Loading...
Founders Crossing- LR150416 (2)SUBMITTAL (P) 817-267-3900Ferguson Waterworks 2650 S Pipeline Road Euless, TX 76040 (F) 817-267-3912 www.ferguson.com Contents: WATER: o SERVICE MATERIAL  CERRO – SOFT COPPER  TAPPING SADDLE - MUELLER  SERVICE BRASS - MUELLER CORPORATION AND CURB STOPS  WATTS – BACKFLOW PREVENTER  METER BOX - BASS & HAYS SEWER: o PIPE  NORTH AMERICAN – SDR35 PVC  DIAMOND – SDR35 PVC o MANHOLE RING & COVER  BASS AND HAYS VRM30 o FITTINGS  MULTI FITTING -- TRENCH TOUGH GASKETED WATER: o SERVICE MATERIAL  CERRO – SOFT COPPER  TAPPING SADDLE - MUELLER  SERVICE BRASS - MUELLER CORPORATION AND CURB STOPS  WATTS – BACKFLOW PREVENTER  METER BOX - BASS & HAYS tube COPPER TUBE FOR CONSTRUCTION APPLICATIONS Technical Data: 7-04 Corporate Headquarters PO Box 66800 • St.Louis,MO 63166-6800 888-237-7611 |618-337-6000 • f.618-337-6958 www.cerroflow.com Copper UNS No. C12200 Types K, L, and M ASTM B88 Color marking is not applicable to tube furnished in annealed straight lengths or coils. Typical uses include: • Type M - above ground residential and light commercial uses. (Sizes range from 3/8" - 8" diameter) • Type L - residential and commercial uses. (Sizes range from 1/4" - 8" diameter) • Type K - underground residential, commercial and industrial uses. (Sizes range from 1/4" - 8" diameter) • Type DWV - ASTM B306: used for drainage, waste and vents Cerro tube is the original copper tube for plumbing, air conditioning and refrigeration applications in residential, commercial and institutional installations. We provide a complete range of sizes and types, engineered to exact specifications to meet the highest standards of performance. Product Copper Water Tube, Type K (heavy wall) Copper Water Tube, Type L (medium wall) Copper Water Tube, Type M (light wall) Copper Drainage Tube, Type DWV Temper Hard Soft Hard Soft Hard Hard Lengths 10 ft. straight 20 ft. straight 20 ft. straight 40 ft. coils 60 ft. coils 100 ft. coils 10 ft. straight 20 ft. straight 20 ft. straight 30 ft. coils 40 ft. coils 60 ft. coils 100 ft. coils 10 ft. straight 20 ft. straight 10 ft. straight 20 ft. straight Uses Domestic water service and distribution, fire protection, solar, fuel/fuel oil, HVAC, snow melting, compressed air, natural gas, liquefied petroleum (LP) gas, vacuum Domestic water service and distribution, fire protection, solar, fuel/fuel oil, HVAC, snow melting, compressed air, natural gas, liquefied petroleum (LP) gas, vacuum General plumbing and heating purposes; drainage waste, vent and other light pressure uses. Drainage waste, vents, soil and other non-pressure applications Specifications ASTM B88 ASTM B88 ASTM B88 ASTM B306 Code Green Blue Red Yellow 4.5 Shaded area indicates change Rev. 8-04 MUELLER® BR2B & BR2S SERIES BRONZE SERVICE SADDLES - DOUBLE STRAP MUELLER® Service Saddles for use on A-C, cast iron, ductile iron, and AWWA C900 PVC plastic pipe Pipe O.D. range Kind and size of pipe* Bronze double strapwith AWWA taper thread (C.C.)Optional stainless steel double strapwith AWWA taper thread (C.C.) Inch Base Catalog Base Catalog mm A-C Number Size of tapping (add to “Base”to complete catalog number) Number Size of tapping (add to “Base”to complete catalog number) 3/4" 1" 1-1/4" 1-1/2" 2"5/8"3/4" 1"1-1/4"1-1/2"2" 4.74"-5.32" 121.0-135.0 4"BR 2 B 0474 CC 075 100 125 150 200 BR 2 S 0474 CC 062 075 100 125 150 200 6.84"-7.45" 174.0-189.0 6"BR 2 B 0684 CC 075 100 125 150 200 BR 2 S 0684 CC 062 075 100 125 150 200 8.99"-9.67" 229.0-245.0 8"BR 2 B 0899 CC 075 100 125 150 200 BR 2 S 0899 CC 062 075 100 125 150 200 11.04"-12.12" 281.0-307.0 10" BR 2 B 1104 CC 075 100 125 150 200 BR 2 S 1104 CC 062 075 100 125 150 200 13.14"-14.58"334.0-370.0 12"BR 2 B 1314 CC 075 100 125 150 200 BR 2 S 1314 CC 062 075 100 125 150 200 15.22"-16.88"386.6-428.7 14"BR 2 B 1522 CC 075 100 150 200-BR 2 S 1522 CC 075 100 150 200 - -- 17.32"-19.19"439.9-487.4 16"BR 2 B 1732 CC 075 100 150 200 BR 2 S 1732 CC 075 100 150 200-- 5/8" 062 062 062 062 062 - - Cast or ductile iron, C900 PVC plastic pipe Pipe O.D. range Kind and size of pipe*Bronze double strapwith AWWA I.P. thread (F.I. P.T.)Optional stainless steel double strapwith AWWA I.P. thread (F.I. P.T.) Inch Cast or ductile iron, C900 PVC pipe Base Catalog Base Catalog mm A-C Number Size of tapping (add to “Base”to complete catalog number) Number Size of tapping (add to “Base”to complete catalog number) 3/4" 1" 1-1/4" 1-1/2" 2"3/4" 1"1-1/4"1-1/2"2" 4.74"-5.32" 121.0-135.0 4"BR 2 B 0474 IP 075 100 125 150 200 BR 2 S 0474 IP 075 100 125 150 200 6.84"-7.45" 174.0-189.0 6"BR 2 B 0684 IP 075 100 125 150 200 BR 2 S 0684 IP 075 100 125 150 200 8.99"-9.67" 229.0-245.0 8"BR 2 B 0899 IP 075 100 125 150 200 BR 2 S 0899 IP 075 100 125 150 200 11.04"-12.12" 281.0-307.0 10"BR 2 B 1104 IP 075 100 125 150 200 BR 2 S 1104 IP 075 100 125 150 200 13.14"-14.58"334.0-370.0 12"BR 2 B 1314 IP 075 100 125 150 200 BR 2 S 1314 IP 075 100 125 150 200 15.22"-16.88"386.6-428.7 14"BR 2 B 1522 IP 075 100 150 200-BR 2 S 1522 IP 075 100 150 200 - - 17.32"-19.19"439.9-487.4 16"BR 2 B 1732 IP 075 100 150 200 BR 2 S 1732 IP 075 100 150 200- ** These machines may be used with the service saddles illustrated on this page Machine Service saddle tap size 3/4"1" E-5TM X X D-5TM X X TRU-CUTTM X X MEGA-CUTTM X X PL-2TM X X 5/8" X - - X - BR 2 B Series BR 2 S Series MUELLER® Service Saddles with AWWA taper thread TO ORDER SPECIFY QUANTITY, OUTLET TAPPING SIZE AND CATALOG NUMBER *A-C pipe, classes 150-200 per ASTM C295 and AWWA C400 – actual O.D. of pipe being used must fall within the pipe O.D. range listed in the preceeding charts. Centrifugally cast pipe, classes 50-250 per ANSI/ AWWA C102/A21.2; ANSI/AWWA C106/A21.6; ANSI/AWWA C108/A21.8, and Federal specification WW-P-421. Ductile iron pipe, classes 50-56 per ANSI/AWWA C151/A21.51; Cast iron O.D. PVC plastic pipe per AWWA C900. ** The outside diameter of A-C pipe varies from manufacturer to manufacturer., to make certain you select the proper clamp: 1) Determine the O.D. of the pipe at the point of saddle installation; 2) From the pipe O.D. range column of the above chart, choose a saddle that has a pipe O.D. range that includes the determined pipe diameter. MUELLER® Service Saddles with AWWA iron pipe thread ❏ Outlet tapped with either AWWA taper (C.C.) or AWWA I.P. thread (F.I.P.T.) ❏ For use on A-C pipe, cast iron or ductile iron pipe and cast iron O.D. PVC pipe ❏ 200 psig (1379 kPa) maximum working pressure ❏ Available in double strap designs ❏ Brass body ❏ Flattened silicon bronze straps (standard) ❏ Optional 304L stainless steel straps ❏ Rolled strap threads ❏ O-ring sealed outlet ❏ 3/4" thru 2" tap sizes (5/8" some styles) ❏ Meets all applicable parts of ANSI/AWWA C800 ❏ NSF 61 certified 8A.1 8A - C O P P E R Y O K E S Shaded area indicates change Rev. 8-13 COPPER METER YOKES WITH HORIZONTAL INLET AND OUTLET Multi-purpose thread ends(H-1405N shown) Catalog Description Plain yoke With test valve With lock wing MUELLER 300™ Angle Ball Valve and test valve With lock wing ground key angle meter stop and test valve With lock wing ground key angle meter stop With lock wing MUELLER 300™ Angle Ball Valve number H-1400 H-1401 H-1404 H-1405 B-2404 B-2405 Dimensions Meter size 5/8" 5/8" x 3/4" * 3/4"*1"* Nominal size of I.P. thread in meter nut 3/4"1"1"1-1/4" Dimension A 1-1/16" 1-5/16" 1-5/16" 1-5/8" Dimension B7-7/8"7-7/8"9-5/16" 11-1/16" DimensionC-nominal pipe sizeof inlet and outlet 3/4"3/4"3/4"1" Dimension D7-15/16" 7-15/16" 9-3/8"11-1/8" Dimension E 12-5/8" 12-5/8" 14-1/4" 17-1/4" DimensionF-minimum riser height 7" (9"**) 7" (9" **) 8" (10" **) 10" (12" **) Other riser heights available 9", 12", 15", 18",21", 24", 27", 30",33", and 36" 9", 12", 15", 18",21", 24", 27", 30",33", and 36" 12", 15", 18", 21",24", 27", 30", 33",and 36" 12", 15", 18", 21",24", 27", 30", 33",and 36" Check valve options MUELLER Copper Meter Yokes can be ordered with one of the following: an ASSE approved top entry vertical check valve; an ASSE approved dual check valve; a dual check valve (ASSE non-approved). To order the ASSE approved top entry check feature, add a suffix of -6A to the yoke cataloge number; add - 6D for the same check with a test drain. For the dual check feature, add a suffix of 2A to the yoke catalog number for the ASSE approved model or -2 suffix for the nonapproved model. Examples: H-1404-6DN for the ASSE approved top entry vertical check with a test drain; H- 1404-2AN for the ASSE approved model angle dual check valve. * Add “R” to the end of the *Add "R" to the end of the yoke catalog number to order a reduced port Angle Ball Valve; EXAMPLE: 5/8x3/4x7 B-2404R. ** Minimum with 6A or 6D option. Angle dual check valve M-98TM ASSE approved top entry vertical check valve Copper meter yokes with horizontal inlet and outlet and multi - purpose thread ends Typical installation of a horizontal inlet and outlet copper meter yoke. Note: the 5/8", 5/8" x 3/4", and 3/4"sizes are furnished with a tie bar on heights greater than 15". The 1" size is furnished with a tie bar on heights greater than 18".Copper Meter Yokes are normally supplied less end connections. See pages 8A.48 and 8A.49 for end connections that can be used with these yokes. N N N N N N SPECIFY METER SIZE, RISER HEIGHT AND CATALOG NUMBER. MUELLER Copper Meter Yokes are manufactured and tested in accordance with ANSI/AWWA C800. Components in contact with potable water will also comply with latest requirements of the Federal Safe Drinking Water Act. For Non-Health Hazard Applications ES-LF007 Now Available WattsBox Insulated Enclosures. For more information, send for literature ES-WB. Series LF007 Double Check Valve Assemblies Sizes: 1⁄2" – 3" (15 – 80mm) Series LF007 Double Check Valve Assemblies shall be installed at referenced cross-connections to prevent the backflow of polluted water into the potable water supply. Only those cross-connections identified by local inspection authorities as non-health hazard shall be allowed the use of an approved double check valve assembly. The LF007 features Lead Free* construction to comply with Lead Free* installation requirements. Check with local authority having jurisdiction regarding vertical orien- tation, frequency of testing or other installation requirements. The valve shall meet the requirements of ASSE Std. 1015 and AWWA Std. C510. Approved by the Foundation for Cross- Connection Control and Hydraulic Research at the University of Southern California. Features • Ease of maintenance — only one cover • Top entry • Replaceable seats and seat discs • Modular construction • Compact design •  Lead Free* cast copper silicon alloy body construction — 1⁄2" – 2" (15 – 50mm) • Fused epoxy coated cast iron body — 21⁄2" – 3" (65 – 80mm) • Top mounted Lead Free* ball valve test cocks • Low pressure drop • No special tools required for servicing • 1⁄2" – 1" (15 – 25mm) have tee handles Specifications A Double Check Valve Assembly shall be installed at each noted location. The assembly shall consist of two positive seating check modules with captured springs and rubber seat discs. The check module seats and seat discs shall be replaceable. Service of all internal components shall be through a single access cover secured with stainless steel bolts. The Double Check Valve Assemblies shall be constructed using Lead Free* cast copper silicon alloy. Lead Free* Double Check Valve Assemblies shall comply with state codes and standards, where applicable, requir- ing reduced lead content. The assembly shall also include two resilient seated isolation valves; four top mounted, resilient seated test cocks. The assembly shall meet the requirements of ASSE Std. 1015 and AWWA Std. C510. Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be a Watts Series LF007. Test Cocks First CheckModule Assembly The LF007 Series features a modular design concept which facilitates complete maintenance and assembly by retaining the spring load. Second CheckModule Assembly *The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with- out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. 3⁄4" (20mm) LF007M3QT Job Name ––––––––––––––––––––––––––––––––––––––––––– Contractor –––––––––––––––––––––––––––––––––––––––––––– Job Location ––––––––––––––––––––––––––––––––––––––––– Approval ––––––––––––––––––––––––––––––––––––––––––––– Engineer ––––––––––––––––––––––––––––––––––––––––––––– Contractor’s P.O. No. –––––––––––––––––––––––––––––––––– Approval ––––––––––––––––––––––––––––––––––––––––––––– Representative –––––––––––––––––––––––––––––––––––––––– LEAD FREE* NOTICE Inquire with governing authorities for local installation requirements As A C B TRD Bs F Subscript ‘S’ = strainer model Pressure — Temperature 1⁄2" – 2" (15 – 50mm) Temperature Range: 33°F – 180°F (0.5°C – 82°C). Maximum Working Pressure: 175psi (12.1 bar). 21⁄2" – 3" (65 – 80mm) Temperature Range: 33˚F – 110°F (0.5˚C – 43°C) continuous, 140°F (60°C) intermittent. Maximum Working Pressure: 175psi (12.1 bar). Standards ASSE Std. 1015, AWWA Std. C510 IAPMO PS31, CSA B64.5 Approvals † ASSE, AWWA, IAPMO, CSA, UPC s Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. • Models with suffix LF and S are not listed. u UL Classified (without shutoff valves only) 3⁄4" – 2" (20 – 50mm) (except 007M3LF) u UL Classified with OSY gate valves (21⁄2" and 3" horizontal only.) ▼ 1⁄2" - 2" models Lead Free* with strainer Horizontal and vertical “flow up" approval on all sizes Models Sizes: 1⁄2" – 2" (15 – 50mm) Suffix: S - copper silicon alloy strainer LF - without shutoff valves Prefix: U - Union connections 21⁄2" – 3" (65 – 80mm) Suffix: NRS - non-rising stem resilient seated gate valves OSY - UL/FM outside stem and yoke resilient seated gate valves LF - without shutoff valves QT-FDA - FDA epoxy coated quarter-turn ball valves MoDeL Size (DN)DiMeNSioNS WeighT A B C D F G R T in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. †s▼LF007QT 1⁄2 15 10 254 45⁄8 117 27⁄16 62 — — 5 127 33⁄8 85 25⁄16 59 21⁄16 52 4.5 2 †s▼LF007M3QT 3⁄4 20 111⁄8 282 4 102 31⁄8 79 — — 63⁄16 157 37⁄16 87 21⁄8 54 15⁄16 33 5 2.3 †s▼LF007M1QT 1 25 131⁄4 337 51⁄8 130 4 102 — — 71⁄2 191 33⁄8 85 111⁄16 43 111⁄16 43 12 5.4 †s▼LF007M2QT 11⁄4 32 163⁄8 416 5 127 35⁄16 84 — — 91⁄2 241 5 127 3 76 2 50 15 6.8 †s▼LF007M2QT 11⁄2 40 163⁄4 425 47⁄8 124 31⁄2 89 — — 93⁄4 248 513⁄16 148 31⁄8 79 211⁄16 68 15.9 7.2 †s▼LF007M1QT 2 50 191⁄2 495 61⁄4 159 4 102 — —133⁄8 340 61⁄8 156 37⁄16 87 211⁄16 68 25.7 11.7 •▼LF007QT-S 1⁄2 15 13 330 6 152 27⁄16 62 3 76 5 127 33⁄8 85 25⁄16 59 21⁄16 52 5.5 2.5 •▼LF007M3QT-S 3⁄4 20 141⁄2 368 61⁄8 156 31⁄8 79 3 76 63⁄16 157 37⁄16 87 21⁄8 54 15⁄16 33 6.7 3.1 •▼LF007M1QT-S 1 25 1715⁄16 157 73⁄4 197 4 102 31⁄4 83 71⁄2 191 33⁄8 85 111⁄16 43 111⁄16 43 14 6.4 •▼LF007M2QT-S 11⁄4 32 211⁄2 546 71⁄16 179 35⁄16 84 31⁄2 83 91⁄2 241 5 127 3 76 2 50 19 8.6 •▼LF007M2QT-S 11⁄2 40 251⁄16 637 71⁄16 179 31⁄2 89 33⁄4 95 93⁄4 248 513⁄16 148 31⁄8 79 211⁄16 68 19.6 8.9 •▼LF007M1QT-S 2 50 271⁄4 692 83⁄4 222 4 102 4 102 133⁄8 340 61⁄8 156 37⁄16 87 211⁄16 68 33.5 15.2 Dimensions – Weights MoDeL Size(DN)DiMeNSioNS A in.mm in.mm LFU007QT 1⁄2 15 1213⁄16 326 LFU007M2QT 3⁄4 20 1313⁄16 350 LFU007M2QT 1 25 165⁄8 422 LFU007M2QT 11⁄4 32 203⁄4 527 LFU007M2QT 11⁄2 40 211⁄2 546 LFU007M1QT 2 50 241⁄2 622 Strainer Dimensions Size WeighT M N in. mm in. mm in. mm lbs. kgs. 21⁄2 65 10 254 61⁄2 165 28 13 3 80 101⁄8 267 7 178 34 15 A C (open)9" (229mm) 45⁄16" (109mm) N e1 e R A Union Tailpiece Union Tailpiece Union Nut Union Nut Dimensions – Weights Sizes: 21⁄2" – 3" (65 – 80mm) 1" LFU007M1QT Sizes: 1⁄2" – 2" (15 – 50mm) M MoDeL Size (DN)DiMeNSioNS WeighT A B E, E1 R in. mm in. mm in. mm in. mm in. mm lbs. kgs. LF007QT-FDA 21/2 65 331/8 841 63/8 162 91⁄16 230 83/4 222 155 70 s LF007-NRS 21/2 65 331/8 841 93/8 238 91⁄16 230 83/4 222 155 70 su LF007-OSY 21/2 65 331/8 841 163/8 416 91⁄16 230 83/4 222 158 72 LF007-QT-FDA 3 80 331/8 867 63/8 162 91⁄16 230 83/4 222 155 70 s LF007-NRS 3 80 331/8 867 101/4 260 91⁄16 230 83/4 222 185 84 su LF007-OSY 3 80 331/8 867 187⁄8 479 91⁄16 230 83/4 222 185 84 bars psi .8 12 .7 10 .5 8 .4 6 .3 4 .1 2 0 0 0 2 4 6 8 10 12 gpm 0 7.6 15.2 22.8 30.4 38 45.6 lpm 5 7.5 10 fps 1.5 2.5 3.0 mps Pr e s s u r e D r o p Flow Flow 1⁄2" (15mm) 11⁄2" (40mm) Capacity As compiled from documented Foundation for Cross-Connection Control and hydraulic Research at the University of Southern California lab tests. †† Typical maximum system flow rate (7.5 feet/sec., 2.3 meters/sec.)** UL rated flow bars psi 1.5 22 1.2 18 .96 14 .69 10 .41 6 .14 2 0 5 10 15 20 25 30 35 40 45 50 gpm 0 19 38 57 76 95 114 133 152 171 190 lpm 7.5 15 lps 2.3 4.6 mps Pr e s s u r e D r o p Flow Pr e s s u r e D r o p Flow 0 25 50 75 100 125 150 175 200 gpm 0 95 190 285 380 475 570 665 760 lpm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 3⁄4" (20mm) 2" (50mm) bars psi 1.1 16 .8 12 .7 10 .5 8 .4 6 .3 4 .1 2 0 5 10 15 20 25 30 35 40 45 50 55 60 gpm 0 19 38 57 76 95 114 133 152 171 190 209 228 lpm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Pr e s s u r e D r o p Flow Pr e s s u r e D r o p Flow 0 25 50 75 100 125 150 175 200 225 250 gpm 0 95 190 285 380 475 570 665 760 855 950 lpm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 1" (25mm) 21⁄2" (65mm) bars psi 1 14 .8 12 .7 10 .5 8 .4 6 .3 4 .1 2 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 lpm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Pr e s s u r e D r o p Flow Pr e s s u r e D r o p Flow 0 25 50 75 100 125 150 175 200 225 250 275 300 325 gpm 0 95 190 285 380 475 570 665 760 855 950 1045 1140 1235 lpm 5 7.5 10 fps 1.5 2.3 3.0 mps 11⁄4" (32mm) 3" (80mm) bars psi .8 12 .7 10 .5 8 .4 6 .3 4 .1 2 0 0 bars psi .8 12 .7 10 .5 8 .4 6 .3 4 .1 2 0 0 bars psi .7 10 .5 8 .4 6 .3 4 .1 2 0 0 bars psi .7 10 .5 8 .4 6 .3 4 .1 2 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 66 304 342 380 418 456 lpm 5 7.5 10 15 fps 1.5 2.5 3.0 4.5 mps Pr e s s u r e D r o p †† ** ** †† †††† †††† †††† ES-LF007 1325 © 2013 Watts USA: Tel: (978) 688-1811 • Fax: (978) 794-1848 • www.watts.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • www.watts.ca A Watts Water Technologies Company SEWER: o PIPE  NORTH AMERICAN – SDR35 PVC  DIAMOND – SDR35 PVC o MANHOLE RING & COVER  BASS AND HAYS VRM30 o FITTINGS  MULTI FITTING -- TRENCH TOUGH GASKETED Rev: 01/2006 Product Description: ASTM D3034 Gravity Sewer Pipe North American Pipe's ASTM D3034 Gravity Sewer PVC product line is manufactured to meet the needs of modern municipal waste water systems, residential waste water control and other non- pressure applications. With top quality raw materials and modern processing technology North American Pipe's ASTM D3034 Gravity Sewer pipe meets all industry standards in addition to our own rigorous quality control standards. North American Pipe’s ASTM D3034 Gravity Sewer pipe utilizes Reiber style gaskets throughout the entire product offering. North American Pipe produces a full range of ASTM D3034Gravity Sewer pipe in SDR-35 and SDR-26 classifications. Whether specifying or installing our pipe you can be assured that North American Pipe will provide the pipe “Right, On Time, All the Time”. This product is made in accordance with the following specifications: ASTM D3034 ASTM D1784 ASTM F477 ASTM D3212 Short Form Specification for North American Pipe Corporation ASTM D3034 Gravity Sewer Pipe PVC gravity sewer pipe shall be made from a compound conforming to a cell classification of 12454 or 12364 as defined by ASTM D1784 and in accordance with ASTM D3034 for sizes four inch through fifteen inch. The wall thickness, when tested according to ASTM D3412, shall correspond to a dimension ratio of SDR 35 with a pipe stiffness value of 46 or SDR26 with a pipe stiffness of 115 for heavy wall pipe. Integral bells shall incorporate locked in gaskets meeting the requirements of ASTM D3212 and F477. The laying length of the pipe shall be 14 feet. Rev: 01/2006 ASTM D3034 Gravity Sewer Pipe NOMINAL PIPE SIZE OUTSIDE DIA. – NOM. (OD) *APPROX. BELL DIA. (BD) **APPROX. BELL DEPTH (C) INSERT MARK (L) 4” 4.215 5.25 4.27 3.250 6” 6.275 7.50 5.40 4.125 8” 8.400 10.00 6.27 4.250 10” 10.500 12.25 7.16 5.250 12” 12.500 14.25 8.04 5.500 15” 15.300 17.25 9.61 7.500 NOMINAL PIPE SIZE SDR 35 (T) SDR 26 (T) SDR 23.5 (T) 4” .120 .162 .178 6” .180 .241 .265 8” .240 .323 10” .300 .404 12” .360 .481 15” .437 .588 Note: These dimensions are for estimating purposes only * Dimension given for Approx. Bell Diameter (BD) is for highest pressure class ** Nominal depth, depth will vary by pressure class page 13 thirteen Sani-21™: PVC Sewer Pipe SPECIFICATION DATA D3034 & F679 SEWER SPECIFICATION DATA Diamond gravity sewer pipe 4 inches through 48 inches shall be made of compounds conforming to material requirements of ASTM D3034 and ASTM F679 in accordance with ASTM D1784. Diamond PVC Sewer Pipe meets all the dimensional, chemical, and physical requirements as outlined in ASTM D3034 and ASTM F679. The pipe sizes 4 inches through 48 inches are made with an integral bell “water-tight” joint that meets the requirements of ASTM D3212 and that utilizes a Rieber gasket system for sealing that meets the requirements of ASTM F477. Each male end shall be beveled to facilitate joining and referencing marked for proper insertion depth. Diamond furnished lubricant is to be used in the joining process. Physical Properties of ASTM D3034 & F679 Pipe Materials: Pipe shall be made of PVC plastic having a minimum cell classification of 12454 or 12364 as defined in Specification D1784. Property ASTM Minimum T e s t Specific Gravity D792 1.40 Tensile Strength, psi D638 7,000 Tensile Modulus, psi D638 400,000 IZOD Impact Strength, D256 .65ft., lb./in. SHORT FORM Specification for Diamond PVC Solid-Wall Sewer Pipe SDR 26 or SDR 35 or PS 46 or PS 115 Diamond PVC Solid-Wall Sewer PIpe shall be made of compounds conforming to ASTM D1784 manufactured in accordance with the material requirements of ASTM D3034 or ASTM F679. Diamond PVC Sewer Pipe must meet all dimensional, chemical, and physical requirements as outlined in ASTM D3034 orASTM F679. Diamond PVC Sewer Pipe shall be installed according to the requirements of ASTM D2321. Joints shall meet the requirements of ASTM D3212 and shall be formed using Rieber Technology. Uni-Bell UNI-PUB 6, “and the manufacturer’s requirements.” Corporate Headquarters 1212 Johnstown Road P.O. Box 1608 Grand Island, NE 68802-1608 SANITARY SEWER PIPE FOR THE 21st CENTURY Pipe Stiffness Pipe Modulus SDR E = 400,000 E = 500,000 41 28 35 35 46 57 26 115 144 Standard laying lengths are 14 and 22 feet TM SANITARY SEWER PIPE FOR THE 21st CENTURY page 14 fourteen Sani-21™: PVC Sewer Pipe SPECIFICATION DATA SANITARY SEWER PIPE FOR THE 21st CENTURY Standard laying lengths are 14 & 22 feet “Possession of this page does not constitute an offer of sale” Prices are subject to a firm policy of “Price in effect at time of shipment on regular purchases” D3034 & F679 SEWER SPECIFICATION DATA Nominal Pipe Size Inches Outside Diameter A Inches Bell Socket Diameter B Inches Socket Depth C Inches Insert Mark D Inches Wall Thickness SDR26/PS115 (t) Inches Wall Thickness SDR35/PS46 (t) Inches 4 4.215 5-1/4 4-5/8” 4“ 0.162 0.120 6 6.275 7-1/2 4-3/4” 4“ 0.241 0.180 8 8.400 9-7/8 6-1/8” 5“ 0.323 0.240 10 10.500 12-3/8 6-3/4” 6“ 0.404 0.300 12 12.500 14-5/8 7-1/4” 6“ 0.481 0.360 15 15.300 18 6-3/4” 6” 0.588 0.437 Strength Corporate Headquarters 1212 Johnstown Road P.O. Box 1608 Grand Island, NE 68802-1608 D-3034 Pipe Dimensions F-679 Pipe Dimensions A B D C Reiber Joint Illustration Sani-21™ 18 18.701 21-3/4” 7-3/4” 7” 0.671 0.499 21 22.047 25-1/2” 7-3/4” 7” 0.791 0.588 24 24.803 28-3/4” 8-1/2” 7-1/4” 0.889 0.661 27 27.953 32-1/2” 8-1/2” 7-1/4” 1.002 0.745 30 ciod 32.000 37-1/4” 12” 10” 1.148 0.853 36 ciod 38.300 43-1/4” 12” 10” 1.373 1.021 42 ciod 44.500 53” 16” 13” 1.187 48 ciod 50.800 60” 16” 13” 1.355 Sani-21 is supplied in 14 foot and 22 foot laying lengths. TM SANITARY SEWER PIPE FOR THE 21st CENTURY SE C T I O N A - A 38 " 4" 1 3 / 8 " 32 1 / 8 " 30 " 32 1 / 8 " 1 3 / 8 " TO P F L A N G E V I E W BO T T O M F L A N G E V I E W (1 ) 7 / 8 " D I A HA N D L I N G H O L E A A 41600410®Revised By:S B B SDC3/8/2003 4/12/2012 ejco.comreserve the right to modify specifications without pr ior notice. -ASTM A48 -All rights reserved.-Materials -D e sign LoadGray Iron (CL35)Heavy Duty -Open Area -Coating Undipped - Designates Machined Surface Copyright © 2011 EJ Group, Inc.a n d/or know how that is the property of EJ Group, Inc.registered marks, patents, trade secret information,-Country of Origin: USA-CONFIDENTIAL: This drawing is the property of EJ Group, Inc. and embodies confidential information, Weights (lbs/kg), dimensions (inches/mm)and drawings provided for your guidance. We 800 626 4653Designer:ContactProduct Number Design Features Certification DisclaimerDrawing Revision V1 6 0 0 - 4 F r a m e P.O. Box 3300, Term."A" London, Ont. Canada N6A 4K3 (519) 681-2140 1-800-265-1815 Fax (519) 681-2156 4507 LeSaint Court Fairfield, Ohio USA 45014 (513) 942-9910 1-800-523-3539 Fax (513) 942-9914 MULTI FITTINGS Engineered Tough SDR 35 GASKETED SEWER FITTINGS LETTER OF COMPLIANCE Scope: This letter of compliance covers Multi Fittings requirements for 4” through 42” (100 mm – 1050 mm) PVC Trench Tough SDR35 Gasketed Sewer Fittings. These products meet or exceed performance standards set by the American Society of Testing and Materials (ASTM), CSA International (CSA) and the International Association of Plumbing and Mechanical Officials (IAPMO). Trench Tough SDR35 Gasketed Sewer Fittings are compatible with pipe manufactured to ASTM D 3034, CSA B182.1 and CSA B182.2 and is suitable for the non-pressure drainage of sewage and surface water. They can also be used in applications involving subsurface drainage. Material: Rigid PVC Poly(Vinyl Chloride) used in the manufacturing of Trench Tough SDR35 Gasketed Sewer Fittings complies with ASTM D 1784, Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds, having a cell classification 12454 or 13343. Gasket materials used in the manufacturing of Trench Tough SDR35 Gasketed Sewer Fittings complies with either of the following requirements: ASTM F 477 “Standard Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe” for low-head applications for rubber gaskets ASTM F 913 “Standard Specification for Thermoplastic Elastomeric Seals (Gaskets) for Joining Plastic Pipe” for TPE gaskets Molded Fittings: Molded Trench Tough SDR35 Gasketed Sewer Fittings conform to the following standards: ASTM D 3034 “Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings” ASTM D 3212 “Standard Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals” ASTM F 1336 “Standard Specification for Poly(Vinyl Chloride) (PVC) Gasketed Sewer Fittings” CSA B182.1 “Plastic Drain and Sewer Pipe and Pipe Fittings” CSA B182.2 “PVC Sewer Pipe and Fittings (PSM Type)” IAPMO “Uniform Plumbing Code” Page 2/... Trench Tough SDR35 Gasketed Sewer Fittings Fabricated Fittings: Fabricated Trench Tough SDR35 Gasketed Sewer Fittings are made from segments of pipe conforming to the following standards: ASTM D3 034 “Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings” ASTM D 3212 “Standard Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals” ASTM F 679 “Standard Specification for Poly(Vinyl Chloride) (PVC) Large-Diameter Plastic Gravity Sewer Pipe and Fittings” ASTM F 1336 “Standard Specification for Poly(Vinyl Chloride) (PVC) Gasketed Sewer Fittings” CSA B182.2 “PVC Sewer Pipe and Fittings (PSM Type)” Note: Molded components meeting the requirements listed above may also be used as part of the fabricated fitting. Markings: Trench Tough SDR35 Gasketed Sewer Fittings are marked as prescribed in the above applicable standards to indicate size of the fittings, material designation, compliance to standard, and manufacturer’s name or trademark. Color Coding: Gaskets for Trench Tough SDR35 Gasketed Sewer Fittings are black. Yours truly, Frank Yorio Senior Vice President, Operations Issue Date: 2012-01-16