ST9902- LR150401J RLLIHIYCE
GGEOTECIifYICRL
GROU- -- -
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444-8889 Fax: (972) 444-8893
Acct ID: 1770 File No: C13-0634
Report Date: 04/01/2015 Previously Reported: 03/04/2015
Project: West Sandy Lake Road
Location: Paving sidewalk West Sandy Lake Rd. center median
Date Sampled: 03/03/2015
Sampled By: Avila, Eli
By Order Of: Royse
Order Number: 1770
Specification
Strength: 4,000 psi @ 28 days
Slump: 3-5
Air Content: 3-6
Date Received: 03/04/2015
Curing Method: Standard
Time Sampled: 12:45 pm
Time Batched: 12:09 pm
Temp.: Ambient: 49°F Mix: 62°F
CONFORMS
Slump: 3.0 Inches Transported By: TXI
Air Content: 5.4% Source/Sampled At: Truck / Center
Mix Code: 8272 Plant: 141
Truck/Ticket No: 0000 / 2692076
Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 10 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or
C173, C1064 and C138. Compressive strength tests per ASTM C39.
Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy)
Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
Number of
Client:
City of Coppell
Specimens: 4
REPORT:
REPORT
OF CONCRETE COMPRESSIVE STRENGTH TEST
LAB NO: 181522
Material: Concrete
Test Method: See Below
TEST RESULTS
Report No: 181522
Page 1 of 1
Maximum
Compressive
Average
Spec
Age Tested
Diameter
Area Load
Cure Strength
Strength Tested
Nbr
(date : days)
(in)
(int) (Ibs) Break Type
Loc (PSI)
(PSI) By Comments
A
03/10/15: 7
6.00
28.27 125,430 Type 3
Lab 4,440
B
03/10/15: 7
6.00
28.27 123,450 Type 3
Lab 4,370
4,400
C
03/31/15: 28
6.00
28.27 148,990 Type 3
Lab 5,270
D
03/31/15 : 28
6.00
28.27 145,250 Type 3
Lab 5,140
5,200
H E E M
111-1 �]
1-1
EJ
Type 1 Type 2 Type 3
Type 4 Type 5
Type 6
Specification
Strength: 4,000 psi @ 28 days
Slump: 3-5
Air Content: 3-6
Date Received: 03/04/2015
Curing Method: Standard
Time Sampled: 12:45 pm
Time Batched: 12:09 pm
Temp.: Ambient: 49°F Mix: 62°F
CONFORMS
Slump: 3.0 Inches Transported By: TXI
Air Content: 5.4% Source/Sampled At: Truck / Center
Mix Code: 8272 Plant: 141
Truck/Ticket No: 0000 / 2692076
Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 10 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or
C173, C1064 and C138. Compressive strength tests per ASTM C39.
Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy)
Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.