Loading...
ST9902- LR150304� A�iAnce GGEOTECFiI'IICRL QiOUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444-8889 Fax: (972) 444-8893 Acct ID: 1770 File No: C13-0634 Report Date: 03/04/2015 Project: West Sandy Lake Road Location: Paving sidewalk West Sandy Lake Rd. center median Client: City of Coppell REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST Material: Concrete Date Sampled: 03/03/2015 Sampled By: Avila, Eli By Order Of: Royse Order Number: 1770 Number of Specimens: LAB NO: r Test Method 4 181522 See Below TEST RESULTS Report No: 181522 Page 1 of 1 Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 10 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND. ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED, THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (in Z) (Ibs) Break Type Loc (PSI) (PSI) By Comments A 03/10/15: 7 6.00 28.27 125,430 Type 3 Lab 4,440 B 03/10/15: 7 6.00 28.27 123,450 Type 3 Lab 4,370 4,400 C 03/31/15:28 6.00 28.27 Lab D 03/31/15:28 6.00 28.27 Lab [JE HE M E 11 f LSE 71 Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 4,000 psi @ 28 days Slump: 3-5 Slump: 3.0 Inches Transported By: TXI Air Content: 3-6 Air Content: 5.4% Source/Sampled At: Truck / Center Mix Code: 8272 Plant: 141 Date Received: 03/04/2015 Truck/Ticket No: 0000 / 2692076 Curing Method: Standard Time Sampled: 12:45 pm Time Batched: 12:09 pm Temp.: Ambient: 49°F Mix: 62°F Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 10 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND. ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED, THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.