Belmont-LR141107Hooper Testing Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS CLIENT: Pavecon Public Works, LP PROJECT: Belmont Landing Coppell, TX LOCATION OF POUR: JOB NO.: 14.1033 DATE: 7 November 2014 WEATHER: Clear, 70°F SET 1: Curb and gutter on eastbound Belt Line Rd., east and west side of emergency access road SET 2: SAMPLE DATA: SET 1 SET 2 Truck No. 4209 Ticket No. 2545373 Time Batched 12:38 PM Time Sampled 1:20 PM Concrete Temp. (ASTM C1 064) 7'0°F Air Content {ASTM 0231} 5.0% Unit Weight (ASTM C1 38) Pounds SUPPLIER: TXI Mix No.: 8275 Plant No.: 141 Time Start: 12:30 PIVI Time Finished: 3:00 I'M Concrete Placed: NIA COMPRESSIVE STRENGTH TESTS ASTM C31 cis Standard 4" x 8" or 6" x 12" cylinder) Cylinder Slump Age Test Total Load Compressive Required Number inches Days Date Pounds Strength 28 -Day ASTM C143 psi Stream 137 3.50 7 11114/2014 41,000 3260 138 3.50 7 11/14/2014 41,900 3330 139 3.50 28 121512014 54,800 4360 140 3.50 28 12/5/2014 50,900 4050 28 -Day Average 4210 3600 TECHNICIAN: SET 1 - RLJ SET 2 - REMARKS: 2870 Walnut HIII Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148