PA0101-LR010712CONCRETE COMPRESSIVE STRENGTH TEST ~.div,,~,o¢~-.~,. 8901 Carpenter FnNy., Suite #100 Report Number: 94011093.0019 Dallas, Texas 75247 Service Date: June 29, 2001 (214) 63O-lOlO Client: City of Coppell - Parks & Recreation Repo~ July 12, 2001 Attn: Brad Reid Pro ,ndrew Brown Park Ea 732 DeForest Moore Road Coppell TX 75019 Coppell, Texas Pr ct Number: 94011~ Material Information Sa Specified Strength: 3000 psi @ 28 Days Sample ~m Date Cast: June 29, 2001 Technician: Anthony Mercier Batch Time: 5:59am Plant: 41 Weather Conditions: Supplier: TXI Accumulative Yards: 120 Truck No: 462 Ticket No: 2927232 Placement Method: Pump Mix I.D. No.: 8272 Sample Locations: 10' N of baseball field light #5 Placement Location: Andrew Trail PAR 4 Field Test Data Test Result Specification Test Method Slump, inches: 4.00 3-5 ASTM C-143 Air Content, %: 3.8 N/A ASTM C-172 Concrete Temperature, o F: 77 ASTM C-39 Ambient Temperature, o F: 84 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 I 6.00 28.27 07/06/2001 7 97,300 3,440 1 2 6.00 28.27 07/06/2001 7 97,780 3,460 Average 3,450 I 3 07/27/2001 28 I 4 07/27/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Anthony Mercie~ (1) City of Coppell - Parks & Recreation Reviewed by: (1) TLB Construction (1) City of Coppell - Constr. Insp. Eric J. Cleveland, P.E. Senior Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials, o,~,_,,,,,~,.,~,~, Page 1 of 1 'CONCRETE COMPRESSIVE STRENGTH TEST Report Num~: ~ 1093.0024 89Ol Carpenter FnNy.. Suite #100 p~'~'~~~Date ! J uly'~3, 2_00'~ Dallas, Texas 75247 (214) 630-1010 Servic~l~e:' JulyS12, 2001 Clien~t,f'City of Coppell I Parks & Recreation Re ~ ~1' Attn: Brad Re~ : j~ 732 DeForester [, Pr Mate~l Infor/nation Salt~le Info~'iation Specified S~'~ngth: 3000 psi @ 28 Days Sam~8:05am Date Cast: July 12, 2001 Technician: Sammy Cardona Batch Time: 7:43am Plant: 41 Weather Conditions:Clear, sunny Supplier: TXI Accumulative Yards: 80 Truck No: 58 Ticket No: 1921042 Placement Method: Pump Mix I.D. No.: 8272 Sample Locations: 15' E, 20' N of plaza area Placement Location: Plaza area Field Test Data Test Result Specification Test Method Slump, inches: 5.25 3-5 ASTM C-143 Air Content, %: Concrete Temperature,© F: 90 ASTM C-1064 Ambient Temperature, o F: 85 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Lond Rtr~p(~th No. ID (inches) (sq. inches) Tested (days) ~['l~s) 1 1 6.00 28.27 07/19/2001 7 76,810 2,720 1 2 6.00 28.27 07/19/2001 7 75,480 Average 2,700 1 3 08/09/2001 28 1 4 08/09/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. 0~ / ASTM C-31, C-39, C-172, C-1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 o~<Lw~o,.-~..~.~ ,'CONCRETE COMPRESSIVE STRENGTH TEST 8901 Carpenter Rwy., Suite #100 Report Number: 94011093.0024 Da,as, Texas 75247 Service Date: July 12, 2001 (214) 63O-lOlO Client: City of Coppell - Parks & Recreation Report Date: July 23, 2001 Attn: Brad Reid Project: Andrew Brown Park East 732 DeForest Moore Road Coppell TX 75019 Coppell, Texas Project Number: 94011093 Material Information Sample Information Specified Strength: 3000 psi @ 28 Days Sample Time: 8:55am Date Cast:July 12, 2001 Technician: Sammy Cardona Batch Time: 8:21 am Plant: 41 Weather Conditions: Clear, sunny Supplier: TXI Accumulative Yards: 130 Truck No: 111 Ticket No: 1921049 Placement Method: Pump Mix I.D. No.: 8272 Sample Locations: 20' W, 15' N of plaza area Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 5.00 3-5 ASTM C-143 Air Content, %: Concrete Temperature,o F: 92 ASTM C-1064 Ambient Temperature, o F: 88 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 1 6.00 28.27 07/19/2001 7 101,510 3,590 2 2 6.00 28.27 07/19/2001 7 102,620 3,§30 Average 3,610 2 3 08/09/2001 28 2 4 08/09/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. ASTM O-31, C-39, C-172, C-1231 Technician: Sammy Cardona Report Distribution: ~~g, Inc. (1) City of Coppell - Parks & Recreation (1) TLB Construction Reviewed by: (1) City of Coppell - Constr. Insp. Eric J. Cleveland, P.E. Senior Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2