Belmont-LR141107Hooper Testing Laboratories, Inc.
Construction Materials Testing
REPORT OF CONCRETE TESTS
CLIENT: Pavecon Public Works, LP
PROJECT: Belmont Landing
Coppell, TX
LOCATION OF POUR:
JOB NO.: 14.1033
DATE: 7 November 2014
WEATHER: Clear, 70°F
SET 1: Curb and gutter on eastbound Belt Line Rd., east and west side of
emergency access road
SET 2:
SAMPLE DATA:
SET 1 SET 2
Truck No.
4209
Ticket No.
2545373
Time Batched
12:38 PM
Time Sampled
1:20 PM
Concrete Temp. (ASTM C1 064)
7'0°F
Air Content {ASTM 0231}
5.0%
Unit Weight (ASTM C1 38)
Pounds
SUPPLIER: TXI
Mix No.: 8275
Plant No.: 141
Time Start: 12:30 PIVI
Time Finished: 3:00 I'M
Concrete Placed: NIA
COMPRESSIVE STRENGTH TESTS
ASTM C31 cis
Standard 4" x 8" or 6" x 12"
cylinder)
Cylinder
Slump
Age
Test
Total Load
Compressive
Required
Number
inches
Days
Date
Pounds
Strength
28 -Day
ASTM C143
psi
Stream
137
3.50
7
11114/2014
41,000
3260
138
3.50
7
11/14/2014
41,900
3330
139
3.50
28
121512014
54,800
4360
140
3.50
28
12/5/2014
50,900
4050
28 -Day Average
4210
3600
TECHNICIAN: SET 1 - RLJ SET 2 -
REMARKS:
2870 Walnut HIII Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148