January 18, 2001
City of Coppell
P.O. Box 478
Coppell, Texas 7501
PAGE
Attn: Michael Martin
Re: Paving at Dickey's BBQ
Dear Mr. Martin:
Cooper Industries is requesting a variance to the Subdivision Ordinance requiring 6" of lime stabilized
subgrade underneath the proposed paving submitted by Doyle Engineering.
Attached please find a copy of the variance letter used for the construction of the original paving at the
restaurant. In the letter, the geotechnical engineer, Maxim Technologies, Inc., gave options for the Area
Paving and Fire Lane concrete. As in the original request, Cooper Industries would like to use the
following designs:
1. 5" - 4000 psi Concrete at Area Paving
2. 6" - 4000 psi Concrete at Fire Lanes
Please call with any questions or comments.
Sincerely:
Coop Industries, Inc.
ene Cooper
cc:
Dave Adams - Doyle Engineering
81
972-245-7960 i 614 South Broadway - Suite 100 - Carrollton, Texas 75006 972-245-7970 Fax
81/18/2881
17:35
9?2245?9?0
972~4579
COOPER
~1~1~1
I U 9~, -~55~1~53
PAGE
P. O2/OE
TI Gl'IN O I.O ~.IE $ IN¢
October 1, 1999
City Of Coppell
Engineering Department
Attention: Mr. ~-_flce Martin
P.O, Box 475
Coppell, Texas 750! 9-4409
Re:
Dickey's Barbeque Re~aurant - 801 S. Demon Tap Road
Paving Ordinance Variance
Dear: Mr. Martin
At the request of Mr. O~me Cooper of Cooper Builders, we have reviewed our geote¢Imical
report (report number 9906819, dated May 21, 1999) to verify hi~ proposed options for site
pavement are in accord with our original geotechnical report. The options requested are listed
below:
AREA PAVI2qG
5" of 3,000 psi concrete over 6" lime stabilized subgrade
5" of 4,000 psi concrete over 6" smiled and recompaeted sub~'ade to 95% std. proctor
6" of 3,000 psi concrete over 6" scarified and recompacted subgrade to 95% std. proctor
FIRE LANES
6" of 3,000 psi concrete over 6" lime stabilized subgrade
6" of 4,000 psi concrete over 6" scarified and recompacted subgrade to 95% std, proctor
7" of 3,000 psi concrete over 6" scarified and ~ecompaeted subgrade to 95% std. proctor
The general contractor (Cooper Builders) has requested to be allowed to use 4,000 psi concrete
for both Area Paving and the Fire Lane.
Upon review of our geotechnical report, we have concluded that ali the options listed above meet
or exceed the recommendations stated in the original geotechnical report (9906819).
Please feb fi'ce to contact us with any questions at (214) 920-! 843.
Sincerely:
MAXIM TEC]~iNOLOGIES, 12qC.
T. Neill Lawrence, Ir., ]~.I.T.
Geoteehnical Engineering Services