Loading...
ST9902- LR150205nLuAnce OeoTernniML ou Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C13-0634 Date Sampled: 01/06/2015 Report Date: 02/05/2015 Previously Reported: 01/12/2015 Sampled By: Perez, Julio Project: West Sandy Lake Road By Order Of: Royse Location: Walls at Station 1+50 Order Number: 1770 (PSI) (PSI) By Comments Number of 7 6.00 Client: City of Coppell Specimens: 4 REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 178539 Material: Concrete Test Method: See Below TEST RESULTS Report No: 178539 Page 1 of 1 Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 50 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group r Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (int) (Ibs) Break Type Loc (PSI) (PSI) By Comments A 01/13/15: 7 6.00 28.27 78,155 Type 5 Lab 2,760 2,760 B 02/03/15: 28 6.00 28.27 109,470 Type 5 Lab 3,870 C 02/03/15: 28 6.00 28.27 104,335 Type 5 Lab 3,690 3,780 D HOLD (see remarks) - � 0 ®0 Ll Ll I:- I Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification CONFORMS Strength: 3,600 psi @ 28 days Slump: 3-5 Slump: 5.0 Inches Transported By: TXI Air Content: 3-6 Air Content: 3.5% Source/Sampled At: Truck / Center Mix Code: 8272 Plant: 141 Date Received: 01/07/2015 Truck/Ticket No: 0000 12619837 Curing Method: Standard Time Sampled: 12:00 pm Time Batched: 1:28 pm Temp.: Ambient: 52°F Mix: 60°F Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 50 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group r Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION