Loading...
Westhaven 2-LR130211TESTED FOR:DATE: 02/11/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 465 02/11/13 FG-3.0 6 18.6 102.8 22.5 98 95 1-A 466 02/11/13 FG-2.0 6 18.6 102.8 22.9 102 99 1-A 467 02/11/13 FG-3.0 6 18.6 102.8 23.1 101 98 1-A 468 02/11/13 FG-2.0 4 18.1 104.8 20.7 102 97 1-A 469 02/11/13 FG-3.0 4 18.1 104.8 22.2 101 97 1-A 470 02/11/13 FG-2.0 4 18.1 104.8 22.4 103 98 1-A 471 02/11/13 FG-3.0 4 18.1 104.8 20.6 103 98 1-A TEST LOCATION: 465 466 467 468 469 470 471 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Don Hinton 130127-30 COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Coppell, Texas TECHNICIAN: DATETEST NO. 40' S and 20' W from the NE Corner of Block J, Pad 4 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER 40' S and 20' W from the NE Corner of Block J, Pad 1 40' S and 20' W from the NE Corner of Block J, Pad 6 40' S and 20' W from the NE Corner of Block J, Pad 7 40' S and 20' W from the NE Corner of Block J, Pad 2 40' S and 20' W from the NE Corner of Block J, Pad 3 40' S and 20' W from the NE Corner of Block J, Pad 5 COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving Irving, Texas TESTED FOR:DATE: 02/11/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 472 02/11/13 FG-2.0 4 18.1 104.8 20.2 103 98 1-A 473 02/11/13 FG-3.0 4 18.1 104.8 22.9 102 98 1-A 474 02/11/13 FG-2.0 4 18.1 104.8 22.5 103 98 1-A 475 02/11/13 FG-3.0 4 18.1 104.8 20.8 102 97 1-A 476 02/11/13 FG-3.0 4 18.1 104.8 20.6 103 98 1-A 477 02/11/13 FG-2.0 4 18.1 104.8 21.5 103 98 1-A 478 02/11/13 FG-3.0 4 18.1 104.8 21.4 104 99 1-A TEST LOCATION: 472 473 474 475 476 477 478 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving Irving, Texas 40' S and 20' W from the NE Corner of Block K, Pad 2 40' S and 20' W from the NE Corner of Block K, Pad 3 40' S and 20' W from the NE Corner of Block J, Pad 9 40' S and 20' W from the NE Corner of Block J, Pad 10 40' S and 20' W from the NE Corner of Block K, Pad 1 DATETEST NO. 40' S and 20' W from the NE Corner of Block J, Pad 11 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER 40' S and 20' W from the NE Corner of Block J, Pad 8 Don Hinton 130127-30A COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Coppell, Texas TECHNICIAN: TESTED FOR:DATE: 02/11/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 479 02/11/13 FG-2.0 4 18.1 104.8 22.2 105 100 1-A 480 02/11/13 FG-3.0 4 18.1 104.8 21.9 101 96 1-A 481 02/11/13 FG-2.0 4 18.1 104.8 22.0 102 97 1-A 482 02/11/13 FG-1.0 4 18.1 104.8 21.1 103 99 1-A 483 02/11/13 FG-2.0 4 18.1 104.8 22.0 104 99 1-A 484 02/11/13 FG-1.0 4 18.1 104.8 22.2 101 97 1-A 485 02/11/13 FG-2.0 4 18.1 104.8 21.3 103 98 1-A TEST LOCATION: 479 480 481 482 483 484 485 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Don Hinton 130127-30B COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Coppell, Texas TECHNICIAN: DATETEST NO. 40' S and 20' W from the NE Corner of Block K, Pad 1X IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER 40' S and 20' W from the NE Corner of Block K, Pad 4 45' N and 15' E from the SW Corner of Block J, Pad 2 45' N and 15' E from the SW Corner of Block J, Pad 3 40' S and 20' W from the NE Corner of Block K, Pad 5 40' S and 20' W from the NE Corner of Block K, Pad 6 45' N and 15' E from the SW Corner of Block J, Pad 1 COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving Irving, Texas TESTED FOR:DATE: 02/11/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 486 02/11/13 FG-1.0 4 18.1 104.8 21.6 104 100 1-A 487 02/11/13 FG-2.0 4 18.1 104.8 21.4 105 100 1-A 488 02/11/13 FG-2.0 4 18.1 104.8 20.7 106 101 1-A 489 02/11/13 FG-1.0 5 14.4 111.9 17.1 110 98 1-A 490 02/11/13 FG-1.0 5 14.4 111.9 17.2 111 99 1-A 491 02/11/13 FG-2.0 5 14.4 111.9 16.1 109 97 1-A 492 02/11/13 FG-1.0 5 14.4 111.9 17.1 111 99 1-A TEST LOCATION: 486 487 488 489 490 491 492 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving Irving, Texas 45' N and 15' E from the SW Corner of Block J, Pad 9 45' N and 15' E from the SW Corner of Block J, Pad 10 45' N and 15' E from the SW Corner of Block J, Pad 5 45' N and 15' E from the SW Corner of Block J, Pad 6 45' N and 15' E from the SW Corner of Block J, Pad 8 DATETEST NO. 45' N and 15' E from the SW Corner of Block J, Pad 7 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER 45' N and 15' E from the SW Corner of Block J, Pad 4 Don Hinton 130127-30C COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Coppell, Texas TECHNICIAN: TESTED FOR:DATE: 02/11/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 493 02/11/13 FG-2.0 5 14.4 111.9 15.6 110 99 1-A 494 02/11/13 FG-2.0 5 14.4 111.9 16.1 112 100 1-A 495 02/11/13 FG-1.0 5 14.4 111.9 15.2 112 100 1-A 496 02/11/13 FG-2.0 5 14.4 111.9 16.5 109 97 1-A 497 02/11/13 FG-1.0 5 14.4 111.9 15.3 113 101 1-A 498 02/11/13 FG-2.0 5 14.4 111.9 17.3 111 99 1-A 499 02/11/13 FG-1.0 5 14.4 111.9 17.5 109 98 1-A TEST LOCATION: 493 494 495 496 497 498 499 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Don Hinton 130127-30D COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Coppell, Texas TECHNICIAN: DATETEST NO. 45' N and 15' E from the SW Corner of Block K, Pad 3 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER 45' N and 15' E from the SW Corner of Block J, Pad 11 45' N and 15' E from the SW Corner of Block K, Pad 5 45' N and 15' E from the SW Corner of Block K, Pad 6 45' N and 15' E from the SW Corner of Block K, Pad 1 45' N and 15' E from the SW Corner of Block K, Pad 2 45' N and 15' E from the SW Corner of Block K, Pad 4 COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving Irving, Texas TESTED FOR:DATE: 02/11/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 500 02/11/13 FG-1.0 5 14.4 111.9 18.0 108 97 1-A 501 02/11/13 FG-1.0 5 14.4 111.9 17.6 110 98 1-A 502 02/11/13 FG-1.0 5 14.4 111.9 17.6 109 97 1-A 503 02/11/13 FG-1.0 5 14.4 111.9 15.8 113 101 1-A 504 02/11/13 FG-1.0 5 14.4 111.9 16.3 112 100 1-A 505 02/11/13 FG-1.0 5 14.4 111.9 15.5 111 99 1-A 506 02/11/13 FG-1.0 5 14.4 111.9 16.0 110 98 1-A TEST LOCATION: 500 501 502 503 504 505 506 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving Irving, Texas 35' E and 30' W from the NE Corner of Block J, Pad 5 35' E and 30' W from the NE Corner of Block J, Pad 7 35' E and 30' W from the NE Corner of Block K, Pad 1 35' E and 30' W from the NE Corner of Block K, Pad 3 35' E and 30' W from the NE Corner of Block J, Pad 3 DATETEST NO. 35' E and 30' W from the NE Corner of Block K, Pad 5 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER 35' E and 30' W from the NE Corner of Block J, Pad 11 Don Hinton 130127-30E COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Coppell, Texas TECHNICIAN: