Loading...
Belmont-LR140923Hooper Testing Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS JOB NO.: 14.1033 CLIENT: Pavecon Public Works, LP DATE: 23 September 2014 PROJECT: Belmont Landing WEATHER: Clear Coppell, TX 57-82°F LOCATION OF POUR: SET 1: Paving emergency access drive, from 90'-110' north of Prescott Lane and east line to west line SET 2: SAMPLE DATA: SET 1 Truck No. 3035 Ticket No. 1495958 Time Batched 8:30 AM Time Sampled 9:20 AM Concrete Temp. (ASTM C1064) 85'F Air Content (ASTM C231) 4.5% Unit Weight (ASTM 0138) SET 2 SUPPLIER: Argos Mix No.: 1395 Plant No.: 110 Time Start: 8:00 AM Time Finished: 11:30 AM Concrete Placed: NIA COMPRESSIVE STRENGTH TESTS (ASTM C31, C39) (Standard 4" x 8" or 6" x 12" cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28 -Day (ASTM 0143) pal Strength 125 5.50 7 126 5.50 7 127 5.50 28 128 5.50 28 *4000 psi mix used. 9/3012014 59,600 4740 9/30/2014 63,700 5470 10/21/2014 10/2112014 28 -Day Average 3600* TECHNICIAN: SET 1 - RL,J SET 2 - REMARKS: Calor agent added to concrete at jobsite. 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148