DFW Trade JV-LR 990401 TRINITY ENGINEERING TESTING CORPORATION
P.O. Box 223571 DALLAS, TEXAS 75222-3571 972-870-0808
TO: INDUSTRIAL DEV INTERNATIONAL PROJECT: DFW TRADE CENTER
5420 LBJ FRWY, SUITE 1275 BUILDING H
DALLAS, TX 75240 TETCO NO.: 3126
DATE: 4/1/99
REPORT NO.: 499132
REPORT OF FLOOR FLATNESS AND FLOOR LEVELNESS
THE FOLLOWING AREA OF BUILDING H WAS TESTED FOR FLOOR FLATNESS AND LEVELNESS
ON 4-1-99 BY J. TIPTON USING A TYPE II GAUGE IN GENERAL ACCORDANCE WITH ASTM E 1155:
B, 7; D, 7; B, 14; D, 14
THE RESULTS ARE AS FOLLOWS: MINIMUM LOCAL VALUE
REQUIREMENTS
FF = 64 (62.1 - 65.8) 22 MINIMUM
FL = 50 (48.2- 51.3) 16 MINIMUM
THE OVERALL RESULTS FOR BUILDING H ARE AS FOLLOWS:
SPECIFIED OVERALL VALUE
REQUIREMENTS
FF = 58 32 MINIMUM
FL = 45 25 MINIMUM
COPIES TO: 1-CLIENT, ATT: KEN KUESEL
1-KAJIMA CONST
1-COMPASS BANK ~.-, TRINITY ENGINEERING ,TESTING CORP.
1-POTTER CONCRETE CO.
1-PIONEER CONCRETE
1-CITY OF GRAPEVINE ~ -
1-CITY OF COPPELL Bi p I, Jr~,YP.E.
The results shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested and/or inspected.
They are not intended '~g b¢ indicative of auafittes of az~oarentlv identical oroducts. The use of our name must receive prior written ac~nroval