Loading...
CRDC 14-01 PN1501283 w N Q M WE i L.� 15' T.U. ELECTRIC ESMT. I p O I +o �. d PROPOSED POWER POLE I I PROPOSED THREE EXISTING POWER • ' I WA Y PRECAST I POLE TO REMAIN 7— '1A I ° —� MANHOLE. INSTALL II • PER DCS -5 DETAIL • I I� SHEET 8 PROPOSED 4-6" ® / I II I CONDUIT. INSTALL PER DDS -4 UG DETAIL I � I II i L SHEETS 2, 3, 7, 8 & 9 FOR TRENCH, COVER, w MINIMUM BEND RADIUS & INSTALLATION / w I ■ f: I I REQUIREMENTS INGRESS, EGRESS & J PARKING ESMT. /LW VOL. 89121, PG. 2082 / ILL - I LL LOT 3 BLOCK A I I I I - -. I/ � O / ® PROPOSED 4-6" / C / CONDUIT BY BORING. INSTALL PER DDS -4 UG DETAIL SHEETS 2, 3, 7, 8 / I I �, I PROPOSED UG Il■I CONDUITS I & 9 FOR TRENCH, COVER,I 4 PVC I I „ I I /--EXISTING POWER MINIMUM BEND RADIUS' I - TIMEWARNE INSTALLATION REQUIREME TS I I CABLE / PROPOSED 15' I UTILITY ESMT. I I r -A I I l 10' TELEPHONE ESMT. I I I / VOL- 71001 PG. 1944 I F / PROPOSED 4-6"E8 / CONDUIT. INSTALL PER DQ.S-4 UG DETAIL SHEETS i I I I I / 2, 3, 7, 8 & 9 & DCS -5 I /� asl� - I I DETATZ SHEET 11 FOR / ♦ 1 I / TRENCH, _ COVL-P, MINIMUM I / I I / I IPROP SED UG CONDUITS o I / z BEND RADIUS & / �♦ I �" P -TIMEWARNER CABL EXISTING UG INSTALLA TION REQUIREMENTS I b FEEDER ♦ / " P -CISD DATA CABLE I / PROPOSED UG FEEDER • I I I PROPOSED TO CONNECT TO / I/ I I I E IFOUR WAY I / SWI TCH GEAR PROPOSED UG CONDUITS. l I ♦♦ % STING POWER POLE BE REMOVED PRECAST - T I EXISTING POWER 4" PVC- VERIZON l • I MANHOLE POLE TO REMAIN 4" PVC TIMEWARNER CABLE R FER TO DDS -4 UG I INSTALL PER I I I 000 X I D TAIL SHEET 1 DCS -5 2" PVC-CISD DATA CABLE = I I' I SHEET 8 DETAIL I - a � Iglass. r ---least -------------- - ■■■■■- I -- - - - - - - - - -- ���■��it, i�■��■■■■ +�■� In I *A- Its'slit — — I I 30' FIRE LANE, UE & ■ ■ ■ MUTUAL ACCESS ESMT. s I PROPOSED 6-6" ■ ■ ■ ■ VOL. 89121, PG. 2082 I I I CONDUITS WITH I I PROPOSED DUCT BANK BY -�� I X BORING. INSTALL ■' I I PER DDS -4 UG I I ■ DETAIL SHEETS 2DCS - DETAIL I I �I ISHEET 11 FOR 'ROPOSED 7X7.5' °`" PROPOSED �� I I I TRENCH 00 VER o 'MH -11 SWITCH GEAR PROPOSED 4-6- ® FOUR WAY + 'AD. REFER TO DDS -4 CONDUIT. INSTALL PER PRECAST 1 I MINIMUM BEND + MANHOLE I OREQUI RADIUS & I JG DETAIL SHEET 39 DDS -4 UG DETAIL SHEETS INSTALL PER I I I STALLATION 'OR DESIGN 2, 3, 7, 8 & 9 & DCS -5 3 D.�-5 DETAIL I I REMENTS I ?EQUIREMEN IS - DETAIL SHEET 11 FOR TRENCH, COVER, MINIMUM SHEET 7 I 1 I I I EXISTING UG ELEC. T0� y BEND RADIUS & I II I PROPOSED UGC DUI S I INSTALLA TION CONNECT TO SWITCH 4" PVC- TIMEWARNER ABLE GEAR REQUIREMENTS ! r I I. 2" PVC- CISD DATA CA LE PROPOSED I POWER POLE I I ti I. I I I I I no. revision by date scale horiz vert date Jan 2015 POLE TO BE REMO VED REFER TO DDS -4 UG DETAIL SHEET 1 is EXISTING POWER F 7— POLE TO BE �7EMTVEb REFER TO DDS -4 UG PROPOSED _ . DETAIL SHEET 1 ` POWER POLE r— I J - PROPOSED 5' UTILITY ESMT. I PROPOSED 2-6" PROPOSED 101 CONDUITS BY BORING. INSTALL UTILITY ESMT. PER DDS -4 UG DETAIL SHEETS I 2, 3, 7, 8 & 9 FOR TRENCH, COVER, MINIMUM BEND RADIUS & PROPOSED 2-6" INSTALLATION REQUIREMENTS — ® I CONDUITS BY BORING. INSTALL PER DDS -4 UG DETAIL SHEETS 2,,3� 7, 8 & 9 FOR TRENCH, COVER, MINIM BEND RADIUS _& INSTALLATION REQUIREf ENTS EXISTING POWER I POLE -TO REMAIN 60' BUILDING SET BACK LINE I teag ue nail & perkins 17304 Preston Road, Suite 1340 Dallas, Texas 75252 214.461.9867 ph 214.461.9864 fx TBPE Registration No. F-230 L www.tnpinc.com I 24' UTILITY ESMT. EXISTING POWER POLE TO REMAIN This document is for interim review and is not intended for construction, bidding or permit purposes. 30% SUBMITTAL Chris Schmitt , P.E. Date: 11-11-14 Tx. Reg. # 91 150 F ONCOR CONDUITS/ DUCT BANK 4" PVC CONDUIT FOR TIME WARNER CABLE ------------- 4" PVC CONDUIT FOR VERIZON _ 2" PVC CONDUIT FOR CITY DATA CABLE 2" PVC CONDUIT FOR CISD DATA CABLE to 01 GRAPHIC SCALE 20 0 10 20 40 GRAPHIC SCALE: 1" = 20' NOTES AND INSTRUCTIONS FOR INSTALLA TION OF CONDUITS: 1. TRENCH ALIGNMENT SHALL BE AS STRAIGHT AS CONDITIONS PERMIT. ANY DEVIATIONS FROM PLANNED ALIGNMENT SHALL HAVE PRIOR APPROVAL BY THE PROJECT ENGINEER/INSPECTOR. ALL TRENCH CUTS SHALL BE IN ACCORDANCE WITH EXISTING SAFETY REGULA TIONS IN EFFECT. 2 TRENCH BOTTOM SHOULD BE UNDISTURBED, TAMPED, OR RELA TIVEL Y SMOOTH EARTH. WHERE EXCA VA TION IS IN ROCK, THE CONDUIT SHOULD BE LAID ON A LAYER OF CLEAN BACKFILL. J. ALL BACKFILL SHOULD BE FREE OF DEBRIS OR OTHER MA TERIAL THAT MAY DAMAGE THE CONDUIT SYSTEM OR CAUSE SETTLING THE MATERIAL SHOULD FILL THE VOIDS AROUND THE CONDUIT TO PREVENT HOT SPOTS & SETTLING. 4. BACKFILL SHOULD BE ADEQUA TEL Y COMPACTED. BACKFILL NOT UNDER PA VEMENT SHOULD BE COMPACTED TO THE DENSI TY OF THE SURROUNDING UNDISTURBED SOIL. BACKFILL UNDER PA VEMENT SHOULD BE COMPACTED TO NOT LESS THAN 959 OF THE DENSITY OF UNDISTURBED SOIL AS DETERMINED BY ASTM D-698. City of Coppell, Texas Construction Plans for SANDY LAKE ROAD/ DENTON TAP ROAD STREET SCAPE, ILLUMINATION & INTERSECTION IMPROVEMENTS UTILITY PLAN SOUTH DENTON TAP tnpproject � CPL14141 sheet— I SYMBOL LEGEND O GAS MANHOLE CATV SERVICE BOX ❑E ELECTRIC PEDESTAL © GAS METER © CATV PEDESTAL O ELECTRIC MANHOLE ® GAS VALVE EM FIBER OPTIC HAND HOLE EM ELECTRIC METER o GAS VENT PIPE ® FIBER OPTIC MANHOLE ELECTRIC PULLBOX -6- FIRE HYDRANT FIBER OPTIC PEDESTAL ® ELECTRIC TRANSMISSION TOWER O WATER MANHOLE O TELEPHONE MANHOLE POWER POLE ❑W WATER METER TELEPHONE PEDESTAL E GUY ANCHOR ® WATER VALVE © STORM MANHOLE ILLUMINATION POLE O WATER VENT PIPE STORM SEWER INLET °(> PEDESTRIAN SIGNAL POLE ® WATER VAULT O WASTEWATER CLEANOUT IID TRAFFIC CONTROL HAND BOX MARKER POST O WASTEWATER MANHOLE UTILITY LEGEND Line Utility Company CATV1 Cable Television Time Warner Cable E1 Electric Oncor E2 Electric City of Coppell E3 Electric Private F01 Fiber Optic Verizon F02 Fiber Optic Zayo F03 Fiber Optic Coppell I.S.D. F04 Fiber Optic Time Warner Cable F05 Fiber Optic AT&T -T F06 Fiber Optic City of Coppell G1 Gas Atmos OHE1 Overhead Electric Oncor OHCATVI Overhead CATV Time Warner Cable OHF01 Overhead Fiber Optic Verizon OHF02 Overhead Fiber Optic Time Warner Cable OHF03 Overhead Fiber Optic Coppell I.S.D. OHT1 Overhead Telephone Verizon STM1 Storm Sewer City of Coppell T1 Telephone Verizon W1 Water City of Coppell W2 Water City of Dallas WW1 Waste Water City of Coppell QUALITY LEVEL LEGEND — WW1 — QUALITY LEVEL B — — — — WW1 (C) — — — — QUALITY LEVEL C — — — — WW1 (D) — — — — QUALITY LEVEL D ONCOR CONDUITS/ DUCT BANK 4" PVC CONDUIT FOR TIME WARNER CABLE ------------- 4" PVC CONDUIT FOR VERIZON _ 2" PVC CONDUIT FOR CITY DATA CABLE 2" PVC CONDUIT FOR CISD DATA CABLE to 01 GRAPHIC SCALE 20 0 10 20 40 GRAPHIC SCALE: 1" = 20' NOTES AND INSTRUCTIONS FOR INSTALLA TION OF CONDUITS: 1. TRENCH ALIGNMENT SHALL BE AS STRAIGHT AS CONDITIONS PERMIT. ANY DEVIATIONS FROM PLANNED ALIGNMENT SHALL HAVE PRIOR APPROVAL BY THE PROJECT ENGINEER/INSPECTOR. ALL TRENCH CUTS SHALL BE IN ACCORDANCE WITH EXISTING SAFETY REGULA TIONS IN EFFECT. 2 TRENCH BOTTOM SHOULD BE UNDISTURBED, TAMPED, OR RELA TIVEL Y SMOOTH EARTH. WHERE EXCA VA TION IS IN ROCK, THE CONDUIT SHOULD BE LAID ON A LAYER OF CLEAN BACKFILL. J. ALL BACKFILL SHOULD BE FREE OF DEBRIS OR OTHER MA TERIAL THAT MAY DAMAGE THE CONDUIT SYSTEM OR CAUSE SETTLING THE MATERIAL SHOULD FILL THE VOIDS AROUND THE CONDUIT TO PREVENT HOT SPOTS & SETTLING. 4. BACKFILL SHOULD BE ADEQUA TEL Y COMPACTED. BACKFILL NOT UNDER PA VEMENT SHOULD BE COMPACTED TO THE DENSI TY OF THE SURROUNDING UNDISTURBED SOIL. BACKFILL UNDER PA VEMENT SHOULD BE COMPACTED TO NOT LESS THAN 959 OF THE DENSITY OF UNDISTURBED SOIL AS DETERMINED BY ASTM D-698. City of Coppell, Texas Construction Plans for SANDY LAKE ROAD/ DENTON TAP ROAD STREET SCAPE, ILLUMINATION & INTERSECTION IMPROVEMENTS UTILITY PLAN SOUTH DENTON TAP tnpproject � CPL14141 sheet— I