ST0004-LR010719 ~ GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS
DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW
11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax.'(972) 488-8080
-=- ? -' Concrete Compression Test Report
Client: The City of Coppell Report Distribution: (1) The City of Coppell
Project: Freeport Parkway Pavement
Repair
TMI Report No.: DC01-066-017
Report Date: 07/19/2001
Specifications Test Data
Strength 4000 psi @ 28 Days Placement Date 07/12/2001
Slump 5 in max Sampled By Walter V. Kirby
Air Content 3 % min 6 % max Weather Calm / Clear
Concrete Temperature n/a Supplier/Mix Hanson/9636
Ambient Temperature n/a Air Content Method ASTM C-231-B
Ticket Number: 799452 Time Batched: 2:00 PM Time Sampled: 2:30 PM
Slump: 5 in Air Content: 6.0 % Unit Weight: n/a
Concrete Temperature: 99° F Ambient Temperature: 102° F Yardage (c.y.):
Placement Location: North bound lane (inside) at NE corner of Freeport & Airline Drive
Sample Location: North bound lane (inside) at NE corner of Freeport & Airline Drive
Set # Cyl~der Age Max Load Area Strength Fracture
Test Date (days) (lbs. force) (sq.in.) (psi} Type
1 07120101 07/19/2001 7 109780 28.27 3880 unbonded cap
1 07120102 07/19/2001 7 105150 28.27 3720 unbonded cap
1 07120103 07/26/2001 14
1 07120104 07/26/2001 14
1 07120105 08/09/2001 28
1 07120106 08/09/2001 28
Normal cylinder size: 6" x 12"
Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231.
TERRA-MAR, INC.
The results presented in this report pertain only to the specific items tested, lhis report was produced for the exclusive use of the client. Any reproduction of
this report, or any part therein, is strictly prohibited without the express wdtten consent of TMI.
Page I of I