Loading...
ST0502A-LR150508G1 -GEOTECHNICAL ENGINEERING E I -ENVIRONMENTAL CONSULTING E I -CONSTRUCTION MATERIALS TESTING GEE Consultants, 10046 Monroe Drive - Dallas, Texas 75229 - (214) 352-5433 - Fax (214) 352-6972 REPORT OF CONCRETE MIX OBSERVATION Measured Slump (in.) Report Date: May 8, 2015 Date Concrete Placed: April 29, 2015 Standard 6"xl2" Cylinders Client: City of Coppell Cylinder Cross-sectional Area: 28.27 Square Inches Project: Freeport Pkwy from Ruby Rd. to Sandy Lake Rd. Concrete Report No.: 182 Contractor: CD Builders FPP 702 Project No.: 214-0144 Concrete Supplier and Plant: Argos 110 Location of Placement: Decel Lane North -bound STA 2+00 to 3+20, Bike Trail STA 1+60 to 2+60; STA 12+00 to 15+50 MATERIALS Source / Description SSD Batch Wts. OBSERVATION DATA (Lbs/CuYd) Mix Number: 1273 Time Sample Batched: 7:27 AM Cement: Time Sampled: 8:05 AM Fly Ash: Sample Location: Decel Lane North -bound STA Coarse Aggregate: 2+00 to 3+20, Bike Trail STA Intermediate Aggregate: ASTM C-31, C-39, C-143 1+60 to 2+60; STA 12+00 to Fine Aggregate: 15+50 Admixtures: Truck / Ticket No: 5017 /1605286 1 Temperature: Ambient Range: 53 OF 2 Concrete Range: 66 OF Added Water: 0 Slump Range (inches): 3.5 Weather Conditions: Sunny Time Started: 7:00 AM Time Completed: 3:30 PM Sample Air Content (%): 4.0 Total Cubic Yards Placed: 10 Rarntirarl Ctranrrth 11 the Ion ire 1• '24AA Specimen Number Measured Slump (in.) Age (Days) Date Tested Total Load (Lbs.) Compressive Strength (Lbs./Sq.ln.) Remarks FPP 701 7 516/15 120,140+ 4,250+ FPP 702 28 5/27/15 3.5 FPP 703 28 5/27/15 FPP 704 H Hold Test Methods Utilized Fracture Regular ASTM C-31, C-39, C-143 (Unless Noted Otherwise) Cylinders Made By: CP Remarks and/or Distribution:- None cc: Mr. Rick Odell - City of Coppell via E-mail: ROdell@coppelltx.gov Mr. Michael Garza - City of Coppell, Phone: 972-304-3679; via E-mail: MGarza@coppelltx.gov Mr. Mitch Holmes - Teague, Nall & Perkins, Phone: 432-312-4205; via E-mail: mholmes@tnpinc.com Mr. Francisco Luyando - CD Builders, Inc., Phone: 787-688-8207; via E-mail: fluyando@cdbuilderspr.com GEE Consultants, Inc. TBPE Firm: F-3212 Reviewed by: All letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced without the full approval of GEE Consultants, Inc. The use of our name must receive our prior written approval. Our letters and reports apply only to the sample tested and/or observed and are not necessarily indicative of the quantities of apparently identical or similar products.