Eastbury Manor-CS 980226 (3)DEVELOPMENT REVIEW COMMITTEE
ENGINEERING COMMENTS
ITEM: .pl}-167. Eastburv Manor. Preliminary Plat. to allow the development of
a 27-1ot residential subdivision on a I[689 acre tract of land located at the
northwest corner of Lodge and Sandy Lake Roads, at the request of
Ryland Group, Ina
DRC DATE: February 26, 1998 and March 5, 1998
CONTACT: Mike Martin, P.E., Assistant City Engineer 004-3679)
COMMENT STATUS: ~'PRELIMINARY ~ P~ggI$~D
1. The Sanitary Sewer Line for Lots 1-6, Block 1 should be located in the front instead of the
back.
2. Indicate on the site plan the 5' right-of-way dedication for Lodge Road.
3. All utility and drainage easements for City utilities must be a minimum of 20' wide as per the
Subdivision Ordinance.
As per the Subdivision Ordinance the street alignments must have a minimum 125' offset,
therefore the proposed Edinburgh Drive needs to be a minimum 125' offset from Cedar Crest
Drive.
5. Need to eliminate the street connection to Sandy Lake Road.
6. Please explain why alleys cannot be provided for the lots in Block 2. Also, it appears Lot 7,
Block 1 can take alley access offthe existing alley to the north.
7. Show correct visibility easement at all street intersections. This will impact Landscaping
Plan.
8. Show a 5' wide sidewalk along Sandy Lake.
9. Do not plant trees in right-of-way of Sandy Lake that will need to be removed for
construction. This impacts a minimum of five trees.