Loading...
PA0101-LR010717CONCRETE COMPRESSIVE STRENGTH TEST 8901 Carpenter Fn~'., Suite #100 Report Number: 94011093.0022 Dallas, Texas 75247 Service Date: July 6, 2001 (214) 63O-lOlO Client: City of Coppell - Parks & Recreation Re July 17, 2001 Attn: Brad Reid t: Andrew Brown Park East 732 DeForest Moore Road Coppell TX 75019 Coppell, Texas Pr .~ct Number: 94011093 Material Information Informatio~ Specified Strength: 3000 psi @ 28 Days Sam Date Cast: July 6, 2001 Technician: Eric Garcia Batch Time: 7:54am Plant: 31 Weather Conditions: Partly cloudy, sunny Supplier: TXI Accumulative Yards: 70 Truck No: 737 Ticket No: 2931097 Placement Method: Pump Mix I.D. No.: 8272 Sample Locations: See placement location Placement Location: Paving on plaza area between softball fields on E side of park (See attached sketch) Field Test Data Test Result Specification Test Method Slump, inches: 4.00 3-5 ASTM C-143 Air Content, %: 3-6 Concrete Temperature, o F: 89 ASTM C-1064 Ambient Temperature, o F: 81 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (.sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 07/13/2001 7 72,820 2,570 1 2 6.00 28.27 07/13/2001 7 77,950 2,760 Ave rage 2,670 1 3 08/03/2001 28 1 4 08/03/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. ASTM C-31, C-39, C-172, C-1231 01~I 1-zo Technician: Eric Ga re ia Report Distribution: (1) city of coppell - Parks & Recreation Reviewed by: (1) TLB Construction v ~'~r~. Cleveland, P.E. (1) City of Coppell - Constr. Insp. Senior Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1