Denton Tap L2R BA-LR010702FUGRO SOUTH, INC. 2880 virgo Lane; Dallas. Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Preston Engineering Report Date: July 2, 2001 PROJECT: Everybody Fits, Coppell, Texas Project No.: 0701-2035 SAMPLE DATE: June 21, 2001 CONTRACTOR: Preston Engineering TICKET NO.: 98316 CONCRETE SUPPLIER: Nelson Brothers AMBIENT TEMP. (°F): 75 PLANT/TRUCK: CONCRETE TEMP. (°F) (ASTM C-'1064).' 88 MIX ID NUMBER: TIME BATCHED: 6:45 am AIR (%) (ASTM C-231): 4.6 TIME SAMPLED: 7:30 am WATER ADDED (gal): WEATHER CONDITION: Slightly cloudy SLUMP (in.) (ASTM C-143): 4 LOCATION OF PLACEMENT: Paving, sidewalk CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) EFC 44 7 06/28/01 108200 3830 4000/28 days EFC 45 28 07/19/01 EFC 46 28 07/19/01 EFC 47 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C-31 Testing ASTM C-143. T¥;)esof [~] ~ ~ D Curing: Methods: ASTM C-39 Fracture: A B C D REMARKS: Technician: Jered Sims FUGRO SOUTH INC. Reviewed By: SMH/rm Distribution: Preston Engineering - Timothy D. McMahon, P.E. City of Coppel, - Lee Stone City of Coppell - Larry Davis..----'"-'- --