RE: Sidewalk and Rail (2)All The original intent was for the rail to be constructed on a thickened trail paving which was to be poured against a ¾” expansion joint at the modular block wall as shown in section J and sheet 87. When I observed the modular block wall as constructed, it appears to me that the top layer or two of modular blocks need to be removed and the edge of the trail section cast on top of the modular block wall. There is a problem in supporting the outside formwork if this needs to done. Following are some ideas that I have had to possibly solve this problem. It appeared to me that the outside edge of the trail paving can be offset enough from the face of the modular blocks to vertically hold the formwork and small angle clips could be attached to the top of the modular blocks to horizontally restrain the bottom of the form. The form would also require supports spanning over the top of the trail at some interval. Form ties could also be inserted in both the outside and pavement side of the trail forms and connected together with wire to provide lateral support. Delvin Black, Ph.D., P.E. Senior Engineer - Structural 1100 Macon Street Fort Worth, Texas 76102 817.480.8968 Mobile 817.336.2813 Fax dblack@tnpinc.com From: Chris Schmitt Sent: Tuesday, October 07, 2014 7:47 AM To: Keith Marvin Cc: Delvin Black; Keith Burkholder Subject: RE: Sidewalk and Rail Keith, We will review and provide comments. Also, I wanted to provide an updated on the gabion walls at the bridge. We have processed the survey data that we captured last week and are currently working on proposed solutions/modifications. I expect to be ready to meet with you later this week to present our plan. I’ll be in touch to schedule a meeting once I have a better feel on timing. Delvin/Keith – Can you assist with the questions below regarding the bridge rail and sidewalks? Thanks Chris Chris Schmitt, P.E. Principal 17304 Preston Road, Suite 1340 Dallas, Texas 75252 214.461.9867 Main 214.988.9913 Direct 903.421.1897 Mobile 214.461.9864 Fax cschmitt@tnpinc.com <mailto:cschmitt@tnpinc.com> From: Keith Marvin [mailto:KMarvin@coppelltx.gov] Sent: Monday, October 06, 2014 7:14 PM To: Chris Schmitt Subject: Fwd: Sidewalk and Rail See bridge rail questions below. I can fill in some information if needed. Thanks. Keith Marvin City of Coppell Begin forwarded message: From: Lance Smith <lsmith@TiseoPaving.com <mailto:lsmith@TiseoPaving.com> > Date: October 6, 2014 at 1:53:26 PM CDT To: <kmarvin@coppelltx.gov <mailto:kmarvin@coppelltx.gov> > Cc: Robert Caudill <rcaudill@TiseoPaving.com <mailto:rcaudill@TiseoPaving.com> >, Royce Carter <rcarter@tiseopaving.com <mailto:rcarter@tiseopaving.com> >, <roycecarter1@yahoo.com <mailto:roycecarter1@yahoo.com> > Subject: Fwd: Sidewalk and Rail Keith, Please see the request for information below from Iowa regarding the rail as discussed onsite. Thanks Lance Sent from my iPad Begin forwarded message: From: Royce Carter <roycecarter1@yahoo.com <mailto:roycecarter1@yahoo.com> > Date: October 6, 2014 at 12:44:44 PM CDT To: Lance <lsmith@Tiseopaving.com <mailto:lsmith@Tiseopaving.com> >, "rcaudill@tiseopaving.com <mailto:rcaudill@tiseopaving.com> " <rcaudill@tiseopaving.com <mailto:rcaudill@tiseopaving.com> > Subject: Fw: Sidewalk and Rail Sent from Yahoo Mail on Android <https://overview.mail.yahoo.com/mobile/?.src=Android> ________________________________ From: Trent Widmer <twidmer@ibctx.com <mailto:twidmer@ibctx.com> >; To: <roycecarter1@yahoo.com <mailto:roycecarter1@yahoo.com> >; Subject: Sidewalk and Rail Sent: Mon, Oct 6, 2014 3:04:55 PM Royce, Iowa bridge requests more information about the rail on the south west end of our project not on the bridge. Please confirm the size and spacing of pilasters. Please confirm the alignment of the rail. Please confirm that the back of the sidewalk will pour against the block retaining wall with a ¾” expansion joint. Trent Widmer Superintendent Iowa Bridge & Culvert, LC 9100 Hwy 380 Cross Roads, TX 76227 214.347.1219 M 940.440.0099 O 940.440.0079 F 143*100509*5 Nextel twidmer@ibctx.com <mailto:twidmer@ibctx.com> The information in this message may be priviledged, confidential, and protected from disclosure. If you are not the intended recipient, employee, or agent responsible for delivery to intended recipient, any dissemination is strictly prohibited. If you have recieved this communication in error, please notify sender immediatley. Opinions, conclusions and other information in this message, unless otherwise stated, that do not relate to Iowa Bridge & Culvert, LC (IBC) official business, are those of the sender and are neither given or endorsed by IBC.