Loading...
Westhaven 2-LR130513TESTED FOR:DATE: 05/13/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 2112 05/13/13 FG-5.0 8 13.1 113.7 14.6 113 99 1-A 2113 05/13/13 FG-4.0 8 13.1 113.7 14.8 112 98 1-A 2114 05/13/13 FG-3.0 8 13.1 113.7 17.4 109 96 1-A 2115 05/13/13 FG-2.0 8 13.1 113.7 13.6 113 100 1-A 2116 05/13/13 FG-1.0 8 13.1 113.7 14.9 113 99 1-A 2117 05/13/13 FG-5.0 8 13.1 113.7 14.0 115 101 1-A 2118 05/13/13 FG-4.0 8 13.1 113.7 17.3 109 96 1-A TEST LOCATION: 2112 2113 2114 2115 2116 2117 2118 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. D. Hinton 130127-99 COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Phase 1 & 2 - Mass Grading Coppell, Texas TECHNICIAN: DATETEST NO. Sanitary Sewer Line A at Station 27+58 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER Sanitary Sewer Line A at Station 27+50 Sanitary Sewer Line A at Station 30+00 Sanitary Sewer Line A at Station 30+02 Sanitary Sewer Line A at Station 27+52 Sanitary Sewer Line A at Station 27+55 Sanitary Sewer Line A at Station 27+60 COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving Irving, Texas TESTED FOR:DATE: 05/13/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 2119 05/13/13 FG-3.0 8 13.1 113.7 14.3 113 99 1-A 2120 05/13/13 FG-2.0 8 13.1 113.7 17.4 108 95 1-A 2121 05/13/13 FG-1.0 8 13.1 113.7 16.4 110 96 1-A 2122 05/13/13 FG-5.0 8 13.1 113.7 16.1 111 98 1-A 2123 05/13/13 FG-4.0 8 13.1 113.7 17.2 109 96 1-A 2124 05/13/13 FG-3.0 5 14.4 111.9 17.4 109 97 1-A 2125 05/13/13 FG-2.0 5 14.4 111.9 16.7 110 98 1-A TEST LOCATION: 2119 2120 2121 2122 2123 2124 2125 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving Irving, Texas Sanitary Sewer Line A at Station 32+55 Sanitary Sewer Line A at Station 32+58 Sanitary Sewer Line A at Station 30+08 Sanitary Sewer Line A at Station 30+10 Sanitary Sewer Line A at Station 32+52 DATETEST NO. Sanitary Sewer Line A at Station 32+50 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER Sanitary Sewer Line A at Station 30+05 D. Hinton 130127-99A COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Phase 1 & 2 - Mass Grading Coppell, Texas TECHNICIAN: TESTED FOR:DATE: 05/13/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 2126 05/13/13 FG-1.0 5 14.4 111.9 18.3 108 97 1-A 2127 05/13/13 FG-5.0 6 18.6 102.8 22.2 100 97 1-A 2128 05/13/13 FG-4.0 6 18.6 102.8 21.0 102 99 1-A 2129 05/13/13 FG-3.0 6 18.6 102.8 20.9 100 98 1-A 2130 05/13/13 FG-2.0 6 18.6 102.8 19.6 102 99 1-A 2131 05/13/13 FG-1.0 6 18.6 102.8 20.5 102 100 1-A TEST LOCATION: 2126 2127 2128 2129 2130 2131 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. D. Hinton 130127-99B COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Phase 1 & 2 - Mass Grading Coppell, Texas TECHNICIAN: DATETEST NO. Sanitary Sewer Manhole Line A at Station 34+99, South Side IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER Sanitary Sewer Line A at Station 32+10 Sanitary Sewer Manhole Line A at Station 34+99, North Side Sanitary Sewer Manhole Line A at Station 34+99, North Side Sanitary Sewer Manhole Line A at Station 34+99, East Side Sanitary Sewer Manhole Line A at Station 34+99, West Side COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving Irving, Texas