Westhaven 2-LR130119TESTED FOR:DATE: 01/19/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 1 01/19/13 EG-4.0 1 11.9 117.9 12.5 114 97 2-A 2 01/19/13 EG-4.0 1 11.9 117.9 13.2 117 99 2-A 3 01/19/13 EG-4.0 1 11.9 117.9 12.2 115 98 2-A 4 01/19/13 EG-4.0 1 11.9 117.9 12.8 114 97 2-A 5 01/19/13 EG-4.0 1 11.9 117.9 12.4 117 99 2-A 6 01/19/13 EG-6.0 1 11.9 117.9 13.6 114 96 2-A 7 01/19/13 EG-6.0 1 11.9 117.9 12.1 116 98 2-A TEST LOCATION: 1 2 3 4 5 6 7 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving Irving, Texas Wingate Road at Station 2+00 - Paving Station 15' S and 15' E from the NW Corner of Block A, Pad 1 15' S and 25' W from the NE Corner of Block B, Pad 25 20' N and 30' W from the SE Corner of Block B, Pad 27 Huntingdon Street at Station 1+00 - Paving DATETEST NO. 20' S and 30' E from the NW Corner of Block B, Pad 35 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER 20' S and 35' E from the NW Corner of Block B, Pad 1 Don Hinton 130127-5 COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Coppell, Texas TECHNICIAN: TESTED FOR:DATE: 01/19/13 PROJECT:OUR REPORT NO.: TEST DATA: ELEV. DEPTH 8 01/19/13 EG-6.0 1 11.9 117.9 12.8 116 99 1-A 9 01/19/13 EG-3.0 1 11.9 117.9 13.0 117 99 1-A 10 01/19/13 EG-3.0 1 11.9 117.9 13.2 115 98 1-A 11 01/19/13 EG-3.0 1 11.9 117.9 12.2 117 99 1-A 12 01/19/13 EG-3.0 1 11.9 117.9 13.7 115 97 1-A 13 01/19/13 EG-5.0 1 11.9 117.9 12.8 117 99 1-A 14 01/19/13 EG-3.0 1 11.9 117.9 14.2 114 97 1-A TEST LOCATION: 8 9 10 11 12 13 14 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Attef Abushakra, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Don Hinton 130127-5A COMMENT* OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % Westhaven Coppell, Texas TECHNICIAN: DATETEST NO. 15' S and 25' W from the NE Corner of Block B, Pad 26 IN PLACE DRY DENSITY PCF PERCENT COMPACTION SOIL ID NUMBER 25' N and 30' E from the SW Corner of Block A, Pad 2 Wingate Road at Station 2+50 Huntingdon Street at Station 1+50 15' N and 25' W from the SE Corner of Block B, Pad 2 15' S and 15' W from the NE Corner of Block B, Pad 24 20' S and 15' W from the NE Corner of Block B, Pad 36 COMPACTION TESTS REPORT OF FIELD 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 Standard Pacific Homes - Irving Irving, Texas