Loading...
Westhaven 2-LR140716Concrete Compression Test Report 2209 Wisconsin St., Suite 100 Dallas, TX 75229 (972)620-8911 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:SIDEWALK, TERRACE PARK @ SW SIDE OF BLOCK K, LOT 6 Project Desc:WESTHAVEN PHASE 1 & 2 - MASS GRADING OFF STATE HWY 121 AND WESTHAVEN RD. Our Report #:130127-146 STANDARD PACIFIC HOMES - IRVING 909 LAKE CAROLYN PARKWAY #1700 IRVING, TX 75039 CHIP BOYDATTN: (972) 550-7891Fax Number: Date Placed:6/18/2014 Time Placed:1:00 PM 5.0 N/A 87 94 Date Received:6/19/2014 Concrete Supplier:LMC Submitted By:Romeo Martinez Plant Number:956 Delivery Ticket No.:63082177 N/A Batch Time:12:30:00 PM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:5022 Break Type: Sample Location:50'N & 50'W FROM SW CORNER OF BLOCK K, LOT 6 PM:ATTEF ABUSHAKRA, P.E. Date Issued:07/16/2014 Specified Strength:3000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 49 6/25/2014 7 4308012.56 3430LABC-1231 8 N/A 43 50 7/16/2014 28 5453012.56 4340LABC-1231 8 N/A 43 51 7/16/2014 28 5876012.56 4680LABC-1231 8 N/A 43 52 7/16/2014 28 6009012.56 4780LABC-1231 8 N/A 42 Average 28-day Compressive Strength is compliant with project specifications CC:City of Coppell 4600 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 177861 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.