Westhaven 2-LR130205 (2)TESTED FOR:DATE: 02/05/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 322 02/05/13 EG-6.0 2 9.2 124.4 11.7 119 96 1-A 323 02/05/13 EG-5.0 1 11.9 117.9 15.4 113 95 1-A 324 02/05/13 EG-4.0 5 14.4 111.9 16.0 111 99 1-A 325 02/05/13 EG-4.0 5 14.4 111.9 18.0 110 98 1-A 326 02/05/13 EG-5.0 5 14.4 111.9 18.2 109 97 1-A 327 02/05/13 EG-4.0 5 14.4 111.9 17.7 109 98 1-A 328 02/05/13 EG-5.0 5 14.4 111.9 16.8 108 96 1-A TEST LOCATION: 322 323 324 325 326 327 328 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Don Hinton 130127-24 COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Coppell, Texas TECHNICIAN: DATETEST NO. 20' S and 20' E from the NW Corner of Block G, Pad 13 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER 20' S and 20' E from the NW Corner of Block G, Pad 12 20' S and 20' E from the NW Corner of Block G, Pad 15 10' N and 40' W from the SE Corner of Block G, Pad 12 20' S and 20' E from the NW Corner of Block G, Pad 30 20' S and 20' E from the NW Corner of Block G, Pad 29 20' S and 20' E from the NW Corner of Block G, Pad 14 Irving, Texas COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving TESTED FOR:DATE: 02/05/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 329 02/05/13 FG-5.0 5 14.4 111.9 17.6 109 97 1-A 330 02/05/13 FG-4.0 5 14.4 111.9 17.1 111 99 1-A 331 02/05/13 FG-3.0 5 14.4 111.9 16.8 110 98 1-A 332 02/05/13 FG-4.0 1 11.9 117.9 14.2 112 95 1-A 333 02/05/13 FG-3.0 1 11.9 117.9 14.8 115 98 1-A 334 02/05/13 FG-4.0 1 11.9 117.9 13.1 116 98 1-A 335 02/05/13 FG-3.0 1 11.9 117.9 13.1 114 97 1-A TEST LOCATION: 329 330 331 332 333 334 335 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Irving, Texas COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving 15' N and 45' E from the SW Corner of Block G, Pad 31 15' N and 45' E from the SW Corner of Block G, Pad 30 15' N and 45' E from the SW Corner of Block G, Pad 35 15' N and 45' E from the SW Corner of Block G, Pad 34 15' N and 45' E from the SW Corner of Block G, Pad 32 DATETEST NO. 15' N and 45' E from the SW Corner of Block G, Pad 33 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER 15' N and 45' E from the SW Corner of Block G, Pad 36 Don Hinton 130127-24A COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Coppell, Texas TECHNICIAN: TESTED FOR:DATE: 02/05/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 336 02/05/13 FG-3.0 1 11.9 117.9 15.4 113 96 1-A 337 02/05/13 FG-3.0 1 11.9 117.9 14.6 114 97 1-A 338 02/05/13 FG-4.0 1 11.9 117.9 13.2 118 100 1-A 339 02/05/13 FG-3.0 1 11.9 117.9 14.1 117 99 1-A 340 02/05/13 FG-4.0 1 11.9 117.9 15.2 115 97 1-A 341 02/05/13 FG-3.0 1 11.9 117.9 15.5 114 97 1-A 342 02/05/13 FG-4.0 1 11.9 117.9 13.0 116 98 1-A TEST LOCATION: 336 337 338 339 340 341 342 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Don Hinton 130127-24B COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Coppell, Texas TECHNICIAN: DATETEST NO. 30' S and 30' W from the NE Corner of Block G, Pad 15 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER 30' S and 30' W from the NE Corner of Block G, Pad 29 30' S and 30' W from the NE Corner of Block G, Pad 13 30' S and 30' W from the NE Corner of Block G, Pad 12 30' S and 30' W from the NE Corner of Block G, Pad 17 30' S and 30' W from the NE Corner of Block G, Pad 16 30' S and 30' W from the NE Corner of Block G, Pad 14 Irving, Texas COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving