Loading...
DFW Trade JV-LR 990312 (5) · ~i~i~i~i~i~i~i~i~i~i~i~i~i~i~i~i~i~i~i~i~i..'..~i~i~!~i~i~i~:.~ P.O. Box 223571 DALLAS, TEXAS 75222-3571 CONCRETE CYLINDER COMPRESSIVE STRENGTH REPORT TO: INDUSTRIAL DEV. INTERNATIONAL PROJECT: DFW TRADE CENTER 5420 LBJ FREEWAY, SUITE 1275 BUILDING H DALLAS, TX 75240 TETCO NO.: 3126 DATE: 03/12/99 TECHNICIAN: J. TIPTON REPORT NO.: 399458-RM 499022-PL CONCRETE FOR: PAVING AT WEST WALL PARKING & DRIVE AREAS FOR BUILDING H CYLINDER I SLUMP AGE DATE DATE TOTAL I COMPRESSIVE MARKI CONCRETE MIX INFORMATION INCHES DAYS CAST TESTED LOAD, LBSI STRENGTH, PSI IDI 920 PIONEER PLANT #27 4" 7 03/05/99 03/12/99 84,000 2,970 IDI 921 MIX #9339 4" 28 03/05/99 04/02/99 112,500 3,980 IDI 922 4" 28 03/05/99 04/02/99 110,000 3,890 FINE AGG. SOURCE: 28 DAY STRENGTH REQUIREMENT: 3500 PSI COARSE AGG. SOURCE: BRAND OF CEMENT: ADDITIONAL INFORMATION IF MADE BY TETCO: TIME MADE: 6:30 AM UNIT WEIGHT: NA TRUCK NO.: 923 CONCRETE TEMP.: 60 F WATER ADDED TO TRUCK: NONE TICKET NO: 170031 LT WIND AIR CONTENT: 4.8% ACCUMULATED YARDS: 160 CY WEATHER: CLEAR 50 REMARKS: NOTES: (1.) COMPRESSIVE STRENGTHS DETERMINED IN ACCORDANCE WITH ASTM C39 (2.) CROSS-SECTIONAL AREA, DIAMETER & LENGTH ARE STANDARD UNLESS OTHERWISE NOTED (3.) PORTIONS OF THE INFORMATION CONTAINED IN THIS REPORT HAVE BEEN FURNISHED BY OTHERS (4) CYLINDERS CURED IN LABORATORY IN ACCORDANCE WITH ASTM C31 UNLESS OTHERWISE NOTED (5.} UNBONDED CAPS UTILIZED IN ACCORDANCE WITH ASTM C1231 UNLESS OTHERWISE NOTED (6.) SAMPLES TAKEN IN ACCORDANCE WITH ASTM C172 WHERE PRACTICABLE. COPIES TO: 1-CLIENT ATT: KEN KUESEL 1- KAJIMA CONST. SERV. TRINITY ENGINEERING TESTING CORP. 1-COMPASS BANK 1-MacGREGOR ASSOC. ARCHITECTS 1-POTTER CONCRETE CO. l-PIONEER CONCRETE ' 1-CITY OF COPPELL Roy R. Grant, P.E. The results shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested and/or inspected. 45 They are not intended to be indicative of qualities of apparently identical products. The use o~' our name must receive prior written approval