CRDC 14-01 PN150128 (2)3 LU UJ ¢ C0 E Q 00-0 < I ¢ Ln m O x GV O 0� U 3 Z -O i w �o X m x I w x 0 clv L � x U CQ U J a J EXISTING POWER POLE TO REMAIN 1 DENTON TAP ROAD PROPOSED POWER POLE R5+00 7�0 — Ld aLLI 1WS3 Z A111181SIA I Iwl, 1WS3 �4-1VM341S / CINV 1.1nun ,OZ I O E I• I I� I_ ~ (STING POWER w. r POLE TO REMAIN Li o I I ' _ I a 3NVI 32113/ 1WS3 ~ I SS303V ,9Z H '1WS3 AiIT A M QI L o �I a - no. revision 84+00 r rs r -- ® PROPOSED 2-6" CONDUIT BY BORING. INSTALL PER DDS -4 UG DETAIL SHEETS 2, 3, 7 & 8 FOR TRENCH, COVER & INSTALLATION REQUIREMENTS EXISTING POWER POLE TO BE REMO VED REFER TO DDS -4 UG DETAIL SHEET 1 . 1 took _ ... j r VI is ■.r--- ii M . i i i 0 M 0 M 0 M 0 0 : ::. M M M M M M: . ME ME ME ME ME ME ME ME ME E M E M E M E o i i i i i i i i i i i i i i . E� No ME No :::: o ME No ►' �� �. ------ ------------ -- ---E 82+00 PROPOSED UG CONDUITS 4" PVC -TIME WARNER CABLE - 2" PVC -CITY DATA CABLE scale horiz vert PROPOSED 15' z UTILITY ESMT. a 0 0 •, • - .. 1b I IN T- T ONCOR CONDUITS/ DUCT BANK 4" PVC CONDUIT FOR TIME WARNER CABLE 4" PVC CONDUIT FOR VERIZON 2" PVC CONDUIT FOR CITY DATA CABLE 2" PVC CONDUIT FOR CISD DATA CABLE date Jan 2015 Ir teague nail & perkins 17304 Preston Road, Suite 1340 tn Dallas, Texas 75252 214.461.9867 ph 214.461.9864 fx TBPE Registration No. F-230 www.tnpinc.com J PROPOSED 8'X8' SIZED FOR 750 DF LOOP FEED TRANSFORMER PAD. REFER TO DDS -4 UG DETAIL SHEET, 20 FOR DESIGN REQUIREMENTS 81+00 YS EXISTING POWER POLE TO BE REI�O VED. REFER TO DDS -4 UG DETAIL SHEET 1 PROPOSED 10' UTILITY ESMT. I \ I SHEET 50 FOR DESIGN I 1 REQUIREMEN TS \` PROPOSED 18'X18' TRANSFORMER \ PAD ESMT � I - Id PROPOSED 1 SIDE GUARD POST. REFER TO DDS -4 UG DETAIL G�: F GRAPHIC SCALE 20 0 10 20 40 GRAPHIC SCALE: 1" = 20' NOTES AND INSTRUCTIONS FOR INSTALLATION OF CONDUITS.- 1. TRENCH ALIGNMENT SHALL BE AS STRAIGHT AS CONDITIONS PERMIT. ANY DEWA TIONS FROM PLANNED ALIGNMENT SHALL HA VE PRIOR APPROVAL BY THE PROJECT ENGINEER/INSPECTOR. ALL TRENCH CUTS SHALL BE IN ACCORDANCE WITH EXISTING SAFETY REGULATIONS IN EFFECT 2. TRENCH BOTTOM SHOULD BE UNDISTURBED, TAMPED, OR RELA TIVEL Y SMOOTH EARTH. WHERE EXCA VA TION IS IN ROCK, THE CONDUIT SHOULD BE LAID ON A LAYER OF CLEAN BACKFILL. J. ALL BACKFILL SHOULD BE FREE OF DEBRIS OR OTHER MA TERIAL THA T MAY DAMAGE THE CONDUIT SYSTEM OR CAUSE SETTLING. THE MATERIAL SHOULD FILL THE VOIDS AROUND THE CONDUIT TO PREVENT HOT SPOTS & SETTLING. 4. BACKFILL SHOULD BE ADEQUA TEL Y COMPACTED. BACKFILL NOT UNDER PA VEMENT SHOULD BE COMPACTED TO THE DENSI TY OF THE SURROUNDING UNDISTURBED SOIL. BACKFILL UNDER PAVEMENT SHOULD BE COMPACTED TO NOT LESS THAN 959 OF THE DENSITY OF UNDISTURBED SOIL AS DETERMINED BY ASTM D-698. This document is for interim review and is not intended for construction, bidding or permit purposes. 30% SUBMITTAL Chris Schmitt , P.E. Date: 11-11-14 Tx. Reg. # 91 150 City of Coppell, Texas Construction Plans for SANDY LAKE ROAD/ DENTON TAP ROAD STREET SCAPE, ILLUMINATION & INTERSECTION IMPROVEMENTS UTILITY PLAN NORTH DENTON TAP tnpproject � CPL14141 sheet� 3 --�t ;-T� I I PROPOSED ce CONNECTION TO SERVICE ❑E ELECTRIC PEDESTAL LINES I I I I � I I ~ CATV PEDESTAL II LL ® LE Z IC z FIBER OPTIC HAND HOLE EM ELECTRIC METER City of Coppell, Texas Construction Plans for SANDY LAKE ROAD/ DENTON TAP ROAD STREET SCAPE, ILLUMINATION & INTERSECTION IMPROVEMENTS UTILITY PLAN NORTH DENTON TAP tnpproject � CPL14141 sheet� 3 SYMBOL LEGEND O ce CATV SERVICE BOX ❑E ELECTRIC PEDESTAL © GAS METER © CATV PEDESTAL O ELECTRIC MANHOLE ® GAS VALVE ® FIBER OPTIC HAND HOLE EM ELECTRIC METER o GAS VENT PIPE ® FIBER OPTIC MANHOLE ❑R ELECTRIC PULLBOX –b– FIRE HYDRANT FIBER OPTIC PEDESTAL ® ELECTRIC TRANSMISSION TOWER O WATER MANHOLE O TELEPHONE MANHOLE POWER POLE 0 WATER METER Q TELEPHONE PEDESTAL E GUY ANCHOR ® WATER VALVE ® STORM MANHOLE ILLUMINATION POLE O WATER VENT PIPE STORM SEWER INLET c(> PEDESTRIAN SIGNAL POLE ® WATER VAULT O WASTEWATER CLEANOUT IID TRAFFIC CONTROL HAND BOX �{ City of Coppell, Texas Construction Plans for SANDY LAKE ROAD/ DENTON TAP ROAD STREET SCAPE, ILLUMINATION & INTERSECTION IMPROVEMENTS UTILITY PLAN NORTH DENTON TAP tnpproject � CPL14141 sheet� 3 SYMBOL LEGEND O GAS MANHOLE CATV SERVICE BOX ❑E ELECTRIC PEDESTAL © GAS METER © CATV PEDESTAL O ELECTRIC MANHOLE ® GAS VALVE ® FIBER OPTIC HAND HOLE EM ELECTRIC METER o GAS VENT PIPE ® FIBER OPTIC MANHOLE ❑R ELECTRIC PULLBOX –b– FIRE HYDRANT FIBER OPTIC PEDESTAL ® ELECTRIC TRANSMISSION TOWER O WATER MANHOLE O TELEPHONE MANHOLE POWER POLE 0 WATER METER Q TELEPHONE PEDESTAL E GUY ANCHOR ® WATER VALVE ® STORM MANHOLE ILLUMINATION POLE O WATER VENT PIPE STORM SEWER INLET c(> PEDESTRIAN SIGNAL POLE ® WATER VAULT O WASTEWATER CLEANOUT IID TRAFFIC CONTROL HAND BOX �{ MARKER POST O WASTEWATER MANHOLE UTILITY LEGEND Line Utility Company CATV1 Cable Television Time Warner Cable E1 Electric Oncor E2 Electric City of Coppell E3 Electric Private F01 Fiber Optic Verizon F02 Fiber Optic Zayo F03 Fiber Optic Coppell I.S.D. F04 Fiber Optic Time Warner Cable F05 Fiber Optic AT&T–T F06 Fiber Optic City of Coppell G1 Gas Atmos OHE1 Overhead Electric Oncor OHCATVI Overhead CATV Time Warner Cable OHFO1 Overhead Fiber Optic Verizon OHF02 Overhead Fiber Optic Time Warner Cable OHF03 Overhead Fiber Optic Coppell I.S.D. OHT1 Overhead Telephone Verizon STM1 Storm Sewer City of Coppell T1 Telephone Verizon W1 Water City of Coppell W2 Water City of Dallas WW1 Waste Water City of Coppell QUALITY LEVEL LEGEND — WW1 — QUALITY LEVEL B — — — — WW1 (C) — — — — QUALITY LEVEL C — — — — WW1 (D) — — — — QUALITY LEVEL D City of Coppell, Texas Construction Plans for SANDY LAKE ROAD/ DENTON TAP ROAD STREET SCAPE, ILLUMINATION & INTERSECTION IMPROVEMENTS UTILITY PLAN NORTH DENTON TAP tnpproject � CPL14141 sheet� 3