Cozby Remodel-CS150619„Pacheco Koch
June 19, 2015
PK No.: 3593-14.414
Mr. Michael Garza, P. E.
Assistant Director of Engineering
CITY OF COPPELL
255 Parkway Boulevard
Coppell, Texas 75019
Re: WILLIAM T. COZBY LIBRARY
Coppell, Texas
Dear Mr. Garza:
Transmitted herewith, via courier service delivery, please find enclosed the following prints for your
approval:
No. Date Description
2 06/19/15 Engineering Plans
1 06/10/15 Markup Plans
1 06/19/15 Comment Response Letter
If the enclosures are not as noted above, please contact this office immediately.
If you have any questions regarding the enclosed items or need any additional information,
please call me at your convenience.
Sincerely,
Grant S. Clay
TBH/slr
3593-14.414 LOT 1
enc.
cc: Tony Blaas - Hidell Associates Architects
II ��� _ 15
8350 N Central Expwy • Suite 1000 1 Dallas, TX 75206-1612 1 T: 972.235.3031 1 F: 972.235.9544 1 pkce.com
„Pacheco Koch
June 19, 2015
PK No.: 3593-14.414
Mr. Michael Garza, P.E.
Assistant Director of Engineering
CITY OF COPPELL
255 Parkway Boulevard
Coppell, Texas 75019
Re: WILLIAM T. COZBY LIBRARY
Coppell, Texas
Dear Mr. Garza:
This letter is to notify you that the enclosed Construction Plans have been revised in accordance
with your June 1], 2015, Review Memorandum. The following items have been addressed as per
the referenced review:
GENERAL
1. Include a copy of the plat.
Response: Comment addressed.
2. We have had flooding issues around the building in the past, as circled on sheet 3.1. We added
a water proofing membrane to the building and some area drains. I'm not sure if this has
helped or not. This comment is more of an FYI.
Response: Comment noted.
3. Remove the details from the set, the contractor will have a copy of our details onsite.
Response: Comment addressed.
DEMOLITION PLAN
4. Show the islands that will be demolished as well.
Response: Comment addressed.
DIMENSION CONTROL PLAN
5. George Marshall in our office would like to see something on the fiber optics in the area.
Response: Comment addressed.
6. Is the intent of the island at the driveway entrance to deter traffic from entering on the exist
side. Is there an alternative that might work better?
Response: The directional signage works sufficiently for the entry/exit area.
8350 N Central Expwy • Suite 1000 1 Dallas, TX 75206-1612 1 T: 972.235.3031 1 F: 972.235.9544 1 pkce.com
Mr. Michael Garza, EIT
June 19, 2015
Page 2
SANITARY SEWER
7. Field Verify the sewer main crossing Heartz Rd. We show it as an 8".
Response: Comment addressed.
8. We would prefer a manhole instead of a10" cleanout.
Response: Comment addressed.
DRAINAGE PLAN
9. What is the drainage area and calculations?
Response: Comment addressed, see sheet C3.1.
PAVING PLAN
10. Where is the sidewalk connection from the trail around the school to the library? Are there
stairs at the end of the sidewalk on the southwest corner? Should there be ADA accessibility?
Response: The stairs in the SW corner have been discussed with Building Inspections and were
deemed acceptable.
If you have any questions or need any additional information, please call at your earliest
convenience.
Sincerely,
Steve A. Markussen, P.E.
TBH/slr
3593 -14.414 -Comment Response Letter