ST0502A- LR150611 (2)G I • GEOTECHNICAL ENGINEERING E I • ENVIRONMENTAL CONSULTING E + CONSTRUCTION MATERIALS TESTING GEE Consultants, Inc. 10046 Monroe Drive • Dallas, Texas 75229 a (214) 352-5433 0 Fax (214) 352-6972 REPORT OFCONCRETE MIX OBSERVATION Measured Slump (in.) Report Date: June 11, 2015 Date Concrete Placed: June 3, 2015 Standard 6"xl2" Cylinders Client: City of Coppell Cylinder Cross-sectional Area: 28.27 Square Inches Project: Freeport Pkwy from Ruby Rd. to Sandy Lake Rd. Concrete Report No.: 211 Contractor: CD Builders FPP 810 Project No.: 214-0144 Concrete Supplier and Plant: Agros 110 Location of Placement: Median Nose - Stamped Concrete 4.25 MATERIALS Source / SSD Batch Wts. OBSERVATION DATA Description (Lbs/CuYd) - 28 Mix Number: 1043 Time Sample Batched: 9:04 AM Cement: Time Sampled: 9:30 AM Fly Ash: Sample Location: Median Nose STA. 25+55 to Fracture Regular Cylinders Made By: CP ASTM C-31, C-39, C-143 25+90 Coarse Aggregate: Truck / Ticket No: 3338/1620551 Intermediate Aggregate: Temperature: Fine Aggregate: Ambient Range: 79 OF Admixtures: Concrete Range: 82 OF I Slump Range (inches): 4.25 2 Weather Conditions: Sunny Added Water: 0 Time Started: 8:30 AM Time Completed: 12:15 PM Sample Air Content (%): 3.0 Total Cubic Yards Placed: 10 Rprnrirprl Rtrenot}t (I .hs /sn in 1• inns Specimen Number Measured Slump (in.) Age (Days) Date Tested Total Load (Lbs.) Compressive Strength (Lbs./Sq.ln.) Remarks FPP 809 7 6/10/15 110,340 3,900 FPP 810 28 7/1/15 4.25 FPP 811 28 7/1/15 FPP 812 H Hold Test Methods Utilized Fracture Regular Cylinders Made By: CP ASTM C-31, C-39, C-143 (Unless Noted Otherwise) Remarks and/or Distribution:- None cc: Mr. Rick Odell - City of Coppell via E-mail: ROdell@coppelltx.gov Mr. Michael Garza - City of Coppell, Phone: 972-304-3679; via E-mail: MGarza@coppelltx.gov Mr. Mitch Holmes - Teague, Nall & Perkins, Phone: 432-312-4205; via E-mail: mholmes@tnpinc.com Mr. Francisco Luyando - CD Builders, Inc., Phone: 787-688-8207; via E-mail: fluyando@cdbuilderspr.com e GEE Consultants, Inc. TBPE Firm: F-3212 Reviewed by: ?'N4 f44 All letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced without the full approval of GEE Consultants, Inc. The use of our name must receive our prior written approval, Our letters and reports apply only to the sample tested and/or observed and are not necessarily indicative of the quantities of apparently identical or similar products.