DFW Trade JV-LR 990420 (4) P.O. Box 223571 DALLAS, TEXAS 75222-3571
CONCRETE CYLINDER COMPRESSIVE STRENGTH REPORT
TO: INDUSTRIAL DEV. INTERNATIONAL PROJECT: DFW TRADE CENTER
5420 LBJ FREEWAY, SUITE 1275 BUILDING H
DALLAS, TX 75240 TETCO NO.: 3126
DATE: 04/20/99
TECHNICIAN: J. Tipton REPORT NO.: 499577-WG
CONCRETE FOR: Floor slab at lane #2, 140 feet West of line #7 and 50 feet South of line #D.
CYLINDER I SLUMP I AGE I DATE I DATE I TOTAL I COMPRESSIVE
MARK CONCRETE MIX INFORMATION INCHES DAYS CAST TESTED LOAD, LBS STRENGTH, PSI
IDI 1081 PIONEER PLANT #27 4 1/2" 7 04/13/99 04/20/99 122,000 4,310
IDI 1082 MIX #9349 4 1/2" 28 04/13/99 05/11/99
IDI 1083 4 1/2" 28 04/13/99 05/11/99
FINE AGG. SOURCE: 28 DAY STRENGTH REQUIREMENT: 4000 PSI
COARSE AGG. SOURCE: BRAND OF CEMENT:
ADDITIONAL INFORMATION IF MADE BY TETCO:
TIME MADE: 7:15 AM UNIT WEIGHT: NA TRUCK NO.: 1803
CONCRETE TEMP.: 68 F WATER ADDED TO TRUCK: NONE TICKET NO: 171489
LTWINDS
AIR CONTENT: 3.0°,/o ACCUMULATED YARDS: 260 WEATHER: PTCLDY 62
REMARKS:
NOTES: (1 .) COMPRESSIVE STRENGTHS DETERMINED IN ACCORDANCE WITH ASTM C3g (2.) CROSS-SECTIONAL AREA, DIAMETER & LENGTH ARE STANDARD
UNLESS OTHERWISE NOTED (3.) PORTIONS OF THE INFORMATION CONTAINED IN THIS REPORT HAVE BEEN FURNISHED BY OTHERS (4.) CYLINDERS CURED
IN LABORATORY IN ACCORDANCE WITH ASTM C31 UNLESS OTHERWISE NOTED (5.) UNBONDED CAPS UTILIZED IN ACCORDANCE WiTH ASTM C1231 UNLESS
OTHERWISE NOTED (6) SAMPLES TAKEN IN ACCORDANCE WITH ASTM C172 WHERE PRACTICABLE.
COPIES TO: 1-CLIENT
ATT: KEN KUESEL
1- KAJIMA CONST. SERV. TRINITY ENGINEERING TESTING CORP.
1-COMPASS BANK
1-MacGREGOR ASSOC. ARCHITECTS
1-PIONEER CONCRETE · ! ·
1-CITY OF GRAPEVINE~-~1'~1.
1-CITY OF COPPELL Roy R. Grant, P.E.
The results shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested and/or inspected.
421 They are not intended to be indicative of qualities of apparently identical products. The use of our name must receive prior wnl~ten approval.