Westhaven 2-LR130627Concrete Compression Test
Report
2209 Wisconsin St., Suite 100
Dallas, TX 75229
(972)620-8911
Alpha Testing, Inc.
TBPE Firm No. 813
Project Desc:WESTHAVEN PHASE 1 & 2 - MASS GRADING
OFF STATE HWY 121 AND WESTHAVEN RD.
Our Report No.:130127-117
FIELD DATA
STANDARD PACIFIC HOMES - IRVING
909 LAKE CAROLYN PARKWAY #1700
IRVING, TX 75039
CHIP BOYDATTN:
(972) 550-7891Fax Number:
Placement Location:JUNCTION BOX
Date Placed:6/27/2013
Time Placed:3:00 PM
Slump (ASTM C-143):3.5
Air Content:N/A
Air Temperature:98
Specimen Temperature:98
Date Received:6/28/2013
Mix Data Submitted By:TXI
Field Data Submitted By:Shrestha, Arbind
Plant Number:141
Delivery Ticket No.:1773768
Tested For:
Lab
No.:
Cure
Type:
Date
Tested:
Age
(Days):
Max
Load:
Area:
Sq. In.PSI:
Cap
Spec:
CYLINDER COMPRESSION TEST RESULTS
Avg.
Length
Avg.
Width
Avg Depth/
Diameter
Made By:ALPHA
Cured Specification:ASTM C-31
Mix ID:8274
Break
Type:
Sample Location:LINE PD-2 @ STATION 1+94
PM:ATTEF ABUSHAKRA, P.E.
29 7/4/2013 7 5949012.56 4740LABC-1231 8 N/A 42
30 7/25/2013 28 7009012.56 5580LABC-1231 8 N/A 43
31 7/25/2013 28 7196012.56 5730LABC-1231 8 N/A 42
32 7/25/2013 28 7413012.56 5900LABC-1231 8 N/A 42
Specifications:28
FAIL BYResults to Date:
CC:City of Coppell
Fails to meet ACI Guidelines (ACI 306, Section 6.5, Figure 6.5) of Obtaining 60% in 7 Days. Faxed Data To:
Client Representative Notified of Low Concrete Compression Test Results. Faxed Data To:
Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc.
Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 153535
Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064 AND C138. Compression strength tests per
ASTM C39. Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or
distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the
samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens.