROJECT NO. 19763
Dallas, Texas 75240 SAMPLE DATE: 12-05-14
ATTN: Mr. Joe Williams TECHNICIAN: D. Balderas
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Location of Sample
Set Number Location Quantity Represented (c.y.)
1 Slab leave-out: B.5-1 10/60
Design Information
Source of Concrete Mix Identification Specified Strength (psi)
Argos D101042 3000
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
1 1542 12-12-14 7 44860 3570
1542 01-02-15 28 61290 4880
1542 01-02-15 28 65450 5210
1542 01-02-15 28 61790 4920 5000
1542 Hold H
Cylinder Data
Air Concrete Air Unit
Set Cylinder Slump Time of Temp. Temp. Entrainment Weight Ticket
No. ID (inches) Sample (°F) (°F) (%) (lbs/ft3) Number
1 1542 4.0 11:07 AM 68 71 1.6 150.0 1538048
Note: (1) Concrete was sampled in accordance with ASTM C-31
(2) Concrete cylinders were tested in accordance with ASTM C-39
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Bill Woolwine
Mr. Ron Harper Sr. Manager, CMT
(1) TAS Concrete/Mr. Matt Stickney CT/cn
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
FREZ] EI—IGIr1EE1==4II—I1M
GEOTECHNICAL AND G R O LJ
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 93
5430 LBJ Freeway, Suite 1030 REG PROJECT NO. 19763
Dallas, Texas 75240 SAMPLE DATE: 12-08-14
ATTN: Mr. Joe Williams TECHNICIAN: T. Klien
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Location of Sample
Set Number Location Quantity Represented (c.y.)
1 Slab leave-out: G-4.9 40/70
Design Information
Source of Concrete Mix Identification Specified Strength (psi)
Southern Star 1042 3000
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
1 1702 12-15-14 7 54790 4360
1702 01-05-15 28 65360 5200
1702 01-05-15 28 63090 5020
1702 01-05-15 28 64680 5150 5120
1702 Hold H
Cylinder Data
Air Concrete Air Unit
Set Cylinder Slump Time of Temp. Temp. Entrainment Weight Ticket
No. ID (inches) Sample (°F) (°F) (%) (lbs/ft3) Number
1 1702 4.75 10:20 AM 53 64 1.5 149.0 1539031
Note: (1) Concrete was sampled in accordance with ASTM C-31
(2) Concrete cylinders were tested in accordance with ASTM C-39
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Bill Woolwine
Mr. Ron Harper Sr. Manager, CMT
(1) TAS Concrete/Mr. Matt Stickney CT/cn
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
1=1EE3E1 Ei is I f-IEERII—ICS
GEOTECHNICAL AND G O LJ P
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 94
5430 LBJ Freeway, Suite 1030 REG PROJECT NO. 19763
Dallas, Texas 75240 SAMPLE DATE: 12-08-14
ATTN: Mr. Joe Williams TECHNICIAN: T. Klein
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Location of Sample
Set Number Location Quantity Represented (c.y.)
1 Porch and Balcony: Line A to A.3, 2.5 to 3.2 80/80
Design Information
Source of Concrete Mix Identification Specified Strength (psi)
Southern Star 1042 3000
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
1 1703 12-15-14 7 48060 3820
1703 01-05-15 28 60660 4830
1703 01-05-15 28 55830 4440
1703 01-05-15 28 55590 4420 4560
1703 Hold H
Cylinder Data
Air Concrete Air Unit
Set Cylinder Slump Time of Temp. Temp. Entrainment Weight Ticket
No. ID (inches) Sample (°F) (°F) (%) (lbs/ft3) Number
1 1703 5.0 12:30 PM 53 62 1.0 150.0 1539162
Note: (1) Concrete was sampled in accordance with ASTM C-31
(2) Concrete cylinders were tested in accordance with ASTM C-39
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Bill Woolwine
Mr. Ron Harper Sr. Manager, CMT
(1) TAS Concrete/Mr. Matt Stickney CT/cn
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
REEL? E I I-1EERII I
GEOTECHNICAL AND G R Q LJ P
ENVIRONMENTAL CONSULTANTS
REPORT OF STRUCTURAL STEEL OBSERVATION
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 97
5430 LBJ Freeway, Suite 1030 REPORT DATE: 12-23-14
Dallas, Texas 75240 REG PROJECT NO. 19763
ATTN: Mr. Joe Williams DATE OBSERVED: 12-22-14
TECHNICIAN: J. Gray
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Location: Building at Lines A to J from 1 to 5
Non Code
Details Observed Compliant Compliant AWS D1.1 AISC Other
I)Visual weld verification of joist X X
seat to wall connections
(Reinspection)
Discrepancies/Comments: This reinspection clears Item lb of inspection conducted on
10-28-14, Report No. 70.
Other= Structural Drawings and E-mail dated 12-05-14
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ James D. Gray
Mr. Ron Harper C.W.I. 07081171
(1) TAS Concrete/Mr. Matt Stickney JG/sp
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 7510
REEL? E 1 FRIr-ic
GEOTECHNICAL AND G R O LJ 1=3
ENVIRONMENTAL CONSULTANTS
REPORT OF FIELD DENSITY TESTS
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 100
5430 LBJ Freeway, Suite 1030 REPORT DATE: 12-31-14
Dallas, Texas 75240 REG PROJECT NO. 19763
ATTN: Mr. Joe Williams TECHNICIAN: T. Klein
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Proctor ASTM Optimum Maximum
No. Standard Description Moisture, % Density, PCF
1 D-698 Dark brown clay 17.2 103.8
2 D-698 Reddish brown &yellowish brown clay 23.0 101.3
3 D-698 Dark brown sandy clay 16.6 107.2
4 D-698 Dark brown clay w/limestone fragments 13.4 114.4
5 D-698 Dark brown sandy clay w/gravel 18.1 106.0
6 D-698 Reddish brown clayey sand 14.6 110.0
7 D-698 Light brown sandy clay 16.5 105.5
Depth
Below Field Field
Test Final S. G. Density Moisture Proctor Compaction
No. Date Location (feet) (pcf) (%) ID Level (%)
97 12-08-14 Leave-out Interior: H.9-2.2 0.0 103.7 19.4 5 97.8
98 Leave-out Interior: H.9-2.3 0.0 102.9 20.2 5 97.1
Comments: Where tested, materials were in compliance with project specifications.
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/Mr. Ron Harper Bill Woolwine
(1) TAS Concrete/Mr. Matt Stickney Sr. Manager, CMT
(1) McHale Engineering/ BW/sp
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 7510
REEL? EMG I MEERIIIE,
GEOTECHNICAL AND G R Q LJ P
ENVIRONMENTAL CONSULTANTS
REPORT OF REINFORCING
STEEL PLACEMENT OBSERVATION
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 101
5430 LBJ Freeway, Suite 1030 REPORT DATE: 12-31-14
Dallas, Texas 75240 REG PROJECT NO. 19763
ATTN: Mr. Joe Williams DATE OBSERVED: 12-08-14
TECHNICIAN: T. Klein
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Items Observed: Leave-out: Line B to H.8 from 5.9 to 6
Reference Plans or Notes Used: Sheet S-9
X There were no deviations noted.
The reinforcing steel placed at the above referenced locations was observed with
respect to the referenced portions of the contract documents.
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Ronald F. Reed, P.E.
Mr. Ron Harper BW/sp
(1) TAS Concrete/Mr. Matt Stickney
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 7510
i=t EEL7 Er-IG 11-IEERir-ici
GEOTECHNICAL AND G R c LJ P
ENVIRONMENTAL CONSULTANTS
REPORT OF REINFORCING
STEEL PLACEMENT OBSERVATION
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 102
5430 LBJ Freeway, Suite 1030 REPORT DATE: 12-31-14
Dallas, Texas 75240 REG PROJECT NO. 19763
ATTN: Mr. Joe Williams DATE OBSERVED: 12-15-14
TECHNICIAN: D. Balderas
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Items Observed: Northwest approach and Northeast approach to Gate
View Boulevard
Reference Plans or Notes Used: The City of Coppell Standard, Detail 2190
X There were no deviations noted.
The reinforcing steel placed at the above referenced locations was observed with
respect to the referenced portions of the contract documents.
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Ronald F. Reed, P.E.
Mr. Ron Harper BW/sp
(1) TAS Concrete/Mr. Matt Stickney
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 7510
REEL1 Ef—IG I MEE1=1
GEOTECHNICAL AND G R O LJ P
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 103
5430 LBJ Freeway, Suite 1030 REG PROJECT NO. 19763
Dallas, Texas 75240 SAMPLE DATE: 12-22-14
ATTN: Mr. Joe Williams TECHNICIAN: M. Roberts
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Location of Sample
Set Number Location Quantity Represented (c.y.)
1 Paving: 20'N, 100'E from NW building corner 30/70
Design Information
Source of Concrete Mix Identification Specified Strength (psi)
Argos 1569 3000
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
1 1977 12-29-14 7 45790 3640
1977 01-19-15 28
1977 01-19-15 28
1977 01-19-15 28
1977 Hold H
Cylinder Data
Air Concrete Air Unit
Set Cylinder Slump Time of Temp. Temp. Entrainment Weight Ticket
No. ID (inches) Sample (°F) (°F) (%) (lbs/ft3) Number
1 1977 6.0 10:40 AM 54 58 4.3 143.6 1547122
Note: (1) Concrete was sampled in accordance with ASTM C-31
(2) Concrete cylinders were tested in accordance with ASTM C-39
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Bill Woolwine
Mr. Ron Harper Sr. Manager, CMT
(1) TAS Concrete/Mr. Matt Stickney CT/cn
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
REEL] EI—IC� I r"1EERIr1G
GEOTECHNICAL AND G R 1=1U1=1
ENVIRONMENTAL CONSULTANTS
REPORT OF STRUCTURAL STEEL OBSERVATION
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 96
5430 LBJ Freeway, Suite 1030 REPORT DATE: 12-23-14
Dallas, Texas 75240 REG PROJECT NO. 19763
ATTN: Mr. Joe Williams DATE OBSERVED: 12-19-14
TECHNICIAN: J. Gray
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Location: Building at Lines A to J from 1 to 5
Non Code
Details Observed Compliant Compliant AWS D1.1 AISC Other
I)Visual weld verification of deck
perimeter edge angle
(Reinspection)
Discrepancies/Comments: This reinspection clears Item 1111 of inspection conducted on
11-17-14, Report No. 75.
Other= Structural Drawings
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ James D. Gray
Mr. Ron Harper C.W.I. 07081171
(1) TAS Concrete/Mr. Matt Stickney JG/sp
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 7510
1=1EE3=1 EI—IG I r-IEEFZIr-1G
GEOTECHNICAL AND G U P
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 98
5430 LBJ Freeway, Suite 1030 REG PROJECT NO. 19763
Dallas, Texas 75240 SAMPLE DATE: 12-11-14
ATTN: Mr. Joe Williams TECHNICIAN: J. Newkirk
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Location of Sample _
Set Number I Location Quantity Represented (c.y.)
1 Sidewalk: 5'N, 15'E from NW building corner 20/30
Design Information
Source of Concrete Mix Identification Specified Strength (psi)
Argos D10000001569 3500
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
1 1752 12-18-14 7 35570 2830
1752 01-08-15 28
1752 01-08-15 28
1752 01-08-15 28
1752 Hold H
Cylinder Data
Air Concrete Air Unit
Set Cylinder Slump Time of Temp. Temp. Entrainment Weight Ticket
No. ID (inches) Sample (°F) (°F) (%) (lbs/ft3) Number
1 1752 6.0 10:35 AM 60 66 5.0 144.0 1541749
Note: (1) Concrete was sampled in accordance with ASTM C-31
(2) Concrete cylinders were tested in accordance with ASTM C-39
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Bill Woolwine
Mr. Ron Harper Sr. Manager, CMT
(1) TAS Concrete/Mr. Matt Stickney CT/cn
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
REELI Er1G I I—IEERII—IG
GEOTECHNICAL AND G R O LJ P
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 99
5430 LBJ Freeway, Suite 1030 REG PROJECT NO. 19763
Dallas, Texas 75240 SAMPLE DATE: 12-15-14
ATTN: Mr. Joe Williams TECHNICIAN: D. Balderas
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Location of Sample
Set Number Location Quantity Represented (c.y.)
1 Gate View Boulevard West approach 7/14
Design Information
Source of Concrete Mix Identification Specified Strength (psi)
Argos D11569 3500
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
1 1898 12-22-14 7 45100 3590
1898 01-12-15 28
1898 01-12-15 28
1898 01-12-15 28
1898 Hold H
Cylinder Data
Air Concrete Air Unit
Set Cylinder Slump Time of Temp. Temp. Entrainment Weight Ticket
No. ID (inches) Sample (°F) (°F) (%) .(lbs/ft3) Number
1 1898 4.5 8:53 AM 53 63 5.1 138.0 1543468
Note: (1) Concrete was sampled in accordance with ASTM C-31
(2) Concrete cylinders were tested in accordance with ASTM C-39
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Bill Woolwine
Mr. Ron Harper Sr. Manager, CMT
(1) TAS Concrete/Mr. Matt Stickney CT/cn
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
�
J\�O
O'�
6
Ok
� �Qti110• y defid p• �J�� ° eaict aQP� heO� 0 �0O �GAFee6as� e*c
NI
AG kri,
G C12'
GO ,��,LS GO,
5�G�� ° a G•
.`Q P,Gc. ese �e
0 e•t 50
�\e X03 a�a�ti‘ti °�20�°��50
5 ,�Zo X50
0d0eDP-
�Ft e��52�0 a�5 'S 0Q. S0
pip O��Oo ay��� , 5�• `�G�\o� • ��gco c�Beet d`'�`i po
��Qp� P c�`o��G �°oa ��,0�.\\a\�o, coy i�et S•e
T� �a� c\t C �� `0,\N\d \g' o
a
EZ 00 0`� �top C\ av\ \fie.
e s
Sc �, 2
Nc ��PG� 9a�•\e \�o;4) �1`L(0 ,\I•1���tdc��� t‘ o�Q<.'��` • `
Dr 10
4 G�� 0,,c‘o�o���et FQaa��g�oo��3�0�
,(\k‘
���oa�\° oad Stites4?�0
3 pC D,63�30
5 848 �5 ti�o� \e P--(e5� �5��'�30
848 �o'(0 o•(cG 5�`L
848
_•‘•w ck tie 2 �
848 Oe5`o�tce Pt•o ,�e�ey�� 3��0g0
848 S '02:' �'l D
�` D5 50
�ey�).\�dec 1� o��'�� pb���0
C tinder Data �2 0� Dt
' e4c- �� p, \r/- p$'� ti�
No. Cylinder Slump �o. �V' p, 10-�o �D 220 5r
ID inches S �` 3
Se
844 coN \' 0�'� p
2 845 5.0 2:3k <6p '\2 0�'N -I
3 846 5.5 3:45, g N� 0�'� 2�
5.25 �p �2�o\d
4 847 4:40 At,
$ 5 2
5 848 5.25 7:00 AM
2 �ps6 ,� N 2T)
4.75 8:50 AM \A
8b.D,5 \1-_0()-1�pc
Note: (1) Concrete 12 0�' p
(2) Concrete c as sampled in accorda► N2 05'�
cylinders SNS N _05'
�o\a
were tested in ac NS
E-Mail
Distribution: 3 a�N6
(1) OCT Industrial/Mr. p6
Joe Williams o
(1) DCT Industrial/S.
(1) Pross Design Montemayor
gn Group/Mr. Mark Pros .
oN
(1) Pross Design Group/B.
(1) Raymond Construction/
Mr.
\,\P
Mr. Leland Frantz
(1) Raymond Construction/ S�`-�Qoo
Mr. Ron HarperE
Sr.
(1) TAS Concrete/Mr. Matt SaS���°� .
(1) McHale En tickney CT/c
Mr. Gary Engineering/ Q.a�
Mail McHale
Distribution: (1) City of Coppell/Mr. Larry Davic
1=tEE =7 Ef-1G I f-IEERIrl
GEOTECHNICAL AND G FR O LJ F
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 74
5430 LBJ Freeway, Suite 1030 REG PROJECT NO. 19763
Dallas, Texas 75240 SAMPLE DATE: 11-12-14
ATTN: Mr. Joe Williams TECHNICIAN: S. Davis
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Location of Sample
Set Number Location Quantity Represented (c.y.)
1 Ramp walls: A.3-5 to A.3-5.8 and A.5-5 to A.5-5.8 10/10
Design Information
Source of Concrete Mix Identification Specified Strength (psi)
Argos 1569 3500
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
1 879 11-19-14 7 43230 3440
879 12-10-14 28 60380 4810
879 12-10-14 28 62160 4950
879 12-10-14 28 62330 4960 4910
879 Hold H
Cylinder Data
Air Concrete Air Unit
Set Cylinder Slump Time of Temp. Temp. Entrainment Weight Ticket
No. ID (inches) Sample (°F) (°F) (%) (lbs/ft3) Number
1 879 5.0 10:00 AM 42 55 4.0 146.6 1525096
Note: (1) Concrete was sampled in accordance with ASTM C-31
(2) Concrete cylinders were tested in accordance with ASTM C-39
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Bill Woolwine
Mr. Ron Harper Sr. Manager, CMT
(1) TAS Concrete/Mr. Matt Stickney CT/cn
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
REEL] Er1G I f-IEERII-1i
GEOTECHNICAL AND G R 17 LJ P
ENVIRONMENTAL CONSULTANTS
REPORT OF REINFORCING
STEEL PLACEMENT OBSERVATION
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 78
5430 LBJ Freeway, Suite 1030 REPORT DATE: 11-24-14
Dallas, Texas 75240 REG PROJECT NO. 19763
ATTN: Mr. Joe Williams DATE OBSERVED: 11-19-14
TECHNICIAN: M. Roberts
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Items Observed: Paving: 25'N, 25'W and 55'S-130'E from SW building
corner
Reference Plans or Notes Used: Sheets A1.0 and A1.1
X There were no deviations noted.
The reinforcing steel placed at the above referenced locations was observed with
respect to the referenced portions of the contract documents.
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Ronald F. Reed, P.E.
Mr. Ron Harper RFR/sp
(1) TAS Concrete/Mr. Matt Stickney
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 7510
or
FR EE 1=1 Er—iG 1 r1EERIr-1G
GEOTECHNICAL AND G R D Li P
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 81
5430 LBJ Freeway, Suite 1030 REG PROJECT NO. 19763
Dallas, Texas 75240 SAMPLE DATE: 11-19-14
ATTN: Mr. Joe Williams TECHNICIAN: M. Roberts
PAGE: 1 of 2
CONTRACTOR: Raymond Construction
Location of Sample
Set Number Location Quantity Represented (c.y.)
1 Paving: 7'N, 8'W from SW building corner 30/490
2 Paving: 10'S, 5'E from SW building corner 100/490
3 Paving: 20'S, 30'E from SW building corner 210/490
4 Paving: 24'S, 60'E from SW building corner 310/490
5 Paving: 28'S, 85'E from SW building corner 420/490
Design Information
Source of Concrete Mix Identification Specified Strength (psi)
Argos 1569 3500
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
1 1046 11-26-14 7 37380 2970
1046 12-17-14 28 53340 4250
1046 12-17-14 28 56410 4490
1046 12-17-14 28 52210 4160 4300
1046 Hold H
2 1047 11-26-14 7 29310 2330
1047 12-17-14 28 50580 4030
1047 12-17-14 28 46960 3740
1047 12-17-14 28 44000 3500 3760
1047 Hold H
3 1048 11-26-14 7 30090 2390
1048 12-17-14 28 50070 3990
1048 12-17-14 28 49060 3910
1048 12-17-14 28 46550 3710 3870
1048 Hold H
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
i.
REPORT NO. 81
REG PROJECT NO. 19763
SAMPLE DATE: 11-19-14
PAGE: 2 of 2
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
4 1049 11-26-14 7 42100 3350
1049 12-17-14 28 61710 4910
1049 12-17-14 28 64600 5140
1049 12-17-14 28 62520 4980 5010
1049 Hold H
5 1050 11-26-14 7 40760 3240
1050 12-17-14 28 51120 4070
1050 12-17-14 28 58570 4660
1050 12-17-14 28 52060 4140 4290
1050 Hold H
Cylinder Data
Air Concrete Air Unit
Set Cylinder Slump Time of Temp. Temp. Entrainment Weight Ticket
No. ID (inches) Sample (°F) (°F) (%) (lbs/ft3) Number
1 1046 5.5 1:30 AM 41 50 6.0 142.4 1528198
2 1047 8.0 2:30 AM 43 50 5.8 144.0 1528224
3 1048 8.0 4:00 AM 43 53 6.5 140.0 1528274
4 1049 6.5 5:30 AM 36 50 5.9 143.6 1528345
5 1050 8.0 7:00 AM 34 50 6.0 143.6 1528401
Note: (1) Concrete was sampled in accordance with ASTM C-31
(2) Concrete cylinders were tested in accordance with ASTM C-39
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Bill Woolwine
Mr. Ron Harper Sr. Manager, CMT
(1) TAS Concrete/Mr. Matt Stickney CT/cn
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
FR EE) EI-1GIr1EERIr'1G
GEOTECHNICAL AND G IR O U P
ENVIRONMENTAL CONSULTANTS
REPORT OF FIELD DENSITY TESTS
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 82
5430 LBJ Freeway, Suite 1030 REPORT DATE: 12-03-14
Dallas, Texas 75240 REG PROJECT NO. 19763
ATTN: Mr. Joe Williams TECHNICIAN: T. Klein
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Proctor ASTM Optimum Maximum
No. Standard Description Moisture, % Density, PCF
5 D-698 Dark brown sandy clay w/gravel 18.1 106.0
7 D-698 Light brown sandy clay 16.5 105.5
Depth
Below Field Field
Test Final S. G. Density Moisture Proctor Compaction
No. Date Location (feet) (pcf) (%) ID Level (%)
88 11-20-14 Interior Leave-out: A.6/4.9 0.0 101.4 20.6 5 95.7
89 Interior Leave-out: D.3/4.9 0.0 103.3 20.1 5 97.5
90 Interior Leave-out: G.6/4.9 0.0 102.7 20.4 5 96.9
91 Interior Leave-out: F.9/1.1 0.0 103.0 20.3 5 97.2
92 Interior Leave-out: D.3/1.1 0.0 102.2 20.2 5 96.4
93 Interior Leave-out: B.9/1.1 0.0 102.9 20.1 5 97.1
94 11-21-14 Leave-out: A.5/5 0.0 102.5 17.8 7 97.2
95 Leave-out: C.5/5 0.0 101.2 17.6 7 95.9
96 Leave-out: E.5/5 0.0 101.0 18.0 7 95.7
Comments: Where tested, materials were in compliance with project specifications.
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/Mr. Ron Harper Bill Woolwine
(1) TAS Concrete/Mr. Matt Stickney Sr. Manager, CMT
(1) McHale Engineering/ BW/jm
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
REEL] Er1G I r-1EERI1-1
GEOTECHNICAL AND G FR DLJ I='
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 83
5430 LBJ Freeway, Suite 1030 REG PROJECT NO. 19763
Dallas, Texas 75240 SAMPLE DATE: 11-20-14
ATTN: Mr. Joe Williams TECHNICIAN: J. Gray
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Location of Sample
Set Number Location Quantity Represented (c.y.)
1 South wall of north east ramp 10/20
Design Information
Source of Concrete Mix Identification Specified Strength (psi)
Argos 1569 3500
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
1 1080 11-27-14 7 32850 2610
1080 12-18-14 28 52080 4150
1080 12-18-14 28 49130 3910
1080 12-18-14 28 48450 3860 3970
1080 Hold H
Cylinder Data
Air Concrete Air Unit
Set Cylinder Slump Time of Temp. Temp. Entrainment Weight Ticket
No. ID (inches) Sample (°F) (°F) (%) (lbs/ft3) Number
1 1080 4.0 11:30 AM 52 56 4.3 147.4 1529999
Note: (1) Concrete was sampled in accordance with ASTM C-31
(2) Concrete cylinders were tested in accordance with ASTM C-39
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Bill Woolwine
Mr. Ron Harper Sr. Manager, CMT
(1) TAS Concrete/Mr. Matt Stickney CT/cn
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
REED I EI--IGII—IEERIr-i
GEOTECHNICAL AND G ROU P
ENVIRONMENTAL CONSULTANTS
REPORT OF FIELD DENSITY TESTS
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 85
5430 LBJ Freeway, Suite 1030 REPORT DATE: 12-12-14
Dallas, Texas 75240 REG PROJECT NO. 19763
ATTN: Mr. Joe Williams TECHNICIAN: T. Klein
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Proctor ASTM Optimum Maximum
No. Standard Description Moisture, % Density, PCF
5 D-698 Dark brown sandy clay w/gravel 18.1 106.0
Depth
Below Field Field
Test Final S. G. Density Moisture Proctor Compaction
No. Date Location (feet) (pcf) (%) ID Level (%)
97 12-01-14 Interior Leave-out: H.9/4.2 3.0 102.1 20.1 5 96.3
98 Interior Leave-out: H.9/4.3 2.0 103.4 19.3 5 97.5
99 Interior Leave-out: H.9/4.4 1.0 102.5 19.7 5 96.7
100 Interior Leave-out: H.9/4.5 0.0 102.9 19.5 5 97.1
Comments: Where tested, materials were in compliance with project specifications.
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/Mr. Ron Harper Bill Woolwine
(1) TAS Concrete/Mr. Matt Stickney Sr. Manager, CMT
(1) McHale Engineering/ BW/jm
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAx [214] 350 0019
REEa Er-1GIr"IEERIr1G
GEOTECHNICAL AND G R O LJ F3
ENVIRONMENTAL CONSULTANTS
REPORT OF REINFORCING
STEEL PLACEMENT OBSERVATION
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 86
5430 LBJ Freeway, Suite 1030 REPORT DATE: 12-15-14
Dallas, Texas 75240 REG PROJECT NO. 19763
ATTN: Mr. Joe Williams DATE OBSERVED: 12-04-14
TECHNICIAN: R. Weathersby
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Items Observed: Sidewalk: Section 1, 80-85'N, 10-95'E from NW
building corner and Section 2, 80-85'N, 15-215'W from
NE building corner.
Reference Plans or Notes Used: Sheet 2170
x There were no deviations noted.
The reinforcing steel placed at the above referenced locations was observed with
respect to the referenced portions of the contract documents.
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Ronald F. Reed, P.E.
Mr. Ron Harper BW/jm
(1) TAS Concrete/Mr. Matt Stickney
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
REEa I EriGIMEERII—IG
GEOTECHNICAL AND G R IDL I P
ENVIRONMENTAL CONSULTANTS
REPORT OF REINFORCING
STEEL PLACEMENT OBSERVATION
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 87
5430 LBJ Freeway, Suite 1030 REPORT DATE: 12-15-14
Dallas, Texas 75240 REG PROJECT NO. 19763
ATTN: Mr. Joe Williams DATE OBSERVED: 12-04-14
TECHNICIAN: R. Weathersby
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Items Observed: Paving: Section 1, 10'N-75'S, 165'W-145'E
from SE building corner and Section 2, 35'N-175'S, 0-
45'W from NW building corner.
Reference Plans or Notes Used: Sheet A1.0
x There were no deviations noted.
The reinforcing steel placed at the above referenced locations was observed with
respect to the referenced portions of the contract documents.
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Ronald F. Reed, P.E.
Mr. Ron Harper BW/jm
(1) TAS Concrete/Mr. Matt Stickney
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
1=1 Ef-IG I f1EEFRII-IG
GEOTECHNICAL AND G R O LJ P
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 88
5430 LBJ Freeway, Suite 1030 REG PROJECT NO. 19763
Dallas, Texas 75240 SAMPLE DATE: 12-04-14
ATTN: Mr. Joe Williams TECHNICIAN: R. Weathersby
PAGE: 1 of 2
CONTRACTOR: Raymond Construction
Location of Sample
Set Number Location Quantity Represented (c.y.)
1 Paving: 30'S, 125'W from SE building corner 50/540
2 Paving: 50'S, 85'W from SE building corner 150/540
3 Paving: 70'S, 85'W from SE building corner 250/540
4 Paving: 60'S, 10'E from SE building corner 350/540
5 Paving: 145'S, 15'W from NW building corner 460/540
Design Information
Source of Concrete Mix Identification Specified Strength (psi)
Argos D10000001569 3500
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
1 1475 12-11-14 7 49520 3940
1475 01-01-15 28
1475 01-01-15 28
1475 01-01-15 28
1475 Hold H
2 1476 12-11-14 7 41580 3310
1476 01-01-15 28
1476 01-01-15 28
1476 01-01-15 28
1476 Hold H
3 1477 12-11-14 7 39600 3150
1477 01-01-15 28
1477 01-01-15 28
1477 01-01-15 28
1477 Hold H
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
A
REPORT NO. 88
REG PROJECT NO. 19763
SAMPLE DATE: 12-04-14
PAGE: 2 of 2
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
4 1478 12-11-14 7 46580 3710
1478 01-01-15 28
1478 01-01-15 28
1478 01-01-15 28
1478 Hold H
5 1479 12-11-14 7 35940 2860
1479 01-01-15 28
1479 01-01-15 28
1479 01-01-15 28
1479 Hold H
Cylinder Data
Air Concrete Air Unit
Set Cylinder Slump Time of Temp. Temp. Entrainment Weight Ticket
No. ID (inches) Sample (°F) (°F) (%) (lbs/ft3) Number
1 1475 4.5 3:15 AM 56 58 5.5 145.2 1536424
2 1476 4.75 4:40 AM 55 59 5.7 144.8 1556467
3 1477 4.5 6:10 AM 56 62 5.3 145.0 1536489
4 1478 4.25 7:40 AM 55 63 5.0 145.6 1536573
5 1479 4.75 10:30 AM 59 65 5.6 144.6 1536755
Note: (1) Concrete was sampled in accordance with ASTM C-31
(2) Concrete cylinders were tested in accordance with ASTM C-39
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Bill Woolwine
Mr. Ron Harper Sr. Manager, CMT
(1) TAS Concrete/Mr. Matt Stickney CT/cn
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
1=4EEL7 EI IC I I—IE ERIflC
GEOTECHNICAL AND G R O U P
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 89
5430 LBJ Freeway, Suite 1030 REG PROJECT NO. 19763
Dallas, Texas 75240 SAMPLE DATE: 12-05-14
ATTN: Mr. Joe Williams TECHNICIAN: D. Balderas
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Location of Sample
Set Number Location Quantity Represented (c.y.)
1 Sidewalk: 75'N, 50'E from NW building corner 10/30
Design Information
Source of Concrete Mix Identification Specified Strength (psi)
Argos D101043 3000
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
1 1543 12-12-14 7 44970 3580
1543 01-02-15 28
1543 01-02-15 28
1543 01-02-15 28
1543 Hold H
Cylinder Data
Air Concrete Air Unit
Set Cylinder Slump Time of Temp. Temp. Entrainment Weight Ticket
No. ID (inches) Sample (°F) (°F) (%) (lbs/ft3) Number
1 1543 4.0 7:57 AM 66 73 5.3 138.0 1537760
Note: (1) Concrete was sampled in accordance with ASTM C-31
(2) Concrete cylinders were tested in accordance with ASTM C-39
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Bill Woolwine
Mr. Ron Harper Sr. Manager, CMT
(1) TAS Concrete/Mr. Matt Stickney CT/cn
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
FIEE =J E I Ir1G
GEOTECHNICAL AND G Fi O LI P
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 90
5430 LBJ Freeway, Suite 1030 REG PROJECT NO. 19763
Dallas, Texas 75240 SAMPLE DATE: 12-05-14
ATTN: Mr. Joe Williams TECHNICIAN: D. Balderas
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Location of Sample
Set Number Location Quantity Represented (c.y.)
1 Slab leave-out: B.5-1 10/60
Design Information
Source of Concrete Mix Identification Specified Strength (psi)
Argos D101042 3000
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
1 1542 12-12-14 7 44860 3570
1542 01-02-15 28
1542 01-02-15 28
1542 01-02-15 28
1542 Hold H
Cylinder Data
Air Concrete Air Unit
Set Cylinder Slump Time of Temp. Temp. Entrainment Weight Ticket
No. ID (inches) Sample (°F) (°F) (%) (lbs/ft3) Number
1 1542 4.0 11:07 AM 68 71 1.6 150.0 1538048
Note: (1) Concrete was sampled in accordance with ASTM C-31
(2) Concrete cylinders were tested in accordance with ASTM C-39
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Bill Woolwine
Mr. Ron Harper Sr. Manager, CMT
(1) TAS Concrete/Mr. Matt Stickney CT/cn
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
REELJ Ef'IGI r—IEERIr-lC�
GEOTECHNICAL AND GROUP
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 93
5430 LBJ Freeway, Suite 1030 REG PROJECT NO. 19763
Dallas, Texas 75240 SAMPLE DATE: 12-08-14
ATTN: Mr. Joe Williams TECHNICIAN: T. Klien
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Location of Sample
Set Number Location Quantity Represented (c.y.)
1 Slab leave-out: G-4.9 40/70
Design Information
Source of Concrete Mix Identification Specified Strength (psi)
Southern Star 1042 3000
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
1 1702 12-15-14 7 54790 4360
1702 01-05-15 28
1702 01-05-15 28
1702 01-05-15 28
1702 Hold H
Cylinder Data
Air Concrete Air Unit
Set Cylinder Slump Time of Temp. Temp. Entrainment Weight Ticket
No. ID (inches) Sample (°F) (°F) (%) (lbs/ft3) Number
1 1702 4.75 10:20 AM 53 64 1.5 149.0 1539031
Note: (1) Concrete was sampled in accordance with ASTM C-31
(2) Concrete cylinders were tested in accordance with ASTM C-39
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Bill Woolwine
Mr. Ron Harper Sr. Manager, CMT
(1) TAS Concrete/Mr. Matt Stickney CT/cn
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
REEL] EI—IG I r1EERIr1G
GEOTECHNICAL AND GROUP
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 94
5430 LBJ Freeway, Suite 1030 REG PROJECT NO. 19763
Dallas, Texas 75240 SAMPLE DATE: 12-08-14
ATTN: Mr. Joe Williams TECHNICIAN: T. Klein
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Location of Sample
Set Number Location Quantity Represented (c.y.)
1 Porch and Balcony: Line A to A.3, 2.5 to 3.2 80/80
Design Information
Source of Concrete Mix Identification Specified Strength (psi)
Southern Star 1042 3000
Test Results
Set Cylinder Age @ Total Load Compressive Average Strength
No. ID Date Tested Test (lbs.) Strength (psi) (psi)
1 1703 12-15-14 7 48060 3820
1703 01-05-15 28
1703 01-05-15 28
1703 01-05-15 28
1703 Hold H
Cylinder Data
Air Concrete Air Unit
Set Cylinder Slump Time of Temp. Temp. Entrainment Weight Ticket
No. ID (inches) Sample (°F) (°F) (°/a) (lbs/ft3) Number
1 1703 5.0 12:30 PM 53 62 1.0 150.0 1539162
Note: (1) Concrete was sampled in accordance with ASTM C-31
(2) Concrete cylinders were tested in accordance with ASTM C-39
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By
Mr. Leland Frantz
(1) Raymond Construction/ Bill Woolwine
Mr. Ron Harper Sr. Manager, CMT
(1) TAS Concrete/Mr. Matt Stickney CT/cn
(1) McHale Engineering/
Mr. Gary McHale
Mail
Distribution: (1) City of Coppell/Mr. Larry Davis
2424 STUTZ DR. • SUITE 400 • DALLAS, TX 75235 • TEL [214] 350 5600 • FAX [214] 350 0019
REEa l EIMMI lEEF;iinG
GEOTECHNICAL AND G R O U P
ENVIRONMENTAL CONSULTANTS
REPORT OF REINFORCING
STEEL PLACEMENT OBSERVATION
DCT Freeport North
1125 Gate View Boulevard
Coppell, Texas
REPORTED TO: DCT Industrial REPORT NO. 95
5430 LBJ Freeway, Suite 1030 REPORT DATE: 12-22-14
Dallas, Texas 75240 REG PROJECT NO. 19763
ATTN: Mr. Joe Williams DATE OBSERVED: 12-11-14
TECHNICIAN: J. Newkirk
PAGE: 1 of 1
CONTRACTOR: Raymond Construction
Items Observed: Sidewalk and entrances: 0-10'N, 10-25'E and
297-355'E from NW building corner.
Reference Plans or Notes Used: Sheets A1.0 and S.3, Detail 11
x There were no deviations noted.
The reinforcing steel placed at the above referenced locations was observed with
respect to the referenced portions of the contract documents.
E-Mail Submitted by:
Distribution: (1) DCT Industrial/Mr. Joe Williams
(1) DCT Industrial/S. Montemayor REED ENGINEERING GROUP, LTD.
(1) Pross Design Group/Mr. Mark Pross Registration Number F-3114
(1) Pross Design Group/B. Pross
(1) Raymond Construction/ Original Signed By