Westhaven 2-LR130503TESTED FOR:DATE: 05/03/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 1986 05/03/13 FG-7.0 7 15.1 110.1 18.1 107 97 1-A 1987 05/03/13 FG-6.0 7 15.1 110.1 17.7 107 97 1-A 1988 05/03/13 FG-5.0 7 15.1 110.1 17.6 108 98 1-A 1989 05/03/13 FG-4.0 7 15.1 110.1 17.2 109 99 1-A 1990 05/03/13 FG-3.0 7 15.1 110.1 17.9 108 98 1-A 1991 05/03/13 FG-2.0 7 15.1 110.1 18.5 108 98 1-A 1992 05/03/13 FG-1.0 7 15.1 110.1 18.6 106 97 1-A TEST LOCATION:Phase 2 Utilities 1986 1987 1988 1989 1990 1991 1992 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Don Hinton 130127-92 COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Phase 1 & 2 - Mass Grading Coppell, Texas TECHNICIAN: DATETEST NO. Sanitary Sewer Service to Block E, Pad 30 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER Sanitary Sewer Service to Block E, Pad 30 Sanitary Sewer Service to Block E, Pad 30 Sanitary Sewer Service to Block E, Pad 30 Sanitary Sewer Service to Block E, Pad 30 Sanitary Sewer Service to Block E, Pad 30 Sanitary Sewer Service to Block E, Pad 30 COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving Irving, Texas TESTED FOR:DATE: 05/03/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 1993 05/03/13 FG-8.0 1 11.9 117.9 15.2 113 96 1-A 1994 05/03/13 FG-7.0 5 14.4 111.9 17.5 111 100 1-A 1995 05/03/13 FG-6.0 5 14.4 111.9 18.0 111 99 1-A 1996 05/03/13 FG-5.0 5 14.4 111.9 18.2 110 98 1-A 1997 05/03/13 FG-4.0 5 14.4 111.9 17.4 109 98 1-A 1998 05/03/13 FG-3.0 5 14.4 111.9 17.8 108 96 1-A 1999 05/03/13 FG-2.0 5 14.4 111.9 16.7 109 98 1-A TEST LOCATION:Phase 2 Utilities 1993 1994 1995 1996 1997 1998 1999 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving Irving, Texas Sanitary Sewer Line A at Station 18+12 Sanitary Sewer Line A at Station 18+15 Sanitary Sewer Line A at Station 18+02 Sanitary Sewer Line A at Station 18+05 Sanitary Sewer Line A at Station 18+10 DATETEST NO. Sanitary Sewer Line A at Station 18+08 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER Sanitary Sewer Line A at Station 18+00 Don Hinton 130127-92A COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Phase 1 & 2 - Mass Grading Coppell, Texas TECHNICIAN: