Loading...
Office Park- CS150629T H E C 1 T Y O F COFFEL ' L o June 29, 2015 Nancy Cline, P.E. Area Engineer Denton County Area Office 2624 W. Prairie Denton, TX 76201 RE: Coppell/ 121 Office Parr Dear Mrs. Cline, The City of Coppell is in receipt of a driveway permit request located adjacent to the service road of State Highway 121 in Coppell, Denton County. This project includes construction of a single driveway intersections to the frontage road of SH 121. The City of Coppell Engineering Department has reviewed the permit prepared by Savant Group and approves the location of the proposed driveway intersection. However, the City of Coppell requests a deceleration lane to accompany this driveway. If you have any questions, please feel free to contact me at your convenience. Sincerely, George Marshall, P.E. Civil Engineer Office Phone: (972) 304-3562 gmarshall@coppelltx.gov cc: Andrew Beckman Josh Smith A FAMILY COMMUNITY FOR A LIFETIME 255 PARKWAY * P.O. BOX 9478 * COPPELL TX 75019 * TEL 972/462 0022 * WWW.COPPELLTX.GOV Permit to Construct Access Driveway Facilities on Highway Right of Way oepsmmr orrr .sportauon Form 1058 (Rev. 05/13) Page 1 of 2 PERMIT NUMBER: TxDOT ENTER PERMIT NUMBER HERE GPS* ROADWAY REQUESTOR LATITUDE, LONGITUDE HWY NAME I SH 121 32°59'24.31"N, 97° 02.77" FORTxDOT'S USE CONTROL 4 -DIGIT NAME Andrew Beckman SECTION 2 -DIGIT EX. 01 MAILING ADDRESS 433 E. Las Colinas Blvd Suite 1100 CITY, STATE, ZIP Irving, TX 75039 PHONE NUMBER 214-637-4300 *GLOBAL POSITIONING SYSTEM COORDINATES AT INTERSECTION OF DRIVEWAY CENTERLINE WITH ABUTTING ROADWAY The Texas Department of Transportation, hereinafter called the State, hereby authorizes Glacier Commercial Realty, LP hereinafter called the Permittee, to ® construct / ❑ reconstruct a office park (residential, convenience store, retail mall, farm, etc.) access driveway on the highway right of way abutting highway number SH 121 in Denton County, located on the westbound frontage road approximately 2,500 ft from the west edge of pavement of Denton Tap Rd USE ADDRIONAL SHEETS AS NEEDED Subject to the Access Driveway Policy described on page 2 and the following: 1. The undersigned hereby agrees to comply with the terms and conditions set forth in this permit for construction and maintenance of an access driveway on the state highway right of way. 2. Design of facilities shall be as follows and/or as shown on sketch on page 2 and is subject to conditions stated below: See sketch on page 9 of accompanying traffic study showing proposed location of driveway. Deceleration lane will be constructed as per requirement of the City of Coppell. Driveway and deceleration lane construction plans forthcoming. All construction of materials shall be subject to inspection and approval by the State. 3. Maintenance of facilities constructed hereunder shall be the responsibility of the Permittee, and the State reserves the right to require any changes, maintenance or repairs as may be necessary to provide protection of life or property on or adjacent to the highway. Changes in design will be made only with approval of the State. 4. The Permittee shall hold harmless the State and its duly appointed agents and employees against any action for personal injury or property damage sustained by reason of the exercise of this permit. 5. Except for regulatory and guide signs at county roads and city streets, the Permittee shall not erect any sign on or extending over any portion of the highway right of way, and vehicle service fixtures such as fuel pumps, vendor stands, or tanks and shall be located at least 12 feet from the right of way line to ensure that any vehicle services from these fixtures will be off the highway right of way. 6. The State reserves the right to require a new access driveway permit in the event of a material change in land use or change in driveway traffic volume or vehicle types. 7. This permit will become null and void if the above -referenced driveway facilities are not constructed within six (6) months from the issuance date of this permit. 8. The Permittee will contact the State's representative telephone, ( ) , at least twenty-four (24) hours prior to beginning the work authorized by this permit. 9. The requesting Permittee will be provided instructions on the appeal process if this permit request is denied by the State. Date of Issuance State Authorized Representative The undersigned hereby agrees to comply with the terms and conditions set forth in this permit for construction and maintenance of an access driveway on the highway right of way. Date: Signed: (Property owner or owner's representative) Form 1058 (Rev. 05/13) Page 2 of 2 Access Driveway Policy Title 43 Texas Administrative Code (Transportation), Chapter 11 (Design), Subchapter C (Access Connections To State Highways) and the "Access Management Manual' establish policy for the granting of access and the design, materials, and construction of driveways connecting to state highways. All driveway facilities must follow this policy. TxDOT Driveway Permit Request Contact For a local contact for your TxDOT Driveway Permit Request visit: http://www.txdot.gov/inside-txdot/district html. You can click on the section of the map closest to your location to find the local TOOT office. You can also click on the drop down box below the map to find the district for your county. Sketch of Installation (Use additional sheets as needed) I RANSPORFAF ION 2435 N. CI N I RAI FXPI(FSSWAY. SUI I 1 750 3808 ARBORIAWN DR. 1'.N(;INFFRS & VIANNCRS MCI IARMON. 1 FXAS 75080 FOR[ WOR[FI, TEXAS 76109 OFFICE (214) 468-8200 oFFICF: (817) 886-4740 FAX: (214) 468-8266 FAX: (817) 886-4739 WWW.SAVAN WROUI'INC.COM SAVANT G ROUP Memorandum To: Andrew Beckman, Glacier Commercial Realty, LP From: Josh Smith, P.E., PTOE Brian Kellogg, M.Sc. Date: 4/14/15 Re: Coppell Office Park Traffic Study Savant Group, Inc. (SGI) was retained by Glacier Commercial Realty, LP to perform a traffic study for the Coppell Office Park, located near the intersection of Denton Tap Road and the SH 121 (Sam Rayburn Tollway) frontage road. The site location is shown in Figure 1, and the draft site plan is shown in Figure 2. This memo includes a summary of the site visit and data collection performed, the estimates of the project site's trip generation and distribution, and weaving and driveway analysis. 44k U) = (D O 70 0 O r) n o 44k U) = (D O 70 0 O r) n Glacier Commercial Realty, LP Coppell Office Park Traffic Study Coppell, Texas Data Collection 24-hour automated traffic recorder counts were taken for Wednesday, January 21, 2015. The raw count data can be found in Appendix A. The counts were collected in 15 -minute increments at the following locations: • Existing TriCounty Plaza driveway • SH 121 southbound (westbound) frontage road, west of the TriCounty Plaza driveway • SH 121 southbound (westbound) exit ramp to SH 121 Business northbound • SH 121 southbound (westbound) entrance ramp from Denton Tap Road The AM and PM peak hours were determined based on the maximum hourly volumes of the southbound SH 121 frontage road and the exit ramp adjacent to the proposed site. The AM peak hour was found to be from 8:00 to 9:00 AM, and the PM peak hour was found to be from 5:15 to 6:15 PM. The collected volumes are shown in Figure 3. A site visit was made during a weekday AM peak hour, in which traffic operations and roadway geometric information were noted. Driver behavior was noted by driving along the likely routes toward the site and tracking floating car speed and traffic congestion. In general it was noted that, although the posted speed along the frontage road adjacent to the proposed site is 55 mph, heavy congestion along the SH 121 southbound mainlanes and entrance ramp from Denton Tap Road — as well as the proposed site's proximity to Denton Tap Road — resulted in a lower observed speed than the posted speed limit. When coming from Denton Tap Road toward the project site, most vehicles appeared to accelerate to around 50 mph by the time they reach the site. Site Traffic Generation and Distribution The proposed office park development will include two buildings of 23,500 square feet, for a total of 47,000 square feet. The ITE Trip Generation Manual, 9th Edition was used to estimate daily and peak SAVANT ] GK0UP Page 3 Glacier Commercial Realty, LP Coppell Office Park Traffic Study Coppell, Texas hour trips generated by the proposed site. Table 1 shows the AM and PM peak hour trip generation for the proposed site. The full trip generation worksheet can be found in Appendix B. Tahle 1- Pronosed Site Trio Generation Trips entering the proposed site will either come from the SH 121 southbound off -ramp near the site, or the southbound SH 121 frontage road via the traffic signal at Denton Tap Road. Trips exiting the site could either use the southbound onramp onto the SH 121 mainlanes or continue along the frontage road, which turns back toward Denton Tap Road and Round Grove Road (FM 3040). Census tract population information was used in conjunction with Maptitude software to estimate the percentage of vehicles using these different routes to access the site for a nominal assumed commuting radius of 15 miles. The assumed catchment areas for inbound trips to the site, along with their respective census populations, is shown in Figure 4. The trip distribution estimates are shown in Table 2. Figure 4 - Assumed Catchment Areas for Inbound Trips JV I „r -Denton 1 • Little Elm _ •C«inch Frisco ' rH=aDENTON N .�•" LOLL ..;t • Highland Village • The Colony 732,033 (using frontage road) •Lewisv le _ t Flower Moundt �Pli 830,255 s (using SB/WB offramp) Site Location ,Addison eoppell -Carrollton • Richardso v.r •Soulhlake '• eller i•ry •Grapevine I Farmers Branch •Colleyville .Watauga :..,r • Bed/«d .•, mversly Park iARRANT Euless DALLAS North Richl Hillsil ppp Irving Haltom city" o�LLAS SAVANT�j GROUP Page AM Peak Trips PM Peak Trips Land use ITE Code Size In Out In Out General Office Building 710 47,000 sq. ft. 92 13 22 1 109 Trips entering the proposed site will either come from the SH 121 southbound off -ramp near the site, or the southbound SH 121 frontage road via the traffic signal at Denton Tap Road. Trips exiting the site could either use the southbound onramp onto the SH 121 mainlanes or continue along the frontage road, which turns back toward Denton Tap Road and Round Grove Road (FM 3040). Census tract population information was used in conjunction with Maptitude software to estimate the percentage of vehicles using these different routes to access the site for a nominal assumed commuting radius of 15 miles. The assumed catchment areas for inbound trips to the site, along with their respective census populations, is shown in Figure 4. The trip distribution estimates are shown in Table 2. Figure 4 - Assumed Catchment Areas for Inbound Trips JV I „r -Denton 1 • Little Elm _ •C«inch Frisco ' rH=aDENTON N .�•" LOLL ..;t • Highland Village • The Colony 732,033 (using frontage road) •Lewisv le _ t Flower Moundt �Pli 830,255 s (using SB/WB offramp) Site Location ,Addison eoppell -Carrollton • Richardso v.r •Soulhlake '• eller i•ry •Grapevine I Farmers Branch •Colleyville .Watauga :..,r • Bed/«d .•, mversly Park iARRANT Euless DALLAS North Richl Hillsil ppp Irving Haltom city" o�LLAS SAVANT�j GROUP Page Glacier Commercial Realty, LP Coppell Office Park Traffic Study Coppell, Texas Table 2 - Proposed Inbound Site Trip Distribution Roadway Inbound Using SH 121 off -ramp 45% Using SH 121 southbound 55% (NW -bound) frontage road Applying the projected trips from the project site and estimated trip distribution, the expected peak hour volumes after build -out of the site are shown in Figure 5. Driveway Placement Analysis The proposed site is expected to be accessed through an existing shared -access connection to the TriCounty Plaza development to the east of the site. In addition, a new driveway is proposed immediately west of the proposed site, based on coordination with the adjacent property owner for a shared -access connection. The location of the new driveway needs to meet TOOT standards for spacing between the upstream SH 121 exit ramp and the driveway, as well as between the proposed driveway and the downstream existing driveway and on-ramp. Evaluation of the potential need for and design requirements for auxiliary lanes are also discussed in this section. Exit Ramp to Drivewav SDacin TxDOT's Roadway Design Manual was used to determine the recommended spacing between the upstream SH 121 off -ramp and the proposed new driveway. Figure 6 is a reproduction of Figure 3- 13 in the TOOT Roadway Design Manual, and illustrates the spacing needed between an off -ramp and driveway. It should be noted that the defined "intersection of travel lanes" is shown to start 50 feet after the convergence of the lane striping of the exit ramp and frontage road. Table 3 is a reproduction of Table 3-16, which shows the desirable spacing between exit ramps and driveways as a function of frontage road volume, driveway volume, and number of weaving lanes. With a PM peak frontage road volume of 1308 vehicles/hour (vph) (=491+817), a driveway volume of 11 vph, and three weaving lanes, at least 460 feet of space (not including the 50 feet needed starting at the SAVANT ] GP,0UP Page 5 Glacier Commercial Realty, LP Coppell Office Park Traffic Study Coppell, Texas convergence of the ramp and frontage road striping) would be needed between the off -ramp and driveway. The 460 -foot spacing is also applicable for the AM peak hour volumes shown in Figure 5. •Igure b-Itecommenaea Access control at txlt intersec+ion of Away Surface ��t Frontcoe Road Control of access line 150 ft Yorroble [15 m: junction wltn montage Itoaa Intersectran of Travel Lanea WeOvinq LOneS I —III ' Spticiug (ft [inD t � - � � 4 � - Yariable 3 4 2500 a 460 [140] 460 [140] 560 [170] -- 250 > ar 460 [140] Access decried wtlere 0ractical ,_ a C3 vA Q For exit romp to driveway, side street, or cross street spocings, See cable 3-16. ( Wnen the 250 ft [75 In] separation distance cannot be obtained, consrderotion should be given to channeltzation methods that would restrict access to driveways within the 250 ft 175 ml separctron distance. Source: TOOT Table 3 - Desirable Spacing between Exit Ramps and Driveways, Side Streets, or Cross Streets Total Volume (Frig rd +Ramp) 6 -Ph) DriVeW.IV or Side Street olume (tFli) Spticiug (ft [inD -- - \hunber of Weaving Limes -- - 2 3 4 2500 '-250 460 [140] 460 [140] 560 [170] -- 250 520 [160] 460 [140] 560 [170] -- > 750 790 [240] 460 [140] 560 [170] -- = 1000 1000 [300] 460 [140] 560 [170] -, 2500 '.-_250 920 [280] 460 [140] 560 [170] 950 [290] 460 [140] 560 [170] -- > 750 1000 [300] 600 [180] 690 [210] -- > 1000 1000 [300] 1000 [300] 1000 [300] Source: TOOT S /WA N`I'p) (; Iu)U I' Page 6 Glacier Commercial Realty, LP Coppell Office Park Traffic Study Coppell, Texas Figure 7 shows a reproduction of Figure 3-14 in TxDOT's Roadway Design Manual, which shows the recommended distance between a driveway/side street and a downstream entrance ramp along a frontage road. TxDOT recommends 300 feet for such a distance. Considering the needed space between the proposed driveway and existing driveway near the entrance ramp, this driveway to entrance ramp distance was not a controlling factor in determining possible driveway locations. Figure 7 — Recommended Access Control at Entrance Ramp Junction with Frontage Road Intersection Intersection of Roodway Surfoce of Trovel lorws® P� int f III Front(wr Rood !i III— -- Control « 200 ft '000 of access r5 [w � ) O l30 �1 line Cr QHIrNp1N a�lrmi• WOW. TL a t m� )00 1t (W 01 O9@iraXllN OCC�M OKff 110 L •- O0 AOONM dInled dnr/ prootlool 0 When the 100 ft (30 m) separation distonce cannot be obtoined, considerotion should be given to chonneIIzat�on metnods thot would restrict occess to driveways within the 100 ft (30 m) seperation distance. NOTE: THIS SHEET IS NOT INTENDED 10 WN CNANIELIZATION, STRIPING.OR PAVI%KNT WAKING DETAILS. NETER TO INE TEXAS W11CO. RECOMMENDED ACCESS CONTROL AT ENTRANCE RAMP JUNCTION WITH FRONTAGE ROAD Source. TOOT SAVANT 6j GROUP Page 7 Glacier Commercial Realty, LP Coppell Office Park Traffic Study Coppell, Texas Driveway to Driveway Spacing For a posted speed of 55 mph, the TxDOT Access Management Manual recommends at least 425 feet of space between driveways on a one-way frontage road, as shown in Table 4, which is a reproduction of Table 2-1 in the TxDOT Access Management Manual. This space is measured between the two nearest edges of each driveway. Table 4 - Frontage Road Connection Spacing Criteria 'Uniunum Connection Spacing Criteria for Frontage Roads (l)(r) hiinimunr Connection Spacing (feet) Posted Speed (mph) One -Way Frontage Roads Two-Uay Frontage Roads <:30 200 200 35 250 300 40 305 360 45 360 435 50 425 510 (1) Distances are for passenger cars on level gFade. These distances may be adjusted for downgrades and or sigrifi- cant tnrck traffic. Mere present or projected traffic operations indicate specific needs. consideration may be given to intersection sight distance and operational gap acceptance measurement adjustments. (2) When these vahres are not attainable, refer to the variance process as described in Chapter 2. Section 5. Source: TxDOT Auxiliary Lanes Table 5 is based on Table 2-3 in TxDOT's Access Management Manual, which presents thresholds for requiring acceleration and deceleration auxiliary lanes for driveways. With a projected peak outbound volume of 109 vph (PM peak), and a peak inbound volume of 47 vph (AM peak), neither a deceleration lane nor an acceleration lane would be required for the driveway. Table 5 - Auxiliary Lane Thresholds Right Turn to or from Property (>45 MPH) Acceleration Deceleration Acceleration Deceleration Lane Lane Lane Required? Lane Required? TxDOT Requirement >200 vph > 50 vph Coppell Office Park 109 47 No No Driveway Revised Site Access Plan In following with TxDOT specifications laid out in the Roadway Design Manual and the Access Management Manual, the location of the site driveway as shown on the draft site plan was revised. The revised location of the proposed site driveway, including threshold measurements for the driveway location, was drawn using a provided CAD file of the site's preliminary driveway plan. The revised plan is provided in Figure 8. SAVANT!j GKOUP Page 8 LU 'Airo n yw �a st ` jti a ce it O z ' i F O O T 22 z XNga 0 L6 a .. dw 41V 2 U NS C=O p�• / xlu • i a .100 OSS}' O y Ir UJ U. _ I s; Y m Nom` k i Y b i 13 �F aLU `X, Q J v I i$zo �} y o p � b hay W a. } e! O WNr 2a O p ip F � u z p O m U Q 1-O 1 -OJ M 4HW0 4r- a j(W 6 R W>Z aWON 6WLLJ N Z 0 J Glacier Commercial Realty, LP Coppell Office Park Traffic Study Coppell, Texas As shown in Figure 8, there is a small "envelope" in which the driveway could be placed and meet both minimum driveway spacing requirements and exit ramp spacing requirements. Weaving Analysis Due to the close proximity of the proposed site driveway to the upstream SH 121 southbound off - ramp, a weaving analysis was conducted to determine the effect of vehicles using the off -ramp to access the site on the performance of the SH 121 southbound frontage road at that location. The Texas Transportation Institute's (TTI) report Procedures to Determine Frontage Road Level of Service and Ramp Spacing provides level of service criteria for weaving movements from a mainlane off -ramp to a downstream right turn along an adjacent frontage road. This criteria is based on the computed roadway density, as shown in Table 6. Table 6 — Frontage Road Weaving Level of Service Criteria Level of Service Density (veh/mi/In) Unconstrained < 64 Constrained 64-161 Undesirable I > 161 *Source: TTI (units converted from veh/km/In to veh/mi/In) The vehicle density along the frontage road was calculated using an empirical formula developed by TTI, using frontage road volume, ramp volume, ramp -to -intersection (driveway) spacing, and a factor based on the percentage of ramp traffic turning right at the downstream intersection/driveway. This formula is applied to two-lane frontage roads with auxiliary lanes (2LFR + Aux): where: DL = 0.021(FR) + 0.077(R) - 0.150(L) + 23.4(T) DL = density on weaving link, veh/km/In FR = frontage road volume, vph R = exit ramp volume, vph L = ramp -to -intersection spacing, m T = factor based on percentage of exit ramp vehicles turning right at downstream intersection (T = 0, Percent <= 50; T =1, Percent >50) Since the formula uses metric units, the resulting density was converted to veh/mi/In. The resulting vehicle density and level of service for the southbound SH 121 frontage road adjacent to the proposed site is shown in Table 7. Table 7 — Frontage Road Density and Level of Service AM Peak PM Peak Density (veh/mi/In) 65 55 Level of Service Constrained Unconstrained With the proposed spacing between the upstream off -ramp and the new driveway, and with the traffic volumes expected to make the weaving movement from the ramp to the driveway, the level of service SAVAN'lCI IZOU L' Page 10 Glacier Commercial Realty, LP Coppell Office Park Traffic Study Coppell, Texas along the adjacent frontage road is expected to be "Constrained" during the AM peak, and "Unconstrained" during the PM peak. According to the TTI report, "Unconstrained" LOS corresponds to LOS A -B as defined in the Highway Capacity Manual, while "Constrained" corresponds to LOS C- D. According to the TTI report, "constrained operations represent stable operations in which drivers' ability to maneuver becomes more restricted due to other traffic." As shown in Table 7, the expected density during the AM peak would fall on the low end of the "Constrained" level of service. Conclusions This memorandum describes the traffic study performed for the Coppell Office Park, located along the southbound SH 121 frontage road, west of Denton Tap Road. The study included weaving analysis from the nearby SH 121 exit ramp to the site's proposed driveway, and a geometric analysis of the proposed driveway with regard to TxDOT regulations. The weaving analysis concluded that the proposed location of the driveway would result in minimal impact to traffic flow along the southbound SH 121 frontage road around the proposed site area. Following all specifications in the TxDOT Roadway Design Manual and Access Management Manual, the driveway would need to be built within an approximately 96 -foot wide "envelope" on the James H. and David K. Cummings property immediately west of the proposed Coppell Office park. The proposed site would have connections to both the proposed driveway to the west and the existing TriCounty Plaza driveway adjacent to the east of the site. S AVA N"I' (j G R I J l' Page 11 SAVANTIO GROUP Appendix A: Count Data Coppe110ffice Park Traffic Study Date Began: 1/21/15 SH 121 WBFR between Exit Ramp and Driveway TIME 0:00 0:15 0:30 0:45 TOTAL 0:00 9 9 10 16 44 1:00 5 6 8 6 25 2:00 8 3 7 12 30 3:00 6 11 18 15 50 4:00 15 18 30 38 101 5:00 26 64 74 84 248 6:00 74 116 155 148 493 7:00 155 169 162 195 681 8:00 184 168 139 126 617 9:00 106 96 66 44 312 10:00 17 30 24 22 93 11:00 30 82 102 104 318 12:00 104 106 120 121 451 13:00 110 134 116 120 480 14:00 96 102 100 126 424 15:00 109 114 175 168 566 16:00 212 203 186 117 718 17:00 114 211 189 200 714 18:00 216 235 190 115 756 19:00 98 84 58 48 288 20:00 58 62 68 48 236 21:00 46 56 60 48 210 22:00 44 27 32 30 133 23:00 261 191 ill 12 68 101 AL: 8056 The A.M. peak hour from 7:15 to 8:15 is 710 The P.M. peak hour from 17:45 to 18:45 is 841 800 - --- — - - - - ---- -- - - 700 600 500 LU j 400 J 300 200 100 - - 0 0,11,11,0 i -�- -&4- - i i i . n 00 00 00 00 00 .00 00 .00 .00 00 00 00 00 00 00 00 po 00 00 00 00 0o p0 �. "I'll,rL. nj. b ro 1 O O' ^� fin• 0' 1^5' ^p ^5. ^�• ^A• ^q;. 1p6. 1P. ^. 'C;. lj j. TIME Date Began: 1/21/15 Tri County Plaza Driveway Entrance TIME n -on n.15 n•3n 0.45 TnTAI TOTAL: 38 The A.M. peak hour from 8:15 to 9:15 is 2 The P.M. peak hour from 15:30 to 16:30 is 9 8 - -- 6 5 LU 4 J Q 3 2 0 00 .00 00 00 00 00 00 00 00 .00 00 00 00 00 00 00 00 00 00 00 00 00 00 p0 TIME Date Began: 1/21/15 TO County Plaza Driveway Exit TIME 0:00 0.15 0:30 0.45 TOTAL TOTAL: 30 The A.M. peak hour from 11:00 to 12:00 is 0 The P.M. peak hour from 16:45 to 17:45 is 10 9 -- - - - - - -- - - 8 7 6 W 5 J O 4 3 2 1 0 00 00 00 00 00 00 .00 00 00 00 00 00 0o OO o0 00 00 00 00 00 00 .00 00 00 TIME Date Began: 1/21/15 WB SH 121 Entrance Ramp TIMF n -nn n'15 n -,in n-45 TOTAL 0:00 10 6 7 14 37 1:00 6 5 8 7 26 2:00 8 3 6 14 31 3:00 5 7 16 14 42 4:00 10 20 24 41 95 5:00 27 50 76 82 235 6:00 68 100 170 217 555 7:00 222 222 223 218 885 8:00 232 222 246 245 945 9:00 222 140 84 108 554 10:00 76 86 72 62 296 11:00 102 108 100 104 414 12:00 90 102 102 110 404 13:00 98 126 96 102 422 14:00 69 102 97 102 370 15:00 96 100 136 172 504 16:00 168 210 180 183 741 17:00 205 206 190 169 770 18:00 176 173 169 154 672 19:00 89 79 67 47 282 20:00 46 52 57 39 194 21:00 40 49 52 34 175 22:00 40 32 19 24 115 23:00 21 191 12 11 63 The A.M. peak hour from 8:00 to 9:00 is 945 The P.M. peak hour from 16:45 to 17:45 is 784 1000 - - - - - - - - 900 800 700 600 w j 500 O 400 300 200 100 0 r-1 Fl i 00 00 00 00 00 00 .00 00 00 .00 00 00 z00� 0 0 h 0 0 L 0 00 0� 0 00 00 e00 sp 00 00 O• ^• rl,. "�. �' t`j. O. '1' 4i' O. ^O' �^. �rL' ^^�' ry. �^. TIME Date Began: 1/21/15 WB SH 121 Exit Ramp to SH 121 Business TIME 0:00 0:15 0:30 0:45 TOTAL 0:00 4 2 2 3 11 1:00 1 1 0 1 3 2:00 0 2 3 0 5 3:00 1 1 2 0 4 4:00 1 0 1 0 2 5:00 1 3 2 8 14 6:00 5 7 56 161 229 7:00 142 114 120 114 490 8:00 98 141 162 186 587 9:00 170 59 13 13 255 10:00 8 9 8 11 36 11:00 8 10 6 9 33 12:00 6 12 9 11 38 13:00 13 12 10 16 51 14:00 12 20 15 22 69 15:00 20 18 20 17 75 16:00 17 21 32 50 120 17:00 108 123 126 138 495 18:00 94 60 80 94 328 19:00 23 15 6 16 60 20:00 11 4 6 6 27 21:00 4 8 9 6 27 22:00 8 6 3 4 21 23:00 21 21 21 2 8 I U I AL: 2986 The A.M. peak hour from 8:15 to 9:15 is 659 The P.M. peak hour from 17:00 to 18:00 is 495 700 — - — --- - 600 500 400 w J 300 200 100 ri 0 00 'll 00 �00 � .00 00 00 00 00 .00 .00 00 00 .00 00 00 00 00 00 .00 .00 00 .00 00 p. . �. �. . �. ^o. N ^rl,. ^,,. NV* ^S. ^6. ^1. ^�. ^�. TIME SAVANTOGROUI' Appendix B: Trip Generation Worksheet Coppe110ffice Park Traffic Study Trip Generation ITE Trip Generation, 9th Edition (2012) Project Coppell Office Park Traffic Study Project Number 221-001 Client Glacier Commercial Realty, L.P., LLP 1000 Sq. Feet Gross Site Coppell Office Park Floor Area 47 Land Use General Office Building ITE Code 710 Trips Weekday Total Percent"Ut Number Number In In Out Ln(Trips) = 0.76 * Ln(# units) + 3.68 740 50% 50% 370 370 AM Peak Hour: Weekday Ln(Trips) = 0.80 * Ln(# units) + 1.57 PM Peak Hour: Weekday Trips = 1.12 (# units) + 78.45 Saturday (Peak Hour of Generator) Trips = 0.43 (# units) Created MK 6/14/13 Updated BK 1/20/15 I�-- - - - - - --- -—s _ Trips _ Total Percent Number Number' In Out 105 88% 12% I In Out 92 13 _I 17% 83% 22 109 Trips Total Number Percent In Out Number In Out 131 _I 17% 83% 22 109 Trips Total Number Percent I In Out Number In Out 20 54% 46% 11 9 SAVANT�'j GROUP