Loading...
Westhaven 2-LR140704TESTED FOR:DATE: 07/04/14 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 2600 07/04/14 FG-1.5 8 13.1 113.7 14.9 110 96 1-A 2601 07/04/14 FG-1.5 8 13.1 113.7 14.0 110 97 1-A 2602 07/04/14 FG-1.5 8 13.1 113.7 15.0 109 96 1-A 2603 07/04/14 FG-1.0 8 13.1 113.7 15.4 111 98 1-A 2604 07/04/14 FG-1.0 8 13.1 113.7 13.7 108 95 1-A 2605 07/04/14 FG 8 13.1 113.7 14.1 111 97 1-A 2606 07/04/14 FG-1.0 8 13.1 113.7 13.6 109 96 1-A TEST LOCATION:Building Pad 2600 2601 2602 2603 2604 2605 2606 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. 20' N and 80' E from the SW Corner of Block F, Pad 18 30' N and 40' E from the SW Corner of Block F, Pad 23 20' N and 10' E from the SW Corner of Block F, Pad 24 40' N and 20' E from the SW Corner of Block F, Pad 26 Irving, Texas COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % PERCENT COMPACTION SOIL ID NUMBER COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving 130127-153 DATE 10' N and 30' E from the SW Corner of Block F, Pad 25 IN PLACE DRY DENSITY PCF Westhaven Phase 1 & 2 - Mass Grading Coppell, Texas TECHNICIAN: 30' N and 40' E from the SW Corner of Block F, Pad 27 TEST NO. 40' N and 30' E from the SW Corner of Block F, Pad 22 J. Ranjbaran TESTED FOR:DATE: 07/04/14 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 2607 07/04/14 FG-1.0 8 13.1 113.7 14.7 113 99 1-A 2608 07/04/14 FG-1.0 8 13.1 113.7 13.4 110 97 1-A 2609 07/04/14 FG-1.0 8 13.1 113.7 13.6 113 99 1-A 2610 07/04/14 FG-1.0 8 13.1 113.7 14.7 110 97 1-A 2611 07/04/14 FG-1.0 8 13.1 113.7 15.6 110 97 1-A 2612 07/04/14 FG-1.0 8 13.1 113.7 14.4 113 99 1-A 2613 07/04/14 FG-0.5 8 13.1 113.7 13.8 111 98 1-A TEST LOCATION:Building Pad 2607 2608 2609 2610 2611 2612 2613 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. TECHNICIAN: J. Ranjbaran REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 COMPACTION TESTS Standard Pacific Homes - Irving Irving, Texas Westhaven Phase 1 & 2 - Mass Grading 130127-153A Coppell, Texas 20' N and 50' W from the SE Corner of Block F, Pad 20 40' N and 20' W from the SE Corner of Block F, Pad 21 TEST NO.DATE SOIL ID NUMBER OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT* 30' N and 30' W from the SE Corner of Block F, Pad 19 30' N and 40' W from the SE Corner of Block F, Pad 22 50' N and 30' W from the SE Corner of Block F, Pad 23 20' N and 10' W from the SE Corner of Block F, Pad 24 40' N and 30' W from the SE Corner of Block F, Pad 25 TESTED FOR:DATE: 07/04/14 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 2600 07/04/14 FG-1.5 8 13.1 113.7 14.9 110 96 1-A 2601 07/04/14 FG-1.5 8 13.1 113.7 14.0 110 97 1-A 2602 07/04/14 FG-1.5 8 13.1 113.7 15.0 109 96 1-A 2603 07/04/14 FG-1.0 8 13.1 113.7 15.4 111 98 1-A 2604 07/04/14 FG-1.0 8 13.1 113.7 13.7 108 95 1-A 2605 07/04/14 FG 8 13.1 113.7 14.1 111 97 1-A 2606 07/04/14 FG-1.0 8 13.1 113.7 13.6 109 96 1-A TEST LOCATION:Building Pad 2600 2601 2602 2603 2604 2605 2606 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. 20' N and 80' E from the SW Corner of Block F, Pad 18 30' N and 40' E from the SW Corner of Block F, Pad 23 20' N and 10' E from the SW Corner of Block F, Pad 24 40' N and 20' E from the SW Corner of Block F, Pad 26 Irving, Texas COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % PERCENT COMPACTION SOIL ID NUMBER COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving 130127-153 DATE 10' N and 30' E from the SW Corner of Block F, Pad 25 IN PLACE DRY DENSITY PCF Westhaven Phase 1 & 2 - Mass Grading Coppell, Texas TECHNICIAN: 30' N and 40' E from the SW Corner of Block F, Pad 27 TEST NO. 40' N and 30' E from the SW Corner of Block F, Pad 22 J. Ranjbaran TESTED FOR:DATE: 07/04/14 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 2607 07/04/14 FG-1.0 8 13.1 113.7 14.7 113 99 1-A 2608 07/04/14 FG-1.0 8 13.1 113.7 13.4 110 97 1-A 2609 07/04/14 FG-1.0 8 13.1 113.7 13.6 113 99 1-A 2610 07/04/14 FG-1.0 8 13.1 113.7 14.7 110 97 1-A 2611 07/04/14 FG-1.0 8 13.1 113.7 15.6 110 97 1-A 2612 07/04/14 FG-1.0 8 13.1 113.7 14.4 113 99 1-A 2613 07/04/14 FG-0.5 8 13.1 113.7 13.8 111 98 1-A TEST LOCATION:Building Pad 2607 2608 2609 2610 2611 2612 2613 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. TECHNICIAN: J. Ranjbaran REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 COMPACTION TESTS Standard Pacific Homes - Irving Irving, Texas Westhaven Phase 1 & 2 - Mass Grading 130127-153A Coppell, Texas 20' N and 50' W from the SE Corner of Block F, Pad 20 40' N and 20' W from the SE Corner of Block F, Pad 21 TEST NO.DATE SOIL ID NUMBER OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT* 30' N and 30' W from the SE Corner of Block F, Pad 19 30' N and 40' W from the SE Corner of Block F, Pad 22 50' N and 30' W from the SE Corner of Block F, Pad 23 20' N and 10' W from the SE Corner of Block F, Pad 24 40' N and 30' W from the SE Corner of Block F, Pad 25