ST0004-LR010719 (2) ~ GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS
DALLAS FORT WORTH HOUSTON AUSTIN L ONGVIEW
11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488-8800 fax:(972) 488-8080
---- ~ - Concrete Compression Test Report
Client: The City of Coppell Report Distribution: (1) The City of Coppell
Project: Freeport Parkway Pavement
Repair
TMI Report No.: DC01-066-013
Report Date: 07/19/2001
Specifications Test Data
Strength 4000 psi @ 28 Days Placement Date 07/11/2001
Slump 5 in max Sampled By Walter V. Kirby
Air Content 3 % min 6 % max Weather Clear / Sunny
Concrete Temperature n/a Supplier/Mix Hanson/9636
Ambient Temperature n/a Air Content Method ASTM C-231-B
Ticket Number: 818967 Time Batched: 11:55 AM Time Sampled: 12:45 PM
Slump: 5 in Air Content: 7.0 %* Unit Weight: n/a
Concrete Temperature: 96° F Ambient Temperature: 99° F Yardage (c.y.): 10 of 30
Placement Location: North bound outside lane of Freeport Parkway, 200' North of Wrangler, leaveouts
Sample Location: North bound outside lane of Freeport Parkway, 200' North of Wrangler, leaveouts
An asterisk (*) appears next to field data which does NOT meet specifications.
Set # Cyl~der Age. Max Load Area Strength Fracture
Test Date (days) (lbs. force) (sq.in.) (psi} Type
1 07110101 07/18/2001 7 90030 28.27 3180 unbonded cap
1 07110102 07/18/2001 7 101280 28.27 3580 unbonded cap
1 07110103 07/25/2001 14
I 07110104 07/25/2001 14
I 07110105 08/08/2001 28
1 07110106 08/08/2001 28
Normal cylinder size: 6"x 12"
Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231.
I 8GOTT RL PETTIT ~
·
TERRA-MAR, INC. ~
' 8r.~c~ Pmsid~nt '
lbo results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of
this report, or any part therein, is strictly prohibited without the express written consent of TMI.
Page 1 of I