Loading...
Westhaven 2-LR130502TESTED FOR:DATE: 05/02/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 2000 05/02/13 FG-5.0 7 15.1 110.1 18.2 109 99 1-A 2001 05/02/13 FG-4.0 7 15.1 110.1 18.0 108 98 1-A 2002 05/02/13 FG-3.0 7 15.1 110.1 18.5 108 98 1-A 2003 05/02/13 FG-2.0 7 15.1 110.1 16.7 111 101 1-A 2004 05/02/13 FG-1.0 7 15.1 110.1 18.7 106 96 1-A 2005 05/02/13 FG-8.0 7 15.1 110.1 17.4 110 100 1-A 2006 05/02/13 FG-7.0 7 15.1 110.1 18.1 109 99 1-A TEST LOCATION: Phase 2 Utilities 2000 2001 2002 2003 2004 2005 2006 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. D. Hinton 130127-93 COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Phase 1 & 2 - Mass Grading Coppell, Texas TECHNICIAN: DATETEST NO. Sanitary Sewer Line A at Station 11+10 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER Sanitary Sewer Line A at Station 11+00 Sanitary Sewer Line A at Station 14+00 Sanitary Sewer Line A at Station 14+05 Sanitary Sewer Line A at Station 11+05 Sanitary Sewer Line A at Station 11+08 Sanitary Sewer Line A at Station 11+15 COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving Irving, Texas TESTED FOR:DATE: 05/02/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 2007 05/02/13 FG-6.0 1 11.9 117.9 13.7 114 97 1-A 2008 05/02/13 FG-5.0 1 11.9 117.9 13.4 113 96 1-A 2009 05/02/13 FG-4.0 1 11.9 117.9 13.8 113 96 1-A 2010 05/02/13 FG-3.0 7 15.1 110.1 17.8 109 99 1-A 2011 05/02/13 FG-2.0 7 15.1 110.1 17.0 109 99 1-A 2012 05/02/13 FG-1.0 7 15.1 110.1 17.4 109 99 1-A 2013 05/02/13 FG-7.0 7 15.1 110.1 16.3 111 101 1-A TEST LOCATION: Phase 2 Utilities 2007 2008 2009 2010 2011 2012 2013 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving Irving, Texas Sanitary Sewer Line A at Station 14+20 Sanitary Sewer Line A at Station 16+00 Sanitary Sewer Line A at Station 14+10 Sanitary Sewer Line A at Station 14+12 Sanitary Sewer Line A at Station 14+16 DATETEST NO. Sanitary Sewer Line A at Station 14+15 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER Sanitary Sewer Line A at Station 14+08 D. Hinton 130127-93A COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Phase 1 & 2 - Mass Grading Coppell, Texas TECHNICIAN: TESTED FOR:DATE: 05/02/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 2014 05/02/13 FG-6.0 7 15.1 110.1 16.7 110 100 1-A 2015 05/02/13 FG-5.0 7 15.1 110.1 17.3 108 98 1-A 2016 05/02/13 FG-4.0 7 15.1 110.1 17.7 107 97 1-A 2017 05/02/13 FG-3.0 7 15.1 110.1 17.8 107 97 1-A 2018 05/02/13 FG-2.0 7 15.1 110.1 18.4 106 96 1-A 2019 05/02/13 FG-1.0 7 15.1 110.1 17.8 109 99 1-A TEST LOCATION: Phase 2 Utilities 2014 2015 2016 2017 2018 2019 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. D. Hinton 130127-93B COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Phase 1 & 2 - Mass Grading Coppell, Texas TECHNICIAN: DATETEST NO. Sanitary Sewer Line A at Station 16+12 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER Sanitary Sewer Line A at Station 16+05 Sanitary Sewer Line A at Station 16+00 Sanitary Sewer Line A at Station 16+08 Sanitary Sewer Line A at Station 16+10 Sanitary Sewer Line A at Station 16+15 COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving Irving, Texas