Loading...
Westhaven 2-LR130219TESTED FOR:DATE: 02/19/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 657 02/19/13 EG-3.0 1 11.9 117.9 13.0 116 98 1-A 658 02/19/13 EG-2.0 1 11.9 117.9 14.0 115 97 1-A 659 02/19/13 EG-3.0 1 11.9 117.9 13.7 115 98 1-A 660 02/19/13 EG-2.0 1 11.9 117.9 14.0 114 97 1-A 661 02/19/13 EG-3.0 1 11.9 117.9 13.9 114 97 1-A 662 02/19/13 EG-2.0 1 11.9 117.9 13.2 114 97 1-A 663 02/19/13 EG-3.0 1 11.9 117.9 13.4 115 98 1-A TEST LOCATION: 657 658 659 660 661 662 663 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Don Hinton 130127-39 COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Coppell, Texas TECHNICIAN: DATETEST NO. 40' S and 15' W from the NE Corner of Block M, Pad 4 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER 40' S and 15' W from the NE Corner of Block M, Pad 1 40' S and 15' W from the NE Corner of Block M, Pad 6 40' S and 15' W from the NE Corner of Block M, Pad 7 40' S and 15' W from the NE Corner of Block M, Pad 2 40' S and 15' W from the NE Corner of Block M, Pad 3 40' S and 15' W from the NE Corner of Block M, Pad 5 COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving Irving, Texas TESTED FOR:DATE: 02/19/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 664 02/19/13 EG-2.0 1 11.9 117.9 13.4 113 96 1-A 665 02/19/13 EG-1.0 1 11.9 117.9 12.5 116 98 1-A 666 02/19/13 EG-2.0 1 11.9 117.9 12.0 115 98 1-A 667 02/19/13 EG-1.0 5 14.4 111.9 15.6 108 97 1-A 668 02/19/13 EG-2.0 5 14.4 111.9 16.0 108 97 1-A 669 02/19/13 EG-1.0 5 14.4 111.9 15.6 109 98 1-A 670 02/19/13 EG-2.0 5 14.4 111.9 16.3 107 95 1-A TEST LOCATION: 664 665 666 667 668 669 670 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving Irving, Texas 30' N and 15' E from the SW Corner of Block M, Pad 4 30' N and 15' E from the SW Corner of Block M, Pad 3 30' N and 15' E from the SW Corner of Block M, Pad 8 30' N and 15' E from the SW Corner of Block M, Pad 7 30' N and 15' E from the SW Corner of Block M, Pad 5 DATETEST NO. 30' N and 15' E from the SW Corner of Block M, Pad 6 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER 40' S and 15' W from the NE Corner of Block M, Pad 8 Don Hinton 130127-39A COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Coppell, Texas TECHNICIAN: TESTED FOR:DATE: 02/19/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 671 02/19/13 EG-1.0 5 14.4 111.9 15.6 107 96 1-A 672 02/19/13 EG-2.0 5 14.4 111.9 15.2 108 97 1-A 673 02/19/13 EG-4.0 4 18.1 104.8 19.2 104 99 1-A 674 02/19/13 EG-5.0 4 18.1 104.8 19.8 105 100 1-A 675 02/19/13 EG-4.0 4 18.1 104.8 23.4 100 96 1-A 676 02/19/13 EG-5.0 4 18.1 104.8 22.5 101 96 1-A 677 02/19/13 EG-4.0 4 18.1 104.8 21.7 103 99 1-A TEST LOCATION: 671 672 673 674 675 676 677 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Don Hinton 130127-39B COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Coppell, Texas TECHNICIAN: DATETEST NO. 25' S and 45' W from the NE Corner of Block H, Pad 17 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER 30' N and 15' E from the SW Corner of Block M, Pad 2 25' S and 45' W from the NE Corner of Block H, Pad 19 25' S and 45' W from the NE Corner of Block H, Pad 20 30' N and 15' E from the SW Corner of Block M, Pad 1 25' S and 45' W from the NE Corner of Block H, Pad 16 25' S and 45' W from the NE Corner of Block H, Pad 18 COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving Irving, Texas TESTED FOR:DATE: 02/19/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 678 02/19/13 EG-5.0 4 18.1 104.8 22.2 102 98 1-A 679 02/19/13 EG-3.0 4 18.1 104.8 22.0 104 99 1-A 680 02/19/13 EG-4.0 4 18.1 104.8 22.5 103 98 1-A 681 02/19/13 EG-3.0 4 18.1 104.8 20.7 101 96 1-A 682 02/19/13 EG-4.0 4 18.1 104.8 20.4 103 98 1-A 683 02/19/13 EG-3.0 4 18.1 104.8 22.1 103 99 1-A 684 02/19/13 EG-4.0 4 18.1 104.8 21.4 104 100 1-A TEST LOCATION: 678 679 680 681 682 683 684 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving Irving, Texas 15' N and 35' E from the SW Corner of Block H, Pad 20 15' N and 35' E from the SW Corner of Block H, Pad 21 15' N and 35' E from the SW Corner of Block H, Pad 16 15' N and 35' E from the SW Corner of Block H, Pad 17 15' N and 35' E from the SW Corner of Block H, Pad 19 DATETEST NO. 15' N and 35' E from the SW Corner of Block H, Pad 18 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER 25' S and 45' W from the NE Corner of Block H, Pad 21 Don Hinton 130127-39C COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Coppell, Texas TECHNICIAN: TESTED FOR:DATE: 02/19/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 685 02/19/13 EG-2.0 4 18.1 104.8 21.7 102 97 1-A 686 02/19/13 EG-3.0 4 18.1 104.8 21.2 104 99 1-A 687 02/19/13 EG-2.0 4 18.1 104.8 22.6 102 97 1-A 688 02/19/13 EG-3.0 4 18.1 104.8 22.0 103 98 1-A 689 02/19/13 EG-2.0 4 18.1 104.8 21.6 103 98 1-A 690 02/19/13 EG-3.0 4 18.1 104.8 20.8 104 99 1-A 691 02/19/13 EG-5.0 4 18.1 104.8 22.0 100 96 1-A TEST LOCATION: 685 686 687 688 689 690 691 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Don Hinton 130127-39D COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Coppell, Texas TECHNICIAN: DATETEST NO. 20' S and 55' W from the NE Corner of Block H, Pad 19 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER 20' S and 55' W from the NE Corner of Block H, Pad 16 20' S and 55' W from the NE Corner of Block H, Pad 21 20' S and 55' W from the NE Corner of Block H, Pad 1 20' S and 55' W from the NE Corner of Block H, Pad 17 20' S and 55' W from the NE Corner of Block H, Pad 18 20' S and 55' W from the NE Corner of Block H, Pad 20 COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving Irving, Texas