DFW Trade JV-LR 990420 (6) P.O. Box 223571 DALLAS, TEXAS 75222-3571 CONCRETE CYLINDER COMPRESSIVE STRENGTH REPORT TO: INDUSTRIAL DEV. INTERNATIONAL PROJECT: DFW TRADE CENTER 5420 LBJ FREEWAY, SUITE 1275 BUILDING H DALLAS, TX 75240 TETCO NO.: 3126 DATE: 04/20/99 TECHNICIAN: J. Tipton REPORT NO,: 499575-WG CONCRETE FOR: Floor slab at lane #2, 60 feet South of line #D and 15 feet West of line #7. MARK CONCRETE MIX INFORMATION INCHES DAYS CAST TESTED LOAD, LBS STRENGTH, PSI IDI 1076 PIONEER PLANT #27 4 3/4" 7 04/13/99 04/20/99 112,000 3,960 IDI 1077 MIX #9349 4 3/4" 28 04/13/99 05/11/99 IDI 1078 4 3/4" 28 04/13/99 05/11/99 FINE AGG. SOURCE: 28 DAY STRENGTH REQUIREMENT: 4000 PS1 COARSE AGG. SOURCE: BRAND OF CEMENT: ADDITIONAL INFORMATION IF MADE BY TETCO: TIME MADE: 4;50 AM UNIT WEIGHT: NA TRUCK NO,: 923 CONCRETE TEMP.: 67 F WATER ADDED TO TRUCK: 5 GALS TICKET NO: 171471 WINDY AIR CONTENT: 3.2% ACCUMULATED YARDS: 50 WEATHER: PTCLDY 61 REMARKS: NOTES: (1.) COMPRESSIVE STRENGTHS DETERMINED IN ACCORDANCE WITH ASTM C39 (2.) CROSS-SECTIONAL AREA, DIAMETER & LENGTH ARE STANDARD UNLESS OTHERWISE NOTED (3.) PORTIONS OF THE INFORMATION CONTAINED IN THIS REPORT HAVE BEEN FURNISHED BY OTHERS (4.) CYLINDERS CURED tN LABORATORY IN ACCORDANCE WITH ASTM C31 UNLESS OTHERWISE NOTED (5.) UNBONDED CAPS UTILIZED IN ACCORDANCE WITH ASTM C1231 UNLESS OTHERWISE NOTED (6.) SAMPLES TAKEN IN ACCORDANCE WITH ASTM C172 WHERE PRACTICABLE. COPIES TO: 1-CLIENT ATT: KEN KUESEL 1- KAJIMA CONST. SERV. TRINITY ENGINEERING TESTING CORP. 1-COMPASS BANK 1-MacGREGOR ASSOC. ARCHITECTS 1-PIONEER CONCRETE , · 1-CITY OF GRAPEVINE ThL[ / 1-CITY OF COPPELL~,.r~ Roy R. Grant, P.E. The resulta shown on this report are for the exclusive use of the client for whom they were obtained and apply only to the samples tested and/or inspected, 421 They are not intended to be indicative of quaii~Jes of apparently identical products, The use of our name must receive pdor written approval.