---- ? -- Concrete Compression Test Report
Client: The City of Coppell Report Distribution: (1) The City of Coppell
Project: Freeport Parkway Pavement
Repair
TMI Report No.: DC01-066-013
Report Date: 07/25/2001
Specifications Test Data
Strength 4000 psi @ 28 Days Placement Date 07/11/2001
Slump 5 in max Sampled By Walter V. Kirby
Air Content 3 % rain 6 % max Weather Clear / Sunny
Concrete Temperature n/a Supplier/Mix Hanson/9636
Ambient Temperature n/a Air Content Method ASTM C-231-B
~--~ . - ~ =:_-~ ----Z ~-"~_~'-=~t~ .......... ,, ::: 'q",
Ticket Number: 818967 Time Batched: 11:55 AM Time Sampled: 12:45 PM
Slump: 5 in Air Content: 7.0 %* Unit Weight: n/a
Concrete Temperature: 96° F Ambient Temperature: 99° F Yardage (c.y.): 10 of 30
Placement Location: North bound outside lane of Freeport Parkway, 200' North of Wrangler, leaveouts
Sample Location: North bound outside lane of Freeport Parkway, 200' North of Wrangler, leaveouts
An asterisk (*) appears next to field data which does NOT meet specifications.
Load Area Str~ Fracture
Set# Cyl~der Test Date . (l~.Xforce) (sq.in.) ~'a~) [ I Type
1 07110101 07/18/2001 90030 28.27 ~' 3180 ~unbonded
cap
1 07110102 07/18/2001 101280 28.27 J~x 3580 ~r'unbonded cap
I 07110103 07/2512001 107230 28.27 ~1 3790 ~' unbonded cap
1 07110104 07/25/2001 107780 28.27 ~ 3810 ,~ unbonded cap
I 07110105 08/08/2001
I 07110106 0810812001
Normal cylinder size: 6"x 12"
Field and laboratory tests by TMI are per applicable ASTM Standards: C31,039, C138, C143, C172, C1064, and C617 or C1231.
xx '
(,,x/ / Sr. Vice President
The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproducfion of
this report, or any part therein, is stdctly prohibited without the express written consent of TMI.
Pa§¢ I of I