Loading...
ST0004-LR010720 ~ GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS  DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW 11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax:(972) 488-8080 ---- ~ - Concrete Compression Test Report Client: The City of Coppell Report Distribution: (1) The City of Coppell Project: Freeport Parkway Pavement Repair TMI Report No.: DC01-066-009 Report Date: 07/20/2001 Specifications Test Data Strength 4000 psi @ 28 Days Placement Date 07/06/2001 Slump 5 in max Sampled By Chikezie Kalu Air Content 3 % min 6 % max Weather Clear Concrete Temperature n/a Supplier/Mix Hanson/9636 Ambient Temperature n/a Air Content Method ASTM C-231-B Ticket Number: 866426 Time Batched: n/a Time Sampled: 2:30 PM Slump: 3.75 in Air Content: 5.4 % Unit Weight: n/a Concrete Temperature: 94° F Ambient Temperature: 96° F Yardage (c.y.): 30 of 100 Placement Location: Paving Sample Location: NE comer of intersection of Freeport Pkwy. & Airline Dr. Cylinder Age. Max Load Area Strength Fracture Set # # Test Date (days/ (lbs. force) (sq.in.) (psi} Type 1 07060101 07/13/2001 7 102320 28.27 3620 unbonded cap 1 07060102 07/13/2001 7 97840 28.27 3460 unbonded cap 1 07060103 07/20/2001 14 116940 28.27 4140 unbonded cap 1 07060104 07/20/2001 14 118300 28.27 4180 unbonded cap 1 07060105 08/03/2001 28 1 07060106 08/03/2001 28 Normal cylinder size: 6"x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C61J or C1231. / ,~J~' R~-MAR, INC. ~ sr~ ~si~n~ ' The results presented in this repo~ pe~ain only to the specific items tested. This mpo~ was produced for the exclusive use of the client. Any repr~uction of this repo~, or any paA therein, is strictly prohibited without the express wdtten consent of TMI. Page I o~1