ST0502A- LR150603 (2)GEOTECHNICAL ENGINEERING E I* ENVIRONMENTAL CONSULTING E I - CONSTRUCTION MATERIALS TESTING GEE Consultants, Inc. 10046 Monroe Drive • Dallas, Texas 75229 0 (214) 352-5433 - Fax (214) 352-6972 Report Date: June 3, 2015 Date Concrete Placed: May 5, 2015 Standard 6"xl2" Cylinders Client: City of C oppell Cylinder Cross-sectional Area: 28.27 Square Inches Project: Freeport Pkwy from Ruby Rd. to Sandy Lake Rd. Concrete Report No.: 191 Contractor: CD Builders Project No,: 214-0144 Concrete Supplier and Plant: Agros Il 0 Location of Placement: Paving Median Crossing STA 9+30 to 10+50 MATERIALS Source / SSD Batch Wts. OBSERVATION DATA Description (Lbs/CuYd) Mix Number: 1273 Time Sample Batched: 10:29 AM Cement: Time Sampled: 11:00 AM Fly Ash: Sample Location: Paving Median Crossing STA Coarse Aggregate: 5/12/15 9+30 to 10+50 Intermediate Aggregate: Truck / Ticket No: 4046/1609940 Fine Aggregate: Temperature: 6/2/15 Admixtures: Ambient Range: 74 OF I Concrete Range: 86 OF Slump Range (inches): 3.5 2 Weather Conditions: Mostly Cloudy Added Water: 0 Time Started: 9:30 AM 4,950 Time Completed: 3:30 PM Sample Air Content (%): 4.2 Total Cubic Yards Placed: 10 Test Methods Utilized. J Rt-.nnirp.d qtri-noth (I he Izn in l 1A00 Specimen Number Measured Slump (in.) Age (Days) Date Tested Total Load (Lbs.) Compressive Strength (Lbs./Sq.1n.) Remarks FPP 729 7 5/12/15 128,380+ 4,540+ FPP 730 28 6/2/15 140,680+ 4,980+ 3.5 FPP 731 28 6/2/15 140,060 4,950 FPP 732 H Hold Test Methods Utilized. J Fracture Regular Cylinders Made By: CP Cy t ASTM C-31, 9, C_I C: -t3 43 (Unless Noted Otherwise) Remarks and/or Distribution:- None cc: Mr. Rick Odell - City of Coppell via E-mail: ROdell@coppelltx.gov Mr. Michael Garza - City of Coppell, Phone: 972-304-3679; via E-mail: MGarza@coppelltx.gov Mr. Mitch Holmes - Teague, Nall & Perkins, Phone: 432-312-4205; via E-mail: mholmes@tnpinc.com Mr. Francisco Luyando - CD Builders, Inc., Phone: 787-688-8207; via E-mail: fluyando@cdbuilderspr,com GEE Consultants, Inc. TBPE Firm: F-3212 Reviewed by: All letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced without the full approval of GEE Consultants, Inc. The use lofour name must receive our prior written approval. Our letters and reports apply only to the sample tested and/or observed and are not necessarily indicative of the quantities of apparently identical or similar products, -INICAL ENGINEERING IVIRONMENTAL CONSULTING GEE Consultants, Inc. L–I IL- —1 I *CONSTRUCTION MATERIALS TESTING L 10046 Monroe Drive • Dallas, Texas 75229 0 (214) 352-5433 0 Fax (214) 352-6972 REINFORCING STEEL PLACEMENT Report Date: June 3, 2015 Test Date: May 28, 2015 Client: City of Coppell General Report No.: 133 Project Freeport Parkway Project No.: 214-144 Identification Reinforcing Steel Observation Method of Test Visual Observation Page I of I Results On May 28, 2015 reinforcing steel was observed at the following locations: I)Mcdian Nose, stamped concrete. STA. 29+00 to 29+50. The following discrepancies were noted and called to the attention of Antonio, a representative of CD Builders. 1) Clean diet from existing concrete. 2) Use rebar support. The above discrepancies were corrected as noted. Technician: CP cc: Mr. Michael Garza - City of Coppell, Phone: 972-304-3679; via E-mail: MGarza@coppelltx.gov Mr. Mitch Holmes - Teague, Nall & Perkins, Phone: 432-312-4205; via E-mail: mbolmes@tnpinc.com Mr. Francisco Luyando - CD Builders, Inc., Phone: 787-688-8207; via E-mail: fluyando@cdbuilderspr.com Mr. Rick Odell - City of Coppell via E-mail: ROdell@coppelltx.gov GEE Consultants, Iric. TBPE Firm: F-3212 Reviewed by: L�``��',.,; All letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced without the full approval of GEE Consultants, Inc. The use Of our name must receive our prior written approval. Our letters and reports apply only to the sample tested and/or observed and are not necessarily indicative of the quantities of apparently identical or similar products. • GEOTECHNICAL ENGINEERING E -ENVIRONMENTAL CONSULTING A — GEE ConsultanB, Inc. 7E* CONSTRUCTION MATERIALS TESTING 10046 Monroe Drive Dallas, Texas 75229 0 (214) 352-5433 •Fax (214) 352-6972 REINFORCING S'T'EEL PLACEMENT Report Date: June 3,'201.5 Test Date: June 1, 2015 Client: City of Coppell General Report No,: 134 Project Freeport Parkway Project No.: 214-144 Identification Reinforeing Steel Observation Method of Test Visual Observation Page I of I Results On June 1, 2015 reinforcing steel was observed at the following locations: ])Median Nose - Stamped Concrete, STA, I 1+10 to H +60. The following discrepancies were noted and called to the attention of Antonio, a representative of CD Builders. 1) Supplemented with rebar support. 2) Clean existing concrete and rebar. The above discrepancies were corrected as noted. Technician: CP cc: Mr. Michael Garza- City of Coppell, Phone: 972-304-3679; via E-mail: MGarza@coppelltx.gov Mr. Mitch Holmes - Teague, Nall & Perkins, Phone: 432-312-4205; via E-mail: mholmes@tnpinc.com Mr. Francisco Luyando - CD Builders, Inc., Phone: 787-688-8207; via E-mail: fluyando@cdbuilderspr.com Mr. Rick Odell - City of Coppell via E-mail: rodell@coppelltx.gov GEE Consultants, Inc. — TAPE Firm: F-3212 Reviewed by: All letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced without the full approval of GEE Consultants, Inc. The use of our name must receive our prior written approval. Our letters and reports apply only to the sample tested and/or observed and are not necessarily indicative of the quantities ofapparent) y identical or similar products.