PA0101-LR010629 07/19/2001 14:30 8174618836 SIERRA CONTRACTORS PAGE 02
' ' C ECTION_ COMPRESSION TEST REPORT
Client:
tiller S~erra Construction '7 Work Order Number: 4894
PrOJect: 0~026 Andy Brown Community Pa~ Report Number: 01-026.117
Strength (psi): ~ oe ..... , !Date ef Placement: 6/29/2001
SJuml:){in.): ,5
Slml31ed by: T. Jackson
Air Co, tent(%): NA 'WeaU~er: Warm & Partly Ctoudy
Concrete TemlXF): ;Not to exceed 100' ,SuPPlier/Mix: Redf Mix
FIELD DATA SE~ # 1
Ti=ket #~ 141348 i~-ime Betc, hed: 9~00:00 AM Time $Smpled: 1030:00 AM
Slump (in.): 5 iAir Content: NA Unit We~ht (pcf): NA
Conc:r~te Temp(F): 87' lair Temp (F): 80' Yardage: 1
Location/Remarks: Wesl side Grade Beam
SET CYL. DATE AGE MAX LOAD iS'FRENGTH~ TEsT CYLINDER NOTES
NO. NO. TESTED (days) . (Ib~) (psi) RESULT , SOURCE
I 1 7/6/2001 7 101000 3570
1 2 712712001 28
1 3 7/27/2001 28
1 4 6/23/2001 56
NORMAL CYLINDER 61ZE: 5X12, AREA:28.27~q. in. UNLEI~S FRACTURE UNLE$8 INDICATED OTHERWISE IN NOTES TEST RESL.'LTS COMPLY
WITH PROJECT SI~E:.CIICICATIONS UNLE~I~ INDICATED ELD ?EOTS BY SOILTECN ENGINI~RINO AND TESTING, INC. ARE PER
APPLiCAbLE ASTM STANDAFIDS: C13~1, C143, Cq ?2 C231 CYLINDERS BY SOILTE. CH EN(~INEERING AND TESTING, INC. ARE PER A~TM C31, TESTEE)